首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
The present study was carried out with the aim of evaluating the performance of six different aerosol samplers in terms of mass concentration, particle size distribution, and mass fraction for the international size-sampling conventions. The international size-sampling criteria were defined as inhalable, thoracic, and respirable mass fractions with 50% cutoff at an aerodynamic equivalent diameter of 100 μm, 10 μm, and 4 μm, respectively. Two Andersen, four total suspended particulate (TSP), two RespiCon, four PM10, two DustTrak, and two SidePak samplers were selected and tested to quantitatively estimate human exposure in a carefully controlled particulate matter (PM) test chamber. The overall results indicate that (1) Andersen samplers underestimate total suspended PM and overestimate thoracic and respirable PM due to particle bounce and carryover between stages, (2) TSP samplers provide total suspended PM as reference samplers, (3) TSP samplers quantified by a coulter counter multisizer provide no information below an equivalent spherical diameter of 2 μm and therefore underestimate respirable PM, (4) RespiCon samplers are free from particle bounce as inhalable samplers but underestimate total suspended PM, (5) PM10 samplers overestimate thoracic PM, and (6) DustTrak and SidePak samplers provide relative PM concentrations instead of absolute PM concentrations.  相似文献   

2.
T. Jayasekher   《Chemosphere》2009,75(11):1525-1530
Industrial processes discharge fine particulates containing organic as well as inorganic compounds into the atmosphere which are known to induce damage to cell and DNA, both in vitro and in vivo. Source and area specific studies with respect to the chemical composition, size and shape of the particles, and toxicity evaluations are very much limited. This study aims to investigate the trace elements associated with the aerosol particles distributed near to a coal burning thermal power plant and to evaluate their toxicity through Comet assay. PM10 (particles determined by mass passing an inlet with a 50% cut-off efficiency having a 10-μm aerodynamic diameter) samples were collected using respirable dust samplers. Twelve elements (Cr, Mn, Fe, Co, Ni, Cu, Zn, Cd, Pb, Se, Hg, and As) were analyzed using ICP-AES. Comet assay was done with the extracts of aerosols in phosphate buffered saline (PBS). Results show that Fe and Zn were found to be the predominant elements along with traces of other analyzed elements. Spherical shaped ultrafine particles of <1 μm aerodynamic diameter were detected through scanning electron microscope. PM10 particles near to the coal burning power plant produced comets indicating their potential to induce DNA damage. DNA damage property is found to be depending upon the chemical characteristics of the components associated with the particles besides the physical properties such as size and shape.  相似文献   

3.
Abstract

This investigation numerically examined the cutoff aerodynamic diameter (da50) and the sharpness (GSD) of the particle collection efficiency curve of impactors with a finite impaction plate diameter. Results revealed that the inertial impactors have a limited cutoff aerodynamic diameter at different air velocities. The extreme value of the cutoff aerodynamic diameter increases with the nozzle diameter (W)/the plate diameter (Dc). The computed da50/Dc values of the impactors increase with W/Dc at various Reynolds numbers (Re) and with the nozzle-toplate distance (S)/Dc when Re is 100. The value of GSD slightly increases with W/Dc for Re of 10 and 100, although the effect of S/Dc on GSD is not evident at various Res. The particle collection efficiency curve of the impactor with a lower Re is less sharp than that with a high Re at various W/Dc and S/Dc values. Statistical equations closely fitted the obtained numerical results for Res of 10–3000. The equations are useful for directly calculating the cutoff aerodynamic diameter and the sharpness of the particle collection efficiency curve for single round-nozzle impactors with a finite impaction Dc.  相似文献   

4.
Critical or activation diameters of laboratory generated organic aerosols composed of succinic acid, adipic acid and glucose were determined. Measurements of sodium chloride and ammonium sulfate aerosols were performed for comparison. Our experimental approach involved producing single component aerosol particles of a known size, and measuring the fraction of aerosol number concentrations (CN) that act as CCN at several supersaturations. The particle diameter (D50) at which the CCN/CN ratio of 0.50 is reached is defined as the critical, or activation, diameter. These experimentally derived diameters are compared with the theoretical critical diameter (DC). The results indicate that highly water-soluble organic compounds exhibit critical diameters that approach that of ammonium sulfate.  相似文献   

5.
Abstract

Aerosol size distributions from ferrous foundry cupola furnaces vary depending on semicontinuous process dynamics, time along the tap-to-tap cycle, dilution ratio, and the physical and chemical nature of the charge and fuel. All of these factors result in a highly time-dependent emission of particulate matter (PM) 2.5 µm or less in aerodynamic diameter (PM2.5)—even on a mass concentration basis. Control measures are frequently taken on the basis of low-reliability parameters such as emission factors and loosely established mass ratios of PM2.5 to PM 10 µm or less in aerodynamic diameter (PM10). The new environmental requirements could entail unexpected and undesired drawbacks and uncertainties in the meaning and effectiveness of process improvement measures. The development of process-integrated and flue-gas cleaning measures for reduction of particle emissions requires a better knowledge of generation mechanisms during melting. Available aerosol analyzers expand the range of control issues to be tackled and contribute to greatly reduce the uncertainty of engineering decisions on trace pollutant control. This approach combines real-time size distribution monitoring and cascade impactors as preseparators for chemical or morphological analysis. The results allow for establishing a design rationale and performance requirement for control devices. A number size distribution below 10 µm in aerodynamic equivalent diameter was chosen as the main indicator of charge influence and filter performance. Size distribution is trimodal, with a coarse mode more than 12 µm that contributes up to 30% of the total mass. A temporal series for these data leads to identification of the most relevant size ranges for a specific furnace (e.g., the most penetrating size range). In this cupola, this size range is between 0.32 and 0.77 µm of aerodynamic equivalent diameter and defines the pollution control strategy for metals concentrating within this size range. Scrap quality effect is best monitored at less than 0.2 µm in aerodynamic equivalent diameter and has been confirmed as strongly dependent on the physical state of the charge.  相似文献   

6.
A Two-stage Size Selective Inlet for use with hi-vol samplers was designed and tested. The inlet, which operates at a flow rate of 1.13 m3/min, is shown to have a cutpoint of 9.8 μm and a fractionation curve slope of 1.45. The cutpoint is well within the EPA suggested limits of 10 ± 1 μm. Fractionation is not affected by wind speed over the test range of 2-24 km/h.

Re-entrainment or bounce of solid particles is not of consequence. The difference in penetration of 20 μm aerodynamic diameter glass beads and liquid aerosols is less than 1% at all wind speeds.  相似文献   

7.
Abstract

The hygroscopic properties of the organic fraction of aerosols are poorly understood. The ability of organic aerosols to absorb water as a function of relative humidity (RH) was examined using data collected during the 1999 Big Bend Regional Aerosol and Visibility Observational Study (BRAVO). (On average, organics accounted for 22% of fine particulate matter with an aerodynamic diameter less than 2.5 µm (PM2.5) mass). Hourly RH exceeded 80% only 3.5% of the time and averaged 44%. BRAVO aerosol chemical composition and dry particle size distributions were used to estimate PM2.5 light scattering (Bsp) at low and high ambient RH. Liquid water growth associated with inorganic species was sufficient to account for measured Bsp for RH between 70 and 95%.  相似文献   

8.
The objective of the study was to determine the degree of microbiological contamination, type of microflora, bioaerosol particle size distribution, and concentration of endotoxins in dust in different types of composting plants. In addition, this study provides a list of indicator microorganisms that pose a biological threat in composting facilities, based on their prevalence within the workplace, source of isolation, and health hazards. We undertook microbiological analysis of the air, work surfaces, and compost, and assessed the particle size distribution of bioaerosols using a six-stage Andersen sampler. Endotoxins were determined using gas chromatography–mass spectrometry (GC-MS). Microbial identification was undertaken both microscopically and using biochemical tests. The predominant bacterial and fungal species were identified using 16S rRNA and ITS1/2 analysis, respectively.?The number of mesophilic microorganisms in composting plants amounted to 6.9 × 102–2.5 × 104 CFU/m3 in the air, 2.9 × 102–3.3 × 103 CFU/100 cm2 on surfaces, and 2.2 × 105–2.4 × 107 CFU/g in compost. Qualitative analysis revealed 75 microbial strains in composting plants, with filamentous fungi being the largest group of microorganisms, accounting for as many as 38 isolates. The total amount of endotoxins was 0.0062–0.0140 nmol/mg of dust. The dust fraction with aerodynamic particle diameter of 0.65–1.1 μm accounted for 28–39% of bacterial aerosols and 4–13% of fungal aerosols. We propose the following strains as indicators of harmful biological agent contamination: Bacillus cereus, Aspergillus fumigatus, Cladosporium cladosporioides, C. herbarum, Mucor hiemalis, and Rhizopus oryzae for both types of composting plants, and Bacillus pumilus, Mucor fragilis, Penicillium svalbardense, and P. crustosum for green waste composting plants. The biological hazards posed within these plants are due to the presence of potentially pathogenic microorganisms and the inhalation of respirable bioaerosol. Depending on the type of microorganism, these hazards may be aggravated or reduced after cleaning procedures.

Implications:?This study assessed the microbial contamination in two categories of composting plants: (1) facilities producing substrates for industrial cultivation of button mushrooms, and (2) facilities for processing biodegradable waste. Both workplaces showed potentially pathogenic microorganisms, respirable bioaerosol, and endotoxin. These results are useful to determine the procedures to control harmful biological agents, and to disinfect workplaces in composting plants.  相似文献   

9.
The University of Arizona and the Pima County Air Pollution Control District conducted a comparison study of the following aerosol samplers: a standard high-volume sampler, a high-volume sampler fitted with a size selective inlet, and a dichotomous virtual impactor. Over sixty samples were collected with the colocated samplers during the first six months of 1981. The concentration (μg/m3) of suspended particulate matter and of sulfate was determined for all the samples, while the concentration of four lithophilic elements (Ca, Fe, Mg, and K) was determined on one third of the samples. Well-defined linear relationships for suspended particulate matter and sulfate were found to exist between each of the three sample collection methods over the concentrafion range encountered in this study. For these samples, there were significant differences in the particulate mass and large particle lithophilic element concentrations collected by each device. However, sulfate values obtained from the three samplers were in excellent agreement with each other. This suggests that the inlet collection efficiency for large particles differs significantly for these three sampling devices. Since the size selective inlet and the dichotomous virtual impactor samplers are each designed for collection of inhalable particles (particles of 15 μm aerodynamic diameter and smaller), they would have been expected to measure approximately equivalent particle mass concentrations. Thus, these differences are important to those interested in selecting a method for measuring airborne particle mass concentrations.  相似文献   

10.
Abstract

Santiago de Chile is one of the most polluted South American cities, concentrating its pollution episodes during winter. Daily PM2.5 (particulate matter [PM] ≤ 2.5 μm in aerodynamic diameter) concentrations over 80 μg/m3 have been reached frequently since 1998. Despite several regulations introduced over the past 20 yr to improve the air quality, PM concentration levels remain high. In this work, sampling in downtown Santiago was conducted from April 1998 to August 2007 for PM2.5 and from October 2003 to March 2006 for PM10–2.5 (PM between 2.5 and 10 μm in aerodynamic diameter) with dichotomous samplers. Elemental analysis was performed on the samples with X-ray fluorescence. The resulting series of 859 samples and 216 elements identified were divided into semiannual periods and analyzed with factor analysis. Five factors are clearly discerned: soil, motor vehicles, residual oil, marine aerosols, and secondary sulfates. The soil factor in the fine fraction shows a clear increase from 2002 to 2006, whereas the coarse fraction of this factor shows a stable trend. The most probable cause for this trend is the growth in the number of vehicles in Santiago (6.5%/yr), which increases the resuspension of particles from the ground. Another cause for the increase is the growth in the construction activity (4.2%/yr). The motor vehicle factor in the fine fraction shows a decrease between 1998 and 2006. The decrease in the apportionment of this factor can be explained by the improvement in the vehicle fleet. In Santiago, the number of noncatalytic vehicles has been reduced from 389,000 in 2001 to 275,000 in 2006. The residual oil factor also shows a decrease between 1998 and 2006. The decrease could be attributed to the adoption of cleaner technologies and norms regarding gasoline and diesels.  相似文献   

11.
Abstract

It will be many years before the recently deployed network of fine particulate matter with an aerodynamic diameter less than 2.5 [H9262]m (PM2.5) Federal Reference Method (FRM) samplers produces information on nonattainment areas, trends, and source impacts. However, data on PM2.5 and its major constituents have been routinely collected in California for the past 20 years. The California Air Resources Board operated as many as 20 dichotomous (dichot) samplers for PM2.5 and coarse PM (PM10–2.5). The California Acid Deposition Monitoring Program (CADMP) collected 12-h-average PM2.5 and PM10 from 1988 to 1995 at ten urban and rural sites and 24-h-average PM2.5 at five urban sites since 1995. Beginning in 1994, the Children’s Health Study collected 2-week averages of PM2.5 in 12 communities in southern California using the Two-Week Sampler (TWS). Comparisons of collocated samples establish relationships between the dichot, CADMP, and TWS samplers and the 82-site network of PM2.5 FRM samplers deployed since 1999 in California. PM mass data from the different monitoring programs have modest to high correlation to FRM mass data, fairly small systematic biases and negative proportional biases ranging from 7 to 22%. If the biases are taken into account, all of the programs should be considered comparable with the FRM program. Thus, historical data can be used to develop long-term PM trends in California.  相似文献   

12.
Inhalable particulate matter (IP) samples have been collected in six U.S. cities in conjunction with an air pollution health study. The IP were collected using dichotomous virtual impactors in two size ranges: fine particles (FP) having aerodynamic diameter (da) <2.5 μm, and coarse particles (CP) with 2.5 μm < da < 15 μm. The mass measurements were determined by beta-gauge attenuation. The elemental composition of the FP and CP were determined by X-ray fluorescence. The means and distributions for FP and CP and selected elemental data highlight the similarities and differences that exist among these cities in the health study. Examining the temporal variations gives additional information on the meteorology and sources influencing the FP and CP fractions of Inhalable particle mass.

Differences in the concentration (and ratios) of selected elements have indicated the varying presence of crustal, steel industry, automotive, oceanic and fuel combustion sources in these cities. The noted variation in the concentrations and character of ambient aerosols in these cities are pertinent to interpreting differences in population exposures.  相似文献   

13.
ABSTRACT

The size range of airborne particles that is closely related to specific deposition regions in the human respiratory tract and excess lung burden of these deposited particles is associated with disease. Size-selective sampling, therefore, needs to be performed to assess the related health risks. Performance criteria applied to these samplers must be well characterized in order to provide accurate and reliable results. The PM10 samplers that have been used in place of the total suspended particulate samplers for the collection of ambient air particles are more relevant to potential inhalation hazards. In order to be certified, a PM10 sampler must meet reliable performance specifications, primarily the aerosol penetration test with liquid and solid particles in a wind tunnel (wind speeds of 2, 8, and 24 km/hr). This testing is intended to assure reasonable accuracy in aerosol measurements. However, the sampler performance under calm air conditions has not been well studied.

In the present study, the sampling heads of three devices—the Harvard impactor, the Personal Environmental Monitor (PEM), and the Sierra Andersen model 241 dichotomous sampler PM10 inlet head—were tested for aerosol separation efficiency. With the consideration of bias and imprecision of the measurements, five specimens of each type of sampler were chosen for performance testing, repeating the tests 5 times for each specimen. An ultrasonic atomizing nozzle was used to nebulize potassium sodium tartrate tetrahydrate and dioctyl phthalate particles as the solid and liquid challenge aerosols, respectively. The aerosol number concentrations and size distributions upstream and downstream of the samplers were measured by using an aerosizer calibrated against a settling velocity chamber. The results showed that among the samplers tested, the dichotomous sampler PM10 inlet head had the best fit to the PM10 convention, while the other two samplers not only appeared to have a steeper separation-curve slope but also had significant particle bounce when challenged with solid particles. Analysis of variance also confirmed the superiority of the dichotomous samplers. Surface-coating with oil or grease greatly reduced the problem of particle bounce.  相似文献   

14.
A mass transfer approach is used in developing a practical mathematical model of gaseous pollutant uptake by leaves in which a series of resistances is summed across a concentration difference. The body of information presented in this paper is directed to plant pathologists or physiologists in the field of vegetal-pollutant effects and to people interested in the natural removal of air pollutants by vegetation. Correlations are given to calculate the aerodynamic and the stomatal resistances to uptake, while both a qualitative investigation and quantitative estimates are made of the mesophyllic resistance. The factors which control the aerodynamic resistance, ra, are leaf size and wind speed, while the leaf physiology is the determinant of the stomatal resistance, rs . It is noted that the chemical reaction rate and pollutant diffusivity in the mesophyll control the mesophyllic resistance, rm, though the overall gas phase mesophyllic resistance, Hrm, is strongly a function of pollutant solubility in water. Finally, the overall model is compared to earlier experimental work on vegetal uptake of SO2.  相似文献   

15.
Particulate matter (PM) emissions from heavy-duty diesel vehicles (HDDVs) were collected using a chassis dynamometer/dilution sampling system that employed filter-based samplers, cascade impactors, and scanning mobility particle size (SMPS) measurements. Four diesel vehicles with different engine and emission control technologies were tested using the California Air Resources Board Heavy Heavy-Duty Diesel Truck (HHDDT) 5 mode driving cycle. Vehicles were tested using a simulated inertial weight of either 56,000 or 66,000 lb. Exhaust particles were then analyzed for total carbon, elemental carbon (EC), organic matter (OM), and water-soluble ions. HDDV fine (< or =1.8 microm aerodynamic diameter; PM1.8) and ultrafine (0.056-0.1 microm aerodynamic diameter; PM0.1) PM emission rates ranged from 181-581 mg/km and 25-72 mg/km, respectively, with the highest emission rates in both size fractions associated with the oldest vehicle tested. Older diesel vehicles produced fine and ultrafine exhaust particles with higher EC/OM ratios than newer vehicles. Transient modes produced very high EC/OM ratios whereas idle and creep modes produced very low EC/OM ratios. Calcium was the most abundant water-soluble ion with smaller amounts of magnesium, sodium, ammonium ion, and sulfate also detected. Particle mass distributions emitted during the full 5-mode HDDV tests peaked between 100-180 nm and their shapes were not a function of vehicle age. In contrast, particle mass distributions emitted during the idle and creep driving modes from the newest diesel vehicle had a peak diameter of approximately 70 nm, whereas mass distributions emitted from older vehicles had a peak diameter larger than 100 nm for both the idle and creep modes. Increasing inertial loads reduced the OM emissions, causing the residual EC emissions to shift to smaller sizes. The same HDDV tested at 56,000 and 66,000 lb had higher PM0.1 EC emissions (+22%) and lower PM0.1 OM emissions (-38%) at the higher load condition.  相似文献   

16.
The sampling and chemical analysis of the ambient aerosol collected in Denver, CO, for a 40-day period during November and December, 1978 are described in this report. Parameters included 12-hr TSP measurements, 24-hr respirable and inhalable mass measurements, and 4-hr measurements of mass and chemical species (NO3?, SO4 =, NH4 +, organic and elemental carbon as well as 13 chemical elements) in two size fractions i.e., less than 2.5 μm diameter (fine fraction) and larger than 2.5 μm diameter (coarse fraction). On the basis of the chemical analyses, it was possible to account for all particulate mass in both size fractions. In the fine fraction, the major constituents were organic carbon (21.6%), NH4NO3 (20.0%), elemental carbon (15.3%), (NH4)2SO4 (13.6%), and the remainder consisted primarily of soil-like material, lead salts, and adsorbed water. Three quarters of the coarse fraction consisted of soil-like material, with the remainder composed of the same species that dominated the fine fraction.  相似文献   

17.
A cyclone with a 47 mm after-filter has been developed for ambient air size-selective monitoring. It has been extensively evaluated with laboratory-generated aerosol. Variation of the pressure drop and 50% cut point with flow rate show that the cyclone operates in a single flow regime with a vortex in the outlet flow. The particle size cutoff curve is comparable in sharpness to a cascade impactor and is the same for solid or liquid particles. At 21.7 L/min, D 50 is 2.5μm and at 15.4 L/min, D 50 is 3.5 μm. Collection efficiency data for flow rates from 8 to 27 L/min fit a universal curve when plotted vs. the normalized particle diameter, (D-D 50)/D 50 Reentrainment of previously deposited particles is less than 1 % of the loading per day. In field tests the cyclone has proved to be a very satisfactory size-selective sampler.  相似文献   

18.
Abstract

Protocols have been developed and applied for the generation of aerosols that are likely to be comparable to those encountered in field settings for the calibration of easily transportable/portable real-time particle monitors. Aerosols generated were simulated environmental tobacco smoke, cedar wood smoke, cooking oil fumes, and propane stove particles. The time-integrated responses of three nephelometers and a monitor for particle-bound polynuclear aromatic hydrocarbons (PAH) were compared with gravimetric respirable suspended particulate matter (RSP) in a controlled-atmosphere chamber. In general, the monitor responses increased linearly with increasing mass concentration. However, the two monitors that reported mass per volume concentrations tended to overreport the actual RSP concentrations by factors up to 4.4. The real-time PAH monitor did not respond to cooking oil fumes, indicative of little PAH being present in the aerosol. One of the monitors that has been used in a variety of studies reported in the literature (DustTrak) was collocated with gravimetric RSP samplers in several hospitality venues in the Louisville, KY, area. Field studies indicated that the units overreported actual RSP concentrations by factors of 2.6–3.1, depending on whether the sampling was conducted in the nonsmoking or smoking sections of the facilities.  相似文献   

19.
Two single round nozzle impactors have been developed for use in Harvard’s indoor air pollution health study. Both impactors operate at flow rates of 4 L/m and are nearly identical, differing only in their cut sizes of 2.5 μm and 10 μm aerodynamic diameters. Two identical cascaded stages of the same cut size are used to obtain sharp cut-off characteristics. The particles are deposited on impaction plates made of oil impregnated, porous material to reduce particle bounce and are discarded. Only the particles collected on the afterfilter are analyzed. Special care has been taken to collect the particles uniformly on the afterfilter to aid in particle analysis.

The jmpactors were calibrated with a vibrating orifice monodisperse aerosol generator. However, due to the sharp cut of the impactors, doublets and triplets in the calibration aerosols, even in small quantities, gave erroneous calibration curves. Therefore, the number of doublets and triplets in the challenging aerosols were measured and appropriate corrections made to the calibration curves.  相似文献   

20.
Abstract

Size-resolved particulate matter (PM) emitted from light-duty gasoline vehicles (LDGVs) was characterized using filter-based samplers, cascade impactors, and scanning mobility particle size measurements in the summer 2002. Thirty LDGVs, with different engine and emissions control technologies (model years 1965–2003; odometer readings 1264–207,104 mi), were tested on a chassis dynamometer using the federal test procedure (FTP), the unified cycle (UC), and the correction cycle (CC). LDGV PM emissions were strongly correlated with vehicle age and emissions control technology. The oldest models had average ultrafine PM0.1 (0.056- to 0.1-μm aerodynamic diameter) and fine PM1.8 (≤1.8-μm aerodynamic diame ter) emission rates of 9.6 mg/km and 213 mg/km, respectively. The newest vehicles had PM0.1 and PM1.8 emis sions of 51 μg/km and 371 μg/km, respectively. Light duty trucks and sport utility vehicles had PM0.1 and PM1.8 emissions nearly double the corresponding emission rates from passenger cars. Higher PM emissions were associated with cold starts and hard accelerations. The FTP driving cycle produced the lowest emissions, followed by the UC and the CC. PM mass distributions peaked between 0.1-and 0.18-μm particle diameter for all vehicles except those emitting visible smoke, which peaked between 0.18 and 0.32 μm. The majority of the PM was composed of carbonaceous material, with only trace amounts of water-soluble ions. Elemental carbon (EC) and organic matter (OM) had similar size distributions, but the EC/OM ratio in LDGV exhaust particles was a strong function of the adopted emissions control technology and of vehicle maintenance. Exhaust from LDGV classes with lower PM emissions generally had higher EC/OM ratios. LDGVs adopting newer technologies were characterized by the highest EC/OM ratios, whereas OM dominated PM emissions from older vehicles. Driving cycles with cold starts and hard accelerations produced higher EC/OM ratios in ultrafine particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号