1.

Background, aim, and scope

Okadaic acid (OA) and analogues of dinophysistoxin (DTX) are key diarrheic shellfish poisoning (DSP) toxins, which possibly arouse DSP symptoms by consuming the contaminated shellfish. Because of the stable toxicity in high temperature and the long-term carcinogenicity, the outbreaks of DSP related to consumption of bivalve mollusks contaminated by DSP toxins pose a hazard to public health. Therefore, it is worth developing a fast and reliable analytical method for the detection of OA and analogues in shellfish. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ELISA) (icELISA) for detecting OA and DTX-1 in seafood was developed based on monoclonal antibody (McAb).

Methods

The OA was conjugated to human immunoglobulin G (IgG) and bovine serum albumin (BSA) by the active ester method as the immune antigen and the detective antigen. The spleen cells from BALB/c mice immunized with OA-IgG were fused with SP2/0 myeloma cells. A hybridoma cell line, which secreted McAb against OA, was selected by ??limiting dilution?? cloning. An icELISA was developed based on immobilized conjugate (OA-BSA) competing the McAb with the free OA in seafood sample.

Results

A hybridoma cell line, which secreted IgG1 subclass monoclonal antibody (McAb) against OA, was selected. The IC50 of the McAb for OA and dinophytoxin-1 (DTX-1) were 4.40 and 3.89 ng/mL, respectively. Based on the McAb, an indirect competitive ELISA for detection of OA and DTX-1 in seafood was developed. The regression equation was y?=?54.713x???25.879 with a coefficient correlation of R 2?=?0.9729. The linear range and the limit of detection were 0.4?C12.5 and 0.45 ng/mL, respectively. The average recovery of OA and DTX-1 spiked shellfish was 82.29% with the coefficient of variation of 7.67%.

Conclusion

The developed icELISA is a fast, sensitive, and convenient assay for detecting of total amount of OA and DTX-1 in seafood.  相似文献   

2.
A rapid and sensitive indirect competitive fluorescence-linked immunosorbent assay (cFLISA) method based on quantum dots as the fluorescence label coupled with secondary antibody (Ab2) for the detection of chlorpyrifos in drinking water has been developed. The cFLISA method allowed for chlorpyrifos determination in a liner working range of 15.2–205.5 ng mL?1. The 50 % inhibition value (IC50) and the limit of detection (LOD) of the cFLISA were 50.2 ng mL?1 and 8.4 ng mL?1, while the IC50 and the LOD of the conventhional enzyme linked immunosorbent assay (ELISA) were 95.3 ng- mL?1 and 16.2 ng mL?1, respectively. When the concentrations of chlorpyrifos were 200, 100 and 50 ng mL?1, the recoveries ranged from 90.8 % to 108.2 % with a coefficient of variation (CV) of 7.5 %–15.2 %. In water sample analysis, the results of cFLISA were similar to those obtained from a cELISA and a high performance liquid chromatography (HPLC) method, while the detection time by cFLISA was reduced 0.5 h compared with ELISA. It showed that cFLISA could be used as a new screening method for the detection of pesticide residue.  相似文献   

3.
A heterologous indirect enzyme-linked immunosorbent assay (ELISA) was developed, which was based on monoclonal antibody (Mab) to determine parathion residue in agricultural and environmental samples. Eight Mabs were produced by introducing the heterologous indirect ELISA into the screening procedure. It was shown that these Mabs had more broad-reactivity with twenty competitors than that of 5H7 (Mab produced by homologous screening). So it became much easier using these new Mabs to develop heterologous immunoassays. In addition, all the developed heterologous ELISAs could be used to determine parathion residue in semiquantitative or quantitative level, and their detection limitation (LOD) was around 2 ng/mL. Compared with the previous heterologous ELISA (hapten 11/5H7) with IC50 of 13.3 ng/mL, a better heterologous ELISA (hapten 11/1E1) was obtained with IC50 of 3.8 ng/mL, which improved the sensitivity 3.5 times. Finally, the latter was applied to parathion residue determination in spiked agricultural and environmental samples without extraction or cleanup. The average recoveries of parathion added to water, soil, cucumber, Chinese cabbage and carrot were between 80.4 % and 111.8 %. The LOD for water and soil samples was 5 ng/mL, and the LOD for cucumber, rice and corn samples was 10 ng/mL.  相似文献   

4.
A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC50 and IC10 of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries in six agricultural products were between 79.5% and 118.0%, with the intra-assay coefficient of variation being less than 8 %. The limit of detection for all tested products was 30 ng/g. To the best of our knowledge, this assay has the best specificity among all the published research on ELISAs for chlorpyrifos.  相似文献   

5.
Europium (Eu3+)-labeled antibody was used as a fluorescent label to develop a highly sensitive time-resolved fluoroimmunoassay (TRFIA) for determination of clothianidin residues in agricultural samples. Toward this goal, the Eu3+-labeled polyclonal antibody and goat anti-rabbit antibody were prepared for developing and evaluating direct competitive TRFIA (dc-TRFIA) and indirect competitive TRFIA (ic-TRFIA). Under optimal conditions, the half-maximal inhibition concentration (IC50) and the limit of detection (LOD, IC10) of clothianidin were 9.20 and 0.0909 μg/L for the dc-TRFIA and 2.07 and 0.0220 μg/L for the ic-TRFIA, respectively. The ic-TRFIA has no obvious cross-reactivity with the analogues of clothianidin except for dinotefuran. The average recoveries of clothianidin from spiked water, soil, cabbage, and rice samples were estimated to range from 74.1 to 115.9 %, with relative standard deviations of 3.3 to 11.7 %. The results of TRFIA for the blind samples were largely consistent with gas chromatography (R 2?=?0.9902). The optimized ic-TRFIA might become a sensitive and satisfactory analytical method for the quantitative monitoring of clothianidin residues in agricultural samples.  相似文献   

6.
Fumonisin B1 (FB1) is a secondary metabolite produced by Fusarium verticillioides or Fusarium proliferatum, which present in food and feed. It causes hazardous effects on human and animal health. A monoclonal antibody (mAb) against FB1 was produced and a simple, reliable and sensitive, competitive, indirect enzyme-linked immunosorbent assay (ci-ELISA) for detection of FB1 was developed and the experiment conditions were optimized. The coating concentration of FB1-ovalbumin (FB1-OVA) was 500 ng mL?1, the action concentrations of anti-FB1 mAb and goat anti-mouse IgG were 1.28 × 104 and 1:5000, respectively. The 50% inhibitory concentration (IC50) was 11 ng mL?1, with a detectable range of 1.25–250 ng mL?1, and a limit of determination (LOD) of 1.15 ng mL?1. The cross-reactivity (CR) of the antibody against fumonisin B2 (FB2) was 60.4, and <1% against deoxynivalenol (DON), aflatoxin B1 (AFB1), ochratoxin A (OTA) or zearalenone (ZEN). In spiked samples (250 ng g?1, 500 ng g?1, 1000 ng g?1), the mean recoveries ranged from 86.7 ± 5% to 102 ± 4%, and the coefficient of variation (CV) ranged from 3% to 10%. A survey of 96 corn samples from Bozhou, Fuyang, Bengbu, and Hefei, in Anhui province, China, was performed. Frequencies of FB1 contamination were 83.3%, 95.8%, 20.8% and 91.7%, and the mean concentrations of positive samples were 0.702 μg kg?1, 0.883 μg kg?1, 0.074 μg kg?1, and 0.276 μg kg?1, respectively. The results of this study suggest that the ci-ELISA developed in this study can be used to identify FB1 in corn, furthermore, further study is needed to investigate FB1 contamination in food and feed to prevent its harmful health effects.  相似文献   

7.
Gentamicin (Gent) is an aminoglycoside antibiotic being used in livestock sector. Gent residues could cause some genetic disorders by nonsense mutations. This study aimed to develop IgY-based ELISA for the detection of Gent in animal products. Gent was conjugated with Bovine serum albumin (BSA) by carbodiimide method for further immunization in the laying chickens. PEG-6000 extraction method was employed to extract IgY from the egg yolk. The titer of anti-Gent-IgY attained the peak of 1:256,000 after the 5th booster immunization. Checkerboard titration confirmed that, anti-Gent IgY in 1:2,000 dilution could give an Optical Density (OD) 1.0 at 2 µg mL?1 of Gent-OVA coating concentration. IgY-based indirect competitive ELISA (Ic-ELISA) showed that, the IC50 value of anti-Gent IgY was 2.69 ng mL?1 and regression curve equation was y = ?16.27x + 56.97 (R2 = 0.95, n = 3), confirming that, the detection limit (LOD, IC10 value) was 0.01 ng mL?1. Recoveries from fresh milk, pork and chicken samples were ranged from 69.82% to 94.32%, with relative standard deviation lower than 10.88%. Our results suggested that generated anti-Gent IgY antibodies can be used in routine screening analysis of Gent residues in food samples.  相似文献   

8.
Due to their increasing use, the residues of anti-neoplastic drugs have become emerging pollutants in aquatic environments. Most of them directly or indirectly interfere with the cell’s genome, which classifies them into a group of particularly dangerous compounds. The aim of the present study was to conduct a comparative in vitro toxicological characterisation of three commonly used cytostatics with different mechanisms of action (5-fluorouracil [5-FU], cisplatin [CDDP] and etoposide [ET]) towards zebrafish liver (ZFL) cell line, human hepatoma (HepG2) cells and human peripheral blood lymphocytes (HPBLs). Cytotoxicity was determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and acridine orange/ethidium bromide staining. All three drugs induced time- and dose-dependent decreases in cell viability. The sensitivity of ZFL and HepG2 cells towards the cytotoxicity of 5-FU was comparable (half maximal inhibitory concentration (IC50) 5.3 to 10.4 μg/mL). ZFL cells were more sensitive towards ET- (IC50 0.4 μg/mL) and HepG2 towards CDDP- (IC50 1.4 μg/mL) induced cytotoxicity. Genotoxicity was determined by comet assay and cytokinesis block micronucleus (CBMN) assay. ZFL cells were the most sensitive, and HPBLs were the least sensitive. In ZFL cells, induction of DNA strand breaks was a more sensitive genotoxicity endpoint than micronuclei (MNi) induction; the lowest effective concentration (LOEC) for DNA strand break induction was 0.001 μg/mL for ET, 0.01 μg/mL for 5-FU and 0.1 μg/mL for CDDP. In HepG2 cells, MNi induction was a more sensitive genotoxicity endpoint. The LOEC values were 0.01 μg/mL for ET, 0.1 μg/mL for 5-FU and 1 μg/mL for CDDP. The higher sensitivity of ZFL cells to cytostatic drugs raises the question of the impact of such compounds in aquatic ecosystem. Since little is known on the effect of such drugs on aquatic organisms, our results demonstrate that ZFL cells provide a relevant and sensitive tool to screen genotoxic potential of environmental pollutant in the frame of hazard assessment.  相似文献   

9.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) has been developed and optimized for atrazine determination in soil at different depths (0–10, 10–20, and 20–30 cm) before and after 48 h of application, corn shoot and cow milk samples collected from Dina farm, Egypt. This assay was based on a specific polyclonal antibodies (PAb) raised by immunizing New Zealand rabbits with an immunogen prepared by coupling 3-{4-(ethylamino)-6-(isopropylamino)-1,3,5-triazine-2-yl} thiopropanoic acid to bovine serum albumin (BSA) via N-hydroxysuccinimide (NHS) active ester method. The sensitivity (estimated as IC50value) was 17.5 μg mL?1 with a detection limit of 0.1 ng mL?1. The maximum atrazine concentration was found in soil especially in the deepest layer (325 and 890 μg kg?1 before and after application, respectively). Atrazine concentration in corn shoot was 333.28, μg kg?1 dry plant, while there was no detectable amount in milk. All samples screened by ELISA were validated by gas chromatography mass spectrometer procedure (GC/MS). Good correlation was achieved between the two methods (r = 0.997 for soil and 0.9814 for plant). This study demonstrates the utility and convenience of the simple, practical and cost–effective ELISA method in the laboratory for analysis of environmental samples. The method is ideal for the rapid screening of large numbers of samples in laboratories where access to GC/MS facilities, is limited or lacking.  相似文献   

10.
A new method for specific antibody production was developed using antibody (Ab)-pesticide complex as a unique immunogen. Parathion (PA) was the targeted pesticide, and rabbit polyclonal antibody (Pab) and mouse monoclonal antibody (Mab) were used as carrier proteins. The Ab-PA complexes were generated by conjugating the two antibodies with an excessive dosage of PA. It was shown that the sensitivity of homologous enzyme-linked immunosorbent assay (ELISA) using the new antibodies was similar to that using original antibodies. However, the new mouse Pab had not only similar positive recognizing spectrum as the original Mab, but also a significantly improved sensitivity in heterologous ELISA when some recognizable competitors were applied. IC50 value of ELISA based on a combination of the new mouse Pab and hapten 9 was 0.24 ng/mL, which was 445.54 times as that of the homologous ELISA. An Ab-pesticide complex may be a suitable alternative immunogen for producing highly specific antibody to improve the immunoassay sensitivity.  相似文献   

11.
Diethyl (carboxymethyl) phosphonate (DECP) was used as the hapten to develop an indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) for detecting organophosphorus pesticides (OPs). Conjugator of DECP with bovin serum albumin (BSA) was used as the immunogen for producing the polyclonal antibodies (PcAbs). Three antisera were obtained after the immune procedure. Characterization studies of the PcAbs indicated that the titer of antiserum-1 was highest in 3 antisera, and antiserum-1 had high affinity and specificity to the parathion, dichlorvos and pirimiphos. The IC-ELISA showed an IC50 of 0.428 μ g/mL with a detection limit of 0.0125 μ g/mL to parathion. The assay also indicated that the IC50 values of pirimiphos and dichlorvos were 0.331 μ g/mL and 1.25 μ g/mL respectively, and the detection limits of pirimiphos and dichlorvos were 0.0116 μ g/mL and 0.048 μ g/mL respectively. Recoveries of parathion, pirimiphos and dichlorvos spiked into water samples ranged from 90% to 160%. The results indicated that the ELISA could be a convenient and supplemental analytical tool for monitoring OPs residues in environmental water samples.  相似文献   

12.
A sensitive biotin–streptavidin‐amplified enzyme‐linked immunosorbent assay (BA‐ELISA) method was developed for detecting non‐steroidal anti‐inflammatory drug ketoprofen. Compared with traditional ELISA method, the sensitivity of proposed immunoassay was enhanced by the biotin–streptavidin system. Under the optimal condition, the median inhibitory concentration (IC50) was 0.25 ng mL?1, with minor cross‐reactivity to a number of structural analogs. This developed assay was successfully applied to detect the ketoprofen residues in different fish samples, and good recoveries (72.6–105.5%) were obtained. The results indicated that this immunoassay method could specifically detect trace ketoprofen residues and could be widely used for routine monitoring of food samples.  相似文献   

13.
The present study outlines applications of an enzyme-linked immunosorbent assay (ELISA) for the analysis of clenbuterol residues. Antisera were raised from rabbits immunized with diazotized clenbuterol-bovine serum albumin (BSA) conjugate. The assay was specific to clenbuterol with a half-maximum inhibition concentration (IC50) of 1.8 ng/mL and 2.5 ng/mL in blank swine urine and phosphate buffer solution, respectively. The assay had high cross-reactivity (86%) with mabuterol, but low with other adrenergic agonists and antagonists. The average recovery of clenbuterol, as measured with the ELISA, ranged from 90% to 112% in swine urine samples and from 86% to 95% in feeds, respectively. This new assay was compared with commercial ELISA test kits. An excellent correlation (r 2 = 0.98) between the two methods and satisfactory recoveries suggest that the new assay can be suitable for the determination of clenbuterol residues in real samples. The assay was used to analyze clenbuterol residues in 103 swine urine samples and 68 feed samples collected from northern China. Approximately 50% of the urine samples and 25% of the feed samples analyzed were found positive (concentration of clenbuterol ≥ 1 ppb). The results indicate that clenbuterol was misused in some of the areas surveyed.  相似文献   

14.
This study was undertaken to develop and validate direct competitive ELISA for the determination of chloramphenicol residues in bovine milk. Antisera and an enzyme-tracer for chloramphenicol were prepared and used to develop an ELISA with inhibition concentrations, IC20 and IC50, of 0.09 and 0.44 ng mL?1, respectively. Milk samples were spiked with standards equivalent to 0, 0.2, 0.3, 0.5, 1.0 &; 1.5 ng mL?1 and extracted in methanol. The mean recoveries were found to be 73–100% with coefficient of variance 7–11%. The decision limit (CCα) and detection capability (CCβ) were calculated as 0.10 and 0.12 ng mL?1, respectively. The results were found comparable with the commercial ELISA, having recoveries of 87 to 100%, CCα 0.09 ng mL?1 and CCβ 0.12 ng mL?1. As per Commission Decision 2002/657/EC, in-house ELISA was further validated by using LC-MS/MS. Mass spectral acquisition was done by using electrospray ionization in the negative ion mode applying single reaction monitoring of the diagnostic transition reaction for CAP (m/z 152, 194 and 257). The calibration curve showed good linearity in concentrations from 0.025 to 1.6 ng mL?1 with correction coefficient 0.9902. The mean recoveries were found to be 88 to 100%. The CCα was calculated as 0.057 ng mL?1 and CCβ 0.10 ng mL?1. Since CCα and CCβ are less than half of the MRPL (0.15 ng mL?1), the test was found suitable for screening and quantification of CAP residues in bovine milk samples. Results of surveillance studies indicated that out of 31 analyzed milk samples, 12.9% samples were found with CAP residues but only 3.2% samples were declared positive with maximum concentration 0.31 ng mL?1, slightly above the MRPL.  相似文献   

15.
A solid-phase microextraction (SPME) procedure has been developed to ex tract eight organophosphorus pesticides (OPs) in water and the method was compared with a conventional solid phase extraction (SPE) technique. The extracted OPs were analyzed by gas chromatography using thermionic specific detection. Both extraction methods presented linear calibration at least over the concentration range investigated (100 to 1000 ng.mL?1 for SPE and 1 to 100 ng.mL?1 for SPME). SPME method presented higher sensitivity than SPE. The quantitation limits were between 0.1 to 1.0 ng.mL?1 for SPME depending upon the analyte, and 100 ng.mL?1 for SPE. The precision, as measured by the standard deviations (RSD), were in the range 3.6 % to 5.8 % for SPME and 2.4 % to 9.2 % for SPE.

Along with the feature of being a solvent – free sampling technique, SPME offers additional benefits due to its high sensitivity, simplicity, and small size sample required (typically: SPE – 500 mL, SPME – 5 mL).  相似文献   

16.

Background, aim, and scope

According to the high incidence of cancer worldwide, the amount of cytostatic drugs administered to patients has increased. These compounds are excreted to wastewaters, and therefore become potential water contaminants. At this stage, very little is known on the presence and elimination of cytostatic compounds in wastewater treatment plants (WWTP). The aim of this study was to develop a liquid chromatography?Chigh-resolution mass spectrometry (LC?COrbitrap?CMS) method for the determination of cyclophosphamide and epirubicin in wastewaters. These compounds represent two outmost used cytostatic agents.

Materials and methods

Extraction and analytical conditions were optimized for cyclophosphamide and epirubicin in wastewater. Both solid-phase extraction using Oasis 200?mg hydrophilic?Clipophilic balanced (HLB) cartridges and direct injection analysis were evaluated. Mass spectral characterization and fragmentation conditions were optimized at 50,000 resolving power (full width at half maximum, m/z 200) to obtain maximum sensitivity and identification performance. Quality parameters (recoveries, limits of detection, and repetitivity) of the methods developed were determined, and best performance was obtained with direct water analysis of the centrifuged wastewater. Finally, this method was applied to determine the presence of cyclophosphamide and epirubicin in wastewaters from a hospital effluent, an urban effluent, and influents and effluents from three WWTP.

Results and discussion

Cyclophosphamide and epirubicin were recovered after 50?mL preconcentration on solid-phase extraction 200?mg Oasis HLB cartridges (87% and 37%, respectively), and no breakthrough was observed by extracting 500?mL of water. Limits of detection were of 0.35 and 2.77?ng/L for cyclophosphamide and epirubicin, respectively. On the other hand, direct injection of water spiked at 1???g/L provided recoveries of 107% for cyclophosphamide and 44% for epirubicin and limits of detection from 3.1 to 85?ng?L?1, respectively. The analysis of wastewaters using direct injection analysis revealed the presence of cyclophosphamide and epirubicin in WWTP influents and hospital and urban effluents at levels ranging from 5.73 to 24.8???g?L?1.

Conclusions

The results obtained in this study demonstrate the capability of LC?COrbitrap?CMS for accurate trace analysis of these very polar contaminants. This method permitted to identify cyclophosphamide and epirubicin in wastewaters and influents of WWTP, but no traces were detected in WWTP effluents. The methodology herein developed is sensitive and robust and applicable for screening of a large number of samples since no preconcentration is needed.  相似文献   

17.
A multiplex surface plasmon resonance (SPR) biosensor method for the detection of paralytic shellfish poisoning (PSP) toxins, okadaic acid (and analogues) and domoic acid was developed. This method was compared to enzyme-linked immunosorbent assay (ELISA) methods. Seawater samples (n?=?256) from around Europe were collected by the consortia of an EU project MIcroarrays for the Detection of Toxic Algae (MIDTAL) and evaluated using each method. A simple sample preparation procedure was developed which involved lysing and releasing the toxins from the algal cells with glass beads followed by centrifugation and filtering the extract before testing for marine biotoxins by both multi-SPR and ELISA. Method detection limits based on IC20 values for PSP, okadaic acid and domoic acid toxins were 0.82, 0.36 and 1.66 ng/ml, respectively, for the prototype multiplex SPR biosensor. Evaluation by SPR for seawater samples has shown that 47, 59 and 61 % of total seawater samples tested positive (result greater than the IC20) for PSP, okadaic acid (and analogues) and domoic acid toxins, respectively. Toxic samples were received mainly from Spain and Ireland. This work has demonstrated the potential of multiplex analysis for marine biotoxins in algal and seawater samples with results available for 24 samples within a 7 h period for three groups of key marine biotoxins. Multiplex immunological methods could therefore be used as early warning monitoring tools for a variety of marine biotoxins in seawater samples.  相似文献   

18.
Abstract

In the present work, dispersive micro-solid phase extraction (D-μ-SPE) method using magnetic graphene oxide tert-butylamine (GO/Fe3O4/TBA) nanocomposite, as an efficient sorbent, was applied for determining 2,4-dichlorophenoxyacetic acid (2,4-D) in water and food samples. Detection was carried out using high-performance liquid chromatography (HPLC) instrument. Influential parameters of D-μ-SPE such as sorbent and its amount, elution solvent and its volume, adsorption and desorption times and pH of sample solution were investigated and optimized. Under the optimized conditions, limit of detection and quantitation values were 0.007 and 0.02?μg/mL, respectively. Recovery data for several real samples were obtained within the range of 88.0–94.0% with a relative standard deviation (RSD) less than 7.5%. The proposed method was successfully applied to quantitative determination of 2,4-D in several vegetables and water samples.  相似文献   

19.
Dichlorodiphenyltrichloroethane (DDT) is one of the persistent organic pollutants (POPs) widely found in the environment and in the general population. In this study, a direct competitive enzyme immunoassay (EIA) has been developed for the quantitative analysis of DDT. To generate a specific polyclonal antibody for EIA, p, p′-DDT was conjugated to porcine thyroglobulin for rabbit immunization. At optimized EIA conditions, the standard curves ranged from 0.137 to 100 ng/mL with the quantification limit of 0.41 ng/mL. The coefficients of variation (CV%) were 5.42–10.53% for intra-assay and 6.04–7.26% for inter-assay. Cross-reactivities with DDT metabolites (DDTs, including o, p′-DDT, p, p′-DDD, o, p′-DDD, p, p′-DDE, o, p′-DDE, p, p′-dichlorobenzophenone (DCBP), o, p′-DCBP) were investigated. The polyclonal antibody showed relatively low and/or no cross-reactivity with these compounds, and the assay was seen to be highly selective for p, p′-DDT. Moreover, the DDTs could be ranked by their reactivity: DDT > DDD > DDE > DCBP. In addition, the characterization of the polyclonal antibody indicated that the antiserum possesses a high specificity for p, p′-isomers. The results indicated that the developed EIA using this antibody could be a convenient and supplemental analytical tool for monitoring DDT.  相似文献   

20.
Luo W  Zhou Q  Jiang G 《Chemosphere》2011,84(5):681-688
Due to the wide occurrence of endocrine disrupting chemicals in the environment, it is much of importance to develop high throughput screening method for the analysis of this kind of pollutants. Using anion-exchange membrane chromatography, vitellogenin (VTG) from the plasma of 17β-estradiol (E2) treated Chinese rare minnow was rapidly purified within 15 min. Both polyclonal antibody (PcAb) and monoclonal antibody (McAb) against rare minnow VTG (R-VTG) were prepared in rabbit and Balb/c mice, respectively. The competitive enzyme-linked immunosorbent assays (ELISA) based on either PcAb or McAb were developed to identify and quantify R-VTG in the plasma, and these two methods showed similar characteristics. The detection limits of both assays were lower than 3 ng mL−1 with the working ranges covering three magnitudes. The recovery efficiencies of PcAb and McAb based ELISA were 104.2% and 102.6%, respectively; and the intra-assay and inter-assay of these two assays were 6.2% and 9.2%, 8.6% and 12.8%, respectively. These results indicated that the described competitive ELISA methods were sensitive and valuable tools for quantifying vitellogenin in rare minnow plasma. These methods were then applied to measure R-VTG concentrations in plasma of male fish exposed to a series of E2 concentrations. When E2 levels were less than 10 ng L−1, R-VTG levels in plasma were comparable to that in solvent control, while R-VTG levels significantly increased 15-folds and 350-folds, respectively when E2 exposure concentrations were controlled at 10 and 50 ng L−1. The high sensitivity of Chinese rare minnow to E2 was demonstrated, making it a valuable model species to study environmental estrogens.  相似文献   