首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes results from a pilot study of a novel wastewater treatment technology, which incorporates nutrient removal and solids separation to a single step. The pseudoliquified activated sludge process pilot system was tested on grit removal effluent at flowrates of 29.4 to 54.7 m3/d, three different solid residence times (SRT) (15, 37, and 57 days), and over a temperature range of 12 to 28 degrees C. Despite wide fluctuations in the influent characteristics, the system performed reliably and consistently with respect to organics and total suspended solids (TSS) removals, achieving biochemical oxygen demand (BOD) and TSS reductions of > 96% and approximately 90%, respectively, with BOD5 and TSS concentrations as low as 3 mg/L. Although the system achieved average effluent ammonia concentrations of 2.7 to 3.2 mg/L, nitrification efficiency appeared to be hampered at low temperatures (< 15 degrees C). The system achieved tertiary effluent quality with denitrification efficiencies of 90 and 91% total nitrogen removal efficiency at a total hydraulic retention time of 4.8 hours and an SRT of 12 to 17 days. With ferric chloride addition, effluent phosphorous concentrations of 0.5 to 0.8 mg/L were achieved. Furthermore, because of operation at high biomass concentrations and relatively long biological SRTs, sludge yields were over 50% below typical values for activated sludge plants. The process was modeled using activated sludge model No. 2, as a two-stage system comprised an aerobic activated sludge system followed by an anoxic system. Model predictions for soluble BOD, ammonia, nitrates, and orthophosphates agreed well with experimental data.  相似文献   

2.
This work evaluated the performance of a full-scale system with wetlands for slaughterhouse (abattoir) effluent treatment in the State of Hidalgo, México. The treatment system consisted of a primary sedimentation tank, an anaerobic lagoon, and a constructed subsurface-flow wetland, in series. The wetland accounted for almost 30% of the removal of organic matter. In general, the treatment system achieved satisfactory pollutant removals, but the final effluent could not meet the Mexican environmental regulations for fecal coliform counts, five-day biochemical oxygen demand (BOD5), and total suspended solids (TSS). Overall, removal levels were 91%, 89%, and 85% for BOD5, chemical oxygen demand, and TSS, respectively. However, BOD5 in the final effluent (137 mg/L) was higher than the maximum level of 30 mg/L allowed by the regulatory agency. Although organic nitrogen removal levels were approximately 80%, the nitrogen persisted in oxidation state -3 as ammonia-nitrogen, the removal of which was only 9% in the wetland stage. On average, phosphorus removal was null, and, on occasion, the phosphorus concentration in the treated effluent was higher than that of the influent. Coliform reductions in the overall system were high (on the order of 5 logs on average), whereas the coliform removal in the wetland was between 2 to 3.5 logs. The treatment system was also effective at removing pathogens (Vibrio cholerae, Salmonella, and Shigella). Further laboratory tests with the wetland effluent suggest that post treatment in a sand filter stage followed by disinfection with sodium hypochlorite (NaOCl) could help meet the Mexican discharge regulations, particularly the criteria for coliforms and total BOD5.  相似文献   

3.
Enzymatic treatment of sanitary landfill leachate   总被引:2,自引:0,他引:2  
The objective of this investigation was to study the effectiveness of applying enzymes (bioaugmentation) for enhancement of biological treatability of leachates generated in a typical municipal solid waste sanitary landfill. The basic purpose of enzyme use is to enforce the biodecomposition of organic constituents, as well as to reduce nitrogen content. A laboratory-scale sequencing batch (bio)reactor (SBR) was used for the examination of enzymatic application. The effect of different operation strategies on the efficiency of this biological treatment process was studied to optimize performance, especially for the removal of nitrogen compounds and of biodegradable organic matter. It was found that the enzymatic process was able to remove organic matter effectively (expressed as BOD5 and COD) and nitrogen content, color and turbidity.  相似文献   

4.
The main objective of this study was to investigate the feasibility of coagulation as a post-treatment method of anaerobically treated primary municipal wastewater. Both mesophilic and ambient (20 degrees C) temperature conditions were investigated in a laboratory-scale upflow anaerobic sludge bed (UASB) reactor. In addition, optimization of the coagulant, both in terms of type and dose, was performed. Finally, phosphorus removal by means of aluminum and iron coagulation and phosphorus and ammonia nitrogen removal by means of struvite precipitation were studied. Anaerobic treatment of primary effluent at low hydraulic retention times (less than 15 hours) resulted in mean chemical oxygen demand (COD) removals ranging from 50 to 70%, while, based on the filtered treated effluent, the mean removals increased to 65 to 80%. Alum coagulation of the UASB effluent gave suspended solids removals ranging from approximately 35 to 65%. Turbidity removal reached up to 80%. Remaining COD values after coagulation and settling were below 100 mg/L, while remaining total organic carbon (TOC) levels were below 50 mg/L. Filterable COD levels were generally below 60 mg/L, while filterable TOC levels were below 40 mg/L. All coagulants tested, including prepolymerized aluminum and iron coagulants, demonstrated similar efficiency compared with alum for the removal of suspended solids, COD, and TOC. Regarding struvite precipitation, optimal conditions for phosphorus and nitrogen removal were pH 10 and molar ratio of magnesium: ammonia-nitrogen: phosphate-phosphorus close to the stoichiometric ratio (1:1:1). During struvite precipitation, removal of suspended solids reached 40%, while turbidity removal reached values up to 80%. The removal of COD was approximately 30 to 35%; yet, when removal of organic matter was based on the treated filterable COD, the removal increased to approximately 65%. In addition, nitrogen was removed by approximately 70%, while phosphorus removal ranged between approximately 30 and 45% on the basis of the initial phosphorus concentration. Finally, size fractionation of the organic matter (COD) showed that the various treatment methods were capable of removing different fractions of the organic matter.  相似文献   

5.
The objective of this investigation was to compare two biological systems using attached-growth biomass, for treatment of leachates generated in a typical municipal solid waste sanitary landfill. A moving-bed biofilm process, which is a relatively new type of biological treatment system, has been examined. It is based on the use of small, free-floating polymeric (polyurethane) elements, while biomass is being grown and attached as biofilm on the surface of these porous carriers. A granular activated carbon (GAC) moving-bed biofilm process was also tested. This method combines both physico-chemical and biological removal mechanisms for the removal of pollutants. The presence of GAC offers a suitable porous media, which is able to adsorb both organic matter and ammonia, as well as to provide an appropriate surface onto which biomass can be attached and grown. A laboratory-scale sequencing batch reactor (SBR) was used for the examination of both carriers. The effects of different operation strategies on the efficiency of these biological treatment processes were studied in order to optimize their performance, especially for the removal of nitrogen compounds and of biodegradable organic matter. It has been found that these processes were able to remove nitrogen content almost completely and simultaneously, the removal of organic matter (expressed as BOD5 and COD), color and turbidity were sufficiently achieved.  相似文献   

6.
Moon HB  Yoon SP  Jung RH  Choi M 《Chemosphere》2008,73(6):880-889
Toxic organic contaminants and a macrobenthic community were assayed in sediments collected near a wastewater treatment plant (WWTP) outfall to assess the impact of WWTP discharges on an aquatic environment. Average concentrations of toxic organic contaminants in sediments from 20 locations were 96.7ng TEQ/kg dry matter for PCDD/Fs, 1.84ng TEQ/kg dry matter for dioxin-like PCBs, 29.1microg/kg dry matter for PBDEs, 411microg/kg dry matter for nonylphenols, 1021microg/kg dry matter for fecal sterols, and 928microg/kg dry matter for PAHs. Concentrations of all the organic contaminants and fecal sterols varied widely and there was a clear decrease in concentration gradients with increasing distances from the WWTP outfall. This result suggests that WWTP activities contribute to contamination by organic chemicals. A survey of benthic organisms showed the dominance of a few polychaete species, indicating a deterioration of the macrobenthic community by the WWTP discharge. Non-parametric multidimensional scaling (MDS) ordination and Spearman correlation analyses showed that organic contamination is associated with the benthic community structure. For polychaete species, the sensitive species for organic contaminants was Paraprionospio pinnata, while contaminant-tolerant species were Spiochaetopterus koreana and Capitella capitata. BIOENV analyses of all locations suggested PCDDs and PCDFs as the major contaminants influencing the structure of the macrobenthic community. The present study highlights that continuous WWTP discharges contribute to severe organic contamination and risks for the benthic community in an aquatic ecosystem.  相似文献   

7.
生物填料地下渗滤系统对生活污水的脱氮   总被引:1,自引:0,他引:1  
将草甸棕壤、炉渣和活性污泥等基质按体积比13∶6∶1配制生物填料,研究了生物填料地下渗滤系统(subsurface wastewater infiltration system,SWIS)在不同的水力负荷和污染负荷条件下对校园生活污水的脱氮效果。场地实验结果表明,当BOD5负荷为12.0 g BOD5/(m2·d),表面水力负荷为0.04-0.10 m3/(m2·d)时,SWIS对NH+4-N和TN的平均去除率分别为92.4%和82.0%。当水力负荷为0.08 m3/(m2·d),BOD5负荷9.3-16.8 g BOD5/(m2·d)时,SWIS对NH+4-N和TN的平均去除率为92.7%和81.2%。SWIS中氧化还原电位(oxygen reduction potential,ORP)随进水水力负荷和BOD5负荷的增加而降低,脱氮效率下降。综合出水水质和处理效率,适宜的水力负荷和污染负荷分别为0.065 m3/(m2·d)和12.0 g BOD5/(m2·d)。在此条件下,SWIS的启动周期为25-30 d。出水水质均优于《城市污水再生利用-景观环境用水水质》(GB/T18921-2002)标准,且处理效果稳定,抗负荷冲击能力强。  相似文献   

8.
Kim Y  Tanaka K  Lee YW  Chung J 《Chemosphere》2008,70(6):990-1001
An up-flow biological anoxic filter (BANF) has been developed to achieve high removal performance of suspended solids and BOD removal as well as nitrogen. With a view to understand treatment mechanisms, we developed a filtration model that incorporates filtration, deposit scoring and biological reactions simultaneously. The biological reactions consist of four types of reaction; dissolution of organic particles; utilization of dissolved organic matter; denitrification; and self-degradation of bacteria. Whereas the reactor is generally assumed to be a plug flow reactor in the filtration model, it is assumed a continuous-flow stirred tank reactor (CSTR) in the model of biological reactions. The hydrodynamics is supposed that the filter bottom (the portion sludge settled) is a CSTR and the filter bed (the portion filled with filter media) consists of number of CSTR of equal size arranged in series. The model obtained in this study was verified and simulated using experimental results taken from a pilot-scale plant and predicted the experimental data well, applying to design and operate BANF.  相似文献   

9.
分段进水多级生物膜反应器脱氮效能影响因素研究   总被引:2,自引:1,他引:1  
采用分段进水多级生物膜反应器处理高氮低碳小城镇污水,考察负荷、溶解氧和温度对反应器脱氮效能的影响。实验结果表明:负荷、溶解氧和温度对反应器脱氮效能有显著影响。在水温为20~25℃,DO为5 mg/L,负荷为1 kgCOD/(m3.d),挂膜密度为30%,第1、3、6级分段进水,流量分配比为2∶2∶1的条件下,在反应器中可成功构建出高效同时硝化反硝化系统,出水COD、NH4+-N和TN浓度分别为33 mg/L、2.6 mg/L和29.4 mg/L,去除率分别为90.1%、96.0%和63.9%。当水温≤15℃时,硝化速率受温度的影响显著。  相似文献   

10.
采用膨胀颗粒污泥床(EGSB)反应器对城市生活垃圾焚烧厂产生的垃圾沥滤液进行处理。实验结果表明:中温条件下,当COD浓度为55 000 mg/L左右,有机容积负荷(OLR)为22.8 kg COD/(m3.d)时,EGSB对垃圾沥滤液具有较好的的处理效果,COD去除率可达94.2%。当进水COD为72 000 mg/L左右时,为保证反应器的稳定运行,OLR应降低至18.2 kg COD/(m3.d),此时COD去除率可以达到88%左右,出水COD平均为9 103 mg/L。垃圾沥滤液和EGSB处理出水均以小分子量有机物为主,其中<4 kDa的有机物分别占76.5%和74.4%。EGSB对整个分子量区间的溶解性有机物都有较好的处理效果,其中对大分子有机物的处理效率相对更高。  相似文献   

11.
Wen CG  Chen TH  Hsu FH  Lu CH  Lin JB  Chang CH  Chang SP  Lee CS 《Chemosphere》2007,67(8):1588-1600
The objectives of this paper are to determine effects of different grass species and their harvests on pollutant removal, elucidate impacts on soil characteristics and grass constituents, observe grass yield and quantify nutrient uptake by vegetation in an overland flow system (OLFS). Polluted creek water was applied to eight channels in the OLFS, which were planted with Paragrass, Nilegrass, Cattail, and Vetiver, with each two channels being randomly planted with a given grass species. The grass in one channel was harvested while that in the other channel was not. At a high rate of 27.8 m d(-1) hydraulic loading, the removal efficiencies of conventional pollutants such as BOD, COD, suspended solids (SS), and total coliforms in wastewater are not affected by the type of the grasses species, but those of nitrogen and phosphorus are affected by different species. Overall average removal efficiencies of BOD, COD, SS, ammonia, total nitrogen, total phosphorus and total coliforms through the OLFS are 42%, 48%, 78%, 47%, 40%, 33% and 89%, respectively. The concentration of nitrate, however, increases due to nitrification. Soil characteristics in OLFS have been changed significantly; specific conductivity, organic matter, exchangeable magnesium, extractable copper and zinc in soils all increase with time while pHs decrease. During the winter season, there is a significant accumulation of nitrate in grass with the subsequent reduction during the active growing season (Spring). The contents of nitrate and phosphorus in grass tissue are higher than those of grass in general pastureland, probably due to nutrient luxury uptake by grass. The overall grass yield, growth rate and nutrient uptake are quantified and implication of such high rate OLFS discussed.  相似文献   

12.
Simultaneous nitrification-denitrification (SND) of municipal wastewater was investigated in a laboratory-scale membrane bioreactor (MBR) operated at two different hydraulic retention times (HRTs), 0.5 and 1 day, dissolved oxygen 3.0 to 0.5 mg/L, and solids retention time (SRT) between 28 and 120 days. The organic loading rate (OLR) (0.11 to 0.64 kg chemical oxygen demand [COD]/m3/d) and influent soluble COD (SCOD)/ total Kjeldahl nitrogen (TKN) ratio (5 to 19) were varied by the addition of glucose. The ammonia-nitrogen and TKN removals were over 97%, and total nitrogen removal was approximately 89% in the MBR. The maximum specific nitrification rates (98 mg N/d/g VSS) and specific denitrification rates (81 mg N/d/g VSS) occurred at an SCOD/TKN ratio of 9.1. The optimum conditions for maximum total nitrogen removal by SND in a single reactor MBR have been found to be low dissolved oxygen (< 0.6 mg/L) and high OLR (approximately 0.64 kg COD/m3/d) at an HRT of 0.5 day and SRT of approximately 85 days.  相似文献   

13.
Chowdhury N  Nakhla G  Zhu J 《Chemosphere》2008,71(5):807-815
A novel liquid-solid circulating fluidized bed bioreactor (LSCFB) configured with anoxic and aerobic columns and lava rock as the biofilm carrier was used to treat synthetic municipal wastewater. Four different empty bed contact times (EBCTs) of 0.82, 0.65, 0.55, and 0.44 h were examined to optimize nutrient removal capability of the system. The LSCFB demonstrated tertiary effluent quality organic and nitrogen removal efficiencies. Effluent characteristics of the LSCFB were soluble biological oxygen demand (SBOD)10 mg l(-1) and total nitrogen (TN)<10 mg l(-1) at organic loading rate (OLR) of 5.3 kg m(-3)d(-1) and nitrogen loading rate of 0.54 kg Nm(-3)d(-1). Remarkably low yields of 0.14, 0.17, 0.19, and 0.21 g VSS g(-1)COD were observed at OLR of 2.6, 3.2, 4.1 and 5.3 kg COD m(-3)d(-1), where increment of biomass growth and detachment rate were also experienced with increasing OLR. However the system demonstrated only 30% phosphorus removal, and mass balances along the anoxic and aerobic columns showed biological phosphorus removal in the system. Organic mass balance showed that approximately 40% of the influent COD was utilized in the anoxic column and the remaining COD was oxidized in the aerobic column. The system is very efficient in nitrification-denitrification, with more than 90% nitrification of ammonium and overall nitrogen removal in the LSCFB was 70+/-11% even at an EBCT of 0.44 h.  相似文献   

14.
An upflow anaerobic sludge blanket (UASB)-anoxicaerobic system was used for treatment of tomato and bean processing wastewater. At various hydraulic retention times, ranging from 0.7 to 5 days, excellent removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia-nitrogen (NH4-N), and total Kjeldahl nitrogen was achieved with final effluent BOD/TSS/NH4N concentrations of less than 15/15/1 mg/L. Biogas yield in the UASB reactor varied from 0.33 to 0.44 m3/kgCODremoved. The kinetics of anaerobic treatment were investigated. The yield coefficient was 0.03 gVSS/gCOD; maximum specific growth rate was 0.24 day(-1); Monod half velocity constant was 135 mgCOD/L; and specific substrate utilization rate was 3.25 gCOD/gVSS x d. Nitrification and denitrification kinetics were studied in batch experiments, and the rates were comparable with those in the continuous flow system.  相似文献   

15.
Banat FA  Prechtl S  Bischof F 《Chemosphere》1999,39(12):2097-2106
The reduction of organic contaminants in sewage sludge is of great importance for a further sludge disposal or agricultural utilization. Laboratory scale batch experiments were performed to assess the potential use of the aerobic thermophilic treatment technique to reduce the concentration of difficult to degrade organic chemicals. Di-2-ethylhexyl phthalate (DEHP) was chosen as a model representative of these chemicals. The effect of the sludge temperature and aeration rate on the reduction of DEHP concentration as well as on the reduction of the organic dry solid (oDS) was investigated. With a specific air flow rate of 16 m3/m3.h and a thermophilic temperature of 63 degrees C it was possible to achieve up to 70% reduction of the DEHP concentration and 61% of oDS within 96 hours. The maximum degradation of the oDS matter occurred within the first 24 hours of operation whereby only little oDS was degraded afterward. During the experiments the reactor content was routinely monitored for pH, COD, along with the ammonia nitrogen and orthophosphate concentrations.  相似文献   

16.
The purification capacity of the contact stabilisation system at Birzeit University campus has been studied for two years. The oxidation capacity of organic matter, ammonium oxidation, and denitrification potential were determined. The reduction of chemical oxygen demand (COD) was 85%, and the effluent COD concentration was less than 110 mg/l (the average value was 88 mg/l). Suspended solids were removed with equal efficiency. The aerobic stabilization of organic solids was efficient, and no excess biosolids (sludge) had to be removed. High nitrification (70% of the influent nitrogen were nitrified) could be maintained at 15°C, and 42% of the oxidised nitrogen was denitrified. The specific oxygenation capacity of the treatment system is relatively high and reached about 5 kwh/kg COD. The specific wastewater treatment cost is about 0.52 US$/m3 or about 58 US$ per population equivalent per year. Based on the results obtained, batch operation and intermittent aeration of the biological process are suggested to achieve high effluent quality and to reduce power consumption.  相似文献   

17.
以复合人工湿地工程实例为研究对象,研究了其在连续5个月内对低浓度有机污染物的深度处理效果,采用简化的Monod动力学模型对研究湿地进行模拟并验证,讨论了污染负荷与去除率的相关性以及BOD/COD比值对有机污染物降解系数的影响。研究湿地总面积为5 000 m2,进水水量为860~1 560 m3/d,水力停留时间为1.48~2.69 d,水力负荷为0.17~0.31 m/d,进水中有机污染物浓度较低(BOD53.0~25.6 mg/L;COD 22.9~89.8 mg/L)。结果表明,复合湿地组合形式对BOD5和COD的去除率分别介于37.9%~79.0%和41.0%~68.7%之间,简化的Monod模型对湿地中BOD5和COD去除的预测值与实验观测值吻合程度较好;BOD5、COD的去除率分别随着进水BOD5和COD浓度的增加而增大,而增长趋势逐渐变缓,当有机污染负荷低时,模型的K值较小;低浓度有机污染物在VSF、FWS和HSF湿地中的去除效率与有机物是否容易或者缓慢被微生物降解的性质相关性较差,这可能与人工湿地中存在的其他因素促进了有机污染物的去除有关。  相似文献   

18.
研发了一种基于射流曝气的管式反应设备,考察了负荷和DO对反应器处理效能的影响。实验结果表明,在温度为15℃、DO 6.0 mg/L、有机负荷为1.0 kg COD/(m3.d)、氮负荷为0.30 kg TN/(m3.d)、HRT为8 h的条件下,管式反应器可使生活污水的COD、NH4+-N及TN分别从335 mg/L、105 mg/L及110 mg/L降至43 mg/L、14 mg/L及18 mg/L,去除率分别为87%、86%和83%。DO对反应器脱氮效能影响显著,DO为6 mg/L时,能构建出同步硝化反硝化系统,NH4+-N和TN的去除率分别为96.6%和86.7%。  相似文献   

19.
In this study, high-solids anaerobic digestion of thermally pretreated wastewater solids (THD) was compared with conventional mesophilic anaerobic digestion (MAD). Operational conditions, such as pretreatment temperature (150 to 170 degrees C), solids retention time (15 to 20 days), and digestion temperature (37 to 42 degrees C), were varied for the seven THD systems operated. Volatile solids reduction (VSR) by THD ranged from 56 to 62%, compared with approximately 50% for MAD. Higher VSR contributed to 24 to 59% increased biogas production (m3/kg VSR-d) from THD relative to MAD. The high-solids conditions of the THD feed resulted in high total ammonia-nitrogen (proportional to solids loading) and total alkalinity concentrations in excess of 14 g/L as calcium carbonate (CaCO3). Increased pH in THD reactors caused 5 to 8 times more un-ionized ammonia to be present than in MAD, and this likely led to inhibition of aceticlastic methanogens, resulting in accumulation of residual volatile fatty acids between 2 and 6 g/L as acetic acid. The THD produced biosolids cake that possessed low organic sulfur-based biosolids odor and dewatered to between 33 and 39% total solids. Dual conditioning with cationic polymer and ferric chloride was shown to be an effective strategy for mitigating dissolved organic nitrogen and UV-quenching compounds in the return stream following centrifugal dewatering of THD biosolids.  相似文献   

20.
新型人工快速渗滤系统处理村镇污水工艺参数优化   总被引:1,自引:1,他引:0  
在巢湖双桥河建立了中试规模的人工快速渗滤系统(CRI),系统经过一个月左右启动期后挂膜成功。通过考察不同湿干比条件下CODMn、TP、TN和NH3-N的去除效果,确定系统湿干比为1 d∶2 d,水力负荷周期为3 d。TP、TN和NH3-N在1.0 m/d的水力负荷条件下能够达到最佳的处理效果,特别是TN;而CODMn在1.3 m/d取得最佳的去除效果。综合考虑脱氮除磷和有机污染物的去除,选取水力负荷为1.0 m/d可得到最佳的出水水质。综合4种污染物的去除特点,特别考虑到对TN去除的需要,同时兼顾工程成本,填料厚度确定为1.2~1.5 m之间为最佳。选取生物陶粒、钢渣、活性炭和天然沸石为渗滤介质,研究结果表明,从去除有机污染物和TP角度考虑,选取活性炭和钢渣可达到较好的去除效果,其中钢渣对TP去除效果更佳;而活性炭具有其他4种填料不可替代的脱氮效果。以上工艺组合形式的确定将为巢湖流域CRI系统的推广提供科学依据和数据支持。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏