首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Resuspended street dust is a source of inhalable particles in urban environments. Despite contaminated street dust being a possible health risk factor for local population, little is known about the contribution of atmospheric dust emissions and other factors to the content of toxic metals in street dust. The impact of smelting, traffic, and power plants on metal contaminates in street dust is the focus of street dust sampling at 46 locations in the Witbank area (Republic of South Africa). This area is characterized by numerous open-pit coal mines in the Karoo coal basin, which provides a cheap source of energy to numerous metallurgical smelters and ironworks and supplies coal to the coal-fired power plants located nearby. Street dust was collected on asphalt or concrete surfaces with hard plastic brushes, avoiding collecting of possible sand, soil, or plant particles. Chemical analysis was done on the <0.125 mm fraction using inductively coupled plasma mass spectrometry subsequent to total digestion. Exceptionally high concentrations of metals were detected with concentrations of Fe reaching 17.7 %, Cr 4.3 %, Mn 2 %, Ni 366 mg/kg, and V 4,410 mg/kg. Factor analysis indicates three sources for the pollution. Road traffic which contributes to the high concentrations of Cu, Pb, Sb, and Sn, with the highest impacts detected in the town of Witbank. The second source is associated with the metal smelting industry, contributing to Fe, Co, Mn, and V emissions. The highest factor scores were observed around four metallurgical smelter operations, located in the Ferrobank, Highveld, and Clewer industrial areas. Impact of vanadium smelter to street dust composition could still be detected some 20 km away from the sources. Exceptionally high concentrations of Cr were observed in four samples collected next to the Ferrobank industrial area, despite Cr not being loaded in factor 2. The last source of the pollution is most probably fly ash associated with the coal-fired power plants and fly ash dumps. Elements which are associated with this source are Al, Sr, and Li. This factor is abundant in the coal mining part of the study area.  相似文献   

2.
The Lurgi-MB-Filler collects dust from industrial gases by mechanical means in a dry state. It works in continuous operation at temperatures up to 660°F with high dust collecting efficiencies and a low draft loss. The gas to be cleaned passes through a filter bed consisting of abrasion resisting material such as gravel, etc. The captured dust is removed from the filter bed by a patented vibrating system which shakes the spring supported filter bed containers. Simple design and automatic operation ensure low investment and operating costs and give an economic superiority in the fields of cleaning waste air from clinker coolers, conveyors, crushers, pulverizing mills, driers, and preparation plants.  相似文献   

3.
Huber S  Haug LS  Schlabach M 《Chemosphere》2011,84(11):1686-1693
Polyfluorinated compounds (PFCs) are an extremely versatile class of compounds and are used in a variety of consumer applications and products. Recent studies have suggested that PFCs in indoor air and dust could act as sources of human exposure and outdoor air contamination. This study presents method development and analysis of a wide range of PFCs in dust and air using active sampling techniques with commercially available sampling equipment (forensic nozzles with filter housings for dust collection and polyurethane foam (PUF)-XAD2-PUF sandwich-tubes for air sampling) using both liquid and gas chromatography mass spectrometry. The developed method was validated and tested for applicability to analyze dust and air samples at both low and high concentrations (0.5 ng and 25 ng per analyte per air sample, respectively). Samples from private households and an office building were analyzed to explore differences in distribution patterns and concentrations. Perfluorooctane sulfonate, perfluorodecane sulfonate, perfluoroheptanoate, perfluorooctanoate and perfluorononanoate were observed in all samples of dust from private households, in the range from 1 to 80.1 ng g−1. Fluorotelomer alcohols (FTOHs) were the predominant PFCs in indoor air samples with ∑FTOHs ranging between 4.7 and 17.9 ng m−3. The concentrations found in the present study are generally lower than those previously reported. This variation may be due to differences associated with geographical locations and lifestyles. However, use of different sampling techniques and strategies among studies can introduce large variations in PFC concentration found, making direct comparisons challenging.  相似文献   

4.
Strategies for sustainable woodland on contaminated soils   总被引:5,自引:0,他引:5  
Dickinson NM 《Chemosphere》2000,41(1-2):259-263
  相似文献   

5.
滤料负载粉尘层对气态汞脱除性能的实验研究   总被引:1,自引:0,他引:1  
通过不同性能纤维滤料负载燃煤飞灰粉尘层,来模拟袋式除尘器滤袋表面粉尘附着层,进而研究袋滤器用不同性能纤维滤料和粉尘附着层对燃煤烟气中Hg0的联合脱除性能。在固定床实验系统上分别进行了不同纤维滤料和燃煤飞灰粉尘层,以及经实验优选得到的华博特滤料负载燃煤飞灰粉尘层脱除燃煤烟气中Hg0的实验研究。结果表明,燃煤飞灰粉尘层和华博特滤料对Hg0分别有一定的脱除作用,脱除效率可达35%和42.5%,它们对Hg0的脱除是物理吸附和化学吸附共同作用的结果;同时,华博特滤料负载燃煤飞灰粉尘层对Hg0的联合脱除效率受到吸附反应温度、入口汞浓度和烟气停留时间等因素的影响,最佳脱汞率可达64.4%;吸附反应温度越高,脱除效率越低;烟气停留时间越大,脱除效率越高;入口汞浓度的提高并不一定提高华博特滤料负载飞灰粉尘层的脱汞效果。  相似文献   

6.
On November 18, 1997, above-road particulate matter (PM) lidar (light detection and ranging) signals and heavy-duty (HD) and light-duty (LD) vehicle counts were simultaneously collected for 894 10-sec sampling periods at the Caldecott Tunnel in Orinda, CA, for the purpose of measuring the relative contributions of LD and HD vehicles to the PM lidar signal under real-world driving conditions. The relationship between the PM lidar signal and traffic activity (i.e., LD and HD traffic volumes) was examined using a time-series analysis technique, multilagged regression. The time-series model results indicate that the PM lidar signal in the current sampling period (PMt) depended on the level recorded in the previous three sampling periods (i.e., PMt-1, PMt-2, and PMt-3), the number of LD vehicles in the seventh past sampling period (LDt-7), and the number of HD vehicles measured 80 sec previous to the current sampling period (HDt-8). On a 10-sec period basis, the model results indicate that HD vehicles contributed, on average, 3 times more to above-road PM lidar signals than did LD vehicles. The observed lag in the relationship between vehicle types and the lidar signal 20 m above the road suggests that resuspended road dust, rather than tailpipe exhaust emissions, was the main source of the detected PM. Detection of road dust at such heights above the road suggests the need for investigating the processes governing the vertical transport and recycling of PM over the road as a function of vehicle dynamics under a range of meteorological conditions.  相似文献   

7.
Application of greenwaste compost to brownfield land is increasingly common in soil and landscape restoration. Previous studies have demonstrated both beneficial and detrimental effects of this material on trace element mobility. A pot experiment with homogenised soil/compost investigated distribution and mobility of trace elements, two years after application of greenwaste compost mulch to shallow soils overlying a former alkali-works contaminated with Pb, Cu and As (∼900, 200 and 500 mg kg−1, respectively). Compost mulch increased organic carbon and Fe in soil pore water, which in turn increased As and Sb mobilization; this enhanced uptake by lettuce and sunflower. A very small proportion of the total soil trace element pool was in readily-exchangeable form (<0.01% As, <0.001% other trace elements), but the effect of compost on behaviour of metals was variable and ambiguous. It is concluded that greenwaste compost should be applied with caution to multi-element contaminated soils.  相似文献   

8.
The past decade has seen substantial policy effort directed at promoting the reclamation and reuse of urban brownfield or potentially contaminated land. This paper is based on the results of a survey regarding the role of stakeholder attitudes in managing contaminated sites at the Romanian level. Findings indicate that effective policies and programmes need to be framed within an understanding of the different needs of national development. While different perceptions were identified in regard to the meanings of several concepts and terms used in this field, important aspects related to the need for developing a correctly ranked and coordinated decision-making process were also identified. Additional findings indicate gaps in the legal mechanisms intended to promote brownfield rehabilitation in the course of redevelopment. At the same time, the survey respondents suggested several recommendations such as the necessity of developing a risk assessment to establish the level and extent of contamination that can endanger human health and the environmental integrity on a site and also the need for greater compatibility between land-use planning processes and environmental legislation related to contaminated site management. The paper presents general conclusions engaging all the recommendations drawn from the survey questionnaire as well as from the general current situation in Romania.  相似文献   

9.
ABSTRACT

On November 18, 1997, above-road particulate matter (PM) lidar (light detection and ranging) signals and heavy-duty (HD) and light-duty (LD) vehicle counts were simultaneously collected for 894 10-sec sampling periods at the Caldecott Tunnel in Orinda, CA, for the purpose of measuring the relative contributions of LD and HD vehicles to the PM lidar signal under real-world driving conditions. The relationship between the PM lidar signal and traffic activity (i.e., LD and HD traffic volumes) was examined using a time-series analysis technique, multilagged regression. The time-series model results indicate that the PM lidar signal in the current sampling period (PMt) depended on the level recorded in the previous three sampling periods (i.e., PMt-1, PMt-2, and PMt-3), the number of LD vehicles in the seventh past sampling period (LDt-7), and the number of HD vehicles measured 80 sec previous to the current sampling period (HDt-8). On a 10-sec period basis, the model results indicate that HD vehicles contributed, on average, 3 times more to above-road PM li-dar signals than did LD vehicles. The observed lag in the relationship between vehicle types and the lidar signal 20 m above the road suggests that resuspended road dust, rather than tailpipe exhaust emissions, was the main source of the detected PM. Detection of road dust at such heights above the road suggests the need for investigating the processes governing the vertical transport and recycling of PM over the road as a function of vehicle dynamics under a range of meteorological conditions.  相似文献   

10.
Approximately 750 total suspended particulates (TSPs) and coarse particulate matter (PM10) filter samples from six urban sites and a background site and >210 source samples were collected in Jiaozuo City during January 2002 to April 2003. They were analyzed for mass and abundances of 25 chemical components. Seven contributive sources were identified, and their contributions to ambient TSP/PM10 levels at the seven sites in three seasons (spring, summer, and winter days) and a "whole" year were estimated by a chemical mass balance (CMB) receptor model. The spatial TSP average was high in spring and winter days at a level of approximately 530 microg/m(3) and low in summer days at 456 microg/m(3); however, the spatial PMo0 average exhibited little variation at a level of approximately 325 microg/m(3), and PM10-to-TSP ratios ranged from 0.58 to 0.81, which suggested heavy particulate matter pollution existing in the urban areas. Apportionment results indicated that geological material was the largest contributor to ambient TSP/PM10 concentrations, followed by dust emissions from construction activities, coal combustion, secondary aerosols, vehicle movement, and other industrial sources. In addition, paved road dust and re-entrained dust were also apportioned to the seven source types and found soil, coal combustion, and construction dust to be the major contributors.  相似文献   

11.
Particle light scattering (Bsp) from nephelometers and fine particulate matter (PM2.5) mass determined by filter samplers are compared for summer and winter at 35 locations in and around California's San Joaquin Valley from December 2, 1999 to February 3, 2001. The relationship is described using particle mass scattering efficiency (sigmasp) derived from linear regression of Bsp on PM2.5 that can be applied to estimated PM2.5 from nephelometer data within the 24-hr filter sampling periods and between the every-6th-day sampling frequency. An average of sigmaSp = 4.9 m2/g was found for all of the sites and seasons; however, sigmasp averaged by site type and season provided better PM2.5 estimates. On average, the sigmasp was lower in summer than winter, consistent with lower relative humidities, lower fractions of hygroscopic ammonium nitrate, and higher contributions from fugitive dust. Winter average sigmasp were similar at non-source-dominated sites, ranging from 4.8 m2/g to 5.9 m2/g. The sigmasp was 2.3 m2/g at the roadside, 3.7 m2/g at a dairy farm, and 4.1 m2/g in the Kern County oilfields. Comparison of Bsp from nephelometers with and without a PM2.5 inlet at the Fresno Supersite showed that coarse particles contributed minor amounts to light scattering. This was confirmed by poorer correlations between Bsp and coarse particulate matter measured during a fall sampling period.  相似文献   

12.
建立了非稳态过滤下的固定床颗粒层除尘效率模型.该模型尽可能地包含了影响固定床颗粒层除尘的参数,反映了沉积粉尘对除尘效率的影响;研究了以粒状脱硫剂为滤料的固定床在不同颗粒层厚度、空床气速、粒径下的除尘效率.结果表明,在颗粒层厚度为400~800 cm、空床气速≤0.4 m/s的条件下,颗粒层的除尘效率可达90%以上.  相似文献   

13.
Ambient carbonaceous material collected on quartz filters is prone to measurement artifacts due to material gained or lost during post-sampling field latency, shipping, and storage. In seventeen sampling events over a one year period, ambient PM2.5 aerosols were collected on quartz filters (without denuders) and subjected to various filter treatments to assess the potential for and extent of artifacts. The filter treatments simulated post-sampling environments that filters may be exposed to and included: storage at 40 °C for up to 96 h, storage at ?16 °C for 48 h, and storage at room temperature (~21 °C) for 48 h. Carbon mass on the filters was measured using a thermal-optical method. The total carbon (TC), total organic carbon (TOC) and total elemental carbon (TEC) as well as carbon thermal fraction masses were obtained. Statistical analyses were performed to identify significant differences in carbon fraction concentrations between filters analyzed immediately after sampling and after being subjected to treatment.TOC and TC concentrations decreased by on average 15 ± 5% and 10 ± 4%, respectively, for filters maintained at 40 °C for 96 h but did not change for filters stored at room temperature or frozen for 48 h. TEC did not change for any of the filter treatments. The mass concentration for the organic carbon thermal fraction that evolves at the lowest temperature step (OC1) decreased with increasing storage time at 40 °C with average losses of 70 ± 7% after 96 h. Therefore, OC1 is not a stable measurement due to post-sampling conditions that may be encountered. This work demonstrates that TOC and TC can have substantial measurement artifacts on filters subjected to field latency and other non-temperature controlled post-sampling handling, compared to the carbon loadings on the filter at the end of the sampling period.  相似文献   

14.
试验研究了专利产品"高压静电滤槽复合型卧式除尘器"的除尘脱硫一体化工艺.试验表明,在布袋前方的末级电场中实行半干法脱硫工艺具有可行性,可达到除尘脱硫一体化目的.试验同时研究了钙硫比、脱硫灰循环率、饱和温距、喷水量和SO2浓度等对脱硫率的影响.该工艺适用于以低硫煤为燃料的锅炉进行除尘脱硫.  相似文献   

15.
道路径流SS和COD污染特征及出流规律   总被引:1,自引:0,他引:1  
选择芜湖市火车站点进行长期监测,采集降雨7次;同时选择5个不同功能区,采集典型降雨1次。探讨了道路径流中总固体悬浮物(SS)和化学需氧量(COD)的污染特征、影响因素及出流规律,结果表明,7次降雨事件SS和COD平均值范围分别为198~1 529 mg/L和66~367 mg/L。SS和COD污染较为严重。SS在不同功能区中大小顺序为:工业区>居民区>商业区>交通区>文教区,总COD大小顺序为:工业区>交通区>居民区>商业区>文教区,溶解态COD大小顺序为:工业区>交通区>商业区>文教区>居民区,颗粒态COD大小顺序为:工业区>居民区>交通区>文教区>商业区。工业活动对地表径流SS和COD含量影响最大。SS受降雨历时影响较大,溶解态COD受平均雨强影响较大,颗粒态COD受最大雨强影响较大。不同降雨强度下,SS、溶解态COD及颗粒态COD的出流规律不同,降雨强度对径流初期效应的影响显著。  相似文献   

16.
复合型除尘器除尘脱硫一体化工艺实验研究   总被引:2,自引:0,他引:2  
试验研究了专利产品“高压静电滤槽复合型卧式除尘器”的除尘脱硫一体化工艺。试验表明,在布袋前方的末级电场中实行半干法脱硫工艺具有可行性,可达到除尘脱硫一体化目的。试验同时研究了钙硫比、脱硫灰循环率、饱和温距、喷水量和SO2浓度等对脱硫率的影响。该工艺适用于以低硫煤为燃料的锅炉进行除尘脱硫。  相似文献   

17.
The determination of sixteen polycyclic aromatic hydrocarbons in urban street dust has been done. Samples were collected from 12 sampling locations in a city centre location (Newcastle upon Tyne, north east England) and extracted using in situ pressurised fluid extraction followed by gas chromatography mass spectrometry. From the results it was possible to identify three groups, with respect to PAH concentration, with PAH contents ranging between 0.6-2.3 mg kg−1, 15.6-22.5 mg kg−1 and 36.1-46.0 mg kg−1. The total PAH content of samples from these sampling sites has been compared to 22 urban locations around the world; comparable levels were found in these samples compared to the other cities around the world.The potential source of PAHs has been investigated by investigating the proportion of pyrogenic and petrogenic material in urban street dust using specific individual PAH ratios. The results indicate that the PAH content of urban street dust from the chosen sites are more likely to be due to pyrogenic sources i.e. vehicle exhaust emissions. The particle size fractions (<63 μm; 63-125 μm; 125-250 μm; 250-500 μm; 500-1000 μm; and 1000-2000 μm) of individual PAHs in three selected sampling sites was investigated. In two of the selected sites the PAH content was independent of particle size whereas in sampling site 10 elevated PAH levels are noted in the <63 μm size fraction. Sampling site 10 is located at the junction of three road tributaries which are used as major access points to the east of the city centre. Finally, the potential health risk for unintentional consumption of PAHs was assessed in terms of a mean daily intake (based on an ingestion rate of 100 mg d−1). It was found that all 4-6 membered ring PAHs had concentrations in excess of the mean daily intake thereby reflecting a potential health risk, particularly in the smallest size particle fractions.  相似文献   

18.
A detailed aerosol source apportionment study was performed with two sampling campaigns, during wintertime and summertime in the heavily polluted metropolitan area of São Paulo, Brazil. In addition to 12 h fine and coarse mode filter sampling, several real time aerosol and trace gas monitors were used. PM10 was sampled using stacked filter units that collects fine (d<2.5 μm) and coarse (2.5<d<10 μm) particulate matter, providing mass, black carbon (BC) and elemental concentration for each aerosol mode. The concentration of about 20 elements was determined using the particle induce X-ray emission technique. Real time aerosol monitors provided PM10 aerosol mass (TEOM), organic and elemental carbon (Carbon Monitor 5400, R&P) and BC concentration (Aethalometer). A complex system of sources and meteorological conditions modulates the heavy air pollution of the urban area of São Paulo. The boundary layer height and the primary emissions by motor vehicles controls the strong pattern of diurnal cycles obtained for PM10, BC, CO, NOx, and SO2. Absolute principal factor analysis results showed a very similar source pattern between winter and summer field campaigns, despite the different locations of the sampling sites of both campaigns, pointing that there are no significant change in the main air pollution sources. The source identified as motor vehicle represented 28% and 24% of the PM2.5 for winter and summer, respectively. Resuspended soil dust accounted for 25% and 30%. The oil combustion source represented 18% and 21%. Sulfates accounts for 23% and 17% and finally industrial emissions contributed with 5% and 6% of PM2.5, for winter and summer, respectively. The resuspended soil dust accounted for a large fraction (75–78%) of the coarse mode aerosol mass. Certainly automobile traffic and soil dust are the main air pollution sources in São Paulo. The sampling and analytical procedures applied in this study showed that it is possible to perform a quantitative aerosol source apportionment in a complex urban area such as São Paulo.  相似文献   

19.
Thermogravimetric analysis (TGA) has been combined with evolved gas analysis (EGA) with the purpose of simulating the thermal behaviour of filter dust samples under inert (desorption) and de novo test oxidising conditions. Emphasis is on studying de novo formation of dioxins, surrogates and precursors arising from filter dust derived from thermal processes, such as municipal solid waste incineration and metallurgy. A new method is tested for sampling and analysing dioxin surrogates and precursors in the TGA effluent, which are collected on sampling tubes; the adsorbed compounds are eventually desorbed and quantified by TD-GC-MS. The major sources of error and losses are considered, including potential sorbent artefacts, possible breakthrough of volatiles through sampling tubes, or eventual losses of semi-volatiles due to their incomplete desorption or re-condensation inside the TG Analyser. The method is optimised and validated for di- to hexa-chlorinated benzenes in a range of 10-1000ppb with average recovery exceeding 85%. The results are compared with data obtained in similar studies, performed by other research groups. As a result, the method provides the means for simulating de novo synthesis of dioxins in fly-ash and facilitates reliable and easy estimation of de novo activity, comparable with results of other studies, in combination with wide flexibility of testing conditions.  相似文献   

20.
A 6.6 ha grassland, established on a former chemical waste site adjacent to a residential area, contains arsenic (As) in surface soil at concentrations 200 times higher than UK Soil Guideline Values. The site is not recognized as statutory contaminated land, partly on the assumption that mobility of the metalloid presents a negligible threat to human health, groundwater and ecological receptors. Evidence for this is evaluated, based on studies of the effect of organic (green waste compost) and inorganic (iron oxides, lime and phosphate) amendments on As fractionation, mobility, plant uptake and earthworm communities. Arsenic mobility in soil was low but significantly related to dissolved organic matter and phosphate, with immobilization associated with iron oxides. Plant uptake was low and there was little apparent impact on earthworms. The existing vegetation cover reduces re-entrainment of dust-blown particulates and pathways of As exposure via this route. Minimizing risks to receptors requires avoidance of soil exposure, and no compost or phosphate application.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号