首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Growth of white oak (Quercus alba L.) trees was examined, using tree-ring analysis, at three sites near a small, remote coal-fired power plant in central Pennsylvania, USA. Forests immediately adjacent to the power plant have been subjected to power plant emissions since the power plant initiated operation in 1954. However, localized, ground-level fumigations have been gradually reduced over the years due to a series of construction projects resulting in increased stack heights. Comparisons of growth were made among the white oaks growing at the three close-in sites, as well to the growth of white oak at three control sites located 10-50 km from the power plant, during periods of differing stack heights. White oak exhibited reduced growth at two of the close-in sites during the time period when historical ground-level air pollution exposures were assumed to be greatest due to low stack heights. White oak growth at the third close-in site was not substantially reduced during this time period. In 1976, taller stacks were implemented at the power plant to reduce local, ground-level concentrations of air pollutants. The recovery of tree growth at the two close-in affected sites, and increased synchronous growth responses from 1976-85 among all three close-in sites, indicates that implementation of taller stacks in 1976 reduced ground-level pollutant levels to such dosages that growth was not impaired at any site. Also, growth rates after 1976 were comparable to the growth rates of the white oaks growing on the control sites. A possible interacting factor was a severe drought that occurred in the mid-1960s in central Pennsylvania.  相似文献   

2.
The power plant designer today has the tools at hand which enable him to predict with an adequate degree of accuracy the effect of different stack heights on ground level concentrations of the gaseous pollutants emitted from power plant stacks. Use of tall stacks will make it possible in most cases to build larger power plants at any particular site than are in service now and still operate them satisfactorily from the standpoint of air pollution. On the other hand, atmospheric pollution considerations may make it necessary at some sites to put a finite limitation on the maximum capacity that can be installed.  相似文献   

3.
This paper presents a technique to study air pollution by combining high spatial resolution data obtained by a mobile platform and those measured by conventional stationary stations. Conventional stations provide time-series point data but cannot yield information that is distant from the sites. This can be complemented or supplemented by mobile measurements in the vicinity of the conventional sites. Together, the combined dataset yields a clearer and more precise picture of the dispersion and the transformation of pollutants in the atmosphere in a fixed time frame. Several experiments were conducted in the years 2002-2003 to track the impact of power plant plumes on ground receptors in the immediate vicinity (within a radius of 30 km) of the plants, using a combined mobile and stationary dataset. The mobile data allowed the identification of emissions from coal-fired and gas-fired power plants. Coal-fired power plants were the major source of sulfur dioxide (SO2), whereas nitrogen oxides (NOx) emitted from the gas-fired power plant played an important role in the formation of ozone (O3) at ground level. The mobile data showed that two particle size distribution regimes were detected: one had a dominant accumulation mode at 0.40-0.65 microm and the other at 0.65-1 microm. The existence of particles characterized by their mode at 0.65-1 microm and formed by in-cloud processes suggests that vehicular emissions were not the important source. Other local sources, such as power plants (elevated emission), were the likely sources, because Hong Kong does not have much manufacturing industry.  相似文献   

4.
Effect of air pollution on peri-urban agriculture: a case study   总被引:10,自引:0,他引:10  
Peri-urban agriculture is vital for the urban populations of many developing countries. Increases in both industrialization and urbanization, and associated air pollution threaten urban food production and its quality. Six hour mean concentrations were monitored for SO(2), NO(2) and O(3) and plant responses were measured in terms of physiological characteristics, pigment, biomass and yield. Parameter reductions in mung bean (Vigna radiata), palak (Beta vulgaris), wheat (Triticum aestivum) and mustard (Brassica compestris) grown within the urban fringes of Varanasi, India correlated directly with the gaseous pollutants levels. The magnitude of response involved all three gaseous pollutants at peri-urban sites; O(3) had more influence at a rural site. The study concluded that air pollution in Varanasi could negatively influence crop yield.  相似文献   

5.
The lichen Canomaculina pilosa was transplanted to 21 sampling sites, plus two controls sites in a north-western area of Córdoba City, Argentina. The transplantation sites were set according to traffic levels, industry condition and distances from the power plant. On the transplanted lichens chlorophyll a, chlorophyll b, phaeophytin a, soluble proteins, hydroperoxy-conjugated dienes, malondialdehyde concentration and sulphur accumulation were determined. A pollution index was calculated for each sampling site. The present study provides information about chemical parameters showing variations as the response of C. pilosa to different emission sources of air pollutants. The C. pilosa chemical response was mainly associated to industries. Significant higher values were observed in phaeophytin a/chlorophyll a ratio, sulphur content and pollution index values in lichen material transplanted at sites with industry. For the distance from the power plant category, only the hydroperoxy-conjugated dienes concentration showed significant differences. For the different traffic levels no significant variations were observed for any of the chemical parameters quantified.  相似文献   

6.
The lichen Punctelia subrudecta (Nyl.) Krog was transplanted to 22 biomonitoring sites in a northwestern area of Córdoba city, Argentina and tested for chlorophyll a, chlorophyll b, phaeophytin a, soluble protein, hydroperoxy conjugated dienes (HPCD), malondialdehyde (MDA) concentration and sulphur accumulation. A pollution index (PI) was calculated for each biomonitoring site. The biomonitoring sites were set according to (1) traffic levels, (2) industrial density and (3) distance of the power station close to each site. The biomonitor's chemical response was associated with industries as well as power stations. Significant differences were observed in sulphur content, MDA concentration and PI values in lichen material transplanted to sites with different industrial densities. The higher values for these parameters were found at sites with high industrial levels. At the same time, significant differences were detected for sulphur content in samples at different distances from the power station, with higher accumulation in samples located far from the power plant. For MDA concentration, effect of different levels of industrial density was observed only at points close to the power station, probably because of higher levels of humidity near the power plant. For PI significantly higher values were observed in samples at points far from the power station and with high industrial density. This shows the additive effect of the principal emission sources that act on the response of P. subrudecta to air pollutants.  相似文献   

7.
The aim of the study was determination of air pollution impact of the copper smelter in Bor and its surroundings (Serbia) by assessing the suitability of birch (Betula pendula Roth.) and spruce (Picea abies L.) for the purposes of biomonitoring and comparing it with previously published data from the same study area. The concentrations of Cu, Zn, Pb and Mn in leaves/needles, branches, roots and soil were determined. Sampling was performed during 2009 in two zones with high load of air pollution due to copper mining and smelting activities, and one background zone. Metal accumulation and translocation was evaluated in terms of biological factors. In addition, plant enrichment factor was calculated. According to the results, plant foliage was not enriched through soil, which indicates absorption from the air, with both species acting as excluders of Cu, Pb, Zn and Mn. Leaves were more enriched with all the metals than needles, indicating a better response of birch to airborne pollution than spruce. Cluster analysis showed different level of pollution at the sites, while correlations between Cu and Pb obtained by Principal Component Analysis indicated their anthropogenic origin. Regarding previously published results, beside birch leaves, pine needles (which showed higher level of response to pollution compared to linden leaves) could be applied in air biomonitoring surveys near copper smelters.  相似文献   

8.
The optimum level of sulfur pollution control for a coal fired power plant is the point where the sum of societal costs, due to pollution, and control costs is minimized. This basic microeconomic concept has been of limited practical value due to considerable uncertainty in estimating both costs. A probabilistic approach is used to characterize these uncertainties quantitatively for a hypothetical 1000 Mwe plant located near Pittsburgh, Pennsylvania. Only mortality effects within a distance of 80 km of the plant have been included. The results allow explicit consideration of attitude toward risk and appropriate level of investment to prevent deaths. Limitations of the findings are discussed. Implications are described for policy based on alternative sets of values and assumptions.  相似文献   

9.
Understorey vegetation of Scots pine forests was studied along a 8-km transect running SE from a Cu-Ni smelter at Harjavalta, SW Finland. Long-term accumulation of heavy metals and sulphur in the forest ecosystem has drastically changed plant communities. Vegetation was almost absent up to a distance of 0.5 km from the smelter. The total coverage and the number of plant species increased with increasing distance from the smelter. Ordination by global non-metric multidimensional scaling (GNMDS) indicated that the floristic composition was differentiated in response to the pollution level. The main compositional gradient of GNMDS was correlated with the heavy metal concentrations in the organic soil layer and with the size of the overstorey trees. Vascular plants were more pollution-resistant than ground lichens, whereas mosses were the most sensitive plant group. In addition to heavy metals, nutrient imbalances and the considerably reduced water-holding capacity of the surface soil also restrict plant recolonisation on the degraded sites.  相似文献   

10.
In this paper, we present an adaptation of the air pollution control help system in the neighborhood of a power plant in As Pontes (A Coru?a, Spain), property of Endesa Generación S.A., to the European Council Directive 1999/30/CE. This system contains a statistic prediction made half an hour before the measurement, and it helps the staff in the power plant prevent air quality level episodes. The prediction is made using neural network models. This prediction is compared with one made by a semiparametric model.  相似文献   

11.
Open pollinated families of loblolly pine differing in resistance to fusiform rust disease were screened in laboratory studies for responses to gaseous air pollutants. Twenty families were given acute exposures (2 fumigations for 4 h each) to SO(2) (0.4-1.0 ppm), O(3) (0.25 ppm), SO(2) (0.4-1.0 ppm) + O(3) (0.25 ppm) and control. Analyses of variance were performed to evaluate the treatment effects of these air pollutants on percent foliar injury, and to determine whether the families responded differentially to the air pollution treatments. Treatment effects were significant, with the combination treatment of SO(2) + O(3) producing a higher percentage of foliar injury than the controls; however, injury levels were very low and may not be of biological significance. Subsequently, twelve families were grown in two soil types for exposure to chronic levels of SO(2) (0.06 ppm), O(3) (0.07 ppm), SO(2) (0.06 ppm) + O(3) (0.07 ppm) and control. The families were then ranked for decreased primary shoot growth, shoot dry weight, root dry weight, total plant dry weight and root/shoot ratio after exposure to air pollution treatments. Air pollution treatments as a main effect were significant for only one of five growth parameters measured, that of primary shoot growth. The main effect of family, and the interaction of family and air pollution treatments, were significant for most growth parameters measured. In general, O(3) alone and in combination with SO(2) reduced growth more than SO(2) alone. Fumigation with O(3) reduced growth of two families in comparison with control groups, whereas SO(2) alone produced decreased growth in one family and stimulated growth in three families. Treatment with O(3) alone produced higher root/shoot ratios than fumigation with charcoal-filtered air in two families. Overall, families which were fast growers under control conditions maintained their ranking after exposure to air pollution. Families producing less growth in charcoal-filtered air also produced less growth under various air pollution regimes. Results indicated that these families exhibited a high degree of resistance to air pollution injury. Growth responses of seedlings may not reflect family differences in long-term productivity. No relationship was apparent between fusiform rust resistance and growth reductions due to air pollutants.  相似文献   

12.
This paper describes a comprehensive set of economic models developed to assess the air pollution control costs of alternative systems for generating electricity from coal. Models of individual system components were formulated based on engineering and statistical analyses of other detailed models and data reported in the literature for currently available technologies. The air pollution control options modeled include 4 levels of physical coal cleaning, 3 types of dry fly ash collectors, a wet limestone FGD system, and 2 options for solid waste disposal. In addition, the cost of a power plant with no air pollution controls was modeled to determine the total system cost, including energy needed to operate environmental control systems. The principal criteria guiding the development of these models were that they be (1) computationally simple and economical to use, with a minimum of detailed data requirements, (2) sensitive to variations in pollutant emission regulations, coal characteristics, and key plant design parameters, and (3) systematic, based on a specified amount of power production and the same constant dollars. Extensive sensitivity analyses and case studies performed with these models indicate excellent agreement with the results of other studies and models applicable only to individual environmental control options. Applications of these models are discussed and illustrative results presented.  相似文献   

13.
A series of experiments was carried out in controlled environment cabinets to investigate the effects of SO(2) dose on the mean relative growth rate (MRGR) of pea aphids, Acyrthosiphon pisum, feeding on the pea plant, Pisum sativum. There was a significant linear increase in the MRGR of aphids feeding on SO(2)-fumigated plants, relative to control aphids feeding on plants in charcoal-filtered air. The increase in MRGR reached a maximum of 11% at SO(2) concentrations between 90 and 110 nl litre(-1). MRGR declined at higher SO(2) concentrations until above 220 nl litre(-1) it was below that of the controls. The dose-response curve is discussed in relation to reported changes in the nitrogen metabolism of plants subject to air pollution, the response of aphids to host plant nitrogen and possible toxic effects of high concentrations of SO(2) on the aphid.  相似文献   

14.
The types and rates of pollutant emissions from a coal-fired power plant depend upon plant design, coal characteristics, and environmental control policy. In the past, air pollution regulations were often promulgated without rigorous analysis of the resulting energy penalties and secondary environmental impacts that occur in other environmental media (air, land, or water), which are counterproductive to overall environmental quality. This paper describes a Comparative Assessment Model that has been developed to consider systematically such tradeoffs for conventional and advanced coal-to-electric technologies. The model is applied to quantify the secondary (“cross-media”) environmental and resource impacts resulting from alternative air pollution control policies that reduce sulfur dioxide emissions from a 1000 MW power plant. Multimedia pollutant burdens are presented, together with the increased requirements for coal, limestone, and water that are incurred in generating a fixed net quantity of electricity. The development of sound public policy requires that environmental regulations be sensitive to adverse effects in all environmental media, and that tradeoffs involved in the regulation of specific pollutants to one medium be rigorously and systematically characterized.  相似文献   

15.
Abstract

About half of the world's population now lives in urban areas because of the opportunity for a better quality of life. Many of these urban centers are expanding rapidly, leading to the growth of megacities, which are often defined as metropolitan areas with populations exceeding 10 million inhabitants. These concentrations of people and activity are exerting increasing stress on the natural environment, with impacts at urban, regional and global levels. In recent decades, air pollution has become one of the most important problems of megacities. Initially, the main air pollutants of concern were sulfur compounds, which were generated mostly by burning coal. Today, photochemical smog—induced primarily from traffic, but also from industrial activities, power generation, and solvents—has become the main source of concern for air quality, while sulfur is still a major problem in many cities of the developing world. Air pollution has serious impacts on public health, causes urban and regional haze, and has the potential to contribute significantly to global climate change. Yet, with appropriate planning megacities can efficiently address their air quality problems through measures such as application of new emission control technologies and development of mass transit systems.

This review is focused on nine urban centers, chosen as case studies to assess air quality from distinct perspectives: from cities in the industrialized nations to cities in the developing world. This review considers not only megacities, but also urban centers with somewhat smaller populations, for while each city—its problems, resources, and outlook—is unique, the need for a holistic approach to complex environmental problems is the same. There is no single strategy to reduce air pollution in megacities; a mix of policy measures will be needed to improve air quality. Experience shows that strong political will coupled with public dialogue is essential to effectively implement the regulations required to address air quality.  相似文献   

16.
Bone fluoride in short-tailed voles (Microtus agrestis) and common shrews (Sorex araneus), the prey of barn owls (Tyto alba), was studied on Anglesey, North Wales. The average fluoride content of M. agrestis skulls obtained from a location 0.9 km from an aluminium reduction plant was significantly greater than that of skulls from another location 22 km from the source of industrial fluoride pollution. At both locations, mean fluoride levels of skulls extracted from owl pellets and those of voles trapped mechanically were broadly similar but important differences existed. Near the aluminium reduction plant, owls caught voles and shrews with a much wider range of fluoride levels than occurred at a single trapping site. However, there was no evidence for selection of heavily fluoridated prey. Within 1 km of the aluminium reduction plant, six trapping sites yielded S. araneus with a fourfold difference between the highest and lowest mean bone fluoride level.  相似文献   

17.
The suitability of a set of ecophysiological parameters, to be used as early warning indicator to detect signs of a worsening environment around geothermal power plants, was tested by comparison with the diversity of epiphytic lichens, a well-established indicator of geothermal air pollution. Samples of the lichen Evernia prunastri were transplanted around a geothermal power plant at Larderello (Tuscany, Italy) and at a control site, and integrity of cell membranes, concentration of chlorophyll a, b and carotenoids, chlorophyll integrity and variations in pH of thalli were measured. The results showed that cell membrane damage, expressed by changes in electrical conductivity, could be used to detect early (exposure periods as short as 1 month) deleterious effects of geothermal air pollution.  相似文献   

18.
Although post-combustion emissions from power plants are a major source of air pollution, they contain excess CO2 that could be used to fertilize commercial greenhouses and stimulate plant growth. We addressed the combined effects of ultrahigh [CO2] and acidic pollutants in flue gas on the growth of Alternanthera philoxeroides. When acidic pollutants were excluded, the biomass yield of A. philoxeroides saturated near 2000 μmol mol−1 [CO2] with doubled biomass accumulation relative to the ambient control. The growth enhancement was maintained at 5000 μmol mol−1 [CO2], but declined when [CO2] rose above 1%, in association with a strong photosynthetic inhibition. Although acidic components (SO2 and NO2) significantly offset the CO2 enhancement, the aboveground yield increased considerably when the concentration of pollutants was moderate (200 times dilution). Our results indicate that using excess CO2 from the power plant emissions to optimize growth in commercial green house could be viable.  相似文献   

19.
The results of forest health status assessments in the Carpathian Mountains from the monitoring networks developed by the European Union Scheme on the Protection of Forest Against Atmospheric Pollution (EU Scheme) and International Co-operative Programme on Assessment and Monitoring of Air Pollution Effects on Forests (ICP-Forests), have led to a better understanding of the impact of air pollution and other stressors on forests at the regional scale. During the period 1997-2001, forests in the Carpathian Mountains were severely affected by air pollution and natural stresses with 29.7-34.9% of the trees included in defoliation classes 2-4. The broadleaves were slightly healthier than the conifers, and European beech (Fagus sylvatica) was the least affected species. Norway spruce (Picea abies) has poor health status, with 42.9-46.6% of the trees damaged (2-4% defoliation classes). Silver fir (Abies alba) damage was also high, with 46.0-50.9% in defoliation classes 2-4. Pines (primarily Pinus sylvestris) were the least affected of the conifers, with 24.9-33.8% in defoliation classes 2-4. The results from the transnational networks (16 x 16 km) show that the Carpathian forests are slightly more damaged than the average for the entire Europe. The correlative studies performed in individual European countries show the relationships between air pollution stressors with trends in defoliation and a possible effect of natural stresses at each site. More specific, effects of tree age, drought, ozone and acid deposition critical level exceedances were demonstrated to affect crown condition.  相似文献   

20.
With rising concentrations of both atmospheric carbon dioxide (CO2) and tropospheric ozone (O3), it is important to better understand the interacting effects of these two trace gases on plant physiology affecting land-atmosphere gas exchange. We investigated the effect of growth under elevated CO2 and O3, singly and in combination, on the primary short-term stomatal response to CO2 concentration in paper birch at the Aspen FACE experiment. Leaves from trees grown in elevated CO2 and/or O3 exhibited weaker short-term responses of stomatal conductance to both an increase and a decrease in CO2 concentration from current ambient level. The impairement of the stomatal CO2 response by O3 most likely developed progressively over the growing season as assessed by sap flux measurements. Our results suggest that expectations of plant water-savings and reduced stomatal air pollution uptake under rising atmospheric CO2 may not hold for northern hardwood forests under concurrently rising tropospheric O3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号