首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 877 毫秒
1.
The Electric Power Research Institute (EPRI) is currently supporting a major research program characterizing the performance of high efficiency electrostatic precipitators (ESP). One such effort evaluating the George Neal ESP of Iowa Public Service Company is described in this paper.Results show that under well tuned conditions the ESP overall collection efficiency was 99.7% at a specific collecting area of 745 ft2/kacfm (147 m2/m3/s) (520 MW) with associated mass concentrations of 0.025 lb/106 Btu and stack opacity of 4.6%. The boiler outlet size distribution was found to be bimodal with submicron and large particle peaks at 0.2 and 5 microns diameter, respectively. Consequently, an apparent bimodal fractional efficiency curve results with efficiencies of 99.6%, 98%, and 90% measured for 20, 2 and 0.2 micron diameter particles, respectively. Rapping reentrainment losses were found to be insignificant except during episodes of high ash hopper levels resulting from a malfunctioning ash removal system, when large rapping puffs were observed. In addition, outlet emissions increased dramatically to 0.08 lb/106 Btu (34 ng/J) during these periods, suggesting that an emission level more representative of daily operation lies somewhere between 0.025–0.08 lb/106 Btu (10.8–34 ng/J).  相似文献   

2.
Two cold side electrostatic precipitators handling low sulfur eastern bituminous coal flyash were upgraded from 94% to 99.4% efficiency in order to meet a particulate compliance limit of 0.1 lb/MMBtu (43 ng/J).The comprehensive upgrading was the result of a 2 year research and testing program during which various aspects of flue gas conditioning, electrical energization, rapping, coal quality control, and gas distribution were independently tested on three similar precipitators. The ensuing upgrading program included the installation of hardware for maximum performance and reliability as well as flue gas conditioning and a fuel ash control program.A cost and reliability analysis of the upgrading program as compared with the installation of an additional series precipitator is included.  相似文献   

3.
The paper describes the results of a study of the impact of the National Energy on the trend towards increased utilization of coal and lignite in Texas with forecasts of increased coal and lignite utilization for the electric utility and industrial sectors. Environmental impacts of this increased coal and lignite use are projected in terms of increased air pollutant emissions and air quality impacts. Economic costs of compliance with alternative source emission regulations are also projected for the electric utility industry.Lignite consumption in Texas under the National Energy Plan is projected to increase from the present 13 million metric tons in 1976 to 57 million metric tons annually by 1985. Sub-bituminous coal consumption in Texas is projected to increase from 1 million metric per year in 1976 to 49 million metric tons per year in 1985. Bituminous coal consumption in Texas is expected to increase from less than one million metric tons per year in 1976 to about 3 million metric tons per year in 1985.Major increases in sulfur oxides emissions from coal and lignite combustion in Texas can be expected by 1985 of up to 1.5 × 109 kg per year without controls and 0.2 × 109 kg per year with controls. Increases in acid precipitation formation will result in north-east Texas from extensive lignite usage for electric power generation as a detriment to agriculture. The photochemical air pollution problem in the Houston area will probably worsen primarily because of increased nitrogen oxides and sulfur oxides emissions because of industrial coal combustion. Capital costs of air pollution controls in Texas for coal-fired utility boilers are estimated as up to U.S. $3.9 billion by 1985, with total operating costs of up to U.S. $1.2 billion per year.  相似文献   

4.
As a follow-up to a pilot study, a full scale investigation of applying high velocity fabric filtration to coal-fired boiler fly ash control was conducted. Two filter systems were separately applied to two 60,000 lb/h coal-fired boilers. Performance evaluations conducted over the course of a year included total mass removal efficiency and fractional efficiencies. One filtration system employed Teflon felt as the filter media while the second system employed Gore-Tex, a Polytetrofluorethylene (PTFE) laminate on PTFE woven backing. During the course of the year, a limited number of glass felt and woven glass bags were introduced into the house containing Gore-Tex. As a separate option, the second system was outfitted entirely with woven glass bags. Preliminary results indicate acceptable performance at air-to-cloth ratio of 6 to 1. Future plans call for utilizing one of the baghouse systems for SO2 removal.  相似文献   

5.
The environmental issue has become a major subject in the last few decades affecting science and technology throughout the world due to the serious environmental impacts caused by industrial air pollution. Consequently, pulse jet filtration has become the preferred choice all around the world. Researchers are continuously striving for new concepts of more energy-efficient and compact particulate collector which can meet future emission limits and operating requirements. The system can also satisfy stringent emission norms and if required, it can be embedded with new technique for simultaneous control of particulate and gaseous pollutants. In the recent past, stress is also being given to having control over the source to reduce or eliminate waste, and finally, on waste management. Prevention is frequently more cost-effective than control. The paper discusses all these methodology toward sustainability in the perspective of effective control of industrial air pollution.  相似文献   

6.
Samples of respirable particulate matter collected during a personal monitoring study in Topeka, KS, were analyzed for iron, aluminum, and lead content. The sampling protocol and instrumentation are described in detail. Lead indoor concentrations (median = 79 ng/m3) were found to be less than both personal (median = 112 ng/m3) and outdoor lead concentrations (median = 106 ng/m3). The indoor, outdoor, and personal levels of iron and aluminum were not significantly different. In addition, it was determined that outdoor respirable particulate mass does not correlate well with the personal or indoor metal concentrations, and that the amount of time spent in motor vehicles is a relatively good indicator of lead exposures. The relationships between indoor, outdoor, and personal lead are discussed in greater detail, with references to supporting evidence from other studies.  相似文献   

7.
This paper presents the results of an evaluation of excessive salt emissions from 16 hogged fuel boilers in Washington, Oregon, and Alaska. Logs transported or stored in sea water, absorb substantial amounts of salt which is noncombustible, and is emitted as a fine particulate when the hogged fuel is burned, contributing to opacity and particulate emissions. Control measures considered are fuel pretreatment, combustion modification, use of conventional particulate control devices (electrostatic precipitators, fabric filters, and wet scrubbers), and several novel particulate control devices.The best available control technology appears to be a mechanical collector-fabric filter combination; some electrostatic scrubber type devices have also shown excellent capability.  相似文献   

8.
The Stockholm Convention on Persistent Organic Pollutants includes in its aims the minimisation of unintentional releases of polychlorinated dibenzo-dioxins and dibenzofurans (PCDD/PCDF) and dioxin like PCB (dl-PCB) to the environment. Development and implementation of policies to achieve this aim require accurate national inventories of releases of PCDD/PCDF/dl-PCB. To support this objective, the Conference of Parties established a process to review and update the UNEP Standardized Toolkit for Identification and Quantification of Dioxin and Furan Releases. An assessment of all emission inventories was that for many countries open burning of biomass and waste was identified as the major source of PCDD/PCDF releases. However, the experimental data underpinning the release estimates used were limited in number and, consequently, confidence in the accuracy of the emissions predictions was low. There has been significant progress in measurement technology since the last edition of the Toolkit in 2005. In this paper we reassess published emission factors for release of PCDD/PCDF and dl-PCB to land and air.In total, four types of biomass and 111 emission factors were assessed. It was found that there are no systematic differences in emission factors apparent between biomass types or fire classes. The data set is best described by a lognormal distribution. The geometric mean emission factors (EFs) for releases of PCDD/PCDF to air for the four biomass classes used in the Toolkit (sugarcane, cereal crops, forest and savannah/grass) are 1.6 μg TEQ (t fuel)−1, 0.49 μg TEQ (t fuel)−1, 1.0 μg TEQ (t fuel)−1 and 0.4 μg TEQ (t fuel)−1, respectively. Corresponding EFs for release of PCDD/PCDF to land are 3.0 ng TEQ (kg ash)−1, 1.1 ng TEQ (kg ash)−1, 1.1 ng TEQ (kg ash)−1 and 0.67 ng TEQ (kg ash)−1. There are now also sufficient published data available to evaluate EFs for dl-PCB release to air for sugarcane, forest and grass/savannah; these are 0.03 μg TEQ (t fuel)−1, 0.09 μg TEQ (t fuel)−1 and 0.01 μg TEQ (t fuel)−1, respectively. The average EF for dl-PCB release to land is 0.19 ng TEQ (kg ash)−1. Application of these EFs to national emissions of PCDD/PCDF for global estimates from open burning will lower previous estimates of PCDD/PCDF releases to air and to land by 85% and 90%, respectively. For some countries, the ranking of their major sources will be changed and open burning of biomass will become less significant than previously concluded.  相似文献   

9.
A new semi-empirical, approximate theory for predicting electrical conditions is described. In the approximate theory, analytical expressions are derived for calculating voltage-current characteristics and electric potential, electric field, and space charge density distributions. Comparisons of numerical and approximate solutions over a wide range of possible precipitator geometries and electrical operating points indicates that for practical purposes the approximate theory can be used in lieu of the more rigorous numerical theory. This saves large amounts of computer time and makes possible hand calculator usage. Recent in situ gaseous ion mobility data which are needed in the models are presented. For coal fired power plants, the reduced effective ion mobility in positive corona is found to be 1.6 times that for negative corona. Approaches for describing particulate space charge effects in the gas and electrical conditions in the collected particulate layer are briefly discussed.  相似文献   

10.
11.
负外部成本内部化约束下的煤炭开采税费水平研究   总被引:1,自引:0,他引:1  
煤炭开采中面临严重的代际负外部性和生态环境负外部性问题,分别运用使用者成本法和直接市场法测算了煤炭资源开采中的代际负外部成本和生态环境负外部成本。根据两个负外部成本充分内部化的要求,提出煤炭开采中税费水平的调整目标。以2008年为例,煤炭开采中资源税的征收标准应由目前的从量0.3-5元/t(约从价1%)提至从价10%;开采吨煤应交的生态环境费用标准应由目前的24元/t提至64.23-68.47元/t,即每吨提高40.23-44.47元。综合资源税和生态环境费用的提高幅度,煤炭开采活动中的税费水平应提高约21-22个百分点;通过比较现行税费制度下煤炭开采企业实交的资源税费、生态环境税费总额与企业应交的资源、生态环境费用总额之间的差距,指出目前我国政府对开采企业隐性税费补贴的规模水平,根据价差法计算得出取消此部分税费补贴将可以削减3 653.69万tCO2排放。  相似文献   

12.
The opacity and emission performance of two “identical” cold-side precipitators at a power plant utilizing a Western coal source was investigated through an extensive test program. The test program included establishment of outlet emission versus opacity correlations for the two “identical” units, correlation of rapper strategy (frequency and amplitude) with opacity, and correlation of power-off rapping strategy with opacity. Analysis of the test program data demonstrates that the opacity-emission correlations from the two “identical” units can be significantly different. The potential reasons for the differences between the two units are identified and examined in light of the test program data. Strong correlation of opacity with rapping strategy was developed from the test program. Results demonstrate that an automatic power-off rapping technique can significantly enhance precipitator performance on ash from Western coal.  相似文献   

13.
This study focuses on analyses of greenhouse gas (GHG) emission reductions, from the perspective of interrelationships among time points and countries, in order to seek effective reductions. We assessed GHG emission reduction potentials and costs in 2020 and 2030 by country and sector, using a GHG emission reduction-assessment model of high resolution regarding region and technology, and of high consistency with intertemporal, interregional, and intersectoral relationships. Global GHG emission reduction potentials relative to baseline emissions in 2020 are 8.4, 14.7, and 18.9 GtCO2eq. at costs below 20, 50, and 100 $/tCO2eq., corresponding to +19, −2, and −7 %, respectively, relative to 2005. The emission reduction potential for 2030 is greater than that for 2020, mainly because many energy supply and energy-intensive technologies have long lifetimes and more of the current key facilities will be extant in 2020 than in 2030. The emission reduction potentials in 2030 are 12.6, 22.0, and 26.6 GtCO2eq. at costs below 20, 50, and 100 $/tCO2eq., corresponding to +19, −2, and −7 %, respectively, relative to 2005. The emission reduction potential for 2030 is greater than that for 2020, mainly because many energy supply and energy-intensive technologies have long lifetimes and more of the current key facilities will be extant in 2020 than in 2030. The emission reduction potentials in 2030 are 12.6, 22.0, and 26.6 GtCO2eq. at costs below 20, 50, and 100 /tCO2eq., corresponding to +33, +8, and −3 %, respectively, relative to 2005. Global emission reduction potentials at a cost below 50 $/tCO2eq. for nuclear power and carbon capture and storage are 2.3 and 2.2 GtCO2eq., respectively, relative to baseline emissions in 2030. Longer-term perspectives on GHG emission reductions toward 2030 will yield more cost-effective reduction scenarios for 2020 as well.  相似文献   

14.
The subject of the study covered volatile ashes created during hard coal burning process in ash furnaces, in power plants operating in the Upper Silesian Industrial Region, Southern Poland. Coal-fired power plants are furnished with dust extracting devices, electro precipitators, with 99-99.6% combustion gas extracting efficiency. Activity concentrations ofTh-232, Ra-226, K-40, Ac-228, U-235 and U-238 were measured with gamma-ray spectrometer. Concentrations of selected rare soil elements (La, Ce, Nd, Sm, Y, Gd, Th, U) were analysed by means of instrumental neutron activation analysis (INAA). Mineral phases of individual ash particles were identified with the use of scanning electron microscope equipped with EDS attachment. Laser granulometric analyses were executed with the use of Analyssette analyser. The activity of the investigated fly-ash samples is several times higher than that of the bituminous coal samples; in the coal, the activities are: 226Ra - 85.4 Bq kg−1, 40 K-689 Bq kg−1, 232Th - 100.8 Bq kg−1, 235U-13.5 Bq kg−1, 238U-50 Bq kg−1 and 228Ac - 82.4 Bq kg−1.  相似文献   

15.
Fabric filtration systems have been employed in industry for over a century with relatively few technological modifications. However, with the recent substantial increase in energy costs, conservation in energy consumption has become vitally important. As a result, the filtration systems of yesteryear may not be the best approach for future applications. Recently, an external electrical field was considered in fabric filtration of industrial dust with very promising initial results. An increase in the collection efficiency, particularly for fine particulates, and a decrease in the pressure drop was observed. In this paper the further results of an experimental program in the investigation of pressure drop in the electrostatic fabric filtration in industrial dust control are presented. The basic apparatus, a bench-scale electrostatic fabric filtration system, creates a representative dust cake under specific conditions of operating parameters and charge levels. The results clearly indicate that filter and dust cake resistance, or pressure drop, decreases substantially with the increased electrostatic field strength for all industrial dust samples tested, regardless of fabric type and other relevant parameters.  相似文献   

16.
The Ceilcote ionizing wet scrubber installed on a refractory brick kiln was evaluated with tests involving particulate mass emission, particle size distribution, and opacity. The overall efficiency was 93% with an average outlet opacity of 8% on a 1.68 m (5.5 ft) path length. The average particle cut diameter of the scrubber is 0.5 microns with a theoretical power input of 67 W/am3 (2.5 hp/1000 acfm). The theoretical power requirement for the ionizing wet scrubber was 41 W/am3 (1.54 hp/1000 acfm). A cooling tower supplying chilled water to the prescrubber required an additional 26 W/am2 (0.96 hp/1000 acfm) for a total system input of 67 W/am3 (2.5 hp/1000 acfm). It is recommended that the scrubber be considered where practical for the removal of fine particulate matter.  相似文献   

17.
Although the “two stage” electrostatic precipitator concept was first developed in 1910, until recently most of their use was confined to in-plant air cleaning. In the last decade, plate type designs have been modified to make them suitable for industrial applications involving organic emissions, most notably in asphalt saturating, plastic curing, food processing, printing, textile finishing, and heat treating industries. However, plate type designs are inadequate in applications where very high loading and/or high particulate content are involved.Tubular design with wider spacing and higher voltages incorporates the best features of both the single stage and two stage type precipitators. These units have been used in molybdenum roasting, zirconium calcining, ammonia scrubbing of oxides of sulfur, meat broiling, foundry exhaust, etc.The paper discusses design parameters, field test data, and operating data on these units. Comparisons with single-stage type precipitators are made wherever applicable. Advantages and disadvantages of two stage precipitators are also discussed.  相似文献   

18.
Under the pressure of sustained growth in energy consumption in China, the implementation of a carbon pricing mechanism is an effective economic policy measure for promoting emission reduction, as well as a hotspot of research among scholars and policy makers. In this paper, the effects of carbon prices on Beijing’s economy are analyzed using input–output tables. The carbon price costs are levied in accordance with the products’ embodied carbon emission. By calculation, given the carbon price rate of 10 RMB/t-CO2, the total carbon costs of Beijing account for approximately 0.22–0.40% of its gross revenue the same year. Among all industries, construction bears the largest carbon cost. Among export sectors, the coal mining and washing industry has much higher export carbon price intensity than other industries. Apart from traditional energy-intensive industries, tertiary industry, which accounts for more than 70% of Beijing’s economy, also bears a major carbon cost because of its large economic size. However, from 2007 to 2010, adjustment of the investment structure has reduced the emission intensity in investment sectors, contributing to the reduction of overall emissions and carbon price intensity.  相似文献   

19.
BackgroundEpidemiological studies have associated long-term exposure to ambient particulate matter with increased mortality from cardiovascular and respiratory disorders. Systemic inflammation is a plausible biological mechanism behind this association. However, it is unclear how the chemical composition of PM affects inflammatory responses.ObjectivesTo investigate the association between long-term exposure to elemental components of PM and the inflammatory blood markers high-sensitivity C-reactive protein (hsCRP) and fibrinogen as part of the European ESCAPE and TRANSPHORM multi-center projects.MethodsIn total, 21,558 hsCRP measurements and 17,428 fibrinogen measurements from cross-sections of five and four cohort studies were available, respectively. Residential long-term concentrations of particulate matter < 10 μm (PM10) and < 2.5 μm (PM2.5) in diameter and selected elemental components (copper, iron, potassium, nickel, sulfur, silicon, vanadium, zinc) were estimated based on land-use regression models. Associations between components and inflammatory markers were estimated using linear regression models for each cohort separately. Cohort-specific results were combined using random effects meta-analysis. As a sensitivity analysis the models were additionally adjusted for PM mass.ResultsA 5 ng/m3 increase in PM2.5 copper and a 500 ng/m3 increase in PM10 iron were associated with a 6.3% [0.7; 12.3%] and 3.6% [0.3; 7.1%] increase in hsCRP, respectively. These associations between components and fibrinogen were slightly weaker. A 10 ng/m3 increase in PM2.5 zinc was associated with a 1.2% [0.1; 2.4%] increase in fibrinogen; confidence intervals widened when additionally adjusting for PM2.5.ConclusionsLong-term exposure to transition metals within ambient particulate matter, originating from traffic and industry, may be related to chronic systemic inflammation providing a link to long-term health effects of particulate matter.  相似文献   

20.
Surficial sediments and mussels (Mytilus galloprovincialis) from the Istanbul Strait and Marmara Sea were analysed for sixteen parent polycyclic aromatic hydrocarbon (PAH) contents by gas chromatography-mass spectrometry (GC-MS) employing isotope dilution technique. Microalgae toxicity testing was applied to sediment elutriates and biological responses in terms of filtration rate and lysosomal stability were measured in mussels. Total PAH concentrations ranged from 2.1 to 3152 ng g? 1 dry wt in sediments and from 43–601 ng g? 1 wet weight in mussels. Molecular indices of phenanthrene/ anthracene, fluoranthene/pyrene and benzo(a)anthracene/chrysene were used to differentiate between pyrolytic and petroleum origin. Results showed that most of the contamination originates from high temperature pyrolytic inputs with some slight contribution of petrogenic PAH. PAH in sediments were frequently lower than the National Oceanic and Atmospheric Administration (NOAA)–ERM (Effects Range Medium) index. Results of sediment elutriate toxicity testing and biomarkers indicate that the cause of negative effects in sediments may result from different classes of pollutants and does not only relate with PAH contamination. Mussels from most of the stations showed both reduced lysosomal membrane stability and filtration rate indicating disturbed health although the two biomarker results did not always complement each other. The effect studies showed that the pollutants in the strait ecosystem have more pronounced effects in the middle parts than those at the Black Sea entrance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号