首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

2.
Xu MX  Yan JH  Lu SY  Li XD  Chen T  Ni MJ  Dai HF  Cen KF 《Chemosphere》2008,71(6):1144-1155
Isomer-specific data were investigated in order to identify the sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in agricultural soils, including Fluvo-aquic and paddy soils, in the vicinity of a Chinese municipal solid waste incineration (MSWI) plant. Homologue and isomer profiles of PCDD/Fs in soils were compared with those of potential sources, including combustion sources, i.e., MSWI flue gas and fly ash; and the impurities in agrochemicals, such as the pentachlorophenol (PCP), sodium pentachlorophenate (PCP-Na) and 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP). The results showed that the PCDD/F isomer profiles of combustion sources and agricultural soils were very similar, especially for PCDFs, although their homologue profiles varied, indicating that all the isomers within each homologue behave identically in the air and soil. Moreover, factor analysis of the isomer compositions among 33 soil samples revealed that the contamination of PCDD/Fs in agricultural soils near the MSWI plant were primarily influenced by the combustion sources, followed by the PCP/PCP-Na and CNP sources. This implication is consistent with our previous findings based on chemometric analysis of homologue profiles of soil and flue gas samples, and identifies PCP/PCP-Na as an additional important source of PCDD/Fs in the local area. This makes the similarities and differences of isomer profiles between Fluvo-aquic and paddy soils more explainable. It is, therefore, advisable to use isomer-specific data for PCDD/F source identifications where possible.  相似文献   

3.
This study shows the catalyzing effects of iron and copper on the formation of chlorinated compounds such as chlorobenzenes (ClBzs), chlorophenols (CIPhs), polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Both total concentrations and congener distributions have been studied. The parameters and conditions varied during the combustion tests were the complete and incomplete combustion and the metal and chlorine addition. The incomplete combustion promoted the formation of organic chlorinated compounds in flue gas particles. Highly chlorinated congeners of PCDD/F were dominant in the flue gas particles, whereas the importance of lower chlorinated congener were increased in the gas phase. In the complete combustion conditions the concentrations of PCDD/Fs increased when the degree of chlorination were high, nevertheless the concentrations of tetra and penta PCDD/Fs were higher in the gas phase than the concentrations in the fly ash particles. Organic chlorine promoted the formation of chlorinated compounds more effectively than inorganic chlorine, which instead promoted the formation of PCDD/Fs in the gas phase, especially with copper catalyst. Different concentration levels of chlorinated compounds were observed in the gas phase and in particles when the chlorine source and combustion conditions were varied from incomplete to optimum conditions. Both copper and iron seem to have a catalytic effect on PCDD/F formation.  相似文献   

4.
Control of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in emissions and thermal residues from incinerators has been a cause of public concern for more than one decade. Recently, several studies showed that other persistent organic pollutants (POPs) such as coplanar polychlorinated biphenyls (co-PCBs) also have dioxin-like activity and are released from incinerators. Therefore, the present study was aimed at making a risk assessment about dioxin-like activity in extracts of thermal waste residues (e.g. combustion gas; fly ash, slag) from incineration and melting processes in Germany and Japan. For this purpose, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), coplanar polychlorinated biphenyls (co-PCBs), polychlorinated naphthalenes (PCNs) and polyaromatic hydrocarbons (PAHs) were analyzed by chemical analysis. Additionally, 2, 3, 7, 8-TCDD equivalents (EROD-TEQs) were determined by in vitro Micro-EROD bioassay using rat H4IIE hepatoma cells. EROD-TEQs could be correlated to I-TEQ values (from PCDD/Fs/co-PCBs) analyzed by chemical analysis resulting in a maximal sixfold higher estimate. Our study indicates minor influences of co-PCBs, PAHs and PCNs to the sum of dioxin-like toxicity in the extracts of thermal waste residues as determined here. Furthermore, we showed that the levels of dioxins and co-PCBs contained in slag from melting processes and bottom ashes from incineration processes were lower by 1-2 orders of magnitude than that in fly ash.  相似文献   

5.
Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers' findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/ Fs, also needs to be carefully reconsidered.  相似文献   

6.
Urea as a PCDD/F inhibitor in municipal waste incineration   总被引:2,自引:0,他引:2  
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at approximately 730 degrees C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

7.
ABSTRACT

Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at ~730 °C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

8.
Abstract

Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers’ findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/Fs, also needs to be carefully reconsidered.  相似文献   

9.
The authors previously proposed the concept of a new thermal remediation process for particulate/powder materials contaminated by polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and experimentally verified its validity on the basis of process efficiency. However, contaminees such as soils and fly ashes from waste incinerators often contain a considerable amount of other chlorides, which may act as a main source of chlorine in the formation of PCDD/Fs via thermal processes. The present study aims to examine the formation and transport of PCDD/Fs in the packed bed of soil containing a chloride during the process. Polyvinyl chloride (PVC) polymer was mixed with soil sample as an organic chloride model. A laboratory-scale apparatus was employed as a process simulator. Further, a technique to quench the process was applied to observe the concentration distribution of PCDD/Fs in the solid bed in the vertical direction. The result shows that the PCDFs tend to form dominantly in the high temperature (calcination and/or combustion) zone and are successively trapped in the low temperature (wet) zone. Especially, TeCDF is the most dominant homologue contained in the wet zone and outlet gas. Although PCDD/Fs are once trapped at the wet zone, the concentration of the remediated materials gives fairly low value (1.9 pg/g-dry, 0.04 pg-TEQ/g-dry). It signifies that organic chlorides mingled in the solid contaminee not affect the removal efficiency of PCDD/Fs in the process. Nevertheless, attention should be paid to the potential emission of PCDD/Fs in the outlet gas due to the presence of organic chloride in the soil.  相似文献   

10.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

11.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

12.
Kim KS  Hong KH  Ko YH  Yoon KD  Kim MG 《Chemosphere》2003,53(6):601-607
Emission characteristics of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in diesel engine were studied with variable load rate of the diesel engine with the emission test cycles, US D-13 mode. The load rate is changed from 25% to 50% and 75% at constant speed of 2400 rpm. PCDD/Fs concentration and phase distribution of PCDD/Fs with the isokinetic sampling of exhaust gas is obtained in this study. The average PCDD/Fs concentrations per unit of exhaust gas with 25%, 50% and 75% load rate are 14.5, 6.9 and 6.4 pg-TEQ/N m3, respectively. In all diesel engine runs, PCDFs are more prevalent than PCDDs. As a load rate is increased, the ratio of PCDDs is gradually decreased. The amount of high-chlorinated PCDDs emitted in diesel engine is larger than that of low-chlorinated PCDDs. The significant emission form of PCDD/Fs produced from diesel engines exhaust is a gas phase.  相似文献   

13.
Wang D  Xu X  Zheng M  Chiu CH 《Chemosphere》2002,48(8):857-863
The influences of temperature, air flow and the amount of copper chloride upon the types and amount of the toxic emissions such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs) during combustion of polyvinyl chloride (PVC) were investigated. The mechanism concerning the effect of temperature and copper chloride on the PCDD/Fs and PAHs formation was discussed. The results shown that without copper chloride, trace amounts of PCDD/Fs and large amounts of PAHs were found in the emissions from the pure PVC combustion under various combustion conditions. The addition of copper chloride enhanced PCDD/Fs formation, but it seems that the formation of PAHs decreased with increasing amount of copper chloride, and greater total amount of PAHs were produced at the higher temperature under our experimental conditions.  相似文献   

14.
Emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) from municipal waste incineration are currently a subject of considerable public concern because of their extreme toxicity. PCDD/F formation in incineration processes is being studied widely, but little work has been done on their inhibition. We studied the effect of two liquid inhibitors, sodium ammonium hydrogen phosphate (NAHF) and urea (H2NCONH2), on PCDD/F formation in the combustion of liquid fuel doped with copper and chlorine using a pilot-scale plant. The inhibitors were injected into the flue gas stream at a temperature of 725 degrees C, whereupon both the chlorophenol and PCDD/F concentrations decreased. Particle-phase PCDD/F concentrations in particular decreased by up to 90% with NAHF and 70% with urea, but gas phase reduction took place only with urea. The results suggest that the formation of PCDD/Fs is hindered in the particle phase at the early stages of the PCDD/F formation chain, probably even before precursors such as chlorophenols have been formed. As a consequence, particle-phase PCDD/F concentrations can be predicted by a PLS (partial least-squares) approach with the gas-phase chlorophenol concentrations as independent variables. The structure and partial charges of Cu(+)-urea complex were calculated by the HF/3-21G basis set.  相似文献   

15.
Wu HL  Lu SY  Yan JH  Li XD  Chen T 《Chemosphere》2011,84(3):361-367
The fly ash used in this study was collected from a bag filter in a medical waste rotary kiln incineration system, using lime and activated carbon injection followed by their collection as mixed fly ash. Experiments were conducted on fly ash in a quartz tube, heated in a laboratory-scale horizontal tube furnace, in order to study the effect of temperature and nitrogen flow rate on the removal of PCDD/Fs. Results indicated that in this study PCDD/Fs in the fly ash mostly were removed and desorbed very little into the flue gas under thermal treatment especially when the heating temperature was higher than 350 °C, and dechlorination and destruction reactions took important part in the removal of PCDD/Fs. However, in terms of flow rate, when flow rate was higher than 4 cm s−1, destruction efficiency of PCDD/Fs decreased dramatically and the main contributors were P5CDF, H6CDF and H7CDF desorbed to flue gas, the PCDD/Fs in the fly ash decreased with enhanced flow rate.  相似文献   

16.
One option of recycling used contaminated packaging is to recover its high energy content. This can be performed in a normal multi-fuel power plant by co-combustion of packaging-derived fuel (PDF) or refuse-derived fuel (RDF) with fossil fuels, such as coal or peat. This work includes the results of 17 co-combustion tests and an evaluation of the results by the Principal Component Analysis (PCA) and the Partial Least Squares Projections to Latent Structures (PLS). PCA and PLS calculations showed that especially Pb, but also Cr, and Cu correlated with lower chlorinated furans (PCDFs) in the fly ash. Correlation between Sn and lower chlorinated dioxins (PCDDs) in the fly ash was also noticed. CO and PAH emission in the flue gas correlated with total PCDD/Fs in the flue gas. In a real full-scale combustion process, a single parameter in fuel, flue gas or a combustion parameter did not provide a guide to PCDD/F formation or to a level of the total PCDD/F emission, but correlations between different parameters and PCDD/Fs could be found. Although PDFs and RDF had catalytic heavy metals and chlorine, the co-combustion results showed that they can be co-combusted with peat and coal in a fluidized-bed boiler at least up to 26 % with very low total PCDD and PCDF emissions.  相似文献   

17.
Nakao T  Aozasa O  Ohta S  Miyata H 《Chemosphere》2006,62(3):459-468
We investigated combustion in a small home waste incinerator and analyzed both flue gas and residual ash for formation of the dioxin-related compounds polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and coplanar polychlorinated biphenyls and their precursors polychlorinated benzenes, polychlorinated phenols, polychlorinated diphenyl ethers, and polychlorinated biphenyls. Particularly, we investigated the effect of the incinerated material's composition on both the congener ratios of released compounds and the total concentration of all congeners of each compound. Eight different samples were prepared for incineration with four samples consist entirely paper, dead leaves, natural wood, or building materials. The remaining four samples contained mostly paper, but also other components such as fiber, non-chlorine-containing plastics, chlorine-containing plastics, and copper electric wire. The presence of non-chlorine-containing plastic in combustion samples did not increase overall dioxin or dioxin-precursor emissions. In contrast, chlorine-containing plastic resulted in a several-fold increase in total polychlorinated dioxins released, in both flue gas and residual ash. Copper wire resulted in a further several-fold increase in total polychlorinated dioxins and dioxin precursors released, with one exception: the addition of chlorine-containing plastic resulted in a many-fold increase in polychlorinated biphenyls, but only a modest further increase ( approximately 52%) with the further addition of copper. Homologue ratios tended toward higher-chlorine compounds as chlorine-containing plastic and Cu were added, but the results were far from uniform. Our results show that toxic dioxin release from small home waste incinerators must be considered significant, especially if even small amounts of chlorine-containing plastics or copper are burned.  相似文献   

18.
Spruce (Picea abies (L.) Karst.) needles were exposed to exhaust gas containing polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) generated by combustion of polyvinyl chloride, wood, high-density polyethylene, and styrene. Photodegradation of PCDD/Fs adsorbed on spruce needles under sunlight irradiation was studied. The photodegradation of PCDD/Fs follows pseudo-first-order reaction kinetics, with photolysis half-lives ranging between 40 and 100 h. The photolysis rates of PCDF congeners are higher than PCDD congeners with the same chlorinated substitutions. Higher chlorinated PCDD/Fs tend to photolyze slowly. The wax components in spruce needles may act as proton donors and accelerate the photolysis rate. C-Cl cleavage through the addition of protons to PCDD/F molecules may be an important route for PCDD/Fs photodegradation.  相似文献   

19.
Formation and destruction of PCDD/F inside a grate furnace   总被引:1,自引:0,他引:1  
Hunsinger H  Jay K  Vehlow J 《Chemosphere》2002,46(9-10):1263-1272
Formation and destruction of polychlorinated dibenzo-p-dioxins and dibenzofurans PCDD/F during the combustion process was investigated experimentally in a pilot plant. All important process steps like the burnout of the fuel bed on the grate, the burnout of the flue gas inside the combustion chamber, the heat recovery in a boiler as well as influences of the fuel composition are described in detail.

High concentrations especially of PCDF are formed during the burnout of the fuel bed. The formation reaction is mainly influenced by the fuel composition and the burnout characteristic of the fuel bed. Fuels with low chlorine and low metal content (Cu) result only in negligible concentrations of PCDD/F.

Under stable combustion conditions characterized by an excellent flue gas burnout PCDD/F will almost be completely destroyed already inside the combustion chamber. “Cold strands” of unburned flue gas (high CO concentrations) caused by disturbed combustion conditions will result in high concentrations of PCDD and especially of PCDF in the raw gas.

A second place of PCDD/F formation is the well-known boiler section. Here fly ash deposits containing residual carbon (mainly soot particles) are the source for the formation reaction. Under stationary effective combustion conditions, they are dominant for PCDD/F concentrations in the raw gas over a very long period of time.

Stationary efficient flue gas burnout (especially soot) together with effective boiler cleaning will guaranty low concentrations of PCDD/F in the flue gas in front of the flue gas cleaning system.  相似文献   


20.
Bottom ash that was the result of the combustion of chromated copper arsenate (CCA) treated wood under controlled fire conditions showed an increase of several orders of magnitude in the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), compared to that of untreated timber. Wood that has been pressure treated with CCA contains copper (II), which is known to catalyse the so-called de novo formation of PCDD/Fs. Comparable levels of PCDD/Fs would be expected in residual ash from burning CCA-treated wood in backyard fires, stoves and wood heaters, as a consequence of similar combustion conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号