首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
A pilot submerged membrane bioreactor coupled with biological nutrient removal was used to treat the primary effluent at a municipal wastewater treatment plant. Long-term experiments were conducted by varying hydraulic retention time from 6 to 8 hours and solids retention time from 20 to 50 days, respectively. The performance was assessed by monitoring key wastewater parameters, including chemical oxygen demand (COD), nitrogen, and phosphorus concentration in individual anoxic, anaerobic, aerobic, and membrane separation zones. Results showed that the tested system can consistently achieve COD, nitrogen, and phosphorus removal efficiencies at 80 to 98%, 70 to 93%, and 89 to 98%, respectively. Effluent COD remained low as a result of efficient solid retention, even though there was great variation in influent quality. However, total nitrogen increased proportionally with influent concentration. At a 50-day solids retention time, higher COD and nitrogen oxides specific utilization rates in the anoxic zone resulted in a high production of nitrogen oxides in the subsequent aerobic zone.  相似文献   

2.
垃圾压缩站污水是一种具有高COD、高NH3-N特点的有机污水.以厌氧/好氧组合工艺为基础,通过投加高效菌株对活性污泥系统进行生物强化.实验结果表明,与空白相比,厌氧出水COD去除率提高约30%,好氧出水NH3-N去除率提高约20%.最终出水COD《120 mg/L, NH3-N《25 mg/L,均达到《污水综合排放标准》(GB 8978-1996)二级排放标准.  相似文献   

3.
The design criteria for wastewater treatment plants (WWTP) and the sludge retention time, respectively, have a significant impact on micropollutant removal. The upgrade of an Austrian municipal WWTP to nitrogen removal (best available technology, BAT) resulted in increased elimination of most of the analyzed micropollutants. Substances, such as bisphenol-A, 17α-ethinylestradiol and the antibiotics erythromycin and roxithromycin were only removed after the upgrade of the WWTP. Nevertheless, the BAT was not sufficient to completely eliminate these compounds. Thus, a pilot scale ozonation plant was installed for additional treatment of the effluent. The application of 0.6 g O3 g DOC−1 increased the removal of most of the micropollutants, especially for compounds that were not degraded in the previous biological process, as for example carbamazepine and diclofenac. These results indicated that the ozonation of WWTP effluent is a promising technology to further decrease emissions of micropollutants from the treatment process.  相似文献   

4.
组合人工湿地处理工业园区污水厂尾水的中试研究   总被引:3,自引:0,他引:3  
杨林  李咏梅 《环境工程学报》2012,6(6):1846-1850
在巢湖流域水环境治理中,依托工业园区污水厂,进行了组合人工湿地处理工业园区污水厂尾水的中试研究。介绍了工艺流程和设计参数,运行结果表明,整个处理系统运行稳定,对COD、NH4+-N和TP的平均去除率分别为65.5%、75.5%和49.2%,其中一级潜流湿地对各污染物的去除贡献率最高。系统出水COD、氨氮、总磷基本达到了《地表水环境质量标准》(GB3838-2002)中的Ⅴ类水标准。此外还利用GC/MS初步对系统进出水进行了有机物组分分析,结果表明尾水中含有除草剂及农药中间体等难降解有机物,组合人工湿地对这些物质有一定去除效果。  相似文献   

5.
曝气生物滤池处理农村污水的中试研究   总被引:4,自引:3,他引:1  
采用研制的曝气生物滤池对农村污水进行处理,研究其性能特点和影响因素。结果表明:在气水比为5∶1,水力停留时间(HRT)为15 h,进水COD浓度在250 mg/L以下时,COD和氨氮的去除率分别在80%和90%以上,出水COD和氨氮值达到国家《城镇污水处理厂污染物排放标准》一级A标准;反应器在冬季水温12℃以上运行时出水COD和氨氮值比在夏季运行时有所上升,但去除率仍在80%和90%以上,可以达到排放标准。  相似文献   

6.
采用UASB中试(100 m3/d)对生活污水处理进行了研究。试验结果表明,采用此系统处理生活污水,出水水质良好。COD的去除率在52%~83%,出水的COD值<100 mg/L以下,SS的去除率在95%左右,UASB处理生活污水的最佳停留时间为6 h。产气率在0.1 m3/d。不管停留时间在10 h、5 h,出水的氨氮、乙酸值比进水的高;钙、镁、总氮、总磷、硫酸根和硝酸根离子出水值比进水值低。  相似文献   

7.
臭氧预氧化-BAF工艺深度处理垃圾渗滤液   总被引:4,自引:0,他引:4  
以广东省江门市垃圾填埋场垃圾渗滤液为研究对象,对经SBR生化处理和聚合硫酸铁混凝后的垃圾渗滤液,采用臭氧-BAF(曝气生物滤池)工艺进行深度处理。该工艺优点在于:臭氧高级氧化技术使大分子有机污染物降解成二氧化碳和水,或者小分子有机污染物,有利于后继BAF的生化处理,且臭氧处理过后废水的色度明显降低,是废水处理的有效方法之一。而后采用曝气生物滤池对垃圾渗滤液进行进一步处理,对COD进一步去除。结果表明,当臭氧的加入量为150 mg/L,BAF停留时间>4 h,出水COD低于85 mg/L,稳定达到国家GB 16889-1997《生活垃圾填埋污染控制标准》一级排放标准,臭氧氧化法处理每吨垃圾渗滤液的费用为4.8元。  相似文献   

8.

The concentrations and distribution of β-blockers, lipid regulators, and psychiatric and cancer drugs in the influent and effluent of the municipal wastewater treatment plant (WWTP) and the effluent of 16 hospitals that discharge into the wastewater treatment plant mentioned in this study at two sampling dates in summer and winter were examined. The pharmaceutical contribution of hospitals to municipal wastewater was determined. The removal of target pharmaceuticals was evaluated in a WWTP consisting of conventional biological treatment using activated sludge. Additionally, the potential environmental risk for the aquatic receiving environments (salt lake) was assessed. Beta-blockers and psychiatric drugs were detected in high concentrations in the wastewater samples. Atenolol (919 ng/L) from β-blockers and carbamazepine (7008 ng/L) from psychiatric pharmaceuticals were detected at the highest concentrations in hospital wastewater. The total pharmaceutical concentration determined at the WWTP influent and effluent was between 335 and 737 ng/L in summer and between 174 and 226 ng/L in winter. The concentrations detected in hospital effluents are higher than the concentrations detected in WWTP. The total pharmaceutical contributions from hospitals to the WWTP in summer and winter were determined to be 2% and 4%, respectively. Total pharmaceutical removal in the WWTP ranged from 23 to 54%. According to the risk ratios, atenolol could pose a high risk (risk quotient > 10) for fish in summer and winter. There are different reasons for the increase in pharmaceutical consumption in recent years. One of these reasons is the COVID-19 pandemic, which has been going on for 2 years. In particular, hospitals were operated at full capacity during the pandemic, and the occurrence and concentration of pharmaceuticals used for the therapy of COVID-19 patients has increased in hospital effluent. Pandemic conditions have increased the tendency of people to use psychiatric drugs. It is thought that beta-blocker consumption has increased due to cardiovascular diseases caused by COVID-19. Therefore, the environmental risk of pharmaceuticals for aquatic organisms in hospital effluent should be monitored and evaluated.

  相似文献   

9.
Fenton氧化-生化组合工艺处理染料中间体废水   总被引:9,自引:4,他引:9  
针对染料中间体废水具有COD高、BOD5/COD低和具有生物毒性的特性,采用Fenton氧化-水解酸化-好氧组合工艺进行染料中间体生产废水的处理试验,试验结果表明:废水经Fenton氧化及水解酸化工序后,废水的BOD5/COD值由0.03升高至0.48,经好氧生化工序处理后的出水COD和BOD5浓度分别达122.6 mg/L和54.6 mg/L,符合《污水综合排放标准》(GB8978-1996)二级标准,该组合工艺COD总去除率达94%.  相似文献   

10.
针对火炸药废水毒性大、硝基化合物浓度高、COD浓度高、可生化性差的特点,采用"三维电极(TDE)-铁屑内电解-厌氧-曝气生物滤池"工艺对火炸药废水进行中试研究。结果表明,在进水初始浓度COD为3 330~5 330 mg/L,硝基化合物为200~300 mg/L情况下,此工艺不但能够稳定去除COD,去除率达到96.9%,且能高效去除硝基化合物,去除率高达99.6%。出水水质完全符合《兵器工业水污染物排放标准(火炸药)》(GB14470-2002)要求,系统运行稳定。  相似文献   

11.
The water chemistry, toxicity, and biodegradation of wastewater from an industry producing mineral fibres for thermal insulation were studied. Values for COD, BOD5, suspended solids, and phenol exceeded permissible values for the wastewater discharged into a nearby river and acute toxicity was also detected. Consequently, the effluent should be treated in a municipal wastewater treatment plant so its ready biodegradability was investigated. We found that the wastewater was readily biodegradable, therefore we assume it can be treated in the wastewater treatment plant as the ratio of the wastewater flow rate and the minimal total inflow into the sewage treatment plant would be one to at least 30.  相似文献   

12.
对厌氧滤池反应器处理难降解印染废水进行中试研究。结果表明,厌氧滤池反应器水力停留时间(HRT)在8.1~14.6 h之间,进水COD浓度波动较大(500~1 000 mg/L)时,对COD平均去除率为20%。印染废水的BOD5/COD由0.23提高到0.35,废水可生化性明显改善。印染废水中硫酸根浓度略有下降,去除浓度为70 mg/L左右。厌氧滤池进出水颜色明显变化,由紫红色变为蓝黑色,紫外可见光谱分析表明废水中的有机物结构发生变化。  相似文献   

13.
偶氮二异庚腈的生产过程中产生大量的废水,其有机物和氨氮含量高,生化性差.为解决其处理达标问题,采用氨氮吹脱-上流式厌氧污泥床(UASB)-A/O- NaOCl强氧化-接触氧化的组合工艺对其进行了试验研究.结果表明,该工艺对COD、氨氮的去除率分别达到99%、98%以上.并在此试验研究的基础上,投资建设了一个污水处理站,采用氨氮吹脱-UASB-A/O-二级好氧-NaOCl强氧化-接触氧化-气浮池的组合工艺,经过一年多的运行,出水水质稳定,对COD、氨氮的去除率分别为99%、98%以上,出水水质达到《污水综合排放标准》(GB 8978-1996)的一级标准.  相似文献   

14.
The performance of an innovative membrane bioreactor (MBR) process using anoxic phosphorus uptake with nitrification and denitrification for the treatment of municipal wastewater with respect to operational performance and effluent quality is addressed in this paper. The system was operated at steady-state conditions with a synthetic acetate-based wastewater at a hydraulic retention time (HRT) of 12 hours and on degritted municipal wastewater at a total system HRT of 6 hours. The MBR system was able to achieve 99% biochemical oxygen demand (BOD), chemical oxygen demand (COD), and ammonia-nitrogen (NH4(+)-N); 98% total Kjeldahl nitrogen (TKN); and 97% phosphorus removal, producing effluent BOD, COD, NH4+-N, TKN, nitrate-nitrogen, nitrite-nitrogen, and phosphate-phosphorus of <3, 14, 0.2, 0.26, 5.8, 0.21, and <0.01 mg/L, respectively, at the 6-hour HRT. The comparison of the synthetic and municipal wastewater run is presented in this paper. Steady-state mass balance on municipal wastewater was performed to reveal some key features of the modified MBR system.  相似文献   

15.
以ABR反应器为基础,采用笼状填料,增加了缺氧与好氧段,设计了新型的ABR;以啤酒废水为处理对象,考察了新型反应器的启动过程,研究了新型反应器对废水COD的去除效果,分析了HRT、有机容积负荷对COD去除的影响,探讨了新型反应器处理过程中的pH变化及其原因,阐述了笼状填料截留和微生物的附着生长是出水SS较低的原因,出水氨氮浓度较低是增设的缺氧段和好氧段共同作用的结果。实验结果表明,其COD去除效率达96%,有机容积负荷约0.647~1.745 kg/(m3.d);当进水量为50 L/d时,其出水水质达到啤酒废水排放标准。  相似文献   

16.
Wastewater from the Afyon Alkaloids Factory (Afyon, Turkey) was subjected to low-pressure catalytic wet-air oxidation (CWAO) using Fenton's reagent, and the optimal reaction conditions were investigated. The CWAO using Fenton's reagent was applied to the factory effluent, diluted factory effluent, and aerobically pretreated wastewater. To find the optimum quantities of reagents, ferrous iron (Fe(+2))-to-substrate ratios of 1:10, 1:25, and 1:50 and hydrogen peroxide (H2O2)-to-Fe(+2) ratios of 1, 5, and 10 were investigated, and the treatment was carried out at different temperatures. High chemical oxygen demand (COD) removals were obtained at 50 degrees C, with the Fe(+2)-to-substrate ratio range between 1:10 and 1:25. The change in H2O2-to-Fe(+2) ratios did not cause any considerable effect. Also, the percentages of COD removals were nearly the same, so the ratio H2O2:Fe(+2):1 is recommended. Aerobic pretreatment seems to be effective. On the other hand, no enhancement was observed in the case of the diluted wastewater.  相似文献   

17.
The photo-Fenton reaction effect on the biodegradability improvement of 100 mg/L solution of 2,4-dichlorophenol (DCP) has been investigated. Biochemical oxygen demand (BOD) at 5 and 21 days, BODn/ chemical oxygen demand (COD) and BODn/total organic carbon (TOC) ratios, average oxidation state, and inhibition on activated sludge were monitored. For 50 mg/L hydrogen peroxide and 10 mg/L iron(II) initial concentrations and 40 minutes of reaction time in the photo-Fenton process, the biodegradability of the pretreated solution, measured as BOD5/COD ratio, was improved from 0 for the original DCP solution up to 0.18 (BOD21/COD = 0.24). At that point, all DCP was eliminated from the solution. To study the effect of the pretreatment step, the biological oxidation of pretreated solutions was tested in two semicontinuous stirred tank reactors, one operated with activated sludge and one with biomass acclimated to phenol. Results showed that more than 80% TOC removal could be obtained by codigestion of the pretreated solution with municipal wastewater. Total organic carbon removals of approximately 60% were also obtained when the sole carbon source for the aerobic reactors was the pretreated solution. The hydraulic retention times used in the bioreactors were of the same order of magnitude as those used at domestic wastewater treatment plants (i.e., between 12 and 24 hours). Kinetic studies based on pseudo-first-order kinetics have also been carried out. Constants were found to be in range 0.67 to 1.7 L x g total volatiles suspended solids(-1) x h(-1).  相似文献   

18.
对模拟磷霉素钠制药废水进行Fenton-水解酸化-接触氧化小试处理实验,考察了COD、有机磷的去除效果,并对处理前后的废水进行了GC-MS分析。结果显示,增加了Fenton预处理后磷霉素钠制药废水的COD和有机磷分别降低到100和2 mg/L,去除率均可达87%以上,出水COD满足化学制药行业污染物排放标准(GB 21904-2008);Fenton过程对制药厂废水中的复杂有机物去除效果明显,GC-MS结果表明,出水中基本检测不到复杂有机物。与制药厂采用的水解酸化-接触氧化处理效果相比,增加Fenton预处理可以提高废水的可生化性和系统的处理效率。  相似文献   

19.
十三碳二元酸发酵有机废水处理研究   总被引:3,自引:0,他引:3  
运用物化预处理和SBR生化工艺对十三碳二元酸发酵废水中高浓度有机物的降解特征及高2硫酸钠对微生物的有害抑制作用进行处理试验,研究结果表明。采用物化预处理与SBR生化法相结合的工艺可有效地处理该类废水。经驯化的耐盐微菌胶力和裂口虫为主,废水的CODcr去除率可达92%以上,BOD5去除率可达95%以上。  相似文献   

20.
水解-好氧生物法处理城市污水试验研究   总被引:1,自引:0,他引:1  
采用水解 好氧工艺的原理 ,设计了将污水与污泥处理合二为一的高效组合水解池 三相生物流化床流程 ,在广州经济技术开发区进行了处理量为 1 0 0L/h的城市污水处理试验。试验结果表明 :在平均进水CODCr为 4 92 3mg/L ,BOD5为 2 4 0 9mg/L ,SS为 5 5 2 3mg/L ,NH4 N为 1 8 8mg/L ,TP为 2 0mg/L条件下 ,平均出水CODCr为 4 7 3mg/L ,BOD5为 2 2 lmg/L ,SS为 1 3 9mg/L ,NH4 N为 5 2mg/L ,TP为 1 4mg/L ,并进行了该工艺中污泥循环的初步分析 ,为该工艺处理城市污水工业化提供了技术参考。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号