 共查询到20条相似文献,搜索用时 15 毫秒
1.
Field evaluations and comparisons of continuous fine particulate matter (PM2,5) mass measurement technologies at an urban and a rural site in New York state are performed. The continuous measurement technologies include the filter dynamics measurement system (FDMS) tapered element oscillating microbalance (TEOM) monitor, the stand-alone TEOM monitor (without the FDMS), and the beta attenuation monitor (BAM). These continuous measurement methods are also compared with 24-hr integrated filters collected and analyzed under the Federal Reference Method (FRM) protocol. The measurement sites are New York City (the borough of Queens) and Addison, a rural area of southwestern New York state. New York City data comparisons between the FDMS TEOM, BAM, and FRM are examined for bias and seasonality during a 2-yr period. Data comparisons for the FDMS TEOM and FRM from the Addison location are examined for the same 2-yr period. The BAM and FDMS measurements at Queens are highly correlated with each other and the FRM. The BAM and FDMS are very similar to each other in magnitude, and both are approximately 25% higher than the FRM filter measurements at this site. The FDMS at Addison measures approximately 9% more mass than the FRM. Mass reconstructions using the speciation trends network filter data are examined to provide insight as to the contribution of volatile species of PM2.5 in the FDMS mass measurement and the fraction that is likely lost in the FRM mass measurement. The reconstructed mass at Queens is systematically lower than the FDMS by approximately 10%.  相似文献   

2.
ABSTRACT

In recent years, scientific discussion has included the influence of thermodynamic conditions (e.g., temperature, relative humidity, and filter face velocity) on PM retention efficiency of filter-based samplers and monitors. Method-associated thermodynamic conditions can, in some instances, dramatically influence the presence of particle-bound water and other light-molecular-weight chemical components such as particulate nitrates and certain organic compounds. The measurement of fine particle mass presents a new challenge for all PM measurement methods, since a relatively greater fraction of the mass is semi-volatile.

The tapered element oscillating microbalance (TEOM) continuous PM monitor is a U.S. Environmental Protection Agency (EPA) PM10 equivalent method (EQPM-1090-079). Several hundred of these monitors are deployed throughout the United States. The TEOM monitor has the unique characteristic of providing direct PM mass measurement without the calibration uncertainty inherent in mass surrogate methods. In addition, it provides high-precision, near-real-time continuous data automatically. Much attention has been given to semi-volatile species retention of the TEOM method.

While using this monitor, it is desirable to maintain as low an operating temperature as practical and to remove unwanted particle-bound water. A new sample equilibration system (SES) has been developed to allow conditioning of the PM sample stream to a lower humidity and temperature level. The SES incorporates a special low-particle-loss Nafion dryer. This paper discusses the configuration and theory of the SES. Performance results include high time-resolved PM2.5 data comparison between a 30 °C sample stream TEOM monitor with SES and a standard 50 °C TEOM monitor. In addition, 24-hr integrated data are compared with data collected using an EPA PM2.5 Federal Reference Method (FRM)-type sampler. The SES is a significant development because it can be applied easily to existing TEOM monitors.  相似文献   

3.
The tapered element oscillating microbalance (TEOM) is one type of continuous ambient particulate matter (PM) monitor. Adsorption and desorption of moisture and semivolatile species may cause positive or negative artifacts in TEOM PM mass measurement. The objective of this field study was to investigate possible uncertainties associated with TEOM measurements in the poultry operation environment. For comparisons of TEOM with filter-based gravimetric method, four instruments (TEOM-PM10, low-volume PM10 sampler TEOM-PM2.5, and PM2.5 speciation sampler) were collocated and tested inside a poultry house for PM2.5 and PM10 (PM with aerodynamic equivalent diameter < or =2.5 and < or =10 microm, respectively) measurements. Fifteen sets of 24-hr PM10 concentrations and 13 sets of 24-hr PM2.5 measurements were obtained. Results indicate that compared with filter-based gravimetric method, TEOM gave significantly lower values of both PM10 and PM2.5 mass concentrations. For PM10, the average ratio of TEOM to the gravimetric method was 0.936. For PM2.5, the average ratio of TEOM to the gravimetric method was 0.738. Particulate matter in the poultry houses possibly contains semivolatile compounds and moisture due to high levels of relative humidity (RH) and gas pollutants. The internal heating mechanism of the TEOM may cause losses in mass through volatilization. To investigate the effects of TEOM settings on concentration measurements, the heaters of two identical TEOMs were set at 50 degrees C, 30 degrees C, or no heating at all. They were collocated and tested for total suspended particle (TSP), PM10, and PM25 measurements in layer house for 6 weeks. For all TSR PM10, and PM2.5 measurements, the internal TEOM temperature setting had a significant effect (P < 0.05). Significantly higher PM mass concentrations were measured at lower temperature settings. The effects of environmental (i.e., temperature, RH, NH3 and CO2 concentrations) and instrumental (i.e., filter loading and noise) parameters on PM measurements were also assessed using regression analysis.  相似文献   

4.
Ammonium nitrate and semivolatile organic material (SVOM) are significant components of fine particles in urban atmospheres. These components, however, are not properly determined with methods such as the fine particulate matter (PM2.5) Federal Reference Method (FRM) or other single filter samplers because of significant losses of semivolatile material (SVM) from particles collected on the filter during sampling. The R&P tapered element oscillating microbalance (TEOM) monitor also does not measure SVM, because this method heats the sample to remove particle bound water, which also results in evaporation of SVM. Recent advances in monitoring techniques have resulted in samplers for both integrated and continuous measurement of total PM2.5, including the particle concentrator-Brigham Young University organic sampling system (PC-BOSS), the real-time total ambient mass sampler (RAMS), and the R&P filter dynamics measurement system (FDMS) TEOM monitor. Results obtained using these samplers have been compared with those obtained with either a PM2.5 FRM sampler or a TEOM monitor in studies conducted during the past five years. These studies have shown the following: (1) the PC-BOSS, RAMS, and FDMS TEOM are all comparable. Each instrument measures both the nonvolatile material and the SVM. (2) The SVM is not retained on the heated filter of a regular TEOM monitor and is not measured by this sampling technique. (3) Much of the SVM is also lost during sampling from single filter samplers such as the PM2.5 FRM sampler. (4) The amount of SVM lost from single filter samplers can vary from less than one-third of that lost from heated TEOM filters during cold winter conditions to essentially all during warm summer conditions. (5) SVOM can only be reliably collected using an appropriate denuder sampler. (6) A PM2.5 speciation sampler can be easily modified to a denuder sampler with filters that can be analyzed for semivolatile organic carbon (OC), nonvolatile OC, and elemental carbon using existing OC/elemental carbon analytical techniques. The research upon which these statements are based for various urban studies are summarized in this paper.  相似文献   

5.
Abstract

Increased interest in the health effects of ambient par–ticulate mass (PM) has focused attention on the evaluation of existing mass measurement methodologies and the definition of PM in ambient air. The Rupprecht and Patashnick Tapered Element Oscillating MicroBalance (TEOM®) method for PM is compared with time–integrated gravimetric (manual) PM methods in large urban areas during different seasons. Comparisons are conducted for both PM10 and PM2.5 concentrations.

In urban areas, a substantial fraction of ambient PM can be semi–volatile material. A larger fraction of this component of PM10 may be lost from the TEOM–heated filter than the Federal Reference Method (FRM). The observed relationship between TEOM and FRM methods varied widely among sites and seasons. In East Coast urban areas during the summer, the methods were highly correlated with good agreement. In the winter, correlation was somewhat lower, with TEOM PM concentrations generally lower than the FRM. Rubidoux, CA, and two Mexican sites (Tlalnepantla and Merced) had the highest levels of PM10 and the largest difference between TEOM and manual methods.

PM2.5 data from collocation of 24–hour manual samples with the TEOM are also presented. As most of the semi–volatile PM is in the fine fraction, differences between these methods are larger for PM2.5 than for PM10.  相似文献   

6.
In recent years, scientific discussion has included the influence of thermodynamic conditions (e.g., temperature, relative humidity, and filter face velocity) on PM retention efficiency of filter-based samplers and monitors. Method-associated thermodynamic conditions can, in some instances, dramatically influence the presence of particle-bound water and other light-molecular-weight chemical components such as particulate nitrates and certain organic compounds. The measurement of fine particle mass presents a new challenge for all PM measurement methods, since a relatively greater fraction of the mass is semi-volatile. The tapered element oscillating microbalance (TEOM) continuous PM monitor is a U.S. Environmental Protection Agency (EPA) PM10 equivalent method (EQPM-1090079). Several hundred of these monitors are deployed throughout the United States. The TEOM monitor has the unique characteristic of providing direct PM mass measurement without the calibration uncertainty inherent in mass surrogate methods. In addition, it provides high-precision, near-real-time continuous data automatically. Much attention has been given to semi-volatile species retention of the TEOM method.  相似文献   

7.
Continuous monitoring of particulate matter (PM) with a diameter less than 2.5 microm (PM2.5) is quickly gaining acceptance as an alternative means of measuring fine PM in the United States. For this project, data were taken from all monitoring sites within Region 5 that used the tapered element oscillating microbalance (TEOM) for PM2.5 and had a collocated Federal Reference Method (FRM) monitor. Scatter plots of TEOM versus FRM show that for a significant fraction of the observations, an independent factor causes the TEOM to underestimate the FRM value. This underestimation appears to increase as temperature decreases. For this analysis, a linear relationship was fit to the TEOM versus FRM data, allowing a break or knot in the relationship, modeled as a change of slope, at a site-specific temperature. To test whether the models are adequate for adjusting future measurements, models were also developed using the first year of data only, and the remaining observations were used to test the durability of the relationships. For all but one monitor in Minnesota, the models developed for each site had consistently high R2s, were predictive of future measurements, and could be used to derive "FRM-like" results from the TEOM measurements. The temperature knots fitted by the model for individual sites ranged from 12.9 to 20.6 degrees C. Data from all six sites in the state of Michigan were also combined to determine if a single model could be developed for the entire state. While the single model for the state of Michigan worked reasonably well, some of the predicted concentrations at individual sites were systematically underestimating the observed concentrations on more polluted days. The same conclusion was drawn for a Region 5-wide model. This approach was also found to work very well for six individual TEOM monitors in New York State.  相似文献   

8.
The U.S. Environmental Protection Agency (EPA) has proposed a new secondary standard based on visibility in urban areas. The proposed standard will be based on light extinction, calculated from 24-hr averaged measurements. It would be desirable to base the standard on a shorter averaging time to better represent human perception of visibility. This could be accomplished by either an estimation of extinction from semicontinuous particulate matter (PM) data or direct measurement of scattering and absorption. To this end we have compared 1-hr measurements of fine plus coarse particulate scattering using a nephelometer, along with an estimate of absorption from aethalometer measurements. The study took place in Lindon, UT, during February and March 2012. The nephelometer measurements were corrected for coarse particle scattering and compared to the Filter Dynamic Measurement System (FDMS) tapered element oscillating microbalance monitor (TEOM) PM2.5 measurements. The two measurements agreed with a mass scattering coefficient of 3.3 ± 0.3 m2/g at relative humidity below 80%. However, at higher humidity, the nephelometer gave higher scattering results due to water absorbed by ammonium nitrate and ammonium sulfate in the particles. This particle-associated water is not measured by the FDMS TEOM. The FDMS TEOM data could be corrected for this difference using appropriate IMPROVE protocols if the particle composition is known. However, a better approach may be to use a particle measurement system that allows for semicontinuous measurements but also measures particle bound water. Data are presented from a 2003 study in Rubidoux, CA, showing how this could be accomplished using a Grimm model 1100 aerosol spectrometer or comparable instrument.

Implications: Visibility is currently based on 24-hr averaged PM mass and composition. A metric that captures diurnal changes would better represent human perception. Furthermore, if the PM measurement included aerosol bound water, this would negate the need to know particulate composition and relative humidity (RH), which is currently used to estimate visibility. Methods are outlined that could accomplish both of these objectives based on use of a PM monitor that includes aerosol-bound water. It is recommended that these techniques, coupled with appropriate measurements of light scattering and absorption by aerosols, be evaluated for potential use in the visibility based secondary standard.  相似文献   

9.
This study comprehensively characterizes hourly fine particulate matter (PM(2.5)) concentrations measured via a tapered element oscillating microbalance (TEOM), beta-gauge, and nephelometer from four different monitoring sites in U.S. Environment Protection Agency (EPA) Region 5 (in U.S. states Illinois, Michigan, and Wisconsin) and compares them to the Federal Reference Method (FRM). Hourly characterization uses time series and autocorrelation. Hourly data are compared with FRM by averaging across 24-hr sampling periods and modeling against respective daily FRM concentrations. Modeling uses traditional two-variable linear least-squares regression as well as innovative nonlinear regression involving additional meteorological variables such as temperature and humidity. The TEOM shows a relationship with season and temperature, linear correlation as low as 0.7924 and nonlinear model correlation as high as 0.9370 when modeled with temperature. The beta-gauge shows no relationship with season or meteorological variables. It exhibits a linear correlation as low as 0.8505 with the FRM and a nonlinear model correlation as high as 0.9339 when modeled with humidity. The nephelometer shows no relationship with season or temperature but a strong relationship with humidity is observed. A linear correlation as low as 0.3050 and a nonlinear model correlation as high as 0.9508 is observed when modeled with humidity. Nonlinear models have higher correlation than linear models applied to the same dataset. This correlation difference is not always substantial, which may introduce a tradeoff between simplicity of model and degree of statistical association. This project shows that continuous monitor technology produces valid PM(2.5) characterization, with at least partial accounting for variations in concentration from gravimetric reference monitors once appropriate nonlinear adjustments are applied. Although only one regression technically meets new EPA National Ambient Air Quality Standards (NAAQS) Federal Equivalent Method (FEM) correlation coefficient criteria, several others are extremely close, showing optimistic potential for use of this nonlinear adjustment model in garnering EPA NAAQS FEM approval for continuous PM(2.5) sampling methods.  相似文献   

10.
Comparison of 24 h mean PM2.5 aerosol loadings determined by a TEOM and by two manual gravimetric samplers (a low-volume filter sampler and a Micro Orifice Uniform Deposit Impactor) in four Australian cities, on 15 days in the winter half-year, revealed systematically lower results from the TEOM by an average of >30%. This result is consistent with reports from elsewhere suggesting that semi-volatile aerosol material is lost from the heated sample filter employed on the TEOM.  相似文献   

11.
EU Directives stipulate that PM10 should be measured using the gravimetric reference method as laid out in EN12341 [CEN, 1998. Air Quality – Determination of the PM10 Fraction of Suspended Particulate Matter – Reference Method and Field Test Procedure to Demonstrate Reference Equivalence of Measurement Methods. European Committee for Standardisation], or an equivalent method as demonstrated using EC guidance [EC, 2005. Demonstration of Equivalence of Ambient Air Monitoring Methods. European Commission Working Group on Guidance for the Demonstration of Equivalence]. There is however a conflict between the requirement to measure PM10 using the gravimetric reference method and the need for rapid public reporting, and many member states, including the UK, rely on non-gravimetric techniques to measure PM10. In the UK the majority of PM10 measurements are made using the Tapered Element Oscillating Microbalance (TEOM), which does not meet the equivalence criteria [Harrison, D., 2006. UK Equivalence Programme for Monitoring of Particulate Matter. Defra, London]. The implied need to upgrade or replace TEOMs with an equivalent automated measurement technique has significant cost implications. The model described in this paper was based on analysis of daily mean measurements of PM10 by the Filter Dynamics Measurement System (FDMS) and the TEOM at UK sites. It uses the FDMS measurement of the volatile component of PM10 (referred to here as FDMS purge) to correct for differences in the sensitivity to volatile PM10 between the TEOM and the EU gravimetric reference method. The model equation for the correction of TEOM PM10 measurements is: TEOMVCM = TEOM ? 1.87 FDMS purge due to the regional homogeneity of volatile PM, the FDMS purge concentration may be measured at a site distant to the TEOM, allowing the possibility of using a single FDMS instrument to correct PM10 measurements made by several TEOMs in a defined geographical area. The model was assessed against the criteria for the EC Working Group's Guidance for the Demonstration of Equivalence of Ambient Air Monitoring Methods [EC, 2005. Demonstration of Equivalence of Ambient Air Monitoring Methods. European Commission Working Group on Guidance for the Demonstration of Equivalence]. The model satisfies the equivalence criteria using remote FDMS purge measurements for distances up to 200 km (in 22 out of 23 data sets). These data provide strong evidence that the model is a viable tool for correcting measurements from TEOM instruments on the national and local government networks.  相似文献   

12.
The Fresno Supersite intends to 1) evaluate non-routine monitoring methods, establishing their comparability with existing methods and their applicability to air quality planning, exposure assessment, and health effects studies; 2) provide a better understanding of aerosol characteristics, behavior, and sources to assist regulatory agencies in developing standards and strategies that protect public health; and 3) support studies that evaluate relationships between aerosol properties, co-factors, and observed health end-points. Supersite observables include in-situ, continuous, short-duration measurements of 1) PM2.5, PM10, and coarse (PM10 minus PM2.5) mass; 2) PM2.5 SO4(-2), NO3-, carbon, light absorption, and light extinction; 3) numbers of particles in discrete size bins ranging from 0.01 to approximately 10 microns; 4) criteria pollutant gases (O3, CO, NOx); 5) reactive gases (NO2, NOy, HNO3, peroxyacetyl nitrate [PAN], NH3); and 6) single particle characterization by time-of-flight mass spectrometry. Field sampling and laboratory analysis are applied for gaseous and particulate organic compounds (light hydrocarbons, heavy hydrocarbons, carbonyls, polycyclic aromatic hydrocarbons [PAH], and other semi-volatiles), and PM2.5 mass, elements, ions, and carbon. Observables common to other Supersites are 1) daily PM2.5 24-hr average mass with Federal Reference Method (FRM) samplers; 2) continuous hourly and 5-min average PM2.5 and PM10 mass with beta attenuation monitors (BAM) and tapered element oscillating microbalances (TEOM); 3) PM2.5 chemical speciation with a U.S. Environmental Protection Agency (EPA) speciation monitor and protocol; 4) coarse particle mass by dichotomous sampler and difference between PM10 and PM2.5 BAM and TEOM measurements; 5) coarse particle chemical composition; and 6) high sensitivity and time resolution scalar and vector wind speed, wind direction, temperature, relative humidity, barometric pressure, and solar radiation. The Fresno Supersite is coordinated with health and toxicological studies that will use these data in establishing relationships with asthma, other respiratory disease, and cardiovascular changes in human and animal subjects.  相似文献   

13.
Collocated comparisons for three PM2.5 monitors were conducted from June 2011 to May 2013 at an air monitoring station in the residential area of Fort McMurray, Alberta, Canada, a city located in the Athabasca Oil Sands Region. Extremely cold winters (down to approximately ?40°C) coupled with low PM2.5 concentrations present a challenge for continuous measurements. Both the tapered element oscillating microbalance (TEOM), operated at 40°C (i.e., TEOM40), and Synchronized Hybrid Ambient Real-time Particulate (SHARP, a Federal Equivalent Method [FEM]), were compared with a Partisol PM2.5 U.S. Federal Reference Method (FRM) sampler. While hourly TEOM40 PM2.5 were consistently ~20–50% lower than that of SHARP, no statistically significant differences were found between the 24-hr averages for FRM and SHARP. Orthogonal regression (OR) equations derived from FRM and TEOM40 were used to adjust the TEOM40 (i.e., TEOMadj) and improve its agreement with FRM, particularly for the cold season. The 12-year-long hourly TEOMadj measurements from 1999 to 2011 based on the OR equations between SHARP and TEOM40 were derived from the 2-year (2011–2013) collocated measurements. The trend analysis combining both TEOMadj and SHARP measurements showed a statistically significant decrease in PM2.5 concentrations with a seasonal slope of ?0.15 μg m?3 yr?1 from 1999 to 2014.Implications: Consistency in PM2.5 measurements are needed for trend analysis. Collocated comparison among the three PM2.5 monitors demonstrated the difference between FRM and TEOM, as well as between SHARP and TEOM. The orthogonal regressions equations can be applied to correct historical TEOM data to examine long-term trends within the network.  相似文献   

14.
Long-term field comparisons of continuous and integrated filter measurements of mass concentrations of particulate matter (PM) with an aerodynamic diameter less than or equal to 2.5 microm (PM2.5) were performed at rural and urban sites in New York State. Two versions of the continuous tapered element oscillating microbalance (TEOM) mass monitor are deployed at each site, in addition to Federal Reference Method filter samplers. Data are grouped into monthly averages to retain and demonstrate seasonal differences. Strong seasonal dependence is observed-the TEOM monitors with the heated sensors are biased systematically low with respect to the Federal Reference Method measurements during the cold season. For the rural site, the average bias for the sample equilibration system (SES)-equipped and standard TEOM monitors is 14 and 24%, respectively. At this location, the TEOM monitor measurements were biased low for all 34 months. For the urban site, the average bias for the SES and standard TEOM monitors is 8 and 18%, respectively. At this location, the TEOM monitor measurements are as likely to be biased high as low during the warm-season months. The hour averaged data from the two versions of the TEOM monitor are also compared, and also indicate that the SES-equipped version of the TEOM monitor captures 7-11% more PM2.5 mass at these locations.  相似文献   

15.
Outdoor and indoor fine particulate species were measured at the Lindon Elementary School in Lindon, Utah, to determine which components of ambient fine particles have strong indoor and outdoor concentration correlations. PM2.5 mass concentrations were measured using tapered element oscillating microbalance (TEOM) monitors and by gravimetric analysis of Teflon filter samples. Gas-phase HNO3, sulfur dioxide, particulate nitrate, strong acid, and particulate sulfate were measured using annular denuder samplers. Soot was measured using quartz filters in filter packs. Total particulate number was measured with a condensation nucleus counter (CNC). Total particulate number and fine particulate sulfate and soot were correlated for ambient and indoor measurements. Indoor PM2.5 mass showed a low correlation with outdoor PM2.5 mass because of the influence of coarse material from student activities on indoor PM2.5. Fine particle acidity and the potentiation of biological oxidative mechanisms by iron were not correlated indoors and outdoors.  相似文献   

16.
Abstract

The GRIMM model 1.107 monitor is designed to measure particle size distribution and particulate mass based on a light scattering measurement of individual particles in the sampled air. The design and operation of the instrument are described. Protocols used to convert the measured size number distribution to a mass concentration consistent with U.S. Environmental Protection Agency protocols for measuring particulate matter (PM) less than 10 μm (PM10) and less than 2.5 μm (PM2.5) in aerodynamic diameter are described. The performance of the resulting continuous monitor has been evaluated by comparing GRIMM monitor PM2.5 measurements with results obtained by the Rupprecht and Patashnick Co. (R&P) filter dynamic measurement system (FDMS). Data were obtained during month-long studies in Rubidoux, CA, in July 2003 and in Fresno, CA, in December 2003. The results indicate that the GRIMM monitor does respond to total PM2.5 mass, including the semi-volatile components, giving results comparable to the FDMS. The data also indicate that the monitor can be used to estimate water content of the fine particles. However, if the inlet to the monitor is heated, then the instrument measures only the nonvolatile material, more comparable to results obtained with a conventional heated filter tapered element oscillating microbalance (TEOM) monitor. A recent modification of the model 180, with a Nafion dryer at the inlet, measures total PM2.5 including the nonvolatile and semi-volatile components, but excluding fine particulate water. Model 180 was in agreement with FDMS data obtained in Lindon, UT, during January through February 2007  相似文献   

17.
Fine particulate matter (PM2.5) mass was determined on a continuous basis at the Salt Lake City Environmental Protection Agency Environmental Monitoring for Public Awareness and Community Tracking monitoring site in Salt Lake City, UT, using three different monitoring techniques. Hourly averaged PM2.5 mass data were collected during two sampling periods (summer 2000 and winter 2002) using a real-time total ambient mass sampler (RAMS), sample equilibration system (SES)-tapered element oscillating microbalance (TEOM), and conventional TEOM monitor. This paper compares the results obtained from the various monitoring systems, which differ in their treatment of semivolatile material (SVM; particle-bound water, semivolatile ammonium nitrate, and semivolatile organic compounds). PM2.5 mass results obtained by the RAMS were consistently higher than those obtained by the SES-TEOM and conventional TEOM monitors because of the RAMS ability to measure semivolatile ammonium nitrate and semivolatile organic material but not particle-bound water. The SES-TEOM monitoring system was able to account for an average of 28% of the SVM, whereas the conventional TEOM monitor loses essentially all of the SVM from the single filter during sampling. Occasional mass readings by the various TEOM monitors that are higher than RAMS results may reflect particle-bound water, which, under some conditions, is measured by the TEOM but not the RAMS.  相似文献   

18.
Measurements collected using five real-time continuous airborne particle monitors were compared to measurements made using reference filter-based samplers at Bakersfield, CA, between December 2, 1998, and January 31, 1999. The purpose of this analysis was to evaluate the suitability of each instrument for use in a real-time continuous monitoring network designed to measure the mass of airborne particles with an aerodynamic diam less than 2.5 microns (PM2.5) under wintertime conditions in the southern San Joaquin Valley. Measurements of airborne particulate mass made with a beta attenuation monitor (BAM), an integrating nephelometer, and a continuous aerosol mass monitor (CAMM) were found to correlate well with reference measurements made with a filter-based sampler. A Dusttrak aerosol sampler overestimated airborne particle concentrations by a factor of approximately 3 throughout the study. Measurements of airborne particulate matter made with a tapered element oscillating microbalance (TEOM) were found to be lower than the reference filter-based measurements by an amount approximately equal to the concentration of NH4NO3 observed to be present in the airborne particles. The performance of the Dusttrak sampler and the integrating nephelometer was affected by the size distribution of airborne particulate matter. The performance of the BAM, the integrating nephelometer, the CAMM, the Dusttrak sampler, and the TEOM was not strongly affected by temperature, relative humidity, wind speed, or wind direction within the range of conditions encountered in the current study. Based on instrument performance, the BAM, the integrating nephelometer, and the CAMM appear to be suitable candidates for deployment in a real-time continuous PM2.5 monitoring network in central California for the range of winter conditions and aerosol composition encountered during the study.  相似文献   

19.
Fine particles in urban atmospheres contain substantial quantities of semi-volatile material [e.g., NH4NO3 and semi-volatile organic compounds (SVOCs)] that are lost from particles during collection on a filter. Several diffusion denuder samplers have been developed for the determination of both NO3- and organic semi-volatile fine particulate components. The combination of technology used in the BOSS diffusion denuder sampler and the Harvard particle concentrator has resulted in the Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) for the 24-hr (or less) integrated collection of PM2.5, including NH4NO3 and semi-volatile organic material. Modification of the BOSS sampler allows for the weekly determination of these same species. Combination of BOSS denuder and tapered element oscillating microbalance (TEOM) monitor technology has resulted in the real-time ambient mass sampler (RAMS) for the continuous measurement of PM2.5, including the semi-volatile components. Comparison of the results obtained with the BOSS and with each of the newly developed modifications of the BOSS indicates that the modified versions can be used for the continuous, daily, or weekly monitoring of PM2.5, including semi-volatile species, as appropriate to the design of each sampler.  相似文献   

20.
Abstract

This study comprehensively characterizes hourly fine particulate matter (PM2.5) concentrations measured via a tapered element oscillating microbalance (TEOM), β-gauge, and nephelometer from four different monitoring sites in U.S. Environment Protection Agency (EPA) Region 5 (in U.S. states Illinois, Michigan, and Wisconsin) and compares them to the Federal Reference Method (FRM). Hourly characterization uses time series and autocorrelation. Hourly data are compared with FRM by averaging across 24-hr sampling periods and modeling against respective daily FRM concentrations. Modeling uses traditional two-variable linear least-squares regression as well as innovative nonlinear regression involving additional meteorological variables such as temperature and humidity. The TEOM shows a relationship with season and temperature, linear correlation as low as 0.7924 and nonlinear model correlation as high as 0.9370 when modeled with temperature. The β-gauge shows no relationship with season or meteorological variables. It exhibits a linear correlation as low as 0.8505 with the FRM and a nonlinear model correlation as high as 0.9339 when modeled with humidity. The nephelometer shows no relationship with season or temperature but a strong relationship with humidity is observed. A linear correlation as low as 0.3050 and a nonlinear model correlation as high as 0.9508 is observed when modeled with humidity. Nonlinear models have higher correlation than linear models applied to the same dataset. This correlation difference is not always substantial, which may introduce a tradeoff between simplicity of model and degree of statistical association. This project shows that continuous monitor technology produces valid PM2.5 characterization, with at least partial accounting for variations in concentration from gravimetric reference monitors once appropriate nonlinear adjustments are applied. Although only one regression technically meets new EPA National Ambient Air Quality Standards (NAAQS) Federal Equivalent Method (FEM) correlation coefficient criteria, several others are extremely close, showing optimistic potential for use of this nonlinear adjustment model in garnering EPA NAAQS FEM approval for continuous PM2.5 sampling methods.  相似文献   