首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
Indoor radon distribution of subway stations in a Korean major city   总被引:1,自引:0,他引:1  
The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 ± 14.7 Bq m−3, and the range of values was from 9.4 to 98.2 Bq m−3. The radon concentrations in groundwater (average 31.0 ± 0.8 Bq m−3) were not significantly high in most stations, but the concentration (177.9 ± 2.3 Bq L−1) of one station was over the level of 148 Bq L−1 in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y−1, and 0.02 mSv y−1, respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.  相似文献   

2.
Health hazard from natural radioactivity in Brazilian granites, covering the walls and floor in a typical dwelling room, was assessed by indirect methods to predict external gamma-ray dose rates and radon concentrations. The gamma-ray dose rate was estimated by a Monte Carlo simulation method and validated by in-situ measurements with a NaI spectrometer. Activity concentrations of 232Th, 226Ra, and 40K in an extensive selection of Brazilian commercial granite samples measured by using gamma-ray spectrometry were found to be 4.5-450 Bq kg−1, 4.9-160 Bq kg−1 and 190-2029 Bq kg−1, respectively. The maximum external gamma-ray dose rate from floor and walls covered with the Brazilian granites in the typical dwelling room (5.0 m × 4.0 m area, 2.8 m height) was found to be 120 nGy h−1, which is comparable with the average worldwide exposure to external terrestrial radiation of 80 nGy h−1 due to natural sources, proposed by United Nations Scientific Committee on the Effects of Atomic Radiation. Radon concentrations in the room were also estimated by a simple mass balance equation and exhalation rates calculated from the measured values of 226Ra concentrations and the material properties. The results showed that the radon concentration in the room ventilated adequately (0.5 h−1) will be lower than 100 Bq m−3, value recommended as a reference level by the World Health Organization.  相似文献   

3.
Least squares (LS), Theil’s (TS) and weighted total least squares (WTLS) regression analysis methods are used to develop empirical relationships between radium in the ground, radon in soil and radon in dwellings to assist in the post-closure assessment of indoor radon related to near-surface radioactive waste disposal at the Low Level Waste Repository in England. The data sets used are (i) estimated 226Ra in the <2 mm fraction of topsoils (eRa226) derived from equivalent uranium (eU) from airborne gamma spectrometry data, (ii) eRa226 derived from measurements of uranium in soil geochemical samples, (iii) soil gas radon and (iv) indoor radon data. For models comparing indoor radon and (i) eRa226 derived from airborne eU data and (ii) soil gas radon data, some of the geological groupings have significant slopes. For these groupings there is reasonable agreement in slope and intercept between the three regression analysis methods (LS, TS and WTLS). Relationships between radon in dwellings and radium in the ground or radon in soil differ depending on the characteristics of the underlying geological units, with more permeable units having steeper slopes and higher indoor radon concentrations for a given radium or soil gas radon concentration in the ground. The regression models comparing indoor radon with soil gas radon have intercepts close to 5 Bq m−3 whilst the intercepts for those comparing indoor radon with eRa226 from airborne eU vary from about 20 Bq m−3 for a moderately permeable geological unit to about 40 Bq m−3 for highly permeable limestone, implying unrealistically high contributions to indoor radon from sources other than the ground. An intercept value of 5 Bq m−3 is assumed as an appropriate mean value for the UK for sources of indoor radon other than radon from the ground, based on examination of UK data. Comparison with published data used to derive an average indoor radon: soil 226Ra ratio shows that whereas the published data are generally clustered with no obvious correlation, the data from this study have substantially different relationships depending largely on the permeability of the underlying geology. Models for the relatively impermeable geological units plot parallel to the average indoor radon: soil 226Ra model but with lower indoor radon: soil 226Ra ratios, whilst the models for the permeable geological units plot parallel to the average indoor radon: soil 226Ra model but with higher than average indoor radon: soil 226Ra ratios.  相似文献   

4.
The 7Be wet deposition has been intensively investigated in a semiarid region at San Luis Province, Argentina. From November 2006 to May 2008, the 7Be content in rainwater was determined in 58 individual rain events, randomly comprising more than 50% of all individual precipitations at the sampling period. 7Be activity concentration in rainwater ranged from 0.7 ± 0.3 Bq l−1 to 3.2 ± 0.7 Bq l−1, with a mean value of 1.7 Bq l−1 (sd = 0.53 Bq l−1). No relationship was found between 7Be content in rainwater and (a) rainfall amount, (b) precipitation intensity and (c) elapsed time between events. 7Be ground deposition was found to be well correlated with rainfall amount (R = 0.92). For the precipitation events considered, the 7Be depositional fluxes ranged from 1.1 to 120 Bq m−2, with a mean value of 32.7 Bq m−2 (sd = 29.9 Bq m−2). The annual depositional flux was estimated at 1140 ± 120 Bq m−2 y−1. Assuming the same monthly deposition pattern and that the 7Be content in soil decreases only through radioactive decay, the seasonal variation of 7Be areal activity density in soil was estimated. Results of this investigation may contribute to a valuable characterization of 7Be input in the explored semiarid ecosystem and its potential use as tracer of environmental processes.  相似文献   

5.
Natural background gamma radiation and radioactivity concentrations were investigated from 2003 to 2005 in Kinta District, Perak, Malaysia. Sample locations were distant from any ‘amang’ processing plants. The external gamma dose rates ranged from 39 to 1039 nGy h−1. The mean external gamma dose rate was 222 ± 191 nGy h−1. Small areas of relatively enhanced activity were located having external gamma dose rates of up to 1039 ± 104 nGy h−1. The activity concentrations of 238U, 232Th and 40K were analyzed by using a high-resolution co-axial HPGe detector system. The activity concentration ranges were 12–426 Bq kg−1 for 238U, 19–1377 Bq kg−1 for 232Th and <19–2204 Bq kg−1 for 40 K. Based on the radioactivity levels determined, the gamma-absorbed dose rates in air at 1 m above the ground were calculated. The calculated dose rates and measured dose rates had a good correlation coefficient, R of 0.94. To evaluate the radiological hazard of the natural radioactivity, the radium equivalent activity, the gamma-absorbed dose rate and the mean population weighted dose rate were calculated. An isodose map for the Kinta District was also produced.  相似文献   

6.
Phosphogypsum (PG) has been traditionally applied as Ca-amendment in saline marsh soils in SW Spain, where available PG has 710 ± 40 Bq kg−1 of 226Ra. This work assesses the potential radiological risk for farmers through 222Rn exhalation from PG-amended soils and by inhalation of PG-dust during its application. A three-year field experiment was conducted in a commercial farm involving two treatments: control and 25 t PG ha−1 with three replicates (each 0.5 ha plots). The 222Rn exhalation rate was positively correlated with potential evapotranspiration, which explained 67% of the variability. Statistically significant differences between the control and PG treatments were not found for 222Rn exhalation rates, and mean values were within the lowest quartile of the typical range for 222Rn exhalation from soils. Airborne dust samples were collected during the application of PG and sugar-beet sludge amendments. The highest PG-attributable 226Ra concentration in the dust samples was 3.3 × 102 μBq m−3, implying negligible dose increment for exposed workers.  相似文献   

7.
Radon and gamma dose rate measurements were performed in 512 schools in 8 of the 13 regions of Greece. The distribution of radon concentration was well described by a lognormal distribution. Most (86%) of the radon concentrations were between 60 and 250 Bq m−3 with a most probable value of 135 Bq m−3. The arithmetic and geometric means of the radon concentration are 149 Bq m−3 and 126 Bq m−3 respectively. The maximum measured radon gas concentration was 958 Bq m−3. As expected, no correlation between radon gas concentration and indoor gamma dose rate was observed. However, if only mean values for each region are considered, a linear correlation between radon gas concentration and gamma dose rate is apparent. Despite the fact that the results of radon concentration in schools cannot be applied directly for the estimation of radon concentration in homes, the results of the present survey indicate that it is desirable to perform an extended survey of indoor radon in homes for at least one region in Northern Greece.  相似文献   

8.
In China, as the economy is developing and the population is expanding, some underground buildings have been used as supermarkets, restaurants and entertainment places. Tunnels in mountains are one type of underground building, and the radon (222Rn) level in tunnels is an important issue. Radon levels in different type tunnels appear to differ, and relatively higher levels of 222Rn are associated with particular types of bedrock. The 222Rn levels in tunnels in five different geological characteristics were analyzed. Those built in granite had the highest 222Rn levels with a geometric mean (GM) of 280 Bq m−3, while those built in limestone (GM: 100 Bq m−3) and andesitic porphyry (GM: 96 Bq m−3) were lower. The sequence of 222Rn concentrations was: granite > tuff > quartz sandstone > limestone > andesitic porphyry, and the 222Rn in granite was statistically significantly higher than in limestone and andesitic porphyry. Tunnels built in granite, tuff, quartz sandstone, limestone tended to have higher 222Rn concentrations in summer than in winter, while the reverse tendency was true in andesitic porphyry tunnels. Only the difference in limestone was statistically significant.  相似文献   

9.
Using the closed-can technique, radon exhalation rate measurements have been carried out for shale and coal samples collected from various mines located in the Chakwal and Makarwal areas of Pakistan. For the two areas, the measured average values of the exhalation rates from shale are 1.45±0.13 and 0.67±0.25 Bq m−2 h−1 and for coal are 1.0±0.03 and 0.65±0.32 Bq m−2 h−1, respectively. These values are much lower than the measured exhalation rates from alum-shale-based Nordic concrete which has values in the 50–200 Bq m−2 h−1 range. The lower values of the measured exhalation rates from the shale and coal deposits in the Chakwal and Makarwal areas are indicative of their lower uranium contents and mine workers in these areas do not face any abnormal health hazard due to radon since the exhalation rates have been found to be on the low side.  相似文献   

10.
One of the essential parameters influencing of the dose conversion factor is the ratio of unattached short-lived radon progeny. This may differ from the value identified for indoor conditions when considering special workplaces such as mines. Inevitably, application of the dose conversion factors used in surface workplaces considerably reduces the reliability of dose estimation in the case of mines.This paper surveyed the concentration of radon and its short-lived radon progeny and identified the unattached fraction of short-lived radon progeny. As well equilibrium factor during the month of August was calculated simultaneously at two extraction faces in a manganese ore mine.During working hours the average radon concentrations were 220 Bq m−3 and 530 Bq m−3 at Faces 1 and 2; the average short-lived progeny concentration was 90 Bq m−3 and 190 Bq m−3, the average equilibrium factors were 0.46 and 0.36, and the average unattached fractions were 0.21 and 0.17, respectively. The calculated dose conversion factor was between 9 and 27 mSv WLM−1, but higher values could also be possible.  相似文献   

11.
Coal, like most materials found in nature, contains trace quantities of the naturally occurring primordial radionuclides, i.e. of 40K and of 238U, 232Th and their decay products. Therefore, the combustion of coal results in the released into the environment of some natural radioactivity (1.48 TBq y−1), the major part of which (99 %) escapes as very fine particles, while the rest in fly ash. The activity concentrations of natural radionuclides measured in coals originated from coal mines in Greece varied from 117 to 435 Bq kg−1 for 238U, from 44 to 255 Bq kg−1 for 226Ra, from 59 to 205 Bq kg−1 for 210Pb, from 9 to 41 Bq kg−1 for 228Ra (232Th) and from 59 to 227 Bq kg−1 for 40K. Fly ash escapes from the stacks of coal-fired power plants in a percentage of 3-1% of the total fly ash, in the better case. The natural radionuclide concentrations measured in fly ash produced and retained or escaped from coal-fired power plants in Greece varied from 263 to 950 Bq kg−1 for 238U, from 142 to 605 Bq kg−1 for 226Ra, from 133 to 428 Bq kg−1 for 210Pb, from 27 to 68 Bq kg−1 for 228Ra (232Th) and from 204 to 382 Bq kg−1 for 40K. About 5% of the total ash produced in the coal-fired power plants is used as substitute of cement in concrete for the construction of dwellings, and may affect indoor radiation doses from external irradiation and the inhalation of radon decay products (internal irradiation) is the most significant. The resulting normalized collective effective doses were 6 and 0.5 man-Sv (GW a)−1 for typical old and modern coal-fired power plants, respectively.  相似文献   

12.
Following the Chernobyl accident, 137Cs contamination levels of wild boar in some districts of Southern Germany are still exceeding thousands of Bq kg−1. While the long term 137Cs concentration in forest plants, mushrooms, and roe deer meat has decreased significantly, for wild boar it has remained constant during the last decade. Between 1998 and 2008, we analysed the muscle meat of 656 wild boars shot in the district (“Landkreis”) Ravensburg. The 137Cs activity concentration showed considerable variability from less than 5 up to 8266 Bq kg−1 and it followed a seasonal pattern, which is attributed to changes in dietary habits, fodder availability, meteorological conditions and specific behaviour of 137Cs in wild boar organism. Tag values for wild boars from the district Ravensburg varied from 0.008 to 0.062 m2 kg−1 during 2000–2008.  相似文献   

13.
This paper shows the results of a survey carried out at some refractory manufacturing plants. During the first part of the survey, the concentration of natural radioactivity in raw materials and end-products, coming from four plants, was assessed. Several raw materials and, as a consequence, some end-products as well have shown activity concentrations exceeding a few hundreds of Bq kg−1 of 238U and 232Th. In some important raw materials, such as bauxite and corundums, a remarkable radioactive disequilibrium was observed; this is probably due to the high temperature processes undergone by these materials. The second part of the survey focussed on the measurements of ambient equivalent dose rates, airborne dust concentrations and radon indoor. On the basis of results obtained, the effective dose for the standard worker was estimated. Two different types of refractory plants were investigated. Effective doses for both plants were lower than 1 mSv y−1.  相似文献   

14.
Galicia (NW Spain) is a radon-prone area in the Iberian Peninsula. Measurements were carried out at a rural dwelling, with an annual average of radon concentration over 4000 Bq m−3 and a maximum of 9000 Bq m−3, found during a radon screening campaign held in the Autonomous Community of Galicia. We performed a detailed study to identify the main contamination source and the behaviour of the radon concentration, in which a linear dependence with temperature was verified, once corrected for relative humidity. We used different passive methods (charcoal canisters and two types of etched track detectors) as well as a radon concentration monitor that provided continuous measurement. Subsequent to this characterization, and in order to reduce the high radon concentration, a remedial action was developed using different passive and forced ventilation methods. A modified subslab depressurization technique was found to be the most effective remedy, providing a radon concentration reduction of around 96%. This method also has the advantages of being inexpensive and reliable over time.  相似文献   

15.
The Syabru-Bensi hydrothermal zone, Langtang region (Nepal), is characterized by high radon-222 and CO2 discharge. Seasonal variations of gas fluxes were studied on a reference transect in a newly discovered gas discharge zone. Radon-222 and CO2 fluxes were measured with the accumulation chamber technique, coupled with the scintillation flask method for radon. In the reference transect, fluxes reach exceptional mean values, as high as 8700 ± 1500 g m−2 d−1 for CO2 and 3400 ± 100 × 10−3 Bq m−2 s−1 for radon. Gases fluxes were measured in September 2007 during the monsoon and during the dry winter season, in December 2007 to January 2008 and in December 2008 to January 2009. Contrary to expectations, radon and its carrier gas fluxes were similar during both seasons. The integrated flux along this transect was approximately the same for radon, with a small increase of 11 ± 4% during the wet season, whereas it was reduced by 38 ± 5% during the monsoon for CO2. In order to account for the persistence of the high gas emissions during monsoon, watering experiments have been performed at selected radon measurement points. After watering, radon flux decreased within 5 min by a factor of 2–7 depending on the point. Subsequently, it returned to its original value, firstly, by an initial partial recovery within 3–4 h, followed by a slow relaxation, lasting around 10 h and possibly superimposed by diurnal variations. Monsoon, in this part of the Himalayas, proceeds generally by brutal rainfall events separated by two- or three-day lapses. Thus, the recovery ability shown in the watering experiments accounts for the observed long-term persistence of gas discharge. This persistence is an important asset for long-term monitoring, for example to study possible temporal variations associated with stress accumulation and release.  相似文献   

16.
In the framework of a 222Rn screening campaign that was carried out in 58 public secondary schools in Galicia (NW Spain), the largest radon-prone area in the Iberian Peninsula, a positive correlation between indoor 222Rn concentration and outdoor gamma exposure rate was obtained. A new approach to the data acquisition in screening surveys was tested, improving the performances of this type of study and gathering useful data for future remedial actions. Using short-period detectors (charcoal canisters) firstly, in order to detect places showing 222Rn concentrations over 400 Bq m−3, the number of locations to be measured with long-period detectors (etched track detectors) is reduced. In this screening campaign, 34% of the schools surveyed presented at least one site exceeding the 400 Bq m−3 recommended action level established by the EU, and 15% had at least one site with 222Rn values over 800 Bq m−3. The maximum value recorded was 2084 ± 63 Bq m−3. These results are discussed and compared with data obtained in schools of several countries with similar geology. Seven schools were also studied for seasonal variations of 222Rn activity concentration. The results were not conclusive, and no significant correlation between season and 222Rn concentration was established. Finally, a continuous 222Rn concentration monitor was placed in the secondary school exhibiting a mean value of the 222Rn concentration very close to 400 Bq m−3. Maximum 222Rn concentration values were found to occur at times when the school was unoccupied.  相似文献   

17.
The vertical distribution of 137Cs activity in peat soil profiles and 137Cs activity concentration in plants of various species was studied in samples collected at two sites on a raised bog in central Sweden. One site (open bog) was in an area with no trees and only a few sparsely growing plant species, while the other (low pine) was less than 100 m from the open bog site and had slowly growing Scots pine, a field layer dominated by some ericaceous plants and ground well-covered by plants. The plant samples were collected in 2004–2007 and were compared with samples collected in 1989 from the same open bog and low pine sites. Ground deposition of 137Cs in 2005 was similar at both sites, 23?000 Bq m−2. In the open bog peat profile it seems to be an upward transport of caesium since a clear peak of 137Cs activity was found in the uppermost 1–4 cm of Sphagnum layers, whereas at the low pine site 137Cs was mainly found in deeper (10–12 cm) layers. The migration rate was 0.57 cm yr−1 at the open bog site and the migration centre of 137Cs was at a depth of 10.7, while the rate at the low pine site was 0.78 cm yr−1 and the migration centre was at 14.9 cm. Heather (Calluna vulgaris) was the plant species with the highest 137Cs activity concentrations at both sites, 43.5 k Bq−1 DM in 1989 decreasing to 20.4 in 2004–2007 on open bog and 22.3 k Bq kg−1 DM in 1989 decreasing to 11.2 k Bq−1 DM by the period 2004–2007 on the low pine site. 137Cs transfer factors in plants varied between 0.88 and 1.35 on the open bog and between 0.48 and 0.69 m2 kg−1 DM at the low pine site.  相似文献   

18.
Radioactive markers are useful in dating lead deposition patterns from industrialization in peat archive. Peat cores were collected in an ombrotrophic peat bog in the Great Hinggan Mountains in Northeast China in September 2008 and dated using 210Pb and 137Cs radiometric techniques. The mosses in both cores were examined systematically for dry bulk density, water and ash content. Lead also was measured using atomic emission spectroscopy with inductively coupled plasma (ICP-AES). Both patterned peat profiles were preserved well without evident anthropogenic disturbance. Unsupported 210Pb and 137Cs decreased with the depth in both of the two sample cores. The 210Pb chronologies were established using the constant rate of supply model (CRS) and are in good agreement with the 137Cs time marker. Recent atmospheric 210Pb flux in Great Hinggan Mountains peat bog was estimated to be 337 Bq m−2 y−1, which is consistent with published data for the region. Lead deposition rate in this region was also derived from these two peat cores and ranged from 24.6 to 55.8 mg m−2 y−1 with a range of Pb concentration of 14-262 μg g−1. The Pb deposition patterns were consistent with increasing industrialization over the last 135-170 y, with a peak of production and coal burning in the last 50 y in Northeast China. This work presents a first estimation of atmospheric Pb deposition rate in peatlands in China and suggests an increasing trend of environmental pollution due to anthropogenic contaminants in the atmosphere. More attention should be paid to current local pollution problems, and society should take actions to seek a balance between economic development and environmental protection.  相似文献   

19.
In this paper deposition rate coefficients for unattached and attached radon progeny were estimated according to a particle deposition model for turbulent indoor airflow described by Zhao and Wu [2006. Modeling particle deposition from fully developed turbulent flow in ventilation duct. Atmos. Environ. 40, 457–466]. The parameter which characterizes turbulent indoor airflow in this model is friction velocity, u*. Indoor ventilation changes indoor airflow and friction velocity and influences deposition rate coefficients. Correlation between deposition and ventilation rate coefficients in the room was determined. It was shown that deposition rate coefficient increases with ventilation rate coefficient and that these parameters of the Jacobi room model cannot be assumed to be independent. The values of deposition rate coefficients were presented as functions of friction velocity and ventilation rate coefficient. If ventilation rate coefficient varies from 0.1 up to 1 h−1, deposition rate coefficients for unattached and attached fractions were estimated to be in the range 3–110 h−1 and 0.015–0.35 h−1, respectively.  相似文献   

20.
To study the Pu concentration and isotope ratio distributions present in China, the 239+240Pu total activities and 240Pu/239Pu atom ratios in core soil samples from Hubei Province in central China were investigated using Accelerator Mass Spectrometry (AMS). The activities ranged from 0.019 to 0.502 mBq g−1 and the 239+240Pu inventories of 45 and ∼55 Bq m−2 agree well with that expected from global fallout. The 240Pu/239Pu atom ratios in the soil ranged from 0.172 to 0.220. The ratios are similar to typical global fallout values. Hence, any close-in fallout contribution from the Chinese nuclear weapons tests, mainly conducted in the 1970s, must have either been negligible or had a similar 240Pu/239Pu ratio to that of global fallout. The top 10 cm layer of the soil contributes ∼90% of the total inventory and the maximum concentrations appeared in the 2-4 cm or 4-6 cm layers. It is suggested that climatic conditions and organic content are the two main factors that affect the vertical migration of plutonium in soil.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号