首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 632 毫秒
1.
P.E. desRosiers  A. Lee 《Chemosphere》1986,15(9-12):1313-1323
PCBs, PCDDs, and PCDFs are subject to new regulations promulgated under the Toxic Substances Control Act and the Resource Conservation and Recovery Act. The finding of PCDDs and PCDFs in PCBs could restrict disposal options for PCBs. A review of major fire incidents in the U.S., indicates that PCDDs have been found only in the Binghamton, N.Y., transformer fire incident. Laboratory combustion studies further support PCDFs formation from PCBs and PCDDs from chlorobenzenes. No PCDDs were found in analyses of fluids from transformers involved in transformer fire incidents. PCDFs do not appear to increase in PCBs askarel fluids from normal usage in electrical equipment.  相似文献   

2.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) contained in the smoke generated from rice straw burning in post-harvest paddy fields in Japan were analyzed to determine their congener profiles. Both the apportionment of toxic equivalent (TEQ) by using indicative congeners and the comparison of the homolog profiles showed that the PCDDs/PCDFs/DL-PCBs present in the rice-straw smoke were greatly influenced by those present as impurities in pentachlorophenol (PCP) and chlornitrofen (CNP, 4-nitrophenyl-2,4,6-trichlorophenyl ether) formulations that had been widely used as herbicides in paddy fields in Japan. Further, in order to investigate the effects of paddy-field soil on the PCDDs/PCDFs/DL-PCBs present in rice-straw smoke, PCDD/PCDF/DL-PCB homolog profiles of rice straw, rice-straw smoke and paddy-field soil were compared. Rice-straw smoke was generated by burning rice straw on a stainless-steel tray in a laboratory. The results suggested that the herbicides-originated PCDDs/PCDFs/DL-PCBs and the atmospheric PCDDs/PCDFs/DL-PCBs contributed predominantly to the presence of PCDDs/PCDFs/DL-PCBs in the rice-straw smoke while the contribution of PCDDs/PCDFs/DL-PCBs formed during rice straw burning was relatively minimal. The major sources of the PCDDs/PCDFs/DL-PCBs found in the rice-straw smoke were attributed primarily to the paddy-field soil adhered to the rice straw surface and secondarily to the air taken by the rice straw. The principal component analysis supported these conclusions. It is concluded that rice straw burning at paddy fields acts as a driving force in the transfer of PCDDs/PCDFs/DL-PCBs from paddy-field soil to the atmosphere.  相似文献   

3.
Kim SC  Jeon SH  Jung IR  Kim KH  Kwon MH  Kim JH  Yi JH  Kim SJ  You JC  Jung DH 《Chemosphere》2001,43(4-7):701-707
This study was carried out to examine the formation and the emission status of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) in the flue gases of commercial-scale municipal solid waste (MSW) incinerators, and thus to provide the engineering data for the reduction of PCDDs/PCDFs emitted from MSW incinerators. The formation concentrations of the PCDDs/PCDFs generated at the outlet of waste heat boilers (WHB) were in the range of 1.18-29.61 ng-TEQ/N m3 (average 5.75 ng-TEQ/N m3), while the emission concentrations at the stacks were in the range of 0.026-4.548 ng-TEQ/N m3 (average 0.924 ng-TEQ/N m3). Two major 2,3,7,8-substituted congeners were 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF, and their concentrations were up to 50% and 64% of total TEQ values at the outlet of WHB and the stack, respectively. From the results of multi-regression analysis, the formation concentration of PCDDs/PCDFs could be predicted as follows with the correlation factor of r2 = 0.962: PCDDs/PCDFs (ng-TEQ/N m3) = 3.036 (Cl) + 0.094 (T1) - 0.472 (Combustibles) + 0.059 (CO) - 0.039 (THC) - 3.366 (H) + 22.157, where T1 (degrees C) is the temperature at the outlet of the WHB. Cl, Combustibles and H are given as percentages and the others are in parts per million.  相似文献   

4.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

5.
Yang J  Shin D  Park S  Chang Y  Kim D  Ikonomou MG 《Chemosphere》2002,46(3):419-428
We determined breast milk concentration of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in 24 mothers living in Korea, and assessed the maternal body burden based on PCDDs/PCDFs and PCBs concentrations in breast milk and an infant intake rate through breast-feeding based on their concentration in breast milk. PCDDs/PCDFs and PCBs levels in breast milk from primipara mothers were found to be higher than those from multipara mothers. For total PCDDs/PCDFs TEQ level, 2,3,4,7,8-PeCDD was the predominant congener, and the proportion of 2,3,7,8-TCDD was less than 3% of total PCDDs/PCDFs TEQ level. For PCBs TEQ level, PCB-126 was the predominant congener. Maternal body burden levels of PCDDs/PCDFs and PCBs based on their concentrations in breast milk were 268-622 TEQ ng. The daily dioxin intakes of mothers were predicted to be 0.78-2.18 TEQ pg/kg/day for PCDDs/PCDFs and 0.34-0.66 TEQ pg/kg/ day for PCBs. For the first year, the body burden of an infant was predicted to be 212 TEQ ng and the daily intake of an infant was predicted to be 85 TEQ pg/kg/day, assuming the mean dioxin-related compounds concentration (27.54 TEQ pg/g fat).  相似文献   

6.
Hatanaka T  Imagawa T  Takeuchi M 《Chemosphere》2003,51(10):1041-1046
Combustion experiments in a laboratory-scale fluidized-bed reactor were conducted to elucidate the effects of copper chloride as a catalyst on polychlorinated dibenzo-p-dioxins (PCDDs) formation in municipal waste incineration. We used model wastes with and without copper chloride (CuCl2 · 2H2O), both of which contained polyvinyl chloride as a chlorine source. Combustion temperature was set to 900 °C, and the amount of air supplied was twice the stoichiometric ratio. The experimental setup was carefully planned to suppress the influences of experimental conditions except the waste composition. Results of these experiments showed that copper chloride in the waste increased the amount of PCDDs formed and made the homologue profile to shift towards the highly chlorinated species. Copper chloride contributes to the PCDDs formation by promoting chlorination, whereby the reaction is important in that organic matter is chlorinated directly by copper compounds. Copper chloride did not exert a great influence on the isomer distribution patterns of PCDDs, while there appeared a significant difference in the case of PCDFs. This points out the difference of the major formation mechanisms between PCDDs and PCDFs. PCDDs are less formed by the catalytic reactions from carbon/polycyclic aromatic hydrocarbons than PCDFs in our experimental conditions.  相似文献   

7.
Osako M  Kim YJ  Lee DH 《Chemosphere》2002,48(8):849-856
A field investigation by boring was carried out in a landfill site primarily with municipal solid waste incineration residue. From the collected core samples, vertical profiles of homologous content of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) in the landfill layer were traced and the behavior of PCDDs/PCDFs was examined. In addition, a pilot-scale study was conducted on the PCDDs/PCDFs leached from incineration fly ash and the treated one using large landfill simulation columns (lysimeters) and the leaching behavior of PCDDs/PCDFs was examined. As a result, it was found that the coexistence of dissolved coloring constituents (DCCs), which might be composed of constituents like dissolved humic matters having strong affinity for hydrophobic organic pollutants, could enhance the leachability of PCDDs/PCDFs, thus contributing to the vertical movement and leaching behavior of PCDDs/PCDFs in the landfill layers of the incineration residue. Moreover, it is highly probable that DCCs derive from the unburned carbon in the bottom ash mixed and buried with the fly ash containing a high content of PCDDs/PCDFs.  相似文献   

8.
Weber R 《Chemosphere》2007,67(9):S109-S117
One important criterion for assessment of a POPs destruction technology is the potential formation of new POPs and other toxic by-products, in particular whether the highly toxic PCDDs/PCDFs are formed and under which operation conditions their formation is relevant. For incineration processes the formation mechanisms of PCDDs/PCDFs have been investigated thoroughly and strategies and technologies were developed to minimize their formation and emission. A detailed assessment of non-combustion technologies with respect to PCDD/PCDF formation is, however, lacking to date. A comparison of reaction conditions for PCDD/PCDF formation from precursor formation studies and actual applied conditions of a broad range of POPs destruction technologies in the present paper indicates that the operation conditions for a number of destruction technologies have the potential to generate high concentrations of PCDDs/PCDFs if dioxin precursors are present and that also PCDD/PCDF de novo formation can take place. Therefore a strategy and regulations for a more profound assessment and monitoring of the fate of PCDD/PCDF formation and emission is essential for the evaluation of POP destruction technologies and for a sound risk management of POPs. The present paper aims to provide a critical impulse in this respect, discusses the relevant formation pathways with respect to POPs destruction technologies and proposes a basic framework on how evaluations may be performed.  相似文献   

9.
Combustion experiments in a laboratory-scale fluidized-bed reactor were conducted to elucidate the effects of copper chloride as a catalyst on polychlorinated dibenzo-p-dioxins (PCDDs) formation in municipal waste incineration. We used model wastes with and without copper chloride (CuCl2 · 2H2O), both of which contained polyvinyl chloride as a chlorine source. Combustion temperature was set to 900 °C, and the amount of air supplied was twice the stoichiometric ratio. The experimental setup was carefully planned to suppress the influences of experimental conditions except the waste composition. Results of these experiments showed that copper chloride in the waste increased the amount of PCDDs formed and made the homologue profile to shift towards the highly chlorinated species. Copper chloride contributes to the PCDDs formation by promoting chlorination, whereby the reaction is important in that organic matter is chlorinated directly by copper compounds. Copper chloride did not exert a great influence on the isomer distribution patterns of PCDDs, while there appeared a significant difference in the case of PCDFs. This points out the difference of the major formation mechanisms between PCDDs and PCDFs. PCDDs are less formed by the catalytic reactions from carbon/polycyclic aromatic hydrocarbons than PCDFs in our experimental conditions.  相似文献   

10.
Nakao T  Aozasa O  Ohta S  Miyata H 《Chemosphere》2002,46(3):429-437
Ash samples were collected from site of open-air incineration and fire concerning Hanshin Great Earthquake which occurred in western Japan in the early morning of 17 January 1995. The average concentrations of total sum of PCDDs, PCDFs and Co-PCBs in ash collected from wood scrap of broken building fire site, house fire site, shoe-making factory fire site and electric appliances store fire site were 541, 442, 859 and 22,800 pgTEQ/g, respectively. Particularly, PCDFs among dioxin analogs generated remarkably at sites with a high TEQ. In addition, 79,000 t of ash was totally produced at five open-air incineration sites, and consequently the formation amount of PCDDs, PCDFs and Co-PCBs was estimated to be 70.7 gTEQ on the basis of these analytical data.  相似文献   

11.
PCDDs and PCDFs in vehicle exhaust particles in Japan.   总被引:6,自引:0,他引:6  
Vehicle exhaust particles from gasoline and diesel engine cars were analyzed for PCDDs and PCDFs. The congener patterns of PCDDs and PCDFs in exhaust particles were different between gasoline and diesel engine cars. Suspended particulate matter from electrostatic precipitator connected to a highway tunnel was also analyzed for PCDDs and PCDFs. The congener pattern of suspended particular matter was different from both of gasoline and diesel engine cars. Total amounts of PCDDs/PCDFs sum concentrations in gasoline, diesel and suspended particulate matter were 0.21, 0.87 and 26.0 ng/g, respectively. The I-TEQs levels in gasoline, diesel and suspended particulate matter were 4.2, 11 and 242 pg/g, respectively.  相似文献   

12.
In an attempt to evaluate the background levels of PCDDs, PCDFs and non-ortho PCBs in people living in Madrid (Spain), blood serum samples had been analyzed PCDD, PCDF and coplanar PCB levels from non exposed individuals are reported in this study. Average levels found were 515.29 ppt for total PCDDs, 66.73 ppt for total PCDFs and 85.47 ppt for non-ortho PCBs on a lipid weight basis Calculated I-TEQ values were 8.78 ppt for PCDDs, 6.96 for PCDFs and 7.03 for coplanar PCBs on a lipid weight basis.  相似文献   

13.
Kim Y  Yang SH  Lee SY  Kim M 《Chemosphere》2001,43(4-7):851-855
We initiated an attempt to gather preliminary Korean fast food data on the concentrations, whole weight and international toxic equivalent (TEQ), in two kinds of fast foods, hamburger and fried chicken. The levels of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) in hamburgers are detected to be lower than in fried chickens. Total TEQ level of PCDDs in fried chicken is 47.45 times higher than in hamburger. In case of PCDFs, it is 48.61 times. Even though these are compared to the only one brand and three samples each, we think that these high levels of PCDDs/PCDFs in fried chicken are very important data because of the potentially increasing daily intake. If we continue to survey for PCDDs/PCDFs in fast foods more even, especially fried chicken, these data will be useful to calculate the estimated daily intake of TEQ levels of PCDDs/PCDFs in Korea.  相似文献   

14.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

15.
The catalytic effects of copper and iron compounds were examined for their behavior in promoting formation of chlorine (Cl2), the major chlorinating agent of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), in an environment simulating that of municipal waste fly ash. Formation of Cl2 occurred as a result of a metal-catalyzed reaction of HCl with O2. Catalytic activity was greatest at a temperature of approximately 400 °C, supporting a theory of de novo synthesis of PCDDs and PCDFs on fly ash particles downstream of waste combustion.  相似文献   

16.
Concentrations of 2,3,7,8-chlorine substituted PCDDs, PCDFs, selected PCB congeners and HCB were determined in sediment samples collected from sites along the east coast of Queensland in northern Australia. PCDDs were detectable in all sediment samples while PCDFs, PCBs and HCB were mainly found in sediment samples collected from sites in the Brisbane metropolitan area. The results provide evidence that an unidentified source for higher chlorinated PCDDs exists along the Queensland coast.  相似文献   

17.
A comprehensive air toxics measurements program designed to establish baseline concentrations of atmospheric polychlorinated dioxins and dibenzofurans (PCDDs/PCDFs) in the South Coast Air Basin has been completed. The program utilized state-of-the-art air sampling and laboratory analysis techniques (HRGC/HRMS) to quantify the fifteen 2,3,7,8-substituted PCDDs/PCDFs congeners of primary toxicological significance. This study, which included nine discrete sampling sessions between December 1987 and March 1989, provides the first systematic assessment of ambient PCDDs/PCDFs concentrations in the state of California. The highest PCDDs/PCDFs concentrations noted during this study occurred in December 1987. This period was dominated by off-shore air flows, suggesting a regional air mass and transport phenomena. Concentrations of the PCDDs/PCDFs were diminished markedly in subsequent sampling sessions where air flow patterns were primarily of on-shore or of coastal origin. Ambient PCDDs/PCDFs concentrations, expressed as toxic equivalents, were highest during the December 1987 sampling period. The El Toro monitoring site, located approximately 40 miles southeast of Los Angeles, consistently showed the lowest measured ambient PCDDs/PCDFs concentrations and toxic equivalents values. In the majority of the sessions and samples examined the PCDDs/PCDFs congener profiles strongly suggest combustion source influences. Typical of combustion source profiles, 1,2,3,4,6,7,8-HpCDD was the predominant 2,3,7,8-substituted species and most prevalent PCDD after OCDD. The congener of highest toxicological significance, 2,3,7,8-TCDD, was reported below the 10-20 fg/m3 detection limit for most of the ambient air samples selected for analysis.  相似文献   

18.
OBJECTIVE: The objective was to grasp the recent body burden levels of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DL-PCBs) and to investigate their determinants among general inhabitants in Japan. METHODS: This study was performed on 1374 participants aged 15-73 years, who were not occupational exposure to PCDDs/PCDFs and DL-PCBs, living widely in 75 different residential areas of 25 prefectures in Japan. Seven PCDDs, ten PCDFs, twelve DL-PCBs, which are assigned a toxicity equivalent factor, and biochemical factors were determined in fasting blood. A questionnaire survey on life-style was also performed. RESULTS: The median of total toxicity equivalent (TEQ) was 20pgTEQ/g lipid. The TEQs of PCDDs/PCDFs, DL-PCBs and total TEQ increased with age. The intake frequency of fish-and-shellfish was positively associated with the TEQ of DL-PCBs in both sexes. Current smoking was negatively related to the TEQ of DL-PCBs in male subjects but not in female subjects. Feeding status was significantly related to the TEQs of PCDDs/PCDFs, DL-PCBs and total TEQ, being lowest in breast feeding and highest in never and bottle feeding. According to the results of subgroup analysis, parity was not associated with the TEQs. CONCLUSIONS: The fish-and-shellfish consumption may contribute to the accumulation of DL-PCBs, and smoking may induce some biological action for the elimination of DL-PCBs from the human body. Breast feeding is considered to be one of the major excretory pathways of PCDDs/PCDFs and DL-PCBs in women, while parity may not largely contribute to the elimination of these pollutants.  相似文献   

19.
Kim M  O'Keefe PW 《Chemosphere》2000,41(6):793-800
Aqueous solutions of selected polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were prepared using a generator column and exposed to UV (300 nm) light in the laboratory and to sunlight in an outdoor environment. In the laboratory, additional exposures were also carried out using 60% acetonitrile/water solutions. At 300 nm di- and tetra PCDDs had higher first-order photodegradation rate constants in 60% acetonitrile/water than in pure water. The solvent effect was reversed for PCDFs. These results may be a reflection of the higher polarity of PCDFs compared to PCDDs. In both the indoor and outdoor exposures photodegradation rates decreased with increasing concentrations of chlorination. However, OCDF exposed to 300 nm light in 60% acetonitrile/water and to sunlight in pure water photodegraded more rapidly than tetra CDF. Photolysis rates in sunlight were considerably slower (t(1/2) of 6.4-23 h) than photolysis rates at 300 nm in the laboratory (t(1/2) of 4.3-680 min), reflecting the lower intensity of sunlight in the 300 nm region of the UV/Vis spectrum. The extent of dechlorination of the PCDDs/PCDFs was less than 20% and reductive dechlorination does not appear to be a major process in the photodegradation of PCDDs/PCDFs in aqueous solutions.  相似文献   

20.
PCDDs/PCDFs, dl-PCBs and HCB in the flue gas from coal fired CFB boilers   总被引:1,自引:0,他引:1  
The aim of the project was to measure the actual emissions of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and hexachlorobenzene (HCB) from four selected power plants in Poland in order to update the national inventory of PCDDs/PCDFs emission. Relatively low PCDDs/PCDFs as well as dl-PCBs concentrations in flue gas obtained in measurements in this study for four different circulated fluidized bed (CFB) boilers indicate practical absence of any hazards caused by PCDDs/PCDFs emission from these units. The results of PCDDs/PCDFs determination obtained in this study indicate that hard coal combustion in large CFB in the four central heating plants (CHP) is not a significant source of PCDDs/PCDFs emission to the environment even if operated by co-firing of waste coal. PCDDs/PCDFs concentration in flue gases as well as emission factors were recorded in the range of 0.012-0.060ngI-TEQ/m(n)(3) and 7.51-46.4mugI-TEQ/TJ, respectively. Dl-PCBs concentration was practically below the LOQ=0.006ng WHO-PCB TEQ/m(n)(3) in all experiments. HCB concentration as well as emission factors were recorded in the range of 11.5-42.0ng/m(n)(3) and 6.19-26.7mg/TJ, respectively, where the highest value was obtained for co-firing of waste coal, however. Obtained in this work emission factors will be used for national emission inventory purposes instead of the factors proposed by Toolkit or taken from previous measurements. However, consideration should be given to the fact that the measurements in most cases are related to single installations. Therefore, the need for further development of national factors for the power generation industry in Poland is desired.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号