首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 551 毫秒
1.
The dispersion of 222Rn from emitted waste gases at Wairakei geothermal power station, New Zealand, is modelled. It is concluded that resulting concentrations in the nearby township of Taupo will never exceed the maximum permissible in any meteorological situation. The greatest possible accumulation is calculated to be less than one eighth of the normal background radon concentration. A more realistic set of assumptions predicts long-term mean concentrations about 4% of background levels. A new geothermal power station, Ohaaki, a factor of three times more distant, is calculated to produce ten times lower concentrations than Wairakei. Measurements using a few passive solid-state radon detectors show that the natural variation of radon concentrations greatly exceeds any calculated contribution from either geothermal station; hence, much of the radon is probably due to more local minor sources. Local sources have increased due to draw-off of ground water by the Wairakei station. Thus, there could be some indirect contribution to radon concentrations by its operation. The measured six-month integrated mean radon concentration at Taupo is a significant fraction of the maximum permissible concentration. It seems likely that natural sources alone may lead to levels in air which are above the maximum when temperature inversion exists. It is concluded that these two geothermal power plants are unlikely to produce concentrations of radon hazardous to the population or to plant workers.  相似文献   

2.
The seasonal variation of 222Rn concentrations in the air of tunnels constructed during World War II at Nagano City has been investigated. The determination of 222Rn concentrations in tunnel air was performed using a solid-state nuclear track detector technique. The monthly radon concentrations changed smoothly, decreasing towards winter and increasing towards summer, and it was found that the concentrations strongly correlate with the temperature difference between the inside and the outside of the tunnel. In the innermost areas of the tunnel, the maximum concentration was observed in July, its value being about 6500 Bq m (-3). The concentrations of radon in the tunnel air decrease exponentially towards the openings of the tunnel, which indicates that the radon concentration in the tunnel is basically governed by diffusion and mixing of radon gas with air. These observations lead to the conclusion that the seasonal variation of the radon concentration in the tunnel air is mainly caused by a convection current due to a stack effect induced by the temperature difference between the tunnel air and the outside air.  相似文献   

3.
The seasonal variation of 222Rn concentrations in the air of tunnels constructed during World War II at Nagano City has been investigated. The determination of 222Rn concentrations in tunnel air was performed using a solid-state nuclear track detector technique. The monthly radon concentrations changed smoothly, decreasing towards winter and increasing towards summer, and it was found that the concentrations strongly correlate with the temperature difference between the inside and the outside of the tunnel. In the innermost areas of the tunnel, the maximum concentration was observed in July, its value being about 6500 Bq m (-3). The concentrations of radon in the tunnel air decrease exponentially towards the openings of the tunnel, which indicates that the radon concentration in the tunnel is basically governed by diffusion and mixing of radon gas with air. These observations lead to the conclusion that the seasonal variation of the radon concentration in the tunnel air is mainly caused by a convection current due to a stack effect induced by the temperature difference between the tunnel air and the outside air.  相似文献   

4.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

5.
The concentrations of 222Rn (radon) and its progeny with surrounding environmental gamma-dose rates were measured simultaneously inside and outside of buildings at 10 locations around Taipei and Hualien in Taiwan. For summer radon in Taiwan, indoor concentrations were estimated to be about 20 Bq m(-3) with about 90 nSv h- of environmental gamma, and outdoors, about 10 Bq m(-3) with about 70 nSv h(-1). The equilibrium factors were calculated to be 0.2-0.3 indoors and 0.3-0.4 outdoors. Indoor radon concentration had a weak positive correlation with gamma-dose rate. Since there is a possibility that high radon concentrations exist indoors during the cool season in Taiwan because of extremely low ventilation rates in the dwellings, a winter survey in January through February will be needed for future estimation of the annual effective dose.  相似文献   

6.
During 1998 regional surveys were conducted to evaluate natural radiation exposure of people in the vicinity of the six Spanish nuclear power stations. Indoor radon, external gamma dose rates outdoors and indoors and radioactivity in soil were measured in these surveys. The highest mean annual effective dose to the population was found in the surroundings of the Almaraz nuclear power plant in the province of Cáceres and was mainly due to the presence of high radon concentrations in homes. In order to make a more accurate assessment of the dose coming from the radon in this area, a new and more extensive surgery on indoor radon with a total of 380 measurements was carried out in 2000 in the Campo Ara?uelo region around the Almaraz nuclear power station. From the results obtained in this survey, a population-weighted mean annual effective dose from radon exposure of 1.7 mSv y(-1), 44% lower than that previously reported in 1998, was estimated for the whole Campo Ara?uelo region. The maximum dose value due to radon exposure, about 4 mSv y(-1), was reached in the so-called La Vera area located in the north of this region. The relationship between the indoor radon concentrates experimentally measured, the geological characteristics of this geographic area and the information provided by the radiation map of the Spanish MARNA Project is also analyzed, confirming that La Vera area should be considered as a high radon level area.  相似文献   

7.
Evaluation was made of the distribution of radon gas and radiation exposure rates in the four main natural gas treatment facilities in Syria. The results showed that radiation exposure rates at contact of all equipment were within the natural levels (0.09-0.1 microSvh(-1)) except for the reflex pumps where a dose rate value of 3 microSvh(-1) was recorded. Radon concentrations in Syrian natural gas varied between 15.4 Bq m(-3) and 1141 Bq m(-3); natural gas associated with oil production was found to contain higher concentrations than the non-associated natural gas. In addition, radon concentrations were higher in the central processing facilities than the wellheads; these high levels are due to pressurizing and concentrating processes that enhance radon gas and its decay products. Moreover, the lowest 222Rn concentration was in the natural gas fraction used for producing sulfur; a value of 80 Bq m(-3) was observed. On the other hand, maximum radon gas and its decay product concentrations in workplace air environments were found to be relatively high in the gas analysis laboratories; a value of 458 Bq m(-3) was observed. However, all reported levels in the workplaces in the four main stations were below the action level set by IAEA for chronic exposure situations involving radon, which is 1000 Bq m(-3).  相似文献   

8.
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m(-3). Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m(-3) and Una in the northern part of India had the highest concentration of 281.5 Bq m(-3). This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.  相似文献   

9.
The paper presents results of natural radioactivity levels in the atmosphere obtained for a 5 years period (1994-1999) at the Bucharest Environmental Radioactivity Surveillance Station (BERSS). The variability of radon and thoron progeny activity concentrations is analysed in relation to the local dynamics of the meteorological parameters (wind speed, air temperature, air pressure, cloud cover, relative humidity). The radon and thoron progeny concentrations display a daily and seasonal variation, with the highest values in the early morning and the lowest values in the afternoon. The outdoor radon progeny concentrations show maximum values in autumn and minimum values in spring-summer. The outdoor thoron progeny concentrations display maximum values in autumn and minimum values in winter. Significant statistical correlations with the meteorological parameters were obtained. The study on the temporal variability of natural atmospheric radioactivity near Bucharest is a starting point for further assessment of the radiological consequences resulting from human activities.  相似文献   

10.
The measurement campaigns have been done in the rural community of Niska Banja, a spa town located in southern Serbia, to evaluate population exposure to natural radioactivity. After a screening survey in 200 houses, annual radon and thoron concentrations were measured in 34 houses, and in 2004 a detailed investigation was carried out at six houses with elevated indoor radon concentrations. The paper presents the results of these detailed measurements. The complementary techniques were applied to determine radon and thoron concentrations in indoor air, in soil gas, radon exhalation from soil, soil permeability, and indoor and outdoor gamma doses. Soil and water samples were collected and analysed in the laboratory. Indoor radon and thoron concentrations were found to be more than 1kBqm(-3) and 200Bqm(-3), respectively. Extremely high concentrations of soil-gas radon (>2000kBqm(-3)) and radon exhalation rates (1.5mBqm(-2)s(-1)) were observed. These results will be utilised to set up the methodology for a more systematic investigation.  相似文献   

11.
Concentrations of airborne radon ranging from 0.05 to 135 pCi/L were found in houses in Maine. Tracketch cups were placed in five positions for 100 houses to determine integrated average radon concentrations over the period October 1980–May 1981. To investigate the association between elevated radon concentrations in well water and the indoor airborne radon concentrations, the radon in the water supplies of these houses was measured by liquid scintillation. Monitors of airborne radon, recording in intervals of 10 min for periods of 5–7 days, were used for dynamic studies in 18 houses, determining the component of airborne radon associated with major water uses, such as showers, laundry, and dishwashing, which liberate radon in bursts. House residents kept logs noting the time of major water uses. For some of the houses, ventilation rates ranging from 0.3 to 2 air changes per hour were determined by analysis of the dynamic data. The component of airborne radon associated with water sources was found to vary inversely with ventilation rate and directly with waterborne radon concentration, with 0.8 ± 0.2 pCi Rn/L air per nCi Rn/L water at a ventilation rate of 1.0 air change per hour. The data are pertinent to a study which has revealed significant correlations between county averages, from the National Cancer Institute, or age-adjusted cancer mortality rates in Maine and average values of radon concentrations in water for the counties.  相似文献   

12.
Indoor radon distribution of subway stations in a Korean major city   总被引:1,自引:0,他引:1  
The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 ± 14.7 Bq m−3, and the range of values was from 9.4 to 98.2 Bq m−3. The radon concentrations in groundwater (average 31.0 ± 0.8 Bq m−3) were not significantly high in most stations, but the concentration (177.9 ± 2.3 Bq L−1) of one station was over the level of 148 Bq L−1 in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y−1, and 0.02 mSv y−1, respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.  相似文献   

13.
Any confined air volume holding radon (222Rn) gas bears a memory of past radon concentrations due to 210Pb (T1/2 = 22 y) and its progenies entrapped in all solid objects in the volume. The efforts of quantifying past radon exposures by means of the left-behind long-lived radon progenies started in 1987 with this author’s unsuccessful trials of removing 214Po from radon exposed glass objects. In this contribution the history and different techniques of assessing radon exposure to man in retrospect will be overviewed. The main focus will be on the implantation of alpha recoils into glass surfaces, but also potential traps in radon dwellings will be discussed. It is concluded that for a successful retrospective application, three crucial imperatives must be met, i.e. firstly, the object must persistently store a certain fraction of the created 210Pb atoms, secondly, be resistant over decades towards disturbances from the outside and thirdly, all 210Pb atoms analysed must originate from airborne radon only.For large-scale radon epidemiological studies, non-destructive and inexpensive measurement techniques are essential. Large-scale studies cannot be based on objects rarely found in dwellings or not available for measurements  相似文献   

14.
A new winter and summer investigation of radon concentrations in parts of the Ogof Ffynnon Ddu system at Penwyllt, South Wales, has been carried out using 100 environmental National Radiological Protection Board track etch detectors. Fifty detectors were installed in the system in December 1998 and again in August 1999 for a period of a month. The data obtained confirm that the system has moderately high radon concentrations with a system mean of 2318 Bq m(-3) in winter and 2844 Bq m(-3) in summer. Traverse means have a summer high of 3094 Bq m(-3) for OFDI to Cwm Dwr and a winter low of 1946 Bq m(-3). The extremely high concentrations approaching 20,000 Bq m(-3), reported previously from the system (Hyland, 1995), have not been reproduced. The data show that the airflow directions at the entrances are not what might have been predicted. Air appears to be largely continuously emerging from the lowest entrance but, at the higher entrances, conversely to the predictions, in winter air enters and in summer appears to be coming out or is variable. Internally, there are sites that in winter have very low radon concentrations that can only be explained by the ingress of fresh air. These are not matched in the summer experiment, again indicating that ingress of fresh air to some parts of the system is very variable. The data illustrate the complexity of airflow within a multi-entrance system but behind these variations several mean concentrations can be obtained from which an approximation of the dose likely to be received can be calculated. Using the maximum mean concentration obtained, 3094 Bq m(-3), and using the latest dose conversion, a 10 h underground trip in the Ogof Ffynnon Ddu system yields a calculated dose of 0.12 mSv. Given that the recommended limit for a member of the public is 1 mSv, this dose would be reached after about 80 h of caving in the system.  相似文献   

15.
To predict the radon concentration in a house environment and to understand the role of all factors affecting its behavior, it is necessary to recognize time variation in both air exchange rate and radon entry rate into a house. This paper describes a new approach to the separation of their effects, which effectively allows continuous estimation of both radon entry rate and air exchange rate from simultaneous tracer gas (carbon monoxide) and radon gas measurement data. It is based on a state-space statistical model which permits quick and efficient calculations. Underlying computations are based on (extended) Kalman filtering, whose practical software implementation is easy. Key property is the model's flexibility, so that it can be easily adjusted to handle various artificial regimens of both radon gas and CO gas level manipulation. After introducing the statistical model formally, its performance will be demonstrated on real data from measurements conducted in our experimental, naturally ventilated and unoccupied room. To verify our method, radon entry rate calculated via proposed statistical model was compared with its known reference value. The results from several days of measurement indicated fairly good agreement (up to 5% between reference value radon entry rate and its value calculated continuously via proposed method, in average). Measured radon concentration moved around the level approximately 600 Bq m(-3), whereas the range of air exchange rate was 0.3-0.8 (h(-1)).  相似文献   

16.
Vertical profiles of radioactive radon gas ((222)Rn) and dissolved gaseous mercury (DGM) in seawater in the Mediterranean Basin have been measured. They were found in the range 1.7-19.3 Bq m(-3) and 22-200 ng m(-3), respectively, at the bottom and 2.0-20.0 Bq m(-3) and 6-80 ng m(-3), respectively, at the surface. Preliminary results indicate a positive correlation between concentrations of both gases at some locations, but not at others. Further analyses will be performed, after (226)Ra contents in sediment and water have been determined, taking into account environmental parameters such as air and water temperatures, barometric pressure and water flow, in order to better interpret these profiles.  相似文献   

17.
A radiological impact assessment was carried out at the 4000 MW Nanticoke Thermal Generating Station on the north shore of Lake Erie and at an ash disposal site in Metropolitan Toronto, both operated by Ontario Hydro. Analyses were performed on feed coal, fly ash and bottom ash and on samples of air filters, precipitation, water, soil and vegetation in the vicinity of the generating station. The measured radionuclide levels in the vicinity of the generating station showed no evidence of enhancement from station emissions. There were no indications that leaching of radionuclides or emanation of radon gas from ash disposal sites would be a problem. There was evidence, however, of higher radionuclide concentrations on the finer ash particles. Furthermore, the use of fly ash in building materials could lead to enhanced radiation levels. Atmospheric dispersion and radiation dose calculations were also carried out. Predicted concentrations in air were all less than 1% of background values. The committed dose equivalent from one year of operation was estimated to be 0·27 μSv at the site boundary and 0·11 μSv at 10 km east of the site.  相似文献   

18.
In order to maintain an acceptable Indoor Air Quality (IAQ), policies, strategies and guidelines have been developed worldwide and exposure concentrations of the indoor radon have been specified. Mapping indoor radon levels for a region could be done with intensive measurements on a large number of samples. To obtain the most accurate estimate of the levels with the uncertainties specified, a statistical model has been developed in this study to predict the fractions of samples in a region having an average radon level above the action levels of 150Bqm(-3) and 200Bqm(-3). The model was based on a transformation of the variation from a small sample set of data to a population geometric distribution via an estimator, known as the 'sample correction factor'. Using a dataset from a cross-sectional measurement of indoor radon levels in 216 Hong Kong offices, where the mean was 37.2Bqm(-3) and the 68% range was from 17.3Bqm(-3) to 80.3Bqm(-3), the 'sample correction factor' was evaluated and tested by the Monte-Carlo simulations. The model estimates of the fractions above the indoor radon action levels 150Bqm(-3) and 200Bqm(-3) (1.2-7.7% and 0.4-4.1% for a sample size of 20, 2.8-5.1% and 0.8-2.4% for a sample size of 60) were demonstrated to be consistent with those determined from the dataset (3.5% and 1.4%). With the 'sample correction factor' thus quantified, it will be possible to provide the required data for the policymakers making appropriate decisions on resources and manpower management.  相似文献   

19.
Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m3 radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces.  相似文献   

20.
The scope for using Tellus Project airborne gamma-ray spectrometer and soil geochemical data to predict the probability of houses in Northern Ireland having high indoor radon concentrations is evaluated, in a pilot study in the southeast of the province, by comparing these data statistically with in-house radon measurements. There is generally good agreement between radon maps modelled from the airborne radiometric and soil geochemical data using multivariate linear regression analysis and conventional radon maps which depend solely on geological and indoor radon data. The radon maps based on the Tellus Project data identify some additional areas where the radon risk appears to be relatively high compared with the conventional radon maps. One of the ways of validating radon maps modelled on the Tellus Project data will be to carry out additional indoor measurements in these areas.  相似文献   