Abstract

To evaluate methods of reducing exposure of school children in southwest Mexico City to ambient ozone, outdoor ozone levels were compared to indoor levels under three distinct classroom conditions: windows/doors open, air cleaner off; windows/doors closed, air cleaner off; windows/ doors closed, air cleaner on. Repeated two-minute average measurements of ozone were made within five minutes of each other inside and outside of six different school classrooms while children were in the room. Outdoor ozone two-minute average levels varied between 64 and 361 ppb; mean outdoor levels were above 160 ppb for each of the three conditions. Adjusting for outdoor relative humidity, for a mean outdoor ozone concentration of 170 ppb, the mean predicted indoor ozone concentrations were 125.3 (±5.7) ppb with windows/doors open; 35.4 (±4.6) ppb with windows/ doors closed, air cleaner off; and 28.9 (±4.3) ppb with windows/ doors closed, air cleaner on. The mean predicted ratios of indoor to outdoor ozone concentrations were 0.71 (±0.03) with windows/doors open; 0.18 (±0.02) ppb with windows/doors closed, air cleaner off; and 0.15 (±0.02) ppb with windows/doors closed, air cleaner on. As outdoor ozone concentrations increased, indoor ozone concentrations increased more rapidly with windows and doors open than with windows and doors closed. Ozone exposure in Mexican schools may be significantly reduced, and can usually be kept below the World Health Organization (WHO) guideline of 80 ppb, by closing windows and doors even when ambient ozone levels reach 30Q ppb or more.  相似文献   

2.
Abstract

Ozone and several polar volatile organic compounds (VOCs) including organic acids and carbonyls (aldehydes and ketones) were measured over an approximately 24 hour period in four residences during the winter of 1993 and in nine residences during the summer of 1993. All residences were in the greater Boston, Massachusetts area. The relation of the polar VOCs to the ozone concentration was examined. Indoor carbonyl concentrations were similar between the summer and winter, with the total mean winter concentration being 31.7 ppb and the total mean summer concentration being 36.6 ppb. However, the average air exchange rate was 0.9 hr?1 during the winter and 2.6 hr?1 during the summer. Therefore, the estimated carbonyl emission rates were significantly higher during the summer. Indoor organic acid concentrations were about twice as high during the summer as during the winter. For formic acid, the indoor winter mean was 9.8 ppb, and the summer indoor mean was 17.8 ppb. For acetic acid, the indoor winter mean was 15.5 ppb, and the summer indoor mean was 28.7 ppb. The concentrations of the polar VOCs were found to be significantly correlated with one another. Also, the emission rates of the polar VOCs were found to be correlated with both the environmental variables such as temperature and relative humidity and the ozone removal rate; however, it was difficult to apportion the relative effects of the environmental variables and the ozone removal.  相似文献   

3.
Among eight commercial Greek varieties of tobacco (Nicotiana tabacum L.) tested for their ozone-sensitivity levels, the Zichnomirodata (KK6/5) variety was found to be the most sensitive, although less sensitive than the well-known super-sensitive Bel-W3. Besides qualitative differences in the appearance of macroscopic symptoms these two varieties can be used simultaneously as a reliable pair of ozone bioindicators. The occurrence of ozone in the Greek countryside was surveyed by biomonitoring in 14 rural regions over the country and by a simultaneous biomonitoring and instrumental recording of ozone concentrations at a single remote side (Pournaria, Arcadia). Phytotoxic symptoms were observed mainly on the leaves of Bel-W3 and occasionally on those of Zichnomirodata varieties, suggesting that ozone levels were high enough to affect at least sensitive species. The instrumental monitoring (during a total period of 912 h) revealed maximum hourly O3 concentration 62 ppb, while the thresholds of 30, 40 and 50 ppb were exceeded for 40%, 20% and 6% of the recording period, respectively. The accumulated exposure over 40 ppb (AOT40) for the daylight hours over the 38 monitored days was 680 ppb h.  相似文献   

4.
Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography. Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina. Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 +/- 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 +/- 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 +/- 6.3 ppb, n = 22).  相似文献   

5.
Over the past few years, concern has increased in Canada over the health and environmental impacts of elevated concentrations of ground-level ozone. During the summer the most populated regions of Canada frequently record ozone concentrations that exceed the one-hour average maximum acceptable air quality objective of 32 parts per billion (ppb). In 1988 the Canadian Council of Ministers of the Environment agreed to develop a federal/provincial management plan to control nitrogen oxide and volatile organic compound emissions to reduce ozone concentrations in all affected regions of the country. In addition to the proposed interim control measures, the plan recommended that studies be undertaken to acquire the information necessary to develop sound control strategies. This report represents one of those studies and provides a summary of ground-level ozone measurements for eastern Canada for the 1980 to 1991 period with an emphasis on seasonal variations, trends, and occurrences of high concentrations.

Southwestern Ontario experiences the highest maximum hourly ozone concentrations and the greatest frequency of hours greater than the 82 ppb acceptable objective. Urban sites have the highest frequencies of ozone concentration measurements in the < 10 ppb range, while rural and remote sites show peaks in frequency distribution in the 20 to 30 ppb range. Trend analysis of summertime (May to September) average daily maximum ozone concentration showed no consistent pattern for eastern Canadian sites during 1980 to 1991. Sites in Montreal showed statistically insignificant downward trends while sites in Toronto showed small but statistically significant upward trends. These ozone-increasing trends are associated with reductions in nitric oxide concentrations. At all sites there was large year-to-year variability in peak ozone levels and in the frequency of hours with ozone concentrations above the maximum acceptable objective.  相似文献   

6.
Ozone concentrations at a rural-remote site in a forested region of north-central West Virginia were monitored during 1988 and 1989, a drought and wet year, respectively. During 1988, the absolute maximum average concentration for a single hour was 156 ppb, while it was only 107 ppb in 1989. Overall, the frequency of high concentrations was greater during 1988; the 120 ppb National Ambient Air Quality Standard was exceeded 17 times. The 7-h period encompassing the highest growing season concentrations for this site over the 2-yr period is 1100- 1759 h EST, rather than the period 0900-1559 h originally used by the National Crop Loss Assessment Network. The 7-h growing season means (0900-1559 h) of 52.6 ppb and 47.1 ppb for 1988 and 1989, respectively, compare well to those reported for the Piedmont/Mountain/Ridge-Valley area, but are higher than those for other surrounding areas. The diurnal ozone patterns, as well as the distribution of concentration ranges and timing of seasonal maxima, suggest that long-range transport of ozone and its precursors probably is an important factor at this site, given its remote and rural character.  相似文献   

7.
Nitrogen dioxide is a ubiquitous pollutant in urban areas. Indoor NO2 concentrations are influenced by penetration of outdoor concentrations and by indoor sources. The objectives of this study were to evaluate personal exposure to NO2, taking into account human time-activity patterns in four Mexican cities. Passive filter badges were used for indoor, outdoor, and personal NO2 measurements over 48 hr and indoor workplace measurements over 16 hr. Volunteers completed a questionnaire on exposure factors and a time-activity diary during the sample period. An unpaired t test, an analysis of variance (ANOVA), and a linear regression were performed to compare differences among cities and mean personal NO2 concentrations involving housing characteristics, as well as to determine which variables predicted the personal NO2 concentration. Sampling periods were in April, May, and June 1996 in Mexico City, Guadalajara, Cuernavaca, and Monterrey. All 122 volunteers in the study were working adults, with a mean age of 34 (SD +/- 7.38); 64% were female, and the majority worked in public offices and universities. The highest NO2 concentrations were found in Mexico City (36 ppb for outdoor, 57 ppb for indoor, and 39 ppb for personal concentration) and the lowest in Monterrey (19 ppb for outdoor, 24 ppb for indoor, and 24 ppb for personal concentration). Significant differences in NO2 concentrations were found among the cities in different microenvironments. During the sampling period, volunteers spent 85% of their time indoors. The highest personal NO2 concentration was found when volunteers kept their windows closed (p = 0.03). In the regression model adjusted by city and gender, the best predictors of personal NO2 concentration were outdoor levels and time spent outdoors (R2 = 0.68). These findings suggest that outdoor NO2 concentrations were an important influence on the personal exposure to NO2, due to the specific characteristics and personal behavior of the people in these Mexican cities.  相似文献   

8.
A field study was carried out to investigate the internal and external carbon monoxide (CO) concentration levels of a public school building in Athens, Greece. Simultaneous measurements of indoor and outdoor CO concentrations were conducted using a non-dispersive infrared analyzer. Measurements of mean hourly CO concentrations inside and outside the sampling room were conducted on a 24-h basis for 13 consecutive days during May and June 1999 and for 14 consecutive days during December 1999. The aim of the study was to investigate the attenuation pattern of external pollution levels within the building. The diurnal concentration variations reported for different days during the week show that indoor CO concentrations are in general lower than the respective outdoor levels, and that the morning peaks of indoor concentrations show a delay of 1 h or less compared to the morning peaks of outdoor concentrations. The measured indoor to outdoor concentration ratios show a seasonal variation. An indoor air quality model for the prediction of indoor concentration levels developed by Hayes (J. Air Pollut. Control Assoc. 39 (11) (1989) 1453; J. Air Waste Manage. Assoc. 41 (2) (1991) 161) is coded as a computer program and evaluated using the experimental data. The model results are in good agreement with the indoor concentration measurements, although in some cases the model cannot respond adequately to sharp outdoor concentration changes. The ratio between measured and predicted daily maximum indoor concentration ranges between 0.88 and 1.23. The regression curve between predicted by the model and measured hourly indoor concentrations, for a continuous period of 96 h, has a slope of 0.64 and a coefficient of determination (R2) of 0.69.  相似文献   

9.
The ozone that initially presents in the previous day's afternoon mixing layer can remain in the nighttime atmosphere and then be carried over to the next morning. Finally, this ozone can be brought to the ground by downward mixing as mixing depth increases during the daytime, thereby increasing surface ozone concentrations. Variation of ozone concentration during each of these periods is investigated in this work. First, ozone concentrations existing in the daily early morning atmosphere at the altitude range of the daily maximum mixing depth (residual ozone concentrations) were measured using tethered ozonesondes on 52 experimental days during 2004-2005 in southern Taiwan. Daily downward-mixing ozone concentrations were calculated by a box model coupling the measured daily residual ozone concentrations and daily mixing depth variations. The ozone concentrations upwind in the previous day's afternoon mixing layer were estimated by the combination of back air trajectory analysis and known previous day's surface ozone distributions. Additionally, the relationship between daily downward-mixing ozone concentration and daily photochemically produced ozone concentration was examined. The latter was calculated by removing the former from daily surface maximum ozone concentration. The measured daily residual ozone concentrations distributed at 12-74 parts per billion (ppb) with an average of 42 +/- 17 ppb are well correlated with the previous upwind ozone concentration (R2 = 0.54-0.65). Approximately 60% of the previous upwind ozone was estimated to be carried over to the next morning and became the observed residual ozone. The daily downward-mixing ozone contributes 48 +/- 18% of the daily surface maximum ozone concentration, indicating that the downward-mixing ozone is as important as daily photochemically produced ozone to daily surface maximum ozone accumulation. The daily downward-mixing ozone is poorly correlated with the daily photochemically produced ozone and contributes significantly to the daily variation of surface maximum ozone concentrations (R2 = 0.19). However, the contribution of downward-mixing ozone to daily ozone variation is not included in most existing statistical models developed for predicting daily ozone variation. Finally, daily surface maximum ozone concentration is positively correlated with daily afternoon mixing depth, attributable to the downward-mixing ozone.  相似文献   

10.
An enhanced ozone forecasting model using nonlinear regression and an air mass trajectory parameter has been developed and field tested. The model performed significantly better in predicting daily maximum 1-h ozone concentrations during a five-year model calibration period (1993–1997) than did a previously reported regression model. This was particularly true on the 28 “high ozone” days ([O3]>120 ppb) during the period, for which the mean absolute error (MAE) improved from 21.7 to 12.1 ppb. On the 77 days meteorologically conducive to high ozone, the MAE improved from 12.2 to 9.1 ppb, and for all 580 calibration days the MAE improved from 9.5 to 8.35 ppb. The model was field-tested during the 1998 ozone season, and performed about as expected. Using actual meteorological data as input for the ozone predictions, the MAE for the season was 11.0 ppb. For the daily ozone forecasts, which used meteorological forecast data as input, the MAE was 13.4 ppb. The high ozone days were all anticipated by the ozone forecasters when the model was used for next day forecasts.  相似文献   

11.
Abstract

Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography.

Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina.

Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 ± 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 ± 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 ± 6.3 ppb, n = 22).  相似文献   

12.
ABSTRACT

The concentrations of contaminants in the supply air of mechanically ventilated buildings may be altered by pollutant emissions from and interactions with duct materials. We measured the emission rate of volatile organic compounds (VOCs) and aldehydes from materials typically found in ventilation ducts. The emission rate of VOCs per exposed surface area of materials was found to be low for some duct liners, but high for duct sealing caulk and a neo-prene gasket. For a typical duct, the contribution to VOC concentrations is predicted to be only a few percent of common indoor levels. We exposed selected materials to ~100-ppb ozone and measured VOC emissions. Exposure to ozone increased the emission rates of aldehydes from a duct liner, duct sealing caulk, and neoprene gasket. The emission of aldehydes from these materials could increase indoor air concentrations by amounts that are as much as 20% of odor thresholds. We also measured the rate of ozone uptake on duct liners and galvanized sheet metal to predict how much ozone might be removed by a typical duct in ventilation systems. For exposure to a constant ozone mol fraction of 37 ppb, a lined duct would initially remove ~9% of the ozone, but over a period of 10 days the ozone removal efficiency would diminish to less than 4%. In an unlined duct, in which only galvanized sheet metal is exposed to the air-stream, the removal efficiency would be much lower, ~0.02%. Therefore, ducts in ventilation systems are unlikely to be a major sink for ozone.  相似文献   

13.
Residential concentrations of formaldehyde have been associated with poor respiratory health in children, where formaldehyde has been measured using stationary monitors inside homes. Although children spend most of their time indoors at home, there are few studies of children’s personal exposure to formaldehyde. The aim of this study was to investigate the relationship between personal exposure formaldehyde concentrations, microenvironmental concentrations and time weighted exposure estimates in children.Forty-one primary school children (aged between 9 and 12 years) wore a personal passive sampler over two 24 h periods in two seasons and completed 24 h daily activity diaries and a questionnaire about lifestyle and behaviour. Samplers were co located indoors at home, outdoors at centralised locations and indoors at school for the corresponding period.Personal exposure formaldehyde concentrations in this group of children were generally low with a geometric mean concentration of 9.1 ppb (range <detection limit to 27.3 ppb). There were strong correlations between personal exposure concentrations and both domestic indoor (rs = .779, p < 0.001) and time weighted estimated (rs = .802, p < 0.001) concentrations. The time weighted model did not improve the estimate of personal exposure compared with stationary indoor concentrations. Indoor air concentration measured with a single stationary monitor was a suitable surrogate for personal exposure.  相似文献   

14.
Personal 48-hr exposures to formaldehyde and acetaldehyde of 15 randomly selected participants were measured during the summer/autumn of 1997 using Sep-Pak DNPH-Silica cartridges as a part of the EXPOLIS study in Helsinki, Finland. In addition to personal exposures, simultaneous measurements of microenvironmental concentrations were conducted at each participant's residence (indoor and outdoor) and workplace. Mean personal exposure levels were 21.4 ppb for formaldehyde and 7.9 ppb for acetaldehyde. Personal exposures were systematically lower than indoor residential concentrations for both compounds, and ambient air concentrations were lower than both indoor residential concentrations and personal exposure levels. Mean workplace concentrations of both compounds were lower than mean indoor residential concentrations. Correlation between personal exposures and indoor residential concentrations was statistically significant for both compounds. This indicated that indoor residential concentrations of formaldehyde and acetaldehyde are a better estimate of personal exposures than are concentrations in ambient air. In addition, a time-weighted exposure model did not improve the estimation of personal exposures above that obtained using indoor residential concentrations as a surrogate for personal exposures. Correlation between formaldehyde and acetaldehyde was statistically significant in outdoor microenvironments, suggesting that both compounds have similar sources and sinks in ambient urban air.  相似文献   

15.
Tracer gas was released upwind of a two-compartment complex shaped building under unstable atmospheric conditions. The mean wind direction was normal to or at 45° to the long face of the building. The general patterns of concentration distribution on the building external walls and inside the building were analysed and the influence of natural and mechanical ventilation on indoor concentration distributions was discussed. Mean concentration levels, as well as the concentration fluctuation intensity, were higher on the windward walls of the building, although concentration levels varied along each wall. Concentration fluctuations measured inside the building were lower than those measured outside. Inside the two compartments of the building, the time series of concentrations had a similar general behaviour; however, gas concentrations took approximately 1.5 times longer to reach the mean maximum concentration value at the downwind compartment 02 while they also decreased more rapidly in the upwind compartment 01 after the source was turned off. The highest indoor concentration and concentration fluctuation values were observed at the detectors located close to the windward walls, especially when the building windows were open. Experiments with and without natural ventilation suggested that infiltration and exfiltration of contaminants is much faster when the building windows are open, resulting to higher indoor concentration levels. Furthermore, mechanical ventilation tends to homogenize concentrations and suppress concentration fluctuations, leading to lower maximum concentration values.  相似文献   

16.
In the museum environment organic and inorganic chemicals can be found, which originate from both outside and inside the building. Many of the contaminants may cause adverse effects on works of art and human health, but in the past, pollution research in museums has focused on the protection of artifacts, while the risk assessment for humans has been neglected. Especially, the application of biocides leads to a conflict of interest: on the one hand cultural assets have to be protected against microorganisms, insects and rodents while on the other hand it is essential to provide healthy conditions for museum staff and visitors. It has recently been shown that the release of organic indoor pollutants from building products is one of the main reasons for deterioration of artifacts. In this work, we present the results of screening measurements on biocides in different locations of German museums. The major components that could be identified were DDT, PCP, lindane, methoxychlor, naphthalene, chlorinated naphthalenes, 1,4-dichlorobenzene, PCBs and arsenic. It is demonstrated that the application of chlorinated organic compounds and arsenic for preventive conservation is one of the prime reasons for indoor pollution in museums and provides a potential for exposure. However, the concentrations in air, dust and material are widely different and a health risk for humans has to be evaluated case by case.  相似文献   

17.
An improved ion chromatographic (IC) method has been developed for the separation of nitrate in filter extracts in the presence of high concentrations of nitrite. This analytical method was successfully used for an indirect measurement of ozone (O3) in outdoor and indoor air, following its collection using a nitrite-impregnated passive sampler. The limit of detection and the limit of quantification, using the modified IC method, were 6 microg l(-1) (3sigma) and 20 microg l(-1) (10sigma), respectively. Improved detection limits and low baseline noise were obtained with the use of eluent generator and high-capacity ion exchange column. The optimized method was used for assessing O3 concentration in both indoor and outdoor environments of 28 child care centers (CCCs) located in different parts of Singapore. The O3 concentrations ranged from 0.1 to 11.95 parts per billion (ppb) in indoor and from 3.2 to 21.7 ppb in outdoor environments during the study period. It was found that, among the CCCs investigated in this study, air-conditioned CCCs and those located in close proximity to traffic emissions had significantly lower O3 concentrations indoors.  相似文献   

18.
Indoor and outdoor ozone concentrations were measured from late May through October at three office buildings with very different ventilation rates. The indoor values closely tracked the outdoor values, and, depending on the ventilation rate, were 20 to 80 percent of those outdoors. The Indoor/outdoor data are adequately described with a mass balance model. The model can also be coupled with reported air exchange rates to estimate indoor/outdoor ratios for other structures. The results from this and previous studies indicate that Indoor concentrations are frequently a significant fraction of outdoor values. These observations, and the fact that most people spend greater than 90 percent of their time indoors, indicate that indoor ozone exposure (concentration × time) is greater than outdoor exposure for many people. Relatively Inexpensive strategies exist to reduce indoor ozone levels, and these could be implemented to reduce the public’s total ozone exposure.  相似文献   

19.
In the San Bernardino Mountains of southern California, ozone (O(3)) concentrations have been elevated since the 1950s with peaks reaching 600ppb and summer seasonal averages >100ppb in the 1970s. During that period increased mortality of ponderosa and Jeffrey pines occurred. Between the late 1970s and late1990s, O(3) concentrations decreased with peaks approximately 180ppb and approximately 60ppb seasonal averages. However, since the late 1990s concentrations have not changed. Monitoring during summers of 2002-2006 showed that O(3) concentrations (2-week averages) for individual years were much higher in western sites (58-69ppb) than eastern sites (44-50ppb). Potential O(3) phytotoxicity measured as various exposure indices was very high, reaching SUM00 - 173.5ppmh, SUM60 - 112.7ppmh, W126 - 98.3ppmh, and AOT40 - 75ppmh, representing the highest values reported for mountain areas in North America and Europe.  相似文献   

20.
Abstract

A research site for atmospheric chemistry and air pollution measurements was established at Pinnacle State Park in Addison, NY, in 1995. This paper presents an overview of the site characteristics and measurement program, as well as monthly average concentrations for many of the trace gas and aerosol pollutants over the full measurement period. Monthly averaged ozone concentrations range from values as low as 15 parts per billion (ppb) during cold-season months, to values approaching 50 ppb during some spring and summer months. Sulfur dioxide (SO2), oxides of nitrogen (NOx), and reactive odd nitrogen (NOy) all show distinct seasonal variation, with summertime monthly averages as low as 1–3 ppb, and wintertime monthly averages from 6–12 ppb. The variation in carbon monoxide (CO) is much smaller, with minimums of approximately 150 ppb and maximums only rarely exceeding 250 ppb. Data for three hydrocarbon species propane, benzene, and isoprene—are presented. Propane and benzene show higher monthly averaged concentrations in the winter and lower values in the summer, with values ranging over a factor of 4–5. Isoprene, on the other hand has much higher values during the summer season, sometimes a factor of 10 or more greater than concentrations measured in the winter. Monthly averaged plots for fine particulate matter (PM2.5) beginning in 1999 show a robust summer maximum and winter minimum, and roughly a factor of two difference between the two. An empirical measure of ozone production using the correlation of hour-averaged ozone and NOy data illustrates relatively robust ozone production during some, but not all, summertime months over the time period. Also, an analysis of the frequency distribution of the hours of maximum ozone concentration shows a strong mid-afternoon peak, as expected, but also a prominent secondary maximum centered around midnight. The secondary peak is interpreted as ozone transported from ozone-producing areas to the west, including Buffalo, Cleveland, Pittsburgh, and the Ohio Valley. Finally, SO2 concentrations as a function of wind direction clearly indicate maximum impacts when the winds are out of the south (Pittsburgh and Philadelphia), with a secondary peak when the winds are from the north-northeast, consistent with the locations of major SO2 emission sources in the region.  相似文献   