1.
O_3-MBR法深度处理煤气废水   总被引:3,自引:0,他引:3  
以经多级生物处理后的煤气废水为原水,采用O3-MBR组合工艺对其进行深度处理,以满足回用要求.结果表明:采用臭氧氧化工艺,当废水pH为11和臭氧投加量〔ρ(臭氧)〕为189.2mg/L时,CODCr和色度的去除率分别为46.5%和80.2%,ρ(BOD5)/ρ(CODCr)由0.02升至0.29,废水的可生化性得到明显改善;臭氧氧化工艺出水再通过MBR作进一步处理,CODCr,NH3-N和色度的去除率分别达23.0%,76.3%和70.0%,且出水水质稳定;总体上,废水经O3-MBR组合工艺处理,CODCr,NH3-N,色度和浊度的平均总去除率分别达到58.7%,76.3%,88.6%和95.1%;处理后出水的ρ(CODCr)50mg/L,ρ(NH3-N)5mg/L,浊度0.2NTU,色度约为30度,出水水质满足生产工艺回用的要求.  相似文献   

2.
彭枫  潘霞 《环境工程》2014,32(5):14-16
采用臭氧-活性炭工艺对焦化废水生化出水进行深度处理试验。结果表明:臭氧-活性炭工艺对焦化废水生化出水具有良好的深度处理效果。在空气流量为75 L/h,臭氧浓度为100 mg/L,pH=10.5,反应时间为30 min的最佳试验条件下,当深度处理进水水质ρ(COD)=156.5 mg/L、色度=110倍时,其去除率分别为69.65%和92.27%,出水COD和色度的平均值分别为47.50 mg/L和8.50倍,均达焦化废水排放新标准。  相似文献   

3.
纺织印染厂废水的深度处理中试及工程应用   总被引:2,自引:1,他引:1  
采用曝气生物滤池(BAF)-臭氧-曝气生物滤池工艺对广东某大型纺织印染厂的常规水解酸化-接触生物氧化处理出水进行深度处理回用中试,在中试研究成功的基础上,设计了每小时处理5 t的工业化试验装置。试验运行结果表明:进水COD为100~150 mg/L,色度约80倍,浊度约10 NTU,在前BAF水力停留时间3 h,中间化学氧化池中臭氧投加量40 mg/L,后BAF水力停留时间2 h的情况下,经组合工艺处理后出水COD约30 mg/L,色度2倍,浊度<1 NTU,该工艺处理后的出水,可直接回用于对电解质浓度要求不高的生产工艺中,也可作为反渗透或纳滤膜的预处理工序。  相似文献   

4.
采用臭氧-移动床生物膜组合工艺深度处理河北省某制革园区综合废水,通过考察臭氧投加量、臭氧接触时间对废水COD、UV254、色度处理效果的影响,确定臭氧最佳投加量为20 mg/L,最佳接触时间为40 min。在臭氧最佳运行条件下,MBBR停留时间为15 h,臭氧-移动床生物膜组合工艺出水COD、氨氮、色度可达GB 18918—2002《城镇污水处理厂污染物排放标准》一级A排放标准,出水COD为41~50 mg/L、氨氮为0.5~0.7 mg/L、色度为10~20。  相似文献   

5.
膜生物反应器处理毛纺废水的中试研究   总被引:30,自引:2,他引:28  
采用中试规模(10t/d)的厌氧-好氧膜生物反应器(A/O MBR)处理毛纺印染废水.当HRT为7h,进水COD、BOD5分别为179~358mg/L和44.8~206mg/L,试验系统对COD、BODs、色度、浊度的平均去除率分别为92.1%、98.4%、60.7%、98.9%,出水水质浓度或指标值分别为20.2mg/L、1.6mg/L、25倍、0.51 NTU.出水水质指标达到建设部生活杂用水水质标准(CJ25.1-89).A/O MBR工艺处理毛纺印染废水技术可行、操作简单、易于管理,可为工业规模应用提供技术参考.  相似文献   

6.
厌氧反应器与好氧MBR组合工艺处理毛纺印染废水试验研究   总被引:10,自引:0,他引:10  
郑祥  刘俊新 《环境科学》2004,25(5):102-105
采用厌氧反应器与膜生物反应器(MBR)组合工艺处理毛纺印染废水,结果表明,当进水COD、BOD5和色度分别为128~321 mg/L、36~95 mg/L和40~70倍时,出水COD、BOD5、色度、浊度的平均值分别为36.9 mg/L、3.7 mg/L、21倍、0.24 NTU,平均去除率分别达到80.3%%、95%、59%、99.3%,达到生活杂用水水质标准.在本研究中,开发了一种新型的利用生物反应器内液位水头重力驱动连续出水的重力出流式膜生物反应器.在保留MBR处理效率高等优点的同时,省去传统的一体式MBR出水抽吸泵及复杂的反冲洗设备.整个系统结构紧凑,投资少,操作简便.选择合适的曝气量有助于提高膜通量,且可降低膜阻力的上升速率,有利于膜污染的控制.  相似文献   

7.
溢达纺织有限公司纺织综合废水水质为 :pH 10~ 14、CODCr10 0 0~ 15 0 0mg L、BOD530 0~ 4 5 0mg L、SS 30 0mg L、S2 - 3mg L ,水温 4 0~ 5 0℃、色度 4 0 0~ 6 0 0倍 ,采用水解酸化 生物接触氧化 漂白氧化脱色处理工艺 ,处理后出水达到排放目标。经过 2a多时间的运行实践 ,结果表明 ,处理的出水水质稳定。  相似文献   

8.
臭氧氧化深度处理二级处理出水的研究   总被引:7,自引:0,他引:7       下载免费PDF全文
以某城市污水处理厂二级处理出水为原水,研究了臭氧氧化深度处理对水中残留有机物以及病原微生物的降解和去除效果.结果表明,臭氧投加量达到6mg/L时,DOC、UV254、色度的去除率分别为15.49%、36.36%、73.61%,环境激素类痕量有机物邻苯二甲酸二丁酯(DBP)和邻苯二甲酸二(2-乙基己基)酯(DEHP)的去除率分别为37.29%和14.6%,三维荧光光谱荧光峰的各区域有机物质平均去除率在80%以上,DBP出水浓度为2.64mg/L,DEHP出水浓度为1.4mg/L,满足《城市污水再生利用地下水回灌水质》(GB/T 19772-2005)的标准.臭氧投加量达到10mg/L时,出水中指示性微生物粪大肠菌群仍接近103CFU/L,5mg/L有效氯消毒后出水粪大肠菌群仍接近10CFU/L,6mg/L臭氧与5mg/L有效氯组合消毒出水的粪大肠菌群下降至3CFU/L,满足《城市污水再生利用景观环境用水水质》(GB/T 18921-2002)的标准.三卤甲烷(THMs)的生成量随着有效氯投加量的增加而增加,臭氧与氯组合消毒过程与氯单独消毒过程相比,THMs生成量减少了78.08%.  相似文献   

9.
MBR工艺在PCB线路板废水处理中的运用   总被引:2,自引:0,他引:2  
巫世文 《环境工程》2008,26(5):68-69
采用MBR工艺对PCB线路板废水进行处理,运行结果表明:在进水COD1500mg/L,Cu2+1.5mg/L,MLSS6000~8000mg/L,DO控制在2~4mg/L,系统温度在20~40℃,停留时间为10h,曝气量在40~43m3/min的污水条件下,MBR系统出水水质良好且运行稳定,COD平均去除率在87%以上,Cu2+平均去除率在70%左右,同时系统具有较强的抗负荷冲击能力。  相似文献   

10.
广州市新星皮革厂污水处理站规模为200m^3/d,采用物化/两级好氧处理工艺,在进水CODCT为2500~3000mg/L。BOD5为1200~1500mg/L,SS为320~600mg/L,pH为6~10,Cr总≤52.7mg/L,Cr^6 ≤5.6mg/L色度约为240倍的条件下,处理后出水水质为CODCT≤80mg/L,BOD≤30mg/L,SS≤70mg/L,pH为6~9,Cr总≤1.2mg/L,Cr^6 ≤0.4mg/L,色度≤40倍。达到了《广州市污水排放标准》(DB44137-90)新扩改一级标准。  相似文献   

11.
IntroductionThedyeingwastewaterofwoolenmillcontainsalotkindsofpollutants,suchasacidicdyes,dispersedyes,mordantdyes,auxiliaries,saltsandsoon .Theeffluentsfromwastewatertreatmentplantsfortreatmentofthedyeingwastewaterofwoolenmillswithnormalbiologicalproce…  相似文献   

12.
An anaerobic/oxic membrane bioreactor (A/O MBR) was used for treatment of dyeing wastewater from a woolen mill.COD and color of the wastewater were 54-473 mg/L and 40-400 dilution time (DT) respectively. The ratio of BOD5/COD was less than 0.13. By the A/O MBR process, the average removal of COD, BOD5, color and turbidity was 82%, 96%, 71% and 99%, respectively. The average COD, BOD5, color and turbidity of effluent was 37 nag/L, 0.8 mg/L, 40 DT and 0.44 NUT respectively. The effluent COD met the local standard of reuse water in Beijing, China. The average COD volume load of the anaerobic biological tank was 0. 0483 kgCOD/(m3·d) and that of the aeration tank of the MBR was 0. 3589 kgCOD/(m3·d). The sludge load of the MBR was 0.19 kgCOD/(kg· MLSS· d) on average and the maximum of that was 0.4 kgCOD/( kg· MLSS· d).The flux of the A/O membrane bioreactor could be remained at larger than 50 L/(h· m2· 0.1MPa). The results indicated that A/O membrane bioreactor has technical feasibility for treatment of woolen mill wastewater.  相似文献   

13.
膜生物反应器与传统活性污泥反应器内生物群落特征   总被引:12,自引:4,他引:8  
欧阳科  刘俊新 《环境科学》2009,30(2):499-503
采用膜生物反应器(MBR)和传统活性污泥法(CAS)2种反应器处理相同的生活污水,考察了MBR和CAS的运行和生物群落结构及其动态变化.结果表明,MBR对COD和氨氮的去除效率均比CAS高, MBR和CAS出水COD的平均值分别为39.6 mg/L和62.9 mg/L,出水氨氮的平均值分别为6.8 mg/L和14.5 mg/L,可以看出无论是对于有机物还是NH+4-N,MBR的去除效果都比CAS要好.由于MBR的污泥处于大的曝气剪切力、过低的污泥负荷、以及长SRT导致的各种惰性物质积累等环境中,使MBR中污泥的群落及其变化与CAS相比有明显的不同.随着反应器运行时间的增加,DGGE的结果表明MBR的种群数量始终高于CAS, MBR群落相似性系数的变化也比CAS要大很多,在第15、 124、 186和230 d时,MBR的条带数分别是22、 25、 24和20条,而CAS在相应的运行时间时条带数分别为19、 14、 17和20条.MBR污泥与种泥的相似性系数分别是54.1%、 63.7%、 63.9%和66.8%,而CAS污泥与种泥的相似性系数分别是71.8%、 61.4%、 9.1%和65.9%.说明CAS的排泥导致非选择性的微生物流失,同时,也说明MBR的群落具有更好的适应环境因素变化的能力,这是MBR抗冲击负荷能力较强的原因之一.从戴丝系数来看,尽管群落相似性越来越高,但群落始终处于变化状态,说明环境的微小变化(进水水质、环境温度等)都会引起生物群落的变化.  相似文献   

14.
针对印染废水含有难降解有机物,处理难度较高,仅通过生化处理难以实现达标排放的特点,对该废水先进行生化处理,经过膜生物反应器(membrane bio-reactor,MBR)系统出水,再采用三相Fenton催化氧化工艺对MBR出水进行处理。结果表明:生化段水力停留时间(hydraulic retention time,HRT)为22h时,MBR出水COD平均值为100.3 mg/L;出水NH3-N、TN、TP均达到GB 18918-2002《污水综合排放标准》一级A标准。调节MBR出水pH=3,H2O2投加量为200 mg/L,FeSO4投加量为200 mg/L条件下,反应HRT为2 h,Fenton催化氧化工艺出水COD为28.1 mg/L,色度为10.8倍,此时Fenton工艺吨水成本为1.01元/t。对进出水的三维荧光分析显示,污水含有较难生化降解的类芳香蛋白质物质,但Fenton催化氧化后仍能被有效分解。从处理效果和处理成本上看,生化处理和Fenton催化氧化组合工艺适宜该印染废水的处理,可为工程应用提供一定的借鉴意义。  相似文献   

15.
气升循环分体式膜生物反应器再生回用厕所污水的研究   总被引:20,自引:0,他引:20  
徐慧芳  樊耀波 《环境科学》2003,24(2):125-129
研究了分体浸没式膜生物反应器及其应用于厕所污水的再生回用.试验结果表明,在人水浓度COD440~970mg/L、BOD5 307~612mg/L、NH3-N59~111mg/L的情况下,出水水质稳定,平均COD<47mg/L、BOD5<8.5mg/L、NH3-N<20mg/L,处理水质达到建设部颁布的生活杂用水回用标准.研究了动力学参数污泥负荷、容积负荷和HRT对出水COD的影响,确定本试验较佳的污泥负荷和容积负荷分别为0.1kg/(kg·d)和1kg/(m3·d),HRT为7~8h.本文对污泥浓度、温度和产水时间与间歇时间比对膜通量的影响进行了测定与探讨.  相似文献   

16.
为了考察投加颗粒活性炭(GAC)对膜生物反应器(MBR)运行过程和处理效果的影响,研究了MBR和GAC-MBR透膜压差、膜通量的变化情况和脱氮性能,并采用ASM1模型对2个反应器进行数学模拟.结果表明,MBR和GAC-MBR的运行周期分别为75,150h,说明GAC的加入能够显著减缓MBR膜污染的速度,延长MBR的运行周期.MBR和GAC-MBR氨氮浓度分别为0.5,6mg/L;硝氮浓度分别为4.5,2mg/L;总氮浓度分别为5,10mg/L,出水COD均低于20mg/L,出水能符合《城镇污水处理厂污染物排放标准(GB 18918-2002)》中的一级A标准.采用ASM1进行工艺数学模拟,模拟出水与实际测量值基本吻合,2个反应器中主要微生物为异养菌和氨氧化菌,异养菌在MBR和GAC-MBR中的质量分数分别为95.5%和97.7%;好氧氨氧化菌分别为4.4%和2.3%,说明投加颗粒活性炭能有效的缓解膜污染,并对污染物具有良好的处理效果.  相似文献   

17.
为了加快平板膜-生物反应器的工程化应用步伐,以上海白龙港水质净化厂400 t/d的示范工程为依托,对平板膜-生物反应器的污染物去除效果、膜污染情况和清洗效果等进行了研究。平板膜-生物反应器的出水COD在20 mg/L左右,浊度小于5 NTU,氨氮小于5 mg/L,基本满足杂用水水质标准(GB/T18920-2002),可以回用作厂区内冲厕和绿化用水等。正交实验结果表明,对在线清洗效果影响较大的因素是曝气量和清洗点的跨膜压力,影响较小的是清洗时间;跨膜压力为45 kPa,停抽时间为2 h,曝气量为100 m3/h为在线清洗的最佳操作条件。  相似文献   

18.
膜生物反应器处理印染废水技术研究   总被引:5,自引:1,他引:5  
采用小试规模(148L/d)的厌氧-好氧膜生物反应器处理印染废水.当水力停留时间为14小时,进水COD、色度分别为208.54~2592.00mg/l、32~256倍,通过水解酸化-体式膜生物反应器试验,系统对COD、色度的去除率分别达到了80%~90%、87.5%.出水水质浓度或指标分别为21.80~363.20mg/l、8倍,具有良好的处理效果.厌氧-好氧膜生物反应器工艺处理印染废水技术可行、操作简单、易于管理、可为工业规模应用提供技术参考.  相似文献   