首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
W.T. Tsai  C.Y. Chang 《Chemosphere》1994,29(12):2507-2515
The effects of relative humidity (RH) on the adsorption of methylene chloride (METH) and 1,1,1-trichloroethane (TCEA) on two commercial activated carbons, made from bituminous coal (carbon BPL) and coconut shell (carbon PCB), were studied. Three levels of RH were tested by tracking the breakthrough curves of each adsorbate eluted from a fixed-bed adsorption column. Adsorption capacities for these adsorbates were decreased with increase of RH. The magnitude of the effect of water vapor on adsorption is greater for carbon BPL and METH than for carbon PCB and TCEA. The results of the effect of water vapor on the adsorption capacity observed in this study were further examined based on the chemical characterization of activated carbons and the fundamental physical differences between the adsorbates.  相似文献   

2.
Activated carbon filters were used to concentrate atmospheric mixtures of acrolein, methyl sulfide, and n-propyl mercaptan. Removal efficiency and carbon capacity for each of the odor compounds were investigated using two different carbons, Cliff char {4-10 mesh) and Barnebey-Cheney (C-4). A closed system was devised to establish a known atmospheric odor concentration for each filter run. Solvent extraction techniques were employed to desorb and recover the odor compounds from the carbon filters. All quantitative analyses were conducted with gas liquid chromatography utilizing the hydrogen flame ionization detector. The removal studies conducted indicate that the efficiency of removal of a carbon filter is essentially 100 percent up to the point of filter breakthrough. This breakthrough point is governed by the filter’s capacity for a particular compound. This study indicated that the filter capacity is dependent both on the type of carbon employed and the particular odor compound adsorbed. Solvent recovery of the odor compounds from the carbons varied from 0 to 4.5 percent for the mercaptan up to 96 to 98 percent for acrolein. Percent recovery was found to vary for a given odor compound with different carbons and for a given carbon with different odor pollutants.  相似文献   

3.
Methyl bromide (MeBr) is commonly used for fumigating structures and commodities. Emission of MeBr during such treatments is environmentally detrimental because of the reaction of MeBr with stratospheric ozone. In this study we evaluated adsorption of MeBr and methyl iodide (MeI) – a potential MeBr replacement, on five commercial activated carbons, and studied water-initiated catalytic decomposition of adsorbed fumigants. All carbon samples showed great adsorption affinity to MeBr and MeI, with the adsorption capacity for MeI several times greater than that for MeBr on the same carbon. For the same fumigant, adsorption was affected by the type of carbon and the concentration of fumigant. Water initiated decomposition of both fumigants, liberating Br or I as a transformation product. The rate of decomposition increased with increasing temperature, and was also influenced by the carbon type. The half-life of MeBr or MeI on Centaur, a catalytically modified carbon, was <2 h at 80°C. The rapid decomposition of MeBr and MeI on wet carbons at elevated temperatures may be used to detoxify these fumigants after adsorption on activated carbons.  相似文献   

4.
Duan H  Yan R  Koe LC  Wang X 《Chemosphere》2007,66(9):1684-1691
In order to evaluate the combined effect of adsorption and biodegradation of H(2)S on activated carbon surface in biotrickling filtration, four laboratory-scale biofiltration columns were operated simultaneously for 120h to investigate the mechanisms involved in treating synthetic H(2)S streams using biological activated carbon (BAC). The first three columns (A, B, C) contained a mixture of activated carbon and glass beads, with the carbons (BAC or virgin activated carbon (VAC)) and conditions (with or without liquid medium recirculation) differentiated. The last column (D) used 100% glass beads with liquid medium recirculation. Air streams containing 45ppmv H(2)S were passed through the columns at 4s of gas retention time (GRT) and liquid flow rate was set at 0.71mlmin(-1). Column D got its breakthrough in 3min of operation, indicating a negligible contribution of glass beads to the adsorption of H(2)S. The removal efficiency (RE) of Columns B and C using VAC dropped quickly to 30% within the first 8h, and afterwards continued to drop further but slowly. Column A using BAC stayed at 25% of RE throughout the operation time. A thorough investigation of the H(2)S oxidation products, i.e., various S species in both aqueous (recirculation media) and solid phases (BAC and VAC), was conducted using ICP-OES, IC, XRF, and CHNS elemental analyzer. BAC demonstrated a better performance than columns with adsorption only. Water film was found to enhance H(2)S removal. The percentage of sulphate in the total sulphur of the BAC system improved to twice of that of VAC system, indicating sulphate is the main product of H(2)S biofiltration. The observed pH drop in BAC system double confirmed that the presence of biodegradation in the biofilm over carbon surface did profound effect on the oxidation of H(2)S, compare to the systems with adsorption only.  相似文献   

5.
Jiang X  Yan R  Jay JH 《Chemosphere》2008,73(5):698-704
Exhausted carbon coming from the H2S adsorption process is a big environmental problem in Wastewater Treatment Plants. In this study, reusing exhausted carbon as a carrier of sulfide-oxidizing bacteria in lab-scale biofilters was evaluated. The exhausted carbons from different heights of the adsorption bed have different exhaustion extents, i.e. characteristics in terms of sulfur content, pH and porosity. Therefore, four biofilters were packed separately with exhausted carbon from top, middle, bottom of H2S adsorption bed, and a mixture of the three, to investigate the suitability for further H2S biofiltration. The results showed a quick startup in these biofilters (approximately 80 h). The numbers of sulfide-oxidizing bacteria immobilized on activated carbon were approximately 4.8, 9.2 and 14 x 108 CFU g-1 top, middle and bottom carbon after the 240-h operation, respectively. In addition, the biofilters demonstrated a rapid recovery to the original removal efficiency (RE) within 2 h after the H2S spike loadings. After a 110-h shutdown, the RE was rapidly recovered for all the biofilters within 5 h, with a shorter time (1 h) observed for the bottom carbon biofilter. The H2S removal mechanism of these biofilters was studied through a full analysis of sulfur products in both liquid (recycling medium) and activated carbon, and variable characterization of activated carbon before and after biofiltration. This study shows that the exhausted carbon-based biofilter is a feasible and economical alternative to conventional odor biofiltration.  相似文献   

6.
In this study, biofiltration using a natural wood chip medium and a commercial biofiltration medium was evaluated for the removal of moderate concentrations of hydrogen sulfide (H2S) (up to 100 parts per million by volume [ppmv]) in the presence of significant concentrations of ammonia (NH3). These levels were chosen as representative of wastewater lift station emissions in the Brownsville, TX, area. NH3-removing portions of the biofilms may compete with H2S-removing portions and inhibit H2S removal. H2S process removal efficiencies for the commercial and natural media ranged from 90 to 96% depending on inlet loading and media type and bed height. Kinetic analysis of the H2S removal process followed apparent first-order reaction behavior. The average first-order reaction rates were 0.03 sec(-1) for the commercial medium and 0.09 sec(-1) for the natural medium. Pressure drops across the columns ranged from 0.41 in. H2O/ft for the commercial medium to 1.41 in. H2O/ft for the natural medium. NH3 gas levels of up to 80 ppmv did not affect the H2S removal process efficiency, and calculated kinetic rate constants for H2S removal remained almost the same. The NH3 gas also was removed simultaneously with the H2S up to 98% removal efficiency by the commercial medium.  相似文献   

7.
This study selected biosolids from a petrochemical waste-water treatment plant as the raw material. The sludge was immersed in 0.5-5 M of zinc chloride (ZnCl2) solutions and pyrolyzed at different temperatures and times. Results indicated that the 1-M ZnCl2-immersed biosolids pyrolyzed at 500 degrees C for 30 min could be reused and were optimal biosolid adsorbents for benzene adsorption. Pore volume distribution analysis indicated that the mesopore contributed more than the macropore and micropore in the biosolid adsorbent. The benzene adsorption capacity of the biosolid adsorbent was 65 and 55% of the G206 (granular-activated carbon) and BPL (coal-based activated carbon; Calgon, Carbon Corp.) activated carbons, respectively. Data from the adsorption and desorption cycles indicated that the benzene adsorption capacity of the biosolid adsorbent was insignificantly reduced compared with the first-run capacity of the adsorbent; therefore, the biosolid adsorbent could be reused as a commercial adsorbent, although its production cost is high.  相似文献   

8.
The traditional technologies for odor removal of thiol usually create either secondary pollution for scrubbing, adsorption, and absorption processes, or sulfur (S) poisoning for catalytic incineration. This study applied a laboratory-scale radio-frequency plasma reactor to destructive percentage-grade concentrations of odorous dimethyl sulfide (CH3SCH3, or DMS). Odor was diminished effectively via reforming DMS into mainly carbon disulfide (CS2) or sulfur dioxide (SO2). The removal efficiencies of DMS elevated significantly with a lower feeding concentration of DMS or a higher applied rf power. A greater inlet oxygen (O2)/DMS molar ratio slightly improved the removal efficiency. In an O2-free environment, DMS was converted primarily to CS2, methane (CH4), acetylene (C2H2), ethylene (C2H4), and hydrogen (H2), with traces of hydrogen sulfide (H2S), methyl mercaptan (CH3SH), and dimethyl disulfide. In an O2-containing environment, the species detected were SO2, CS2, carbonyl sulfide, carbon dioxide (CO2), CH4, C2H4, C2H2, H2, formaldehyde, and methanol. Differences in yield of products were functions of the amounts of added O2 and the applied power. This study provided useful information for gaining insight into the reaction pathways for the DMS dissociation and the formation of products in the plasmolysis and conversion processes.  相似文献   

9.
活性炭吸附硫化氢及微波辐照解吸研究   总被引:13,自引:0,他引:13  
王学谦  宁平 《环境污染与防治》2001,23(6):274-275,279
研究了两种活性炭对硫化氢的平衡吸附性能力,并对活性炭床层的穿透性进行了考察;吸附饱和和活性炭在微波辐射的作用下进行解吸。实验表明,解吸效率与微波作用时间及温度有关,在本实验条件下H2S解吸效率达90.1%。  相似文献   

10.
Adsorption of hydrogen sulfide on montmorillonites modified with iron   总被引:7,自引:0,他引:7  
Sodium-rich montmorillonite was modified with iron in order to introduce active centers for hydrogen sulfide adsorption. In the first modification, interlayer sodium cations were exchanged with iron. In another modification, iron oxocations were introduced to the clay surface. The most elaborated modification was based on doping of iron within the interlayer space of aluminum-pillared clay. The modified clay samples were tested as hydrogen sulfide adsorbents. Iron-doped samples showed a significant improvement in the capacity for H2S removal, despite of a noticeable decrease in microporosity compared to the initial pillared clay. The smallest capacity was obtained for the clay modified with iron oxocations. Variations in adsorption capacity are likely due to differences in the chemistry of iron species, degree of their dispersion on the surface, and accessibility of small pores for H2S molecule. The results suggest that on the surface of iron-modified clay hydrogen sulfide reacts with Fe(+3) forming sulfides or it is catalytically oxidized to SO2 on iron (hydro)oxides. Subsequent oxidation may lead to sulfate formation.  相似文献   

11.
The effects of water vapor on binary vapor adsorption of toluene and methylene chloride by activated carbon were investigated on a bench-scale experimental system. Three levels of relative humidity (15, 65 and 90 percent) in conjunction with different concentrations of individual adsorbates (from 400 to 1200 ppmv) were tested by tracing the breakthrough curves of each adsorbate eluted from a fixed-bed adsorber. The adsorption capacities of the activated carbon tested for each adsorbate under the various conditions were obtained from calculations based on area integration of the breakthrough curves. It was found that with increasing relative humidity, the shape of breakthrough curves was asymmetrically distorted and the width of the breakthrough curves was broadened for toluene and steepened for methylene chloride. The adsorption capacities for both toluene and methylene chloride were decreased with the increase of relative humidity. The magnitude of the effect of water vapor is greater at the lower toluene concentration and at the higher concentration of methylene chloride. The mechanisms of water vapor influence on the process of multicomponent vapor adsorption are discussed.  相似文献   

12.
A pilot study was conducted to compare odor emissions from a windrow process and an aerated static pile and to determine the odor reduction efficiency of a pilot two-phase biofilter for odor control of biosolids composting. Chemical compounds identified as responsible for odors from biosolids composting include ammonia, dimethyl disulfide, carbon disulfide, formic acid, acetic acid, and sulfur dioxide (or carbonyl sulfide). Aeration was found to reduce the concentration of ammonia, formic acid, and acetic acid by 72, 57, and 11%, respectively, compared with a nearby windrow, while dimethyl sulfide, carbon disulfide, and sulfur dioxide (or carbonyl sulfide) concentrations were below detection limits. Using dilution-to-threshold olfactometry, aeration followed by biofiltration was found to reduce the odor from biosolids composting by 98%. Biofiltration also altered the character of odor emissions from biosolids composting, producing a less offensive odor with an earthy character. Biofiltration was found to reduce the concentration of ammonia, dimethyl disulfide, carbon disulfide, formic acid, acetic acid, and sulfur dioxide (or carbonyl sulfide) by 99, 90, 32, 100, 34, and 100%, respectively. The concentrations of those odorants were estimated to be 3700, 110000, 26,37,5, and 1.2 times reported human detection limits before the two-phase biofilter, respectively, and 42,9600,18,0,3, and 0 times human detection limits after the biofilter, respectively.  相似文献   

13.
采用溴化钾、碘化钾和硫磺对竹活性炭掺杂改性,利用电感耦合等离子体发射光谱仪测定滤液中汞离子浓度,用除汞效率和吸附容量评价活性炭对溶液中汞离子的吸附性能,探讨其吸附机理。结果表明,掺杂改性明显提高了竹活性炭的除汞性能。原竹活性炭的除汞效率为78.6%,吸附容量为2.210 mg/g;经碘化钾、溴化钾和硫磺掺杂改性后的竹活性炭除汞效率分别为94.3%、93.8%和88.8%,吸附容量分别为2.830、2.813和2.663 mg/g;经溴化钾(碘化钾)和硫磺联合改性的竹活性炭对水溶液中汞离子的吸附性能性能又有提高,其中以先载硫后载溴化钾的方法除汞效果最好,除汞效率达96.6%,吸附容量为2.898 mg/g。  相似文献   

14.
Abstract

Carbonyl sulfide (COS) is an odor-causing compound and hazardous air pollutant emitted frequently from wastewater treatment facilities and chemical and primary metals industries. This study examined the effectiveness of biofiltration in removing COS. Specific objectives were to compare COS removal efficiency for various biofilter media; to determine whether hydrogen sulfide (H2S), which is frequently produced along with COS under anaerobic conditions, adversely impacts COS removal; and to determine the maximum elimination capacity of COS for use in biofilter design. Three laboratory-scale polyvinyl chlo-ride biofilter columns were filled with up to 28 in. of biofilter media (aged compost, fresh compost, wood chips, or a compost/wood chip mixture). Inlet COS ranged from 5 to 46 parts per million (ppm) (0.10–9.0 g/m3fihr). Compost and the compost/wood chip mixture produced higher COS removal efficiencies than wood chips alone. The compost and compost/wood chip mixture had a shorter stabilization times compared with wood chips alone. Fresh versus aged compost did not impact COS removal efficiency. The presence of H2S did not adversely impact COS removal for the concentration ratios tested. The maximum elimination capacity is at least 9 g/m3·hr for COS with compost media.  相似文献   

15.
Choi KJ  Kim SG  Kim CW  Kim SH 《Chemosphere》2005,58(11):1535-1545
Removal performances of endocrine disrupting chemicals (EDC) such as amitrol, nonylphenol, and bisphenol-A were evaluated in this study using granular activated carbon (GAC) adsorption. This study found that GAC adsorption was effective in removal of EDCs with high Kow value. Nonylphenol and bisphenol-A were effectively adsorbed onto all carbons (including the used carbons) tested in this study. As indicated by Kow value, nonylphenol was more effectively adsorbed than bisphenol-A. The coal-based carbon was found more effective than other carbons in the adsorption of nonylphenol and bisphenol-A due to its larger pore volume. The adsorption capacity reduced with the operation year, and the extent of the reduction was different depending upon the carbon type and the operation year. Amitrol was effectively removed by biological degradation, but was poorly adsorbed. Since the microbes residing at the used carbons already accustomed to amitrol, the used carbons removed amitrol better than the virgin carbons. Although the coal-based carbon showed the best removal performance of amitrol, GAC adsorption could not be recommended for amitrol removal because considerable portion of incoming amitrol (9–87%) passed through GAC adsorption column. According to this study, pore volume mainly influenced the adsorption capacity, but the surface charge was also important due to electrical interaction. The adsorption parameters for nonylphenol and bisphenol-A provided by this study could be valuable when GAC adsorption was considered to handle an accidental spill of nonylphenol and bisphenol-A.  相似文献   

16.
Abstract

This study selected biosolids from a petrochemical waste-water treatment plant as the raw material. The sludge was immersed in 0.5-5 M of zinc chloride (ZnCl2) solutions and pyrolyzed at different temperatures and times. Results indicated that the 1-M ZnCl2-immersed biosolids pyrolyzed at 500 °C for 30 min could be reused and were optimal biosolid adsorbents for benzene adsorption. Pore volume distribution analysis indicated that the mesopore contributed more than the macropore and micropore in the biosolid adsorbent. The benzene adsorption capacity of the biosolid adsorbent was 65 and 55% of the G206 (granular-activated carbon) and BPL (coal-based activated carbon; Calgon, Carbon Corp.) activated carbons, respectively. Data from the adsorption and desorption cycles indicated that the benzene adsorption capacity of the biosolid adsorbent was insignificantly reduced compared with the first-run capacity of the adsorbent; therefore, the biosolid adsorbent could be reused as a commercial adsorbent, although its production cost is high.  相似文献   

17.
Hydrogen sulfide (H2S) generation in construction and demolition (C&D) debris landfills has been associated with the biodegradation of gypsum drywall. Laboratory research was conducted to observe H2S generation when drywall was codisposed with different C&D debris constituents. Two experiments were conducted using simulated landfill columns. Experiment 1 consisted of various combinations of drywall, wood, and concrete to determine the impact of different waste constituents and combinations on H2S generation. Experiment 2 was designed to examine the effect of concrete on H2S generation and migration. The results indicate that decaying drywall, even alone, leached enough sulfate ions and organic matter for sulfate-reducing bacteria (SRB) to generate large H2S concentrations as high as 63,000 ppmv. The codisposed wastes show some effect on H2S generation. At the end of experiment 1, the wood/drywall and drywall alone columns possessed H2S concentrations > 40,000 ppmv. Conversely, H2S concentrations were < 1 ppmv in those columns containing concrete. Concrete plays a role in decreasing H2S by increasing pH out of the range for SRB growth and by reacting with H2S. This study also showed that wood lowered H2S concentrations initially by decreasing leachate pH values. Based on the results, two possible control mechanisms to mitigate H2S generation in C&D debris landfills are suggested.  相似文献   

18.
The effects of hydrogen sulfide (H2S) diffusion into activated sludge (AS) on odor and volatile organic compound (VOC) concentrations in offgas were studied over an 8-week period. Most VOCs detected in the offgas of both aeration tanks were aromatic hydrocarbons. The VOC concentrations generally decreased when H2S was introduced to the AS compared with the control, indicating a negative effect of H2S on VOC removal. Two volatile organic sulfur compounds present in the test AS offgas showed an increase followed by a decrease during H2S peak loads. Six VOCs and odor concentration increased during the introduction of an H2S peak; however no correlation was observed between H2S and odor concentration. The increase in odor concentration resulted from the increase in the concentration of six aromatic VOCs, which had their removal slowed down during a 100-ppmv H2S peak. Activated sludge diffusion provides effective H2S removal with minimal affect on odor emissions.  相似文献   

19.
Conversion of sewage sludge to activated carbon is attractive as an alternative method to ocean dumping for the disposal of sewage sludge. Injection of activated carbon upstream of particulate matter control devices has been suggested as a method to remove elemental mercury from flue gas. Activated carbon was prepared using various activation temperatures and times and was tested for their mercury adsorption efficiency using lab-scale systems. To understand the effect of the physical property of the activated carbon, its mercury adsorption efficiency was investigated as a function of its Brunauer–Emmett–Teller (BET) surface area. Two simulated flue gas conditions, (1) without hydrogen chloride (HCl) and (2) with 20 ppm HCl, were used to investigate the effect of flue gas composition on the mercury adsorption capacity of activated carbon. Despite very low BET surface area of the prepared sewage sludge activated carbons, their mercury adsorption efficiencies were comparable under both simulated flue gas conditions to those of pinewood and coal activated carbons. After injecting HCl into the simulated flue gas, all sewage sludge activated carbons demonstrated high adsorption efficiencies, that is, more than 87%, regardless of their BET surface area.

Implications: We tested activated carbons prepared from dried sewage sludge to investigate the effect of their physical properties on their mercury adsorption efficiency. Using two simulated flue gas conditions, we conducted mercury speciation for the outlet gas. We found that the sewage sludge activated carbon had mercury adsorption efficiency comparable to pinewood and coal activated carbons, and the presence of HCl minimized the effect of physical property of the activated carbon on its mercury adsorption efficiency.  相似文献   


20.
研究了载硫温度、硫炭比(简称S/C),吸附温度等因素对载硫活性炭的硫含量、脱汞能力以及硫损失的影响,探讨载硫活性炭制备的工艺条件优化。结果表明,不同载硫温度下制备的载硫活性炭的气态Hg0吸附能力远强于原料活性炭;载硫温度不同时,负载到活性炭孔隙或表面上的硫的形态不同,导致了脱汞能力的差异,较合适的载硫温度为350℃;S/C为5%(质量分数,下同)时,随着吸附温度的升高,载硫活性炭的气态Hg0吸附量降低;在一定的载硫温度下,原料中S/C越高时,制备的载硫活性炭的硫含量越高、气态Hg0吸附能力越强,但其硫损失率也越高,从实际的使用效果来看,较合适的S/C为10%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号