首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Although bacterial contamination is widely researched in dental unit water systems, we have been unable to find any published reports to date about the presence and distribution of sulphate-reducing bacteria (SRB) in dental unit waterlines (DUWLs). The aim of this study was to evaluate microbial contamination and to determine the presence and distribution of SRB in DUWLs. One hundred twenty-three water samples were collected from the air–water syringes, high-speed drills and water sources from 41 dental units in Istanbul, Turkey. The counts of aerobic heterotrophic bacteria and SRB were investigated in the water samples. In addition, the presence of free-living amoebae (FLA) was examined. In this work, we evaluated microbial contamination and reported for the first time the distribution of SRB in DUWLs. We determined that only ten out of 123 water samples were able to meet the American Dental Association’s limit (≤200 CFU ml − 1). SRB were observed in 102 out of 123 samples (82.9%). In addition, SRB were detected in all of the air–water syringes and high-speed drills. FLA were established in 103 out of 123 samples (83.7%).  相似文献   

2.
The aim of this study was to evaluate the bacterial contamination level and to determine the antibiotic susceptibility of the isolated bacteria from dental unit waterlines (DUWLs) in Istanbul. Bacterial quality of DUWLs is very important, as patients and dental staff are regularly exposed to water and aerosols generated by the unit. If opportunistic pathogens such as Staphylococcus aureus, Pseudomonas aeruginosa, and Legionella pneumophila are present in DUWLs, patient and dental staff can be infected. One hundred water samples were collected from high-speed drills and input waters from 50 dental units. Aerobic heterotrophic bacteria counts and the presence of Legionella, Pseudomonas, oral streptococci, and Staphylococcus were investigated in dental unit waters and aerosol samples. In addition, the antibiotic susceptibility of the isolated and identified bacteria from DUWLs was examined. This research found that 37 out of 50 dental unit water samples exceeded the American Dental Association’s limit of 200 colony-forming units (CFU)/mL?1. Legionella, oral streptococci, and S. aureus were not detected in any water or aerosol samples, but P. aeruginosa was isolated in three DUWLs. Also, Pseudomonas and Staphylococcus were found in water and aerosol samples. Cefoperazone, ofloxacin, gentamicin, ciprofloxacin, and piperacillin were the most effective antibiotics against the isolated bacteria from DUWLs.  相似文献   

3.
The microbiological quality in dental unit waterlines (DUWLs) is considered to be important because patients and dental staff with suppressed immune systems are regularly exposed to water and aerosols generated from dental units (DUs). Opportunistic pathogens like Pseudomonas, Legionella, Candida, and Aspergillus can be present in DUWLs, while during consultations, bioaerosols can be dispersed in the air, thus resulting in effects on microbiological quality of indoor air. This present study represents microbiological air and water quality in dental offices (DOs) and also concerns the relationship between the quality of DO air and dental unit water. This study aimed to assess both the microbial quality of dental unit water and the indoor air in 20 DOs and to survey the effect on the quality of the indoor air with the existing microorganisms in dental unit water. Fourteen out of 20 (70 %) DUWLs were found to be contaminated with a high number of aerobic mesophilic heterotrophic bacteria. In terms of bacterial air contamination levels, in 90 % of DOs, a medium level (<500 colony-forming units (CFU)/m3) of contamination was determined, while in terms of microfungal air contamination, in all DOs, a low level (<100 CFU/m3) of contamination was determined. Potential infection or allergen agents, such as Pseudomonas, Micrococcus, Staphylococcus, Alternaria, Cladosporium, Penicillium, Aspergillus, and Paecilomyces were isolated from water and air samples. This study’s determination of contamination sources and evaluation of microbial load in DOs could contribute to the development of quality control methods in the future.  相似文献   

4.
Safety of patients and dental personnel requires the appropriate microbiological water quality in dental units. During treatment, patients and dental workers are exposed both to direct contact with bacteria-contaminated water in the form of splatter and with contaminated water aerosol emitted during work by unit handpieces, including rotating and ultrasonic instruments. The aim of the study was to determine the qualitative and quantitative contamination of water in dental unit reservoirs with aerobic and facultative anaerobic bacteria. The study material included water sampled from 107 dental unit reservoirs located in dental surgeries of public health centres. Conventional microbiological methods were used to identify microorganisms. The study shows that the contamination of water in dental unit reservoirs with aerobic and facultative anaerobic bacteria is commonplace. The mean concentration of mesophile bacteria in dental unit reservoir water exceeded 1.1?×?105 cfu/ml. The prevailing species were Gram-negative bacteria of the families Burkholderiaceae, Pseudomonadaceae, Ralstoniaceae and Sphingomonadaceae. The most numerous bacteria were Ralstonia pickettii, constituting 49.33 % of all the identified aerobic and facultative anaerobic bacteria. Among Gram-positive rods, the most numerous were bacteria of the genus Brevibacterium (5.83 %), while the highest percentage shares (13.25 %) of all Gram-positive microorganisms were found for Actinomyces spp. The study confirms the necessity of regular monitoring of microbial contamination of dental unit waterlines (DUWL) and use of various water treatment procedures available to disinfect DWUL.  相似文献   

5.
This is a cross-sectional study of the incoming and distal outlet water quality from 41 dental units in Istanbul, carried out to compare the total microbial loads using traditional culture method versus epifluorescence microscopy. The possible presence of Legionella pneumophila using traditional culture method was also analyzed. One hundred and twenty three samples were taken from the high-speed handpiece lines, air-water syringe lines and source (incoming) water supplies from 41 dental units. The samples were assayed for live/dead bacteria, heterotrophic bacterial counts and presence of L. pneumophila bacteria. Thirty nine out of 41 dental units (91%) were not able to meet the standard limit of 200 CFU/ml in dental unit waters. The live bacterial counts were 1-1.5 orders of magnitude higher than aerobic mesophilic heterotrophic bacteria. L. pneumophila (serogroup 2-14) was isolated from five out of 41 units. Some dental units were using commercially bottled (19 l) drinking water as a source. The source water of eight dental unit was heavily contaminated which were fed up by commercially bottled drinking water.  相似文献   

6.
The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium–low level of bacterial contamination (50–500 CFU/m3) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.  相似文献   

7.
Microbiological quality of crude oil storage tanks was determined. The samples were taken from crude oil storage tanks in three stations, at Ughelli, Escravos and Forcados tank farms in the Delta State of Nigeria. Two tanks were sampled at each station with samples collected from three levels of the tank, namely the oil layer, oil water interface, and effluent layer. Samples from the inner walls and bottom sediment of the only empty tank in Ughelli during the study were also taken. The total heterotrophic count of bacteria and total fungal count were obtained by plating samples on nutrient agar and sabouraud's glucose agar respectively and incubated for 14 days at 28 °C±2 °C. Oilutilizing bacteria and fungi were isolated on oil agar using fungizone and antibiotics to inhibit fungal and bacterial growth respectively. Pure cultures of bacteria and fungi were prepared on nutrient agar and sabouraud's glucose agar respectively at 28 °C±2 °C for 4 days. Isolates were identified using approved standard methods. Three bacterial genera, Pseudomonas, Proteus and Bacillus, and one actinomycete, Actinomyces and two fungal genera, Penicillium and Cunninghamella, were isolated. Pseudomonas was dominant among the bacteria (41.62%) and Penicillium dominant among the fungi (94%). It was also found that the total microbial load of the effluent layer was higher than that of the oil layer.  相似文献   

8.
The removal and recovery of heavy metals from a coal pilerunoff water using a mixture of multiple metal-tolerantbacterial strains of ATCC 55673, and ATCC 55674 and a Pseudomonas sp. was investigated. The analysis of elementalcomposition of metal precipitates recovered from the bacterialbiomass by transmission electron microscopy and energy dispersiveX-ray analysis revealed the presence of metals originally presentin the wastewater. In addition, analysis of metals in culturesupernatant and bacterial biomass by inductively coupled plasmaemission spectroscopy (ICP-ES) indicated a removal range of 82-100% and a recovery of 15-58% of metals from the wastewater and bacterial biomass, respectively.  相似文献   

9.
Faecal contamination is a major causative factor for incidence of water borne infectious diseases. Certain hydrogen sulfide (H2S) producing enteric bacteria such as Salmonella sp. and Citrobacter sp., assosiated with coliforms, have been considered for rapid detection of recent faecal contamination in water. The basic H2S test medium, modified by adding 0.25 gm/L of L-cystine HCl, was examined for its efficiency with 90 water samples collected from 40 pipe supplies, 20 open wells, 15 hand pumps and 15 different surface water bodies (river, streams and ponds). Sterilized modified culture medium in glass vials was inoculated with 100 mL of each sample and incubated at 20, 25, 30, 35 and 44 C for 18, 24, 42, 48, 66 and 72 h. Blackening of content in incubated vials was considered positive. For comparison, most probable number (MPN) of coliform and faecal coliform per 100 mL was also estimated in each sample by multiple tube fermentation (MTF) method. H2S positive result was exhibited by 78% of samples. Coliform (> 10) and faecal coliform/100 mL were also detected in 59% of samples. Maximum H2S positive results (100%) were found with well and surface water samples incubated at 30, 35 and 44 C for 18 h. Coliform (> 10) and faecal coliform/100 mL were also detected in most of these samples. Pipe supplies (60%) and hand pumps (73%) also exhibited considerable H2S production. Coliforms and faecal coliforms were also found in significant number of these samples. Thus, the modified H2S test may prove a useful alternative indicator of faecal contamination for water quality surveillance and screening of large number of water samples in short duration, particularly during any outbreak of water borne disease among rural population.  相似文献   

10.
Samples of soil, water, and sediments from industrial estates in Lagos were collected and analyzed for heavy metals and physicochemical composition. Bacteria that are resistant to elevated concentrations of metals (Cd2?+?, Co2?+?, Ni2?+?, Cr6?+?, and Hg2?+?) were isolated from the samples, and they were further screened for antibiotic sensitivity. The minimum tolerance concentrations (MTCs) of the isolates with dual resistance to the metals were determined. The physicochemistry of all the samples indicated were heavily polluted. Twenty-two of the 270 bacterial strains isolated showed dual resistances to antibiotics and heavy metals. The MTCs of isolates to the metals were 14 mM for Cd2?+?, 15 mM for Co2?+? and Ni2?+?, 17 mM for Cr6?+?, and 10 mM for Hg2?+?. Five strains (Pseudomonas aeruginosa, Actinomyces turicensis, Acinetobacter junni, Nocardia sp., and Micrococcus sp.) resisted all the 18 antibiotics tested. Whereas Rhodococcus sp. and Micrococcus sp. resisted 15 mM Ni2?+?, P. aeruginosa resisted 10 mM Co2?+?. To our knowledge, there has not been any report of bacterial strains resisting such high doses of metals coupled with wide range of antibiotics. Therefore, dual expressions of antibiotics and heavy-metal resistance make the isolates, potential seeds for decommissioning of sites polluted with industrial effluents rich in heavy metals, since the bacteria will be able to withstand in situ antibiosis that may prevail in such ecosystems.  相似文献   

11.
A total of 176 (water and sediment) samples from 22 stations belonging to four different (urban, semi-urban, rural, and holy places) human habitations of Tamil Nadu beaches were collected and analyzed for physiochemical and microbial parameters during 2008–2009. Bacterial counts were two- to tenfold higher in sediments than in water due to strong bacterial aggregations by dynamic flocculation and rich organic content. The elevated bacterial communities during the monsoon explain rainfalls and several other wastes from inlands. Coliform counts drastically increased at holy and urban places due to pilgrimage and other ritual activities. Higher values of the pollution index (PI) ratio (>1) reveals, human fecal pollutions affect the water quality. The averaged PI ratio shows a substantial higher microbial contamination in holy places than in urban areas and the order of decreasing PI ratios observed were: holy places?>?urban areas?>?semi-urban areas?>?rural areas. Correlation and factor analysis proves microbial communities were not related to physicochemical parameters. Principal component analysis indicates 55.32 % of the total variance resulted from human/animal fecal matters and sewage contaminants whereas 19.95 % were related to organic contents and waste materials from the rivers. More than 80 % of the samples showed a higher fecal coliform and Streptococci by crossing the World Health Organization's permissible limits.  相似文献   

12.
Legionella pneumophila (L. pneumophila) which is also known as etiologic agent Legionnaires Disease lives in natural water and man made water systems. These bacteria belonging to Legionellaceae family are divided 15 serogroups. Phenotypical methods used for the identification of Legionella isolates are not very discriminatory. In this study we investigated genotypic features of eight L. pneumophila serogroup 1 and 18 L. pneumophila serogroup 2-14 strains isolated from different buildings in Istanbul by randomly amplified polymorphic DNA (RAPD) method. Eight L. pneumophila serogroup 1 strains (37.5%) were similar RAPD profile and they were isolated from buildings located in a short distance (about 500 m). Four L. pneumophila serogroup 2-14 strains (22%) were identical genotypically. Three of these strains were isolated from buildings located in a short distance.  相似文献   

13.
14.
Prolonged moisture on building materials can lead to microbial growth on them. Microbes can emit spores, metabolites and structural parts into the indoor air and thus, cause adverse health effects of people living and working in these buildings. So far, culture methods have been used for assessment of microbial contamination of building materials. In this work, we used quantitative PCR (qPCR) for the detection of selected fungal and bacterial groups in 184 building materials of different types and compared the results with culture-based analysis. Nine either commonly found species, genera or groups of fungi, or those considered as moisture damage indicators, and one bacterial genus, Streptomyces, were determined using qPCR. Fungi and mesophilic actinomycetes were also cultivated using standard media and conditions of the routine analysis. The bacterial genus Streptomyces and the fungal group Penicillium/Aspergillus/Paecilomyces were the most prevalent microbial groups in all building material types, followed by Stachybotrys chartarum and Trichoderma viride/atroviride/koningii. The highest prevalences, concentrations and species diversity was observed on wooden materials. In general, the results of the two methods did not correlate well, since concentrations of fungi and streptomycetes were higher and their occurrence more prevalent when determined by qPCR compared to culture-based results. However, with increasing concentrations, the correlation generally increased. The qPCR assay did not detect Aspergillus versicolor and Acremonium strictum as often as culture.  相似文献   

15.
Chromium (VI) [Cr (VI)] biosorption by four resistant autochthonous bacterial strains was investigated to determine their potential for use in sustainable marine water-pollution control. Maximum exchange between Cr (VI) ions and protons on the cells surfaces were at 30–35 °C, pH?2.0 and 350–450 mg/L. The bacterial strains effectively removed 79.0–90.5 % Cr (VI) ions from solution. Furthermore, 85.3–93.0 % of Cr (VI) ions were regenerated from the biomasses, and 83.4–91.7 % of the metal was adsorbed when the biomasses was reused. Langmuir isotherm performed better than Freundlich isotherm, depicting that Cr (VI) affinity was in the sequence Rhodococcus sp. AL03Ni?>?Burkholderia cepacia AL96Co?>?Corynebacterium kutscheri FL108Hg?>?Pseudomonas aeruginosa CA207Ni. Biosorption isotherms confirmed that Rhodococcus sp. AL03Ni was a better biosorbent with a maximum uptake of 107.46 mg of Cr (VI) per g (dry weight) of biomass. The results highlight the high potential of the organisms for bacteria-based detoxification of Cr (VI) via biosorption.  相似文献   

16.
Bermuda is a densely populated coral 'atoll' located on a seamount in the mid-Atlantic (Sargasso Sea). There is no national sewerage system and the ~20 × 10(6)?L of sewage generated daily is disposed of via marine outfalls, cess pits/septic tanks underneath houses and through waste disposal (injection) wells. Gastrointestinal (GI) enterococci concentrations were measured in surface seawater samples collected monthly at multiple locations across the island over a 5-year period. According to the EU Bathing Water Directive microbial classification categories, 18 of the sites were in the 'excellent' category, four sites in the 'good', five sites were in the 'sufficient' and three sites in the 'poor' categories. One of the sites in the 'poor' category is beside a popular swimming beach. Between 20-30% of 58 sub tidal sediment samples collected from creeks, coves, bays, harbours and marinas in the Great Sound complex on the western side of Bermuda tested positive for the presence of the human specific bacterial biomarker Bacteroides (using culture-independent PCR-based methods) and for the faecal biomarker coprostanol (5β-cholestan-3-β-ol, which ranged in concentration from <0.05-0.77?mg?kg(?-?1). There was a significant statistical correlation between these two independent techniques for faecal contamination identification. Overall the microbial water quality and sedimentary biomarker surveys suggest sewage contamination in Bermuda was quite low compared with other published studies; nevertheless, several sewage contamination hotpots exist, and these could be attributed to discharge of raw sewage from house boats, from nearby sewage outfalls and leakage from septic tanks/cess pits.  相似文献   

17.
Molecular techniques are an alternative to culturing and counting methods in quantifying indoor fungal contamination. Pyrosequencing offers the possibility of identifying unexpected indoor fungi. In this study, 50 house dust samples were collected from homes in the Yakima Valley, WA. Each sample was analyzed by quantitative PCR (QPCR) for 36 common fungi and by fungal tag-encoded flexible (FLX) amplicon pyrosequencing (fTEFAP) for these and additional fungi. Only 24 of the samples yielded amplified results using fTEFAP but QPCR successfully amplified all 50 samples. Over 450 fungal species were detected by fTEFAP but most were rare. Twenty-two fungi were found by fTEFAP to occur with at least an average of ≥0.5% relative occurrence. Many of these fungi seem to be associated with plants, soil or human skin. Combining fTEFAP and QPCR can enhance studies of fungal contamination in homes.  相似文献   

18.
The resistance pattern and mechanisms of bacterial isolates obtained from clinical origin, soil, industrial effluent, orange juice products and drinking water were studied using commonly used antibiotics. The microbial load of the water samples, industrial effluent and orange juice products were 1.0 × 101–2.25 × 106, 2.15 × 105, and 3.5 × 104–2.15 × 105 cfu mL–1, respectively. The faecal coliform test revealed that only two out of twenty orange juice products had MPN of 2 and 20, the MPN of water ranged from 1–1800, while the effluent had MPN of 1800. The bacterial isolates that were isolated include E. coli, S. aureus, P. vulgaris, S. marcescens, S. pyogenes, B. cereus, B. subtilis, Micrococcus sp., Klebsiella sp., P. aeruginosa, and Enterobacter sp. Also, clinical and soil isolates of P. aeruginosa were used in the study. Among the eight antibiotics tested for resistance on five strains of each bacterium, seven different resistance patterns were observed among the bacterial isolates obtained from water, effluent and orange juice products. Among the clinical and soil isolates of P. aeruginosa, four multiple-drug resistance patterns were obtained. Thirty strains of E. coli and S. aureus were tested for -lactamase production and fourteen strains, seven each of E. coli and S. aureus that had high Minimum Inhibitory Concentration values (MIC) for both Amoxycillin and Cloxacillin were positive.  相似文献   

19.
In spite of the importance and popularity of swimming pools in summer, they have been identified as posing some public health risks to users due to either chemical or microbiological contamination. This study was carried out aiming at assessing the quality of water for some Alexandria's swimming pools in order to determine its compliance with the Egyptian standards no. 418/1995. Five swimming pools were selected randomly from different districts. Physical and chemical parameters, as well as biological examination of a total of 30 samples, were carried out using standard analytical methods. Water samples were collected from the studied swimming pools monthly over 6?months and pool water monitoring was carried out during afternoon of the weekends when the pools were most heavily used. The results indicated overall poor compliance with the standards. Compliance of the pool water to the microbial parameters, residual chlorine, pH, and turbidity were 56.7% (17 samples), 20% (6 samples), 46.7% (14 samples), and 46.7% (14 samples), respectively. Statistical analysis showed significant association between water contamination with microbial indicators and physical–chemical aspects such as residual chlorine, temperature, turbidity, and load of swimmers. Furthermore, Cryptosporidium oocysts and Giardia lamblia cysts has been found in 10% of samples. It was concluded that there is a need to improve disinfection and cleaning procedures, with consideration given to safety, and size of the pool in relation to bathing load. There is also a need to monitor swimming pool water quality continuously, and to increase bather hygienic practices and awareness of the risks as well as training of governmental inspectors.  相似文献   

20.
Efficient management of deteriorating water bodies can be achieved by determining the sources of faecal pollution. Resourceful techniques for discrimination of the sources of Escherichia coli in surface water have recently been developed, including the use of river water to facilitate faecal indicator surveillance, identification of sources of faecal contamination and employing relevant management practices to maintain water quality. This study was conducted to employ microbial source tracking (MST) techniques for the determination of the sources of faecal pollution based on a water quality investigation of the physico-chemical characteristics and coliform count point of the Tirumanimuttar River. To accomplish this, an MST library-based antibiotic resistance analysis, serotyping and the genomic tool rep-PCR techniques were applied, and the obtained results were analysed statistically. Among 135 and 70 E. coli isolates present in the library and water samples collected from the river and nearby well water sources, respectively, most showed intrinsic, high or moderate resistance to antibiotics. Isolates from human and pig faecal sources were 92% homologous with the samples from the river, whereas isolates from sewage and dairy cattle showed 89% and 80% homology, respectively. These findings indicated that the Tirumanimuttar River is subjected to stress from anthropogenic activities and runoff contaminated with agricultural and human faecal contamination. The sources of faecal pollution identified in this study may facilitate the monitoring and management of the Tirumanimuttar River.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号