首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Aerobic biological treatment, such as the activated sludge process, is commonly used for municipal wastewater treatment. Fine-pore diffusers have virtually replaced coarse-bubble diffusers in such operations, but most of the plant's energy expenditure is still consumed by aeration. Therefore, the performance of diffusers will critically affect plant economics. This paper analyzes and quantifies the consequences of aging processes on fine-pore diffusers. Datasets from 94 field measurements were analyzed and showed a clear pattern of performance decline with time in operation. Efficiency declines rapidly during the first 24 months of operation when the rate of decline decreases and efficiency stabilizes at a low value. For example, cost analysis scenarios were performed using the measured rate of decline in diffuser performance. The analyses include loss of transfer efficiency and elevated headloss, which both increase operating cost. Cleaning the diffusers within 12 months of operation is generally economically favorable, restores efficiency, and reduces power overhead. Periodic cleaning prolongs the economically viable lifespan for the aeration system.  相似文献   

2.
Fine-pore diffusers, often called fine-bubble diffusers, have nearly replaced coarse bubble diffusers in municipal wastewater treatment over the past 20 years. The rapid increases in energy costs, which began in the 1970s, created financial incentives to upgrade to this more expensive and maintenance-intensive method of aeration. Fine-pore diffusers have the added benefit of reducing volatile organic compound stripping and reduced aeration heat loss. This paper summarizes 15 years of oxygen transfer efficiency measurements using the offgas technique. Efficiencies are shown for different types of diffusers at various tank geometries (depth, diffuser size, and number), airflow rates, and mean cell retention times (MCRT or sludge age). By normalizing the airflow rates per unit of depth and diffusing area, efficiencies measured in different plants can be compared. The results show that aeration efficiencies are logarithmically related to the ratio between MCRT and the normalized air flux, with transfer rates suppressed by low MCRT or high normalized air flux systems. There is no evidence for different alpha factors among the different types of fine-bubble diffuser types.  相似文献   

3.
Models that predict volatilization of organic compounds from wastewater treatment basins may underestimate emission rates if the surfaces are considered as quiescent. In reality, the water surface may be agitated by subsurface aeration, increasing mass transfer across the tank surface air-water interface. This study investigated the effect of turbulence, induced by diffused bubble aeration, on mass transfer at the water surface of a pilot aeration basin. The mass transfer of ammonia from an enclosed headspace over the basin to acidified water was measured when different diffuser types and airflow rates were applied. Oxygen-transfer tests were conducted immediately following each ammonia-transfer test. Increasing airflow rates through fine- and coarse-bubble diffusers had a significant effect on the ammonia mass-transfer rate. Experimental mass-transfer parameters (K(L)a's) for surface volatilization derived with aeration present were up to 48% higher than the K(L)a values for quiescent conditions over the range of conditions tested. No effect of diffuser type on ammonia transfer could be determined. The study results infer an effect on oxygen transfer into the water at the surface and potential transfer of volatile organic compounds, if present, from the water. The results of the ammonia mass-transfer experiments suggest that adjustments to the existing mass transfer correlations for surface volatilization from aeration basins may be in order. Such adjustments will have the greatest effect on predictions for the less volatile compounds, under conditions of low airflow rates.  相似文献   

4.
焦化废水生物处理尾水的活性炭吸附及条件优化研究   总被引:6,自引:0,他引:6  
国内焦化企业废水生物处理尾水中COD、色度等指标超标的现象大多是由残留的难降解有机物造成的。针对这种现象,通过采用不同种类和孔结构的活性炭、改变炭表面化学性质、优化吸附环境3种方式对生物处理尾水中的COD成分进行强化吸附,考察炭型、表面化学性质及pH值等因素的影响,以明确焦化废水吸附法深度处理的合理炭型及其优化的条件。把已稳定运行的1 320 m3/d处理规模焦化废水A/O/H/O工艺实际工程生物处理尾水作为研究对象,试验了13种活性炭品种的吸附去除COD及色度的效果,发现甲基蓝值和丹宁酸值大的炭型其吸附容量高;而某一种炭样的吸附特性实验中,不同化学改性时表面酸性官能团含量少的活性炭有利于提高其吸附容量,低pH值条件的吸附能力高于碱性条件,曝气混合方式能够缩短吸附平衡时间。经过优选的活性炭在适宜的反应条件下能够将焦化废水生物处理尾水中的COD值及色度值分别降低至60 mg/L及20倍以下,在较低的运行费用条件下使出水达到工业循环冷却水的水质要求。  相似文献   

5.
A combined system comprised of a cloth media filter and a membrane microfilter operated in series was used to treat secondary effluent. The study objective was to investigate the effect of premembrane filtration on the maximum sustainable membrane flux, transmembrane pressure, and effluent quality. The maximum sustainable time-averaged flux under predefined operating conditions (i.e., 15-minute process cycle, 24-hour chemical cleaning cycle, and 30-day intensive cleaning cycle) was 127 L/m(2)x h. Typical flux rates for secondary effluent ranged from 40 to 55 L/m(2) x h. Effluent water quality from the combined system was high and independent of membrane flux and influent quality. Average membrane effluent water quality values were 0.04 NTU for turbidity and 1.4 mg/L for 5-day biochemical oxygen demand. Neither total nor fecal coliforms were detected. Based on the results presented herein, prefiltration would provide an annualized cost savings of approximately 12% over microfiltration alone for a 3.8 x 10(3) m(3)/d treatment facility.  相似文献   

6.
低曝气下PAC强化SBR工艺同步脱氮除磷   总被引:1,自引:0,他引:1  
采用序批式反应器(SBR)处理模拟生活污水,研究不同曝气量(30、24、18和12 L/h)下活性污泥同步脱氮除磷规律,并在最佳曝气量下,比较了粉末活性炭-序批式反应器(PAC-SBR)和SBR的脱氮除磷效率,分析了低曝气下PAC-SBR的运行特性和优越性。实验结果表明,当曝气量为24 L/h时,SBR内出水效果较好,其COD、TN和TP的平均去除率分别可以达到90.02%、81.13%和88.12%。在这个最佳曝气量下,PAC-SBR具有明显的优势,其COD、TN和TP的平均去除率均高于SBR,并且PAC-SBR具有较好的污泥沉降性能和较高的活性污泥浓度。在PAC-SBR中,活性污泥以PAC作为微生物载体强化了生物降解效果,并改善了低曝气下污泥絮体的结构,促使反应器内先后形成缺氧-厌氧-微氧/缺氧-缺氧的环境,利于同步硝化反硝化和反硝化聚磷,提高了PAC-SBR的同步脱氮除磷效率。  相似文献   

7.
Simultaneous nitrification and denitrification (SND or SNdN) may occur at low dissolved oxygen concentrations. In this study, bench-scale (approximately 6 L) bioreactors treating a continuous feed of synthetic wastewater were used to evaluate the effects of solids retention time and low dissolved oxygen concentration, under cyclic aeration, on the removal of organics, nitrogen, and phosphorus. The cyclic aeration was carried out with repeated cycles of 1 hour at a higher dissolved oxygen concentration (HDO) and 30 minutes at a lower (or zero) dissolved oxygen concentration (LDO). Compared with aeration at constant dissolved oxygen concentrations, the cyclic aeration, when operated with proper combinations of HDO and LDO, produced better-settling sludge and more complete nitrogen and phosphorus removal. For nitrogen removal, the advantage resulted from the more readily available nitrate and nitrite (generated by nitrification during the HDO period) for denitrification (during the LDO period). For phosphorus removal, the advantage of cyclic aeration came from the development of a higher population of polyphosphate-accumulating organisms, as indicated by the higher phosphorus contents in the sludge solids of the cyclically aerated systems. Nitrite shunt was also observed to occur in the LDO systems. Higher ratios of nitrite to nitrate were found in the systems of lower HDO (and, to less dependency, higher LDO), suggesting that the nitrite shunt took place mainly because of the disrupted nitrification at lower HDO. The study results indicated that the HDO used should be kept reasonably high (approximately 0.8 mg/L) or the HDO period prolonged, to promote adequate nitrification, and the LDO kept low (< or =0.2 mg/L), to achieve more complete denitrification and higher phosphorus removal. The above findings in the laboratory systems find strong support from the results obtained in full-scale plant implementation. Two plant case studies using the cyclic low-dissolved-oxygen aeration for creating and maintaining SND are also presented.  相似文献   

8.
This study compared results of no aeration, intermittent aeration, and constant aeration strategies in determining the static acute (48-h) toxicity of phenolic-based effluents to adult fathead minnows (Pimephales promelas). Toxicity was greatest in no aeration tests followed by intermittent aeration and constant aeration. Two factors were considered responsible for the observed patterns of toxicity. First, in side-by-side tests of no versus intermittent aeration and intermittent versus constant aeration, toxicity reductions were directly attributed to maintenance of dissolved oxygen above 5.0 mg litre(-1) in aerated containers. Secondly, toxicity was reduced when treatment system temperatures were warmest, probably due to increased microbial activity and volatilisation during late spring to early autumn (temperatures > 16 degrees C). Effluent was slightly more toxic on- than off-site, presumably due to degradation of phenolic compounds during transport and set-up at the off-site laboratory (approximately 4.5 h). Gill tissue ultrastructure and histopathology were used to determine the extent of effluent-induced damage and the recovery of minnows to short (6-h) effluent exposures. After a 48-h exposure to the approximate LC(50) level, gill tissue lamellae were characteristically desquamated with epithelium lifting from the basement membrane. Gill tissue was similarly damaged after a 6-h exposure to 100% effluent and had recovered to pre-exposure conditions after 42 h in clean water. Aeration strategies in these studies demonstrated potential air-stripping of volatile compounds, although stress to test organisms from low dissolved oxygen was relieved.  相似文献   

9.
为了研究非稳定状态下生物除磷的特点,采用序批式间歇反应器(SBR),通过不同的进水方式(连续进水和瞬时进水),系统地考察了进水体积、NOX-N、限制曝气等因素对除磷过程的影响。结果表明,在温度为(23±0.5)℃、pH为7.0~8.0时,厌氧搅拌期连续进水的比释磷量(单位质量污泥(以MLSS计)的释磷量(以PO43-P计))比瞬时进水时高出42.11%。在运行条件相似的情况下,厌氧搅拌期的比释磷量与每周期进水体积无关。相对于连续进水,瞬时进水更有助于促进微生物利用有机底物进行自身的生长。限制曝气对连续进水和瞬时进水的释磷过程都存在明显的影响,在DO小于0.1mg/L的情况下,2者的比释磷量相对非限制曝气时分别降低了57.14%和55.56%。在连续进水时,NOX-N的反硝化结束伴随着释磷速率的突然升高。利用贮存作用并不能每次都成功地抑制丝状菌污泥膨胀。  相似文献   

10.
竹制填料生物接触氧化工艺处理污染河水   总被引:1,自引:0,他引:1  
针对受污染的湖溪河水质特征,以传统弹性塑料填料做对比,研究以竹球和竹丝为填料的生物接触氧化工艺,考察填料的挂膜时间、生物量和污水处理效果;确定连续曝气和间歇曝气时反应器的最优运行工况:连续曝气时为HRT:7.5h,DO=3mg/L;间歇曝气时为厌氧1.2h、好氧6.3h交替运行。实验结果表明,与弹性塑料填料相比,竹制填料挂膜速度快,竹球填料的水处理效果最好;连续曝气最优工况下竹球填料反应器中COD、TN、NH3-N和TP的平均去除率分别为66.7%、47.9%、57.1%和30.6%;间歇曝气最优工况下竹球填料反应器中COD、TN、NH3-N和TP的平均去除率分别64.08%、39.95%、60.7%和54.68%;竹制填料可替代传统的塑料填料作为生物接触氧化工艺的载体填料。  相似文献   

11.
根据环氧丙烷废水的特点,应用电化学法处理具有较高的可行性。运用电化学法处理PO废水前必须进行废水预处理,用以提高电流效率和延长极板寿命。采用曝气和化学絮凝结合的方法去除PO废水中的Ca2+,同时去除部分COD。对曝气、无机絮凝剂(PACl、PFS)和有机絮凝剂(PAM)对PO废水处理过程中的曝气量、曝气时间、投药量、复配和沉降时间等主要影响因子进行了实验研究,通过比较Ca2+、COD的去除效果、絮凝剂用量、沉降时间、处理成本等方面,在设定的实验参数下得到最佳预处理方案为:曝气量为2.5 L/min,曝气45 min,投加Na2CO3粉末24 kg/t 废水,充分混匀后加入PFS+PAM复配絮凝剂。本方案具有废水处理效果好(Ca2+的去除率为77.03%,COD的去除率为37.46%)、投药量少((100+7.5)g/t废水)、沉降时间短(5 min)、处理成本低(0.675元/t废水)等优点。通过对比经预处理和不经预处理后电化学法对COD去除效果、电流和处理后阴极表面,验证了预处理方案的必要性与可行性。  相似文献   

12.
The objective of this paper is to compare the following four methods of measuring oxygen transfer in wastewater treatment plants under process conditions: the offgas, hydrogen peroxide (H2O2), reaeration, and in situ oxygen uptake rate (OUR) methods. Comparative tests were performed under controlled conditions in a pilot column and in six full-scale oxidation ditches equipped with fine-bubble diffusers and slow-speed mixers. The offgas and H2O2 methods give similar results (differences between the oxygen-transfer coefficients under field conditions [k(L)a(f)] from each method lower than 10%). The reaeration procedure gives more random results (differences from -5 to -43% compared with values obtained using the offgas method). The in situ OUR method, in the presence of a horizontal flow of mixed liquor, leads to an estimate of k(L)a(f) to within 15% of the offgas value.  相似文献   

13.
竹制填料生物接触氧化工艺处理污染河水   总被引:1,自引:0,他引:1  
针对受污染的湖溪河水质特征,以传统弹性塑料填料做对比,研究以竹球和竹丝为填料的生物接触氧化工艺,考察填料的挂膜时间、生物量和污水处理效果;确定连续曝气和间歇曝气时反应器的最优运行工况:连续曝气时为HRT=7.5 h,DO=3 mg/L;间歇曝气时为厌氧1.2 h、好氧6.3 h交替运行。实验结果表明,与弹性塑料填料相比,竹制填料挂膜速度快,竹球填料的水处理效果最好;连续曝气最优工况下竹球填料反应器中COD、TN、NH3-N和TP的平均去除率分别为66.7%、47.9%、57.1%和30.6%;间歇曝气最优工况下竹球填料反应器中COD、TN、NH3-N和TP的平均去除率分别64.08%、39.95%、60.7%和54.68%;竹制填料可替代传统的塑料填料作为生物接触氧化工艺的载体填料。  相似文献   

14.
Membrane fouling is linked to reversible or irreversible accumulation of macromolecules and solids on membrane surfaces and to the irreversible adsorption inside pores. If reversible accumulation can be controlled by filtering in subcritical conditions, then adsorption could also be minimized by reducing the soluble organic matter [extracellular polymeric substances, soluble microbial products (SMP)]. This research shows how the choice of operating parameters related to biological reaction (solid retention time and the organic loading rate) can influence the process rate and the by-product (SMP) production. It also illustrates how suspension characteristics and membrane aeration can influence membrane fouling control according to the hollow fiber configuration and to the different scales of observation. The investigations were based on the definition of different fouling level and fine-tuning of a model to better understand the effects of operating parameters on membrane bioreactor filtration.  相似文献   

15.
研究了微曝气Fenton氧化法关键工艺参数对模拟双酚A(BPA)废水处理效果的影响,并从活性污泥性质和污染物去除率两方面,采用膜生物反应器(membrane bioreactor, MBR)对微曝气Fenton氧化法的处理效果进行了实验验证,为实现BPA废水的生物处理奠定基础。结果表明,初始pH值、反应时间、H2O2/COD(质量浓度比)、H2O2/Fe2+ (摩尔浓度比)、反应温度及曝气量均对预处理效果有较大影响,在最佳条件下,COD去除率可达70%,BOD/COD值则由原废水的0.02提高到0.50以上。MBR处理上述出水的结果表明,经微曝气Fenton氧化处理BPA的废水,可较好地适应后续的生化处理。  相似文献   

16.
对纳米SiO2改性聚偏氟乙烯(SiO2/PVDF)离子交换膜电渗析处理单组分电解质溶液进行了试验研究。结果表明,在不同操作条件下,SiO2/PVDF离子交换膜的极限电流密度和脱盐率均大于未改性聚偏氟乙烯(PVDF)离子交换膜。SiO2/PVDF离子交换膜的极限电流密度随着淡水流量和电解质浓度的增加而增加;随着电流强度的增加,SiO2/PVDF离子交换膜的脱盐率也相应增加;随着淡水流量增加,脱盐率会逐渐降低。为使SiO2/PVDF离子交换膜用于电渗析过程获得良好的脱盐效果和节约能量,NaCl质量浓度为500mg/L时电流密度应控制在1.17mA/cm2。  相似文献   

17.
以一体式尼龙筛网动态膜生物反应器(DMBR)为研究体系,与好氧颗粒污泥相结合,形成新的好氧颗粒污泥动态膜生物反应器(AGDMBR),探讨了在新工艺条件下对COD、氨氮的去除,以及出水浊度的变化,与活性污泥动态膜生物反应器(DMBR)做比较,研究了进水流量、曝气量等工艺运行参数与膜污染之间的关系,并对系统中污泥的EPS进行分析。结论表明,AGDMBR系统对COD和NH4+-N的平均去除率分别为91%和95%,出水浊度为6 NTU,处理效果均优于DMBR系统;AGDMBR系统在运行过程中膜污染速度随进水流量的增大而加快;曝气量为125~150 L/h时,膜通量持续时间最长;AGDMBR系统比DMBR系统在膜污染的延缓上具有明显的优势。  相似文献   

18.
微气泡曝气中氧传质特性研究   总被引:18,自引:0,他引:18  
气泡曝气过程中氧传质对于好氧生物处理过程具有重要意义。采用水力旋转剪切微气泡发生装置,考察了运行条件和水质特性对微气泡曝气中氧传质特性的影响。结果表明,微气泡曝气可获得较高的气含率和气泡停留时间;表面活性剂十二烷基磺酸钠(SDS)可以提高微气泡曝气的气含率和气泡停留时间。微气泡曝气中氧的总体积传质系数明显高于传统气泡曝气。总体积传质系数随着空气流量的增加而增加;氧传质效率随着空气流量的增加而减小,且对空气流量的变化更为敏感。在温度15~35℃范围内,微气泡曝气中氧的总体积传质系数随着温度的增加而增加,变化关系与传统气泡曝气基本相同,但对温度的变化更为敏感。微气泡曝气中,表面活性剂SDS会使氧的总体积传质系数略有降低,其不利影响明显小于传统气泡曝气;氧的总体积传质系数随盐度(NaC l浓度)增加而逐渐增加,并在NaC l浓度5 000 mg/L后趋于稳定。  相似文献   

19.
The removal of particulate material in the aeration basin of the activated sludge process is mainly attributed to bioflocculation and hydrolysis of particulate substrate. The bioflocculation process in the aeration tank of the activated sludge process occurs only under favorable conditions in the system, and several common operational parameters affect its performance. The principal objective of this research was to observe the effect of mixed liquor suspended solids, solids retention time (SRT), and extracellular polymer substances on the removal of particulate substrate by bioflocculation. A first-order particulate removal expression, based on flocculation, accurately described the removal rates for supernatant suspended solids and colloidal chemical oxygen demand. Based on the results presented in this investigation, a mixed liquor concentration of approximately 2200 mg/L, an SRT of at least 3 days, and a contact time of 30 minutes are needed for relatively complete removal of the particulate substrate in a plug-flow reactor.  相似文献   

20.
把pH值在线监测与药品自动投加系统与已开发的混合呼吸测量仪集成,组成自动呼吸-滴定测量仪,同时测得废水生物处理过程溶解氧(DO)、pH、氧气利用速率(OUR)和质子变化速率(HVR)。分别监测了只投加NH4+-N底物的活性污泥硝化过程和实验室脱氮除碳SBR曝气阶段的DO/pH响应,结果显示,两信号呈一定规律变化,在反应...  相似文献   