1.
采用固相萃取-超高效液相色谱-串联质谱法(UPLC-MS/MS)通过对固相萃取柱、洗脱液、流动相等的优化,建立了水中16种芳氧苯氧丙酸酯类(APP)除草剂的分析方法。确定以Oasis HLB为固相萃取柱、丙酮-正己烷(1∶1,V/V)为淋洗液、水-乙腈(3∶7,V/V)为流动相进行水样预处理,在最优条件下,各目标物在水中的回收率均达到74.5%~124.9%,相对标准偏差为4.2%~9.6%,线性范围为1~2 000μg/L,各目标物标准品在UPLCMS/MS系统中有效的线性相关系数(R2)达到0.998以上。该方法具有检测限低、回收率高等优点,经实际样品测试,可适用于水中16种APP类除草剂的同时检测。  相似文献   

2.
建立了索氏提取-固相萃取-液相色谱法测定土壤中环境优先监测的6种酚类污染物监测方法。利用索氏提取和固相萃取法提取净化了土壤中6种酚类化合物,比较5种固相萃取柱萃取的效果,选择PSD固相萃取柱,优化了固相萃取条件,影响固相萃取回收率的4种因子显著性顺序为:水样p H上样速度洗脱液体积溶剂类型。最佳固相萃取条件:上样的水样p H=3,上样速度5 m L/min,洗脱溶剂为乙腈,洗脱溶剂体积是10.0 m L。酚类化合物的检出限为0.01~0.05 mg/kg,加标回收率在85.39%~105.82%之间,相对标准偏差RSD10%(n=7),该法操作方便,灵敏度高,可用于土壤中多种酚类化合物的测定。  相似文献   

3.
比较了液液萃取和固相萃取两种方法对左炔诺孕酮的萃取效果,为含左炔诺孕酮水样分析预处理提供参考.运用高效液相色谱法检测了二氯甲烷、三氯甲烷、正己烷、乙酸乙酯4种有机溶剂和StrataTM-X(60 mg,3mL)固相萃取柱对左炔诺孕酮的萃取回收率;萃取回收率分别为:乙酸乙酯(97.22%)>二氯甲烷(91.89%)>正己...  相似文献   

4.
建立了以固相萃取(SPE)、气相色谱-三重四级杆串联质谱法(GC/MS/MS)测定地表水中16种有机磷农药(organophosphorus pesticides,OPPs)残留的方法。用Bond Elut C18和Oasis HLB固相萃取柱净化富集水样,优化色谱和质谱条件参数,在多反应监测模式下进行定性、定量分析。结果表明,该方法可以有效富集16种OPPs,回收率在46.1%~117.2%之间,相对标准偏差(RSD)在1.1%~15.8%之间;检出限范围为0.09~0.82 ng/L,结果准确可靠,具有极高的灵敏度和准确度,满足地表水水质监测的需要,尤其在痕量分析中具有更广泛的应用。  相似文献   

5.
通过改进硅烷化方法,比较不同洗脱溶剂、洗脱体积和富集前水样pH值对萃取效果的影响,建立固相萃取-硅烷化-气相色谱方法,用于水中壬酸和焦酚含量的同时测定。根据标准物质的保留时间,实现壬酸和焦酚混合物的定性分析;根据特征峰面积实现壬酸和焦酚的定量分析。结果表明:采用Oasis HLB固相萃取小柱(10 mg,1 m L)富集样品,1 mL丙酮洗脱,丙酮和BSTFA等量配比硅烷化,可实现水中壬酸和焦酚同步快速检测,回收率高于80%。该方法可用于脂肪酸、酚酸类化感物质环境行为动态研究,为水生植物化感作用研究提供技术支撑。  相似文献   

6.
活性炭纤维萃取浓缩水样中微量有机磷农药   总被引:1,自引:1,他引:0  
采用活性炭纤维(ACF)为固相萃取剂填料,萃取测定水样中微量有机磷农药。研究分析了ACF用量、洗脱剂类型、农药初始质量浓度、水样过柱速度及pH等因素对萃取回收率的影响。结果表明:洗脱剂类型和ACF用量是显著的影响因素。最佳萃取条件为:含0 1μg L有机磷农药的1L加标水样,需0 2gACF和8mL二氯甲烷,水样过柱速度40mL min。pH对萃取影响不大。萃取回收率为80 7%~118%。   相似文献   

7.
采用自动固相萃取-气相色谱/质谱技术,建立了地表水中痕量多环芳烃和有机氯农药的检测方法。调节水样pH2,加入1%甲醇,使用C18固相萃取柱富集,3 mL丙酮+3 mL二氯甲烷洗脱后浓缩定容。采用气相色谱/质谱联用的全扫描模式进行分析,选择特征离子定量,方法检出限为0.026~8.772 ng/L。加标水平为0.1μg/L时,样品加标回收率在74.8%~109%之间,RSD为0.01%~14.5%。该方法自动化程度高、快速、准确、重复性好,能满足地表水体中持久性有机污染物分析的要求。  相似文献   

8.
建立了固相萃取(SPE)-超高效液相色谱/大气压化学电离源/三重四极杆串联质谱(UPLC-MS/MS)同时测定水中7种苯甲酰脲类杀虫剂残留的方法。过滤后的样品经HLB固相萃取柱富集净化后,目标化合物经10 mL二氯甲烷洗脱并浓缩,1 mL甲醇定容后,采用BEH C18柱,以水(5 mmol/L乙酸铵)-乙腈作为流动相进行梯度洗脱,采用串联质谱作为检测器进行检测。7种苯甲酰脲类杀虫剂在相关线性范围内线性良好(r=0.999 1~0.999 5),回收率为71.8%~114%,相对标准偏差为3.3%~18.8%,方法检出限为7.0~16.0 ng/L。该方法快速,灵敏度高,适用于测定水体中7种苯甲酰脲类杀虫剂的残留。  相似文献   

9.
研究了固相膜萃取对地表水中有机氯农药(OCPs)物质的提取效果,并与液液提取法(LLE)进行比较.建立了固相膜萃取/气相色谱法检测地表水中20种有机氯农药的方法.结果表明:当萃取膜为HLB膜,洗脱液溶剂为丙酮和正己烷,萃取效果最理想,20种OCPs的回收率稳定在74.1%~94.3%之间,固相膜萃取法与传统液液提取法相比,既提高了萃取效率同时又减少了有机萃取溶剂的用量.该法检测实际样品时,同时加入2种内标指示剂对方法的性能进行了验证,2种内标示踪剂的回收率分别为71.6%~94.8%和69.9%~109.5%,样品中20种OCPs均未检出.  相似文献   

10.
建立了利用固相萃取-高分离度快速液相色谱-串联质谱(SPE-RRLC-MS/MS)测定制药废水中青霉素G残留的方法。水样以30%硫酸锌+20%亚铁氰化钾作为沉淀剂沉淀蛋白质后,上清液采用Oasis HLB固相萃取柱富集和净化,以0.01 mol/L乙酸铵溶液(加0.1%甲酸)+乙腈作为流动相进行等度洗脱,经Agilent Plus C18柱分离后,在串联质谱ESI(+)源下进行MRM检测。该方法的青霉素G检出限(S/N=3)为0.02μg/L,目标物在0.0020~1.0 mg/L范围内线性关系良好,线性相关系数为0.9997。在0.20,1.0,2.0μg/L添加水平平均回收率为74.6%~101.4%,相对标准偏差为4.49%~8.17%。该方法灵敏度高、重现性好、定性定量准确,可满足制药废水中青霉素G残留检测的要求。  相似文献   

11.
为评价北京市城市河流地表水体中5种精神活性物质〔METH(甲基苯丙胺)、AMP(苯丙胺)、KET(氯胺酮)、EPH(麻黄碱)和HA(羟亚胺)〕的环境风险,通过对固相萃取柱(Oasis HLB、Oasis MCX、Oasis WAX和Oasis PRiME HLB)类型、水样酸化、洗脱剂类型及体积等条件的确定,建立了同时测定水环境中精神活性物质的固相萃取-液相色谱-质谱(SPE-LC-MS/MS)联用方法,并对北京市城市河流地表水体中5种精神活性物质的质量浓度水平进行了调查,采用RQ(风险熵)法进行了风险评价. 结果表明,在水样未酸化条件下,Oasis MCX柱对精神活性物质的回收率最高,使用含5%(V/V)氨水的甲醇作为洗脱液,5种精神活性物质的回收率可以达到81.8%~91.1%. 地表水水体基质加标结果表明,5种精神活性物质的加标回收率均大于75.5%,相对标准偏差均小于10.0%. 方法检出限为0.30~0.80 ng/L,定量限为1.00~2.68 ng/L. 北京市7条城市河流中5种精神活性物质的质量浓度在1.00~99.51 ng/L之间. EPH在所有采样点均被检出且质量浓度较高,ρ(EPH)平均值为22.79 ng/L;ρ(AMP)相对较低,在1.54~11.23 ng/L之间,但AMP检出率为97.06%;ρ(METH)较高,平均值为14.63 ng/L,最高值(99.51 ng/L)出现在坝河. 研究显示,北京市地表水中5种精神活性物质的RQ均小于0.1,表明其可能的环境风险较低,但由于精神活性物质本身具有生物活性,它们对城市河流水生生态系统产生的潜在危害不容忽视.   相似文献   

12.
A method to extract algae toxin of microcystin-LR   总被引:3,自引:0,他引:3  
A simple and low-cost method to obtain cyanobacterial toxin microcystin-LR(MC-LR) was developed. A new strain of Microcystis aeruginosa,named DC-1, producing microcystin-LR but not microcystin-RR, was separated from the field blooming algae samples of Dianchi Lake.in southwest of China. Following three times‘freeze and thaw treatment, the cultivated DC-cells were extracted with 40% methanol in water.The extract was centrifuged and the supernatant applied to a Hydrophilic-Lipophilic Balance(HLB) SPE cartridge.Eluted impuries with a certain gradient from 30% to 50% methanol in water, MC-LR was finally eluted from the HLB cartridge with 60%.may be used in adsorption and biodegradation experiments instead of using expensive standard reagents.  相似文献   

13.
A simple, rapid, and reproducible method is described employing solid-phase extraction (SPE) using dichloromethane followed by gas chromatography (GC) with flame ionization detection (FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15cm depth of water. Two-hundred ml of n-hexane-pretreated and filtered water samples were applied directly to a C18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0. 104 to 0.372 μg/ml. The highest concentration of benzene was found as 0.372 μg/ml with a relative standard deviation (RSD) of 6.2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceedina 90% could be achieved for cumene at 4℃ with a 2.7% RSD.  相似文献   

14.
基于固相萃取(SPE)和气相色谱/质谱联用技术(GC-MS),建立了一种焦化废水中痕量苯并(a)芘(BaP)的定量分析方法。BaP水样添加甲醇改性后经SPE富集净化、二氯甲烷洗脱、氮吹浓缩、二氯甲烷或乙腈定容后采用GC-MS进行定量分析。结果表明:在优化的样品前处理和分析条件下,BaP标准曲线的线性相关系数R2>0.99,方法回收率为79.6%~85.5%,方法检出限和定量限分别为4.33 ng/L和14.45 ng/L。该方法应用于内蒙古某焦化厂二级生化出水加标样品中BaP的测定,得到BaP的回收率为83.3%~89.3%,表明其灵敏度高、选择性好,适用于焦化废水中痕量BaP的定量检测。  相似文献   

15.
固相萃取技术及其研究进展   总被引:21,自引:0,他引:21  
马娜  陈玲  熊飞 《上海环境科学》2002,21(3):181-184
对固相萃取技术的原理和特点,萃取参数(吸附剂用量、背景体积及洗脱溶剂等)与萃取效率的规律,吸附剂的研究进展与发展趋势,以及目前的固相萃取在线联用技术等方面进行了阐述。该技术比传统液—液萃取用时短、二次污染小、选择性好,是一种很有前途的样品预处理技术。已广泛应用于环境样品中多环芳烃、农药、卤代烃、有机氯化合物、酚类等优先控制污染物的测定。  相似文献   

16.
文章确立了小麦、香蕉中戊唑醇残留检测方法,小麦样品加水10 mL用丙酮为萃取溶剂,石油醚液液分配,中性氧化铝柱层析净化,用气相色谱(GC-NPD)检测。香蕉样品加水5 mL用丙酮为萃取溶剂,石油醚液液分配,浓缩后用气相色谱(GC-NPD)检测。分别设置不同时间批次,同一批次间的平行样及实验室内人员分析,分别从方法灵敏度、方法准确度、方法精密度及其质量控制图、标准工作液的稳定性来探讨该方法的可靠性,结果表明该方法可以作为香蕉和小麦种戊唑醇残留检测的标准分析方法。  相似文献   

17.
氟喹诺酮类抗生素(FQs)作为常见的药品和个人护理用品(PPCPs)在环境中广泛存在.由于在生物体内很难被代谢,FQs会通过粪尿排泄等途径进入城市污水处理系统并最终富集到污泥中.并且,由于其在环境中的累积效应,FQs的存在极易增强致病菌的耐药性,限制了污泥的后续资源化利用.为得到适用于污泥中FQs的分析方法,进一步把握FQs在污水及污泥处理过程中的固/液分配及降解规律,研究中选择4种代表性FQs:氧氟沙星(OFL)、诺氟沙星(NOR)、环丙沙星(CIP)和洛美沙星(LOM)为研究对象,并通过所设计的正交试验,考察了固相萃取材料、萃取体系p H、洗脱剂对FQs的固相萃取效率的影响,在此基础上进一步优化了固相样品中FQs的提取方法,最终建立了细胞破碎,碱式提取(三乙胺/甲醇/水以5/25/75混合),固相萃取富集(SPE),磷酸-三乙胺溶液为缓冲盐流动相,甲醇为有机流动相,梯度荧光扫描的高效液相色谱-荧光(HPLCFLD)检测方法.液态样品中4种FQs的加标回收率采用新方法后可达到82%~103%;固态样品中4种FQs的加标回收率也可达到71%~101%.同时,为进一步确认不同运行条件对污泥吸附FQs能力的影响,针对好氧、缺氧和厌氧污泥分别进行了吸附试验研究,发现处于不同活性状态的污泥(厌氧、缺氧和好氧污泥)对FQs的吸附能力呈现出递减的趋势,但对FQs的吸附率都达到90%以上.该结论也证实了实际污水处理厂所去除的50%的FQs主要是通过污泥吸附这一途径实现的.  相似文献   

18.
为测定水节霉发生地河水中ρ(SVOCs)(SVOCs为半挥发性有机物),比较了LLE(液液萃取)和SPE(固相萃取)前处理法提取加标空白水样中ρ(SVOCs)的GC-MS/SIM测定结果,确定并采用重现性好的SPE-GC-MS/SIM法测定了水节霉发生地河水中的ρ(SVOCs). 结果表明,LLE和SPE法对SVOCs的加标回收率分别为41.8%~121.5%和31.5%~124.4%,相对标准偏差分别为6.0%~18.0%和0.9%~14.5%,二者回收率相差不大,但SPE法的相对标准偏差小于LLE法,SPE法重现性较好,因此采用SPE-GC-MS/SIM法测定2011年2月水节霉发生地河水中的ρ(SVOCs),共检出29种SVOCs,其中ρ(邻苯二甲酸二乙酯)、ρ(∑PAHs)、ρ(硝基苯)、ρ(1,2-二氯苯)和ρ(1,4-二氯苯)分别为1 020.59、532.14、43.39、38.52和19.57 ng/L,均未超出GB 5749—2006《生活饮用水卫生标准》相关限值,表明水节霉发生地未发生SVOCs污染.   相似文献   