首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 422 毫秒
1.
Porous silica spheres were investigated for their effectiveness in removing typical indoor air pollutants, such as aromatic and carbonyl-containing volatile organic compounds (VOCs), and compared to the commercially available polymer styrene-divinylbenzene (XAD-4). The silica spheres and the XAD-4 resin were coated on denuder sampling devices and their adsorption efficiencies for VOCs evaluated using an indoor air simulation chamber. Real indoor sampling was also undertaken to evaluate the affinity of the silica adsorbents for a variety of indoor VOCs. The silica sphere adsorbents were found to have a high affinity for polar carbonyls and found to be more efficient than the XAD-4 resin at adsorbing carbonyls in an indoor environment.  相似文献   

2.
A denuder/filter system constructed for solvent-free personal exposure measurements was evaluated for separation of vapour and particulate 4,4'-methylenediphenyl diisocyanate (4,4'-MDI) generated from heated PUR-foam. The two different phases were collected in the denuder and on the filter, respectively, by chemosorption on a polydimethylsiloxane (SE-30)-dibutylamine (DBA) stationary phase. Both repeatability and the total mass concentration of 4,4'-MDI were similar to that obtained from the reference method, in this case an impinger/filter system. The penetration of particles through the denuder at 300 ml min(-1) was nearly 100% in the particle size range 25 to 700 nm, which fits well with the Gormley-Kennedy equation. Denuder/filter sampling of the 4,4'-MDI aerosol at 500 ml min(-1) yielded a phase distribution that was in accordance with the results from the reference method. The method limit of detection was 6 ng m(-3) and 4 ng m(-3) for the denuder and filter, respectively, when using an air sampling flow rate of 300 ml min(-1) and a sampling period of 15 min. This is well below the Swedish occupational exposure limit (OEL) of 50 and 100 microg m(-3) for an 8-hour working day and a 5-min period, respectively.  相似文献   

3.
The use of a large volume polyurethane foam (PUF) sampler was validated for rapid extraction of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in raw water and treated water from drinking water plants. To validate the recovery of target compounds in the sampling process, a (37)Cl-labeled standard was spiked into the 1st PUF plug prior to filtration. An accelerated solvent extraction method, as a pressurized liquid extractor (PLE), was optimized to extract the PUF plug. For sample preparation, tandem column chromatography (TCC) clean-up was used for rapid analysis. The recoveries of labeled compounds in the analytical method were 80-110% (n = 9). The optimized PUF-PLE-TCC method was applied in the analysis of raw water and treated potable water from seven drinking water plants in South Korea. The sample volume used was between 18 and 102 L for raw water at a flow rate of 0.4-2 L min(-1), 95 and 107 L for treated water at a flow rate of 1.5-2.2 L min(-1). Limit of quantitation (LOQ) was a function of sample volume and it decreased with increasing sample volume. The LOQ of PCDD/Fs in raw waters analyzed by this method was 3-11 times lower than that described using large-size disk-type solid phase extraction (SPE) method. The LOQ of PCDD/F congeners in raw water and treated water were 0.022-3.9 ng L(-1) and 0.018-0.74 ng L(-1), respectively. Octachlorinated dibenzo-p-dioxin (OCDD) was found in some raw water samples, while their concentrations were well below the tentative criterion set by the Japanese Environmental Ministry for drinking water. OCDD was below the LOQ in the treated drinking water.  相似文献   

4.
In this work we present the results of extensive characterization and optimization of the Ambient Ion Monitor-Ion Chromatograph (AIM-IC) system, an instrument developed by URG Corp. and Dionex Inc. for simultaneous hourly measurements of the water-soluble chemical composition of atmospheric fine particulate matter (PM(2.5)) and associated precursor gases. The sampling assembly of the AIM-IC consists of an inertial particle size-selection assembly, a parallel-plate wet denuder (PPWD) for the collection of soluble gases, and a particle supersaturation chamber (PSSC) for collection of particles, in series. The analytical assembly of the AIM-IC consists of anion and cation IC units. The system detection limits were determined to be 41 ppt, 5 ppt, and 65 ppt for gas phase NH(3(g)), SO(2(g)), and HNO(3(g)) and 29 ng m(-3), 3 ng m(-3), and 45 ng m(-3) for particle phase NH(4)(+), SO(4)(2-), and NO(3)(-) respectively. From external trace gas calibrations with permeation sources, we determined that the AIM-IC is biased low for NH(3(g)) (11%), SO(2(g)) (19%), and HNO(3(g)) (12%). The collection efficiency of SO(2(g)) was found to strongly depend on the composition of the denuder solution and was found to be the most quantitative with 5 mM H(2)O(2) solution for mixing ratios as high as 107 ppb. Using a cellulose membrane in the PPWD, the system responded to changes in SO(2(g)) and HNO(3(g)) within an hour, however for NH(3(g)), the timescale can be closer to 20 h. With a nylon membrane, the instrument response time for NH(3(g)) was significantly improved, becoming comparable to the responses for SO(2(g)) and HNO(3(g)). Performance of the AIM-IC for collection and analysis of PM(2.5) was evaluated by generating known number concentrations of ammonium sulfate and ammonium nitrate particles (with an aerodynamic diameter of 300 nm) under laboratory conditions and by comparing AIM-IC measurements to measurements from a collocated Aerosol Mass Spectrometer (AMS) during a field-sampling campaign. On average, the AIM-IC and AMS measurements agreed well and captured rapid ambient concentration changes at the same time. In this work we also present a novel inlet configuration and plumbing for the AIM-IC which minimizes sampling inlet losses, reduces peak smearing due to sample carryover, and allows for tower-height sampling from the base of a research tower.  相似文献   

5.
While polyurethane foam (PUF) disk passive air samplers are employed increasingly to monitor persistent organic pollutants in indoor air, they essentially sample only the vapour phase. As a previous investigation of the vapour : particle phase partitioning of hexabromocyclododecanes HBCDs in (outdoor) air reported them to be present largely in the particulate phase, we monitored three offices using active air samplers. In each, approximately 65% of HBCDs were present in the vapour phase, suggesting PUF disk passive samplers are suitable for monitoring HBCDs in indoor air. Concentrations in the three offices (239-359 pg Sigma HBCD m(-3)) exceed substantially those reported in outdoor air from the United States (2.1-11 pg Sigma HBCD m(-3)), but are in line with outdoor air from Stockholm. The relative abundance of the three principal diastereomers in office air was closer to that found in technical HBCD formulations (i.e. predominantly gamma-HBCD) than in most US outdoor air samples. Time integrated air concentrations of alpha-, beta-, and gamma-HBCD were obtained for an office using a low volume sampler operated over a 50 d period alongside PUF disk samplers. This calibration exercise yielded the following passive air sampling rates for both a fully- and part-sheltered PUF disk sampler design: for alpha-, beta-, and gamma-HBCD, 0.87, 0.89, and 0.91 m3 d(-1) respectively (fully-sheltered) and 1.38, 1.54, and 1.55 m3 d(-1) respectively (part-sheltered). Deployment of the part-sheltered configuration yielded concentrations approximately 35% lower than those obtained using a high volume sampler, consistent with PUF disk samplers measuring primarily the vapour phase.  相似文献   

6.
Two field studies were conducted for one year using sorbent-impregnated polyurethane foam (SIP) disks for PCB and PBDE air sampling. SIP disks were introduced by Shoeib et al. (2008) as an alternative passive air sampling medium to the polyurethane foam (PUF) disk and have the advantage of a higher holding capacity for organic chemicals. The first study on SIP disks confirmed their application for measuring volatile perfluorinated compounds (PFCs) and their ability to maintain time-integrated (linear) air sampling. In this study, the suitability of the SIP disks for long-term sampling of polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and hexachlorobenzene (HCB) was assessed. SIP disks were deployed at a rural site in the UK and harvested after periods ranging from 35-350 days. Atmospheric POP concentrations were monitored with a high-volume air sampler during the deployment period. Linear uptake was observed for all monitored PCBs and PBDEs over the full exposure time. Air-sampler equilibrium was observed for HCB after 6 months. In a second field study, SIP disks were deployed for one year at 10 sites on a latitudinal transect in the UK and Norway, at which air sampling has been undertaken previously with different passive air sampling media since 1994. The estimated concentrations and spatial distributions derived from the SIP disks were largely in agreement with previously reported data.  相似文献   

7.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

8.
大气中半挥发性有机物的测定与来源分析   总被引:5,自引:0,他引:5  
研究了大气中半挥发性有机物(SVOC)在滤膜、聚氨基甲酸酯泡膜(PUF)和XAD-2三层上的分布,青岛市大气中SVOC的组分和主要有机物的浓度。大气中的SVOC部分四环和五环以上的多环芳烃主要吸附在滤膜层,而大部分SVOC吸附在PUF层,XAD-2吸附的有机物主要是三甲苯和单体萘。冬季大气中主要的有机物是四环以下PAHs的烷基取代物和多种烷基酚,酚类化合物在冬夏两季的变化最大,夏季中检不出酚类化合物,酚类化合物主要来源于燃煤,而PAHs及烷基取代物来源于燃煤和交通。冬夏两季大气中均能检出与交通有关的己内酰胺。  相似文献   

9.
The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.  相似文献   

10.
电线电缆行业漆包线生产工艺废气中有机物的GC/MS测定   总被引:1,自引:0,他引:1  
本文以活性炭、TenaxGC、聚氨酯泡沫为吸附材料,用二硫化碳洗脱、二氯甲烷提取、加热解吸三种脱附方式,并以色谱/质谱(GC/MS)联用仪为测试手段,对漆包线生产工艺废气中的有机物进行了测定,共检出72种有机化合物。本文进行了不同采集方式间的比较,提出了电线电缆行业工艺废气中有机化合物的系统分析方法。  相似文献   

11.
This study is an analysis of the concentrations and components of heavy metals in PM2.5 and the total suspended particulate (TSP) collected at a mechanical industrial complex (IC) site in Changwon and at a residential site in Masan, Korea. Particulate was collected during two sampling periods, from the late summer to the early fall and from the middle to late fall, at the IC site and one sampling period, from the middle fall to the early winter, at the residential site. PM2.5 and TSP samples were taken by an annular denuder system and a hi-volume air sampler, respectively. The authors also identified the concentrations and components of heavy metals extracted from the PM2.5 and TSP filters, the acidic components extracted from the PM2.5 filters, and the polycyclic aromatic hydrocarbons (PAHs) extracted from polyurethane foam (PUF) plug. The average concentrations of the PM2.5 collected at the IC and residential sites were very similar. Major sources of PM2.5 at the study sites, however, were air emissions from vehicles and industry as well as emissions from residential heating and soil origins, respectively. The higher concentrations of the TSP at the IC site, as compared to those at the residential site, were due to either increased suspended dust from vehicle emissions or re-suspended road dust because of increased vehicle speeds near the IC site. Heavy metal concentrations in the TSPs were higher than those in the PM2.5. The heavy metal concentrations in the PM2.5 and TSP at the IC site with heavy traffic were substantially greater than those at the residential site. The concentrations of TSP and heavy metals and PAHs in PM during the period of the middle to late fall was much higher than those during the period of the late summer to early fall at the IC site. This is because of the difference in meteorological characteristics and energy uses between two periods. The residential site also showed higher concentrations of acidic anions while the IC site showed higher concentrations of acidic cation. Secondary aerosols or particulates, such as ammonium nitrate or ammonium nitrite, might have been important constituents of the PM2.5 at the residential site. The PAHs in the TSP collected at the IC site was greatly affected by traffic and industry emissions consisting mostly of high molecular weight PAHs with two to four rings. PAHs in the TSP at the site, however, were affected by residential heating and air emissions from small chemical plants having higher concentrations of low molecular weight PAHs with five to six rings.  相似文献   

12.
Agricultural production systems are recognised as a major source of atmospheric ammonia. Deposition of ammonia and ammonium may contribute to undesired changes in oligotrophic ecosystems. The continuous measurement of atmospheric ammonia requires expensive and sophisticated techniques and is performed only in a very restrict number of ambient air stations in Europe. Therefore, the application of passive samplers, which have the advantage of being easy to handle and cost-efficient, is useful. In the past the comparability of different passive samplers must be considered as rather scarce. In a joint European project under the leadership of the GSF-Forschungszentrum für Umwelt und Gesundheit, Neuherberg, in 1997 a comparison of different passive ammonia monitoring methods was carried out in a prealpine rural site near Garmisch-Partenkirchen. It was considered valuable to include not only well established systems but also methods still being developed. For the comparative test ten working groups with different methods took part. A wet annular denuder system, which has been developed by the Netherlands Energy Research Foundation for on-line measurement of atmospheric ammonia, served as reference of passive methods. The experiment, which started in June and finished in December, showed that most of the passive samplers fulfil the requirements and can be recommended for further measurements. Additional measurements of meteorological parameters were performed to check the influences of different weather conditions on passive sampling.  相似文献   

13.
This study describes the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils, among ground personnel within the aviation industry. The OPs tri-n-butyl phosphate (TnBP), dibutyl phenyl phosphate (DBPP), triphenyl phosphate (TPP) and tricresyl phosphate (TCP) have been emphasized due to their use in such oils. Oil aerosol/vapor and total volatile organic compounds (tVOCs) in air were also determined. In total, 228 and 182 OPs and oil aerosol/vapor samples from technician and loader work tasks during work on 42 and 21 aircrafts, respectively, were collected in pairs. In general, the measured exposure levels were below the limit of quantification (LOQ) for 84%/98% (oil aerosol) and 82%/90% (TCP) of the samples collected during technician/loader work tasks. The air concentration ranges for all samples related to technician work were 相似文献   

14.
The aim of the study was to develop a sampling method aimed at individual sampling of mercury vapor and subsequent individualexposure assessment of the worker. Hopcalite available fromInowrocawskie Zakady Chemiczne (in Poland) was founduseful for mercury vapor sampling in active and passive individual samplers. However the sampling rate determined forpassive sampler in steady-state laboratory chamber cannot be usedunder fluctuating conditions of mercury vapor concentration andair movement typical for field measurement. In order to check comparativeness of passive and active sampling methods, sampleswere taken in the same time and individual samplers fixed toworker's clothes were used. Mercury vapor concentration wasmeasured at two chloralkali industries in Poland and the resultswere presented. Excessive exposure in both industries wasconfirmed by finding elevated mercury concentration in urinesamples from the workers.  相似文献   

15.
16.
The objective of this study was to determine filter materials and extraction methods that are appropriate to use for environmental sampling of B. anthracis. Four types of filters were tested: mixed cellulose ester (MCE) with a pore size of 3 microm, polytetrafluoroethylene (PTFE) with pore sizes of 1 and 3 microm, and gelatin with a pore size of 3 microm. Bacillus subtilis var. niger endospores (also known as Bacillus globigii[BG]) were used as a surrogate for B. anthracis. Endospores were collected into Button Inhalable Aerosol Samplers with sampling times of 15 minutes, 1 hour, and 4 hours. Physical collection efficiency was determined by measuring upstream and downstream B. subtilis concentrations with an optical particle counter. Vortexing with ultrasonic agitation and vortexing with shaker agitation extraction methods were evaluated. The MCE, 1 microm PTFE, and gelatin filters provided physical collection efficiencies of 94% or greater. The 3 microm PTFE filter showed inconsistent physical efficiency characteristics between filters. Epifluorescence microscopic analysis of the gelatin filter extraction fluid revealed the presence of contamination by non-culturable bacteria. Mean differences for microbial culturability were not statistically significant for filter materials and extraction methods. However, the vortexing with shaker agitation extraction method resulted in higher total microbial counts in the extraction fluids for MCE and 1 microm PTFE filters when compared to vortexing with ultrasonic agitation. In summary, the MCE and 1 microm PTFE filters in combination with vortexing and shaker extraction demonstrated the best performance for the filter collection and extraction of BG spores.  相似文献   

17.
主动采样技术在中国大气POPs监测中的应用   总被引:2,自引:0,他引:2  
为了履行斯德哥尔摩公约,查明持久性有机污染物(POPs)在中国大气环境介质的存在水平,该研究首次采用主动采样技术,在中国境内大尺度范围内进行了环境大气中POPs的监测工作.利用主动采样技术,可以在短时间内采集数百立方米的大气样品.分别利用玻璃纤维滤膜采集大气颗粒物(固相)中的POPs,同时使用聚氨酯泡沫(PUF)吸附气态的POPs.该采样技术还便于样品的运输和保存.研究表明,大气主动采样技术可以很好地运用于区域大气POPs的监测工作并填补了我国在POPs履约监测中专用仪器设备的空白.  相似文献   

18.
Suspended solids either as total suspended solids (TSS) or suspended sediment concentration (SSC) is an integral particulate water quality parameter that is important in assessing particle-bound contaminants. At present, nearly all stormwater runoff quality monitoring is performed with automatic samplers in which the sampling intake is typically installed at the bottom of a storm sewer or channel. This method of sampling often results in a less accurate measurement of suspended sediment and associated pollutants due to the vertical variation in particle concentration caused by particle settling. In this study, the inaccuracies associated with sampling by conventional intakes for automatic samplers have been verified by testing with known suspended sediment concentrations and known particle sizes ranging from approximately 20 μm to 355 μm under various flow rates. Experimental results show that, for samples collected at a typical automatic sampler intake position, the ratio of sampled to feed suspended sediment concentration is up to 6600% without an intake strainer and up to 300% with a strainer. When the sampling intake is modified with multiple sampling tubes and fitted with a wing to provide lift (winged arm sampler intake), the accuracy of sampling improves substantially. With this modification, the differences between sampled and feed suspended sediment concentration were more consistent and the sampled to feed concentration ratio was accurate to within 10% for particle sizes up to 250 μm.  相似文献   

19.
A denuder/filter apparatus was used to collect the gaseous and particulate reaction products from ozonlysis of α-pinene, limonene and α-terpineol in an effort to develop sampling techniques for characterizing indoor environment chemistry. Carboxylic acids found in the particulate phase were derivatized to 2,2,2-trifuoroethylamides by reaction with 3-ethyl-1-[3-(dimethylamino)propyl]carbodiimide hydrochloride (EDC) and 2,2,2-trifluoroethylamine hydrochloride (TFEA). Carbonyl compounds collected in both gas phase and particulate phase were derivatized to their respective oximes by reaction with O-(2,3,4,5,6-pentafluoro-benzyl)hydroxylamine hydrochloride (PFBHA). The ozonolysis of α-pinene yielded the carboxylic acids: cis-pinonic acid and pinic acid and the proposed carboxylic acids methanetricarboxylic acid and terpenylic acid; the carbonyls: 4-oxopentanal, norpinonaldehyde, pinon aldehyde and the proposed carbonyl methylidenepropanedial. The ozonolysis of limonene yielded the carboxylic acids: limonic acid and pinic acid and the carbonyls: 1-(4-methylcyclohex-3-en-1-yl)ethanone (4AMCH), glyoxal, methyl glyoxal, 4-oxopentanal and 6-oxo-3-(prop-1-en-2-yl)heptanal (IPOH). The ozonolysis of α-terpineol yielded the proposed carboxylic acids: terpenylic acid and homoterpenylic acid and the carbonyls: (5E)-6-hydroxyhept-5-en-2-one, methyl glyoxal and 4-oxopentanal.  相似文献   

20.
Recent laboratory research indicates physiologic sampling of gas and vapor may provide more representative estimates of personal exposures than traditional methods. Modifications to the physiologic sampling pump (PSP) used in that research are described which extend its usefulness to size-selective sampling of particulates. PSPs used in previous research varied motor speed to keep sampling proportional to the subject's inhalation. This caused airflow and particle velocities through the collection device to continually change making those pumps unsuitable for sampling particulates. The modified implementation of the PSP pulls a constant airflow into and through a cyclone, then uses valves to either direct the airflow through, or divert the airflow around, the sampling filter. By using physiologic inputs to regulate the fraction of each second that air flows through the sampling filter, samples may be collected in proportion to inhalation rate. To evaluate the performance of a functional prototype 5 different sizes of monodisperse aerosols of ammonium fluorescein were generated by a vibrating orifice aerosol generator and introduced into a calm air chamber. To simulate different inhalation rates the valves of the PSP were energized using 9 different duty cycles. Efficiency curves are presented and compared to a standard respirable convention by bias mapping. The performance of the modified cyclone used in the PSP sampling head compared favorably with a commercially available cyclone of the same model, operating at a constant airflow (± 10% over almost all the size distributions of concern). The new method makes physiologic sampling of the respirable fraction of particulates feasible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号