首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wellbore integrity is one of the key performance criteria in the geological storage of CO2. It is significant in any proposed storage site but may be critical to the suitability of depleted oil and gas reservoirs that may have 10’s to 1000’s of abandoned wells. Much previous work has focused on Portland cement which is the primary material used to seal wellbore systems. This work has emphasized the potential dissolution of Portland cement. However, an increasing number of field studies (e.g., Carey et al., 2007), experimental studies (e.g., Kutchko et al., 2006) and theoretical considerations indicate that the most significant leakage mechanism is likely to be flow of CO2 along the casing–cement microannulus, cement–cement fractures, or the cement–caprock interface.In this study, we investigate the casing–cement microannulus through core-flood experiments. The experiments were conducted on a synthetic wellbore system consisting of a 5-cm diameter sample of cement that was cured with an embedded rectangular length of steel casing that had grooves to accommodate fluid flow. The experiments were conducted at 40 ° C and 14 MPa pore pressure for 394 h. During the experiment, 6.2 l of a 50:50 mixture of supercritical CO2 and 30,000 ppm NaCl-rich brine flowed through 10-cm of limestone before flowing through the 6-cm length cement–casing wellbore system. Approximately 59,000 pore volumes of fluid moved through the casing–cement grooves. Scanning electron microscopy revealed that the CO2–brine mixture impacted both the casing and the cement. The Portland cement was carbonated to depths of 50–250 μm by a diffusion-dominated process. There was very little evidence for mass loss or erosion of the Portland cement. By contrast, the steel casing reacted to form abundant precipitates of mixed calcium and iron carbonate that lined the channels and in one case almost completely filled a channel. The depth of steel corroded was estimated at 25– 30μm and was similar in value to results obtained with a simplified corrosion model.The experimental results were applied to field observations of carbonated wellbore cement by Carey et al. (2007) and Crow et al. (2009) to show that carbonation of the field samples was not accompanied by significant CO2–brine flow at the casing–cement interface. The sensitivity of standard-grade steel casing to corrosion suggests that relatively straight-forward wireline logging of external casing corrosion could be used as a useful indicator of flow behind casing. These experiments also reinforce other studies that indicate rates of Portland cement deterioration are slow, even in the high-flux CO2–brine experiments reported here.  相似文献   

2.
Long-term integrity of existing wells in a CO2-rich environment is essential for ensuring that geological sequestration of CO2 will be an effective technology for mitigating greenhouse gas-induced climate change. The potential for wellbore leakage depends in part on the quality of the original construction as well as geochemical and geomechanical stresses that occur over its life-cycle. Field data are essential for assessing the integrated effect of these factors and their impact on wellbore integrity, defined as the maintenance of isolation between subsurface intervals. In this report, we investigate a 30-year-old well from a natural CO2 production reservoir using a suite of downhole and laboratory tests to characterize isolation performance.These tests included mineralogical and hydrological characterization of 10 core samples of casing/cement/formation, wireline surveys to evaluate well conditions, fluid samples and an in situ permeability test. We find evidence for CO2 migration in the occurrence of carbonated cement and calculate that the effective permeability of an 11′-region of the wellbore barrier system was between 0.5 and 1 milliDarcy. Despite these observations, we find that the amount of fluid migration along the wellbore was probably small because of several factors: the amount of carbonation decreased with distance from the reservoir, cement permeability was low (0.3–30 microDarcy), the cement–casing and cement-formation interfaces were tight, the casing was not corroded, fluid samples lacked CO2, and the pressure gradient between reservoir and caprock was maintained. We conclude that the barrier system has ultimately performed well over the last 3 decades. These results will be used as part of a broader effort to develop a long-term predictive simulation tool to assess wellbore integrity performance in CO2 storage sites.  相似文献   

3.
Idealized, basin-scale sharp-interface models of CO2 injection were constructed for the Illinois basin. Porosity and permeability were decreased with depth within the Mount Simon Formation. Eau Claire confining unit porosity and permeability were kept fixed. We used 726 injection wells located near 42 power plants to deliver 80 million metric tons of CO2/year. After 100 years of continuous injection, deviatoric fluid pressures varied between 5.6 and 18 MPa across central and southern part of the Illinois basin. Maximum deviatoric pressure reached about 50% of lithostatic levels to the south. The pressure disturbance (>0.03 MPa) propagated 10–25 km away from the injection wells resulting in significant well–well pressure interference. These findings are consistent with single-phase analytical solutions of injection. The radial footprint of the CO2 plume at each well was only 0.5–2 km after 100 years of injection. Net lateral brine displacement was insignificant due to increasing radial distance from injection well and leakage across the Eau Claire confining unit. On geologic time scales CO2 would migrate northward at a rate of about 6 m/1000 years. Because of paleo-seismic events in this region (M5.5–M7.5), care should be taken to avoid high pore pressures in the southern Illinois basin.  相似文献   

4.
Using a combination of experimental (petrophysical and mineralogical) methods, the effects of high-pressure CO2 exposure on fluid transport properties and mineralogical composition of two pelitic caprocks, a limestone and a clay-rich marl lithotype have been studied. Single and multiphase permeability tests, gas breakthrough and diffusion experiments were conducted under in situ p/T conditions on cylindrical plugs (28.5 mm diameter, 10–20 mm thickness).The capillary CO2 sealing efficiency of the initially water-saturated sample plugs was found to decrease in repetitive gas breakthrough experiments on the same sample from 0.74 to 0.41 MPa for the limestone and from 0.64 to 0.43 MPa for the marl. Helium breakthrough experiments before and after the CO2 tests showed a decrease in capillary threshold (snap-off) pressure from 1.81 to 0.62 MPa for the limestone.Repetitive CO2 diffusion experiments on the marlstone revealed an increase in the effective diffusion coefficient from 7.8 × 10?11 to 1.2 × 10?10 m2.Single-phase (water) permeability coefficients derived from steady-state permeability tests ranged between 7 and 56 nano-Darcy and showed a consistent increase after each CO2 test cycle. Effective gas permeabilities were generally one order of magnitude lower than water permeabilities and exhibit the same trend. XRD measurements performed before and after exposure to CO2 did not reveal any distinct change in the mineral composition for both samples. Similarly, no significant changes were observed in specific surface areas (determined by BET) and pore-size distributions (determined by mercury injection porosimetry). High-pressure CO2 sorption experiments on powdered samples revealed significant CO2 sorption capacities of 0.27 and 0.14 mmol/g for the marlstone and the limestone, respectively.The changes in transport parameters in the absence of detectable mineral alterations may be explained by carbonate dissolution and further precipitation along a pH profile across the sample plug which would not be subject to quantitative mineral alteration.  相似文献   

5.
Methodology is presented for a first-order regional-scale estimation of CO2 storage capacity in coals under sub-critical conditions, which is subsequently applied to Cretaceous-Tertiary coal beds in Alberta, Canada. Regions suitable for CO2 storage have been defined on the basis of groundwater depth and CO2 phase at in situ conditions. The theoretical CO2 storage capacity was estimated on the basis of CO2 adsorption isotherms measured on coal samples, and it varies between ∼20 kt CO2/km2 and 1260 kt CO2/km2, for a total of approximately 20 Gt CO2. This represents the theoretical storage capacity limit that would be attained if there would be no other gases present in the coals or they would be 100% replaced by CO2, and if all the coals will be accessed by CO2. A recovery factor of less than 100% and a completion factor less than 50% reduce the theoretical storage capacity to an effective storage capacity of only 6.4 Gt CO2. Not all the effective CO2 storage capacity will be utilized because it is uneconomic to build the necessary infrastructure for areas with low storage capacity per unit surface. Assuming that the economic threshold to develop the necessary infrastructure is 200 kt CO2/km2, then the CO2 storage capacity in coal beds in Alberta is greatly reduced further to a practical capacity of only ∼800 Mt CO2.  相似文献   

6.
In order to develop subsurface CO2 storage as a viable engineered mechanism to reduce the emission of CO2 into the atmosphere, any potential leakage of injected supercritical CO2 (SC-CO2) from the deep subsurface to the atmosphere must be reduced. Here, we investigate the utility of biofilms, which are microorganism assemblages firmly attached to a surface, as a means of reducing the permeability of deep subsurface porous geological matrices under high pressure and in the presence of SC-CO2, using a unique high pressure (8.9 MPa), moderate temperature (32 °C) flow reactor containing 40 millidarcy Berea sandstone cores. The flow reactor containing the sandstone core was inoculated with the biofilm forming organism Shewanella fridgidimarina. Electron microscopy of the rock core revealed substantial biofilm growth and accumulation under high-pressure conditions in the rock pore space which caused >95% reduction in core permeability. Permeability increased only slightly in response to SC-CO2 challenges of up to 71 h and starvation for up to 363 h in length. Viable population assays of microorganisms in the effluent indicated survival of the cells following SC-CO2 challenges and starvation, although S. fridgidimarina was succeeded by Bacillus mojavensis and Citrobacter sp. which were native in the core. These observations suggest that engineered biofilm barriers may be used to enhance the geologic sequestration of atmospheric CO2.  相似文献   

7.
Studies of the kinetics of sulfur dioxide (SO2)- and oxygen (O2)-induced degradation of aqueous monoethanolamine (MEA) during the absorption of carbon dioxide (CO2) from flue gases derived from coal- or natural gas-fired power plants were conducted as a function of temperature and the liquid phase concentrations of MEA, O2, SO2 and CO2. The kinetic data were based on the initial rate which shows the propensity for amine degradation and obtained under a range of conditions typical of the CO2 absorption process (3–7 kmol/m3 MEA, 6% O2, 0–196 ppm SO2, 0–0.55 CO2 loading, and 328–393 K temperature). The results showed that an increase in temperature and the concentrations of MEA, O2 and SO2 resulted in a higher MEA degradation rate. An increase in CO2 concentration gave the opposite effect. A semi-empirical model based on the initial rate, ?rMEA = {6.74 × 109 e?(29,403/RT)[MEA]0.02([O]2.91 + [SO2]3.52)}/{1 + 1.18[CO2]0.18} was developed to fit the experimental data. With the higher order of reaction, SO2 has a higher propensity to cause MEA to degrade than O2. Unlike previous models, this model shows an improvement in that any of the parameters (i.e. O2, SO2, and CO2) can be removed without affecting the usability of the model.  相似文献   

8.
Mathematical tools are needed to screen out sites where Joule–Thomson cooling is a prohibitive factor for CO2 geo-sequestration and to design approaches to mitigate the effect. In this paper, a simple analytical solution is developed by invoking steady-state flow and constant thermophysical properties. The analytical solution allows fast evaluation of spatiotemporal temperature fields, resulting from constant-rate CO2 injection. The applicability of the analytical solution is demonstrated by comparison with non-isothermal simulation results from the reservoir simulator TOUGH2. Analysis confirms that for an injection rate of 3 kg s?1 (0.1 MT yr?1) into moderately warm (>40 °C) and permeable formations (>10?14 m2 (10 mD)), JTC is unlikely to be a problem for initial reservoir pressures as low as 2 MPa (290 psi).  相似文献   

9.
A laboratory-scale reactor system was built and operated to demonstrate the feasibility of catalytically reacting carbon dioxide (CO2) with renewably-generated hydrogen (H2) to produce methane (CH4) according to the Sabatier reaction: CO2 + 4H2  CH4 + 2H2O. A cylindrical reaction vessel packed with a commercial methanation catalyst (Haldor Topsøe PK-7R) was used. Renewable H2 produced by electrolysis of water (from solar- and wind-generated electricity) was fed into the reactor along with a custom blend of 2% CO2 in N2, meant to represent a synthetic exhaust mixture. Reaction conditions of temperature, flow rates, and gas mixing ratios were varied to determine optimum performance. The extent of reaction was monitored by real-time measurement of CO2 and CH4. Maximum conversion of CO2 occurred at 300–350 °C. Approximately 60% conversion of CO2 was realized at a space velocity of about 10,000 h?1 with a molar ratio of H2/CO2 of 4/1. Somewhat higher total CO2 conversion was possible by increasing the H2/CO2 ratio, but the most efficient use of available H2 occurs at a lower H2/CO2 ratio.  相似文献   

10.
The capture of CO2 from a hot stove gas in steel making process containing 30 vol% CO2 by chemical absorption in a rotating packed bed (RPB) was studied. The RPB had an inner diameter of 7.6 cm, an outer diameter of 16 cm, and a height of 2 cm. The aqueous solutions containing 30 wt% of single and mixed monoethanolamine (MEA), 2-(2-aminoethylamino)ethanol (AEEA), and piperazine (PZ) were used. The CO2 capture efficiency was found to increase with increasing temperature in a range of 303–333 K. It was also found to be more dependent on gas and liquid flow rates but less dependent on rotating speed when the speed was higher than 700 rpm. The obtained results indicated that the mixed alkanolamine solutions containing PZ were more effective than the single alkanolamine solutions. This was attributed to the highest reaction rate of PZ with CO2. A higher portion of PZ in the mixture was more favorable to CO2 capture. The highest gas flow rates allowed to achieve a desired CO2 capture efficiency and the correspondent height of transfer unit (HTU) were determined at different aqueous solution flow rates. Because all the 30 wt% single and mixed alkanolamine solutions could result in a HTU less than 5.0 cm at a liquid flow rate of 100 mL/min, chemical absorption in a RPB instead of a packed bed adsorber is therefore suggested to capture CO2 from the flue gases in steel making processes.  相似文献   

11.
The biogas upgrading by membrane separation process using a highly efficient CO2-selective polyvinylamine/polyvinylalcohol (PVAm/PVA) blend membrane was investigated by experimental study and simulation with respect to process design, operation optimization and economic evaluation. This blend membrane takes advantages of the unique CO2 facilitated transport from PVAm and the robust mechanical properties from PVA, exhibits both high CO2/CH4 separation efficiency and very good stability. CO2 transports through the water swollen membrane matrix in the form of bicarbonate. CO2/CH4 selectivity up to 40 and CO2 permeance up to 0.55 m3(STP)/m2 h bar at 2 bar were documented in lab with synthesized biogas (35% CO2 and 65% CH4). Membrane performances at varying feed pressures were recorded and used as the simulation basis in this work. The process simulation of an on-farm scale biogas upgrading plant (1000 Nm3/h) was conducted. Processes with four different membrane module configurations with or without recycle were evaluated technically and economically, and the 2-stage in cascade with recycle configuration was proven optimal among the four processes. The sensitivity of the process to various operation parameters was analyzed and the operation conditions were optimized.  相似文献   

12.
At Sleipner, CO2 is being separated from natural gas and injected into an underground saline aquifer for environmental purposes. Uncertainty in the aquifer temperature leads to uncertainty in the in situ density of CO2. In this study, gravity measurements were made over the injection site in 2002 and 2005 on top of 30 concrete benchmarks on the seafloor in order to constrain the in situ CO2 density. The gravity measurements have a repeatability of 4.3 μGal for 2003 and 3.5 μGal for 2005. The resulting time-lapse uncertainty is 5.3 μGal. Unexpected benchmark motions due to local sediment scouring contribute to the uncertainty. Forward gravity models are calculated based on both 3D seismic data and reservoir simulation models. The time-lapse gravity observations best fit a high temperature forward model based on the time-lapse 3D seismics, suggesting that the average in situ CO2 density is about to 530 kg/m3. Uncertainty in determining the average density is estimated to be ±65 kg/m3 (95% confidence), however, this does not include uncertainties in the modeling. Additional seismic surveys and future gravity measurements will put better constraints on the CO2 density and continue to map out the CO2 flow.  相似文献   

13.
While the demand for reduction in CO2 emission is increasing, the cost of the CO2 capture processes remains a limiting factor for large-scale application. Reducing the cost of the capture system by improving the process and the solvent used must have a priority in order to apply this technology in the future. In this paper, a definition of the economic baseline for post-combustion CO2 capture from 600 MWe bituminous coal-fired power plant is described. The baseline capture process is based on 30% (by weight) aqueous solution of monoethanolamine (MEA). A process model has been developed previously using the Aspen Plus simulation programme where the baseline CO2-removal has been chosen to be 90%. The results from the process modelling have provided the required input data to the economic modelling. Depending on the baseline technical and economical results, an economical parameter study for a CO2 capture process based on absorption/desorption with MEA solutions was performed.Major capture cost reductions can be realized by optimizing the lean solvent loading, the amine solvent concentration, as well as the stripper operating pressure. A minimum CO2 avoided cost of € 33 tonne−1 CO2 was found for a lean solvent loading of 0.3 mol CO2/mol MEA, using a 40 wt.% MEA solution and a stripper operating pressure of 210 kPa. At these conditions 3.0 GJ/tonne CO2 of thermal energy was used for the solvent regeneration. This translates to a € 22 MWh−1 increase in the cost of electricity, compared to € 31.4 MWh−1 for the power plant without capture.  相似文献   

14.
Large volumes of CO2 captured from carbon emitters (such as coal-fired power plants) may be stored in deep saline aquifers as a means of mitigating climate change. Storing these additional fluids may cause pressure changes and displacement of native brines, affecting subsurface volumes that can be significantly larger than the CO2 plume itself. This study aimed at determining the three-dimensional region of influence during/after injection of CO2 and evaluating the possible implications for shallow groundwater resources, with particular focus on the effects of interlayer communication through low-permeability seals. To address these issues quantitatively, we conducted numerical simulations that provide a basic understanding of the large-scale flow and pressure conditions in response to industrial-scale CO2 injection into a laterally open saline aquifer. The model domain included an idealized multilayered groundwater system, with a sequence of aquifers and aquitards (sealing units) extending from the deep saline storage formation to the uppermost freshwater aquifer. Both the local CO2-brine flow around the single injection site and the single-phase water flow (with salinity changes) in the region away from the CO2 plume were simulated. Our simulation results indicate considerable pressure buildup in the storage formation more than 100 km away from the injection zone, whereas the lateral distance migration of brine is rather small. In the vertical direction, the pressure perturbation from CO2 storage may reach shallow groundwater resources only if the deep storage formation communicates with the shallow aquifers through sealing units of relatively high permeabilities (higher than 10?18 m2). Vertical brine migration through a sequence of layers into shallow groundwater bodies is extremely unlikely. Overall, large-scale pressure changes appear to be of more concern to groundwater resources than changes in water quality caused by the migration of displaced saline water.  相似文献   

15.
The CO2SINK pilot project at Ketzin is aimed at a better understanding of geological CO2 storage operation in a saline aquifer. The reservoir consists of fluvial deposits with average permeability ranging between 50 and 100 mDarcy. The main focus of CO2SINK is developing and testing of monitoring and verification technologies. All wells, one for injection and two for observation, are equipped with smart casings (sensors behind casing, facing the rocks) containing a Distributed Temperature Sensing (DTS) and electrodes for Electrical Resistivity Tomography (ERT). The in-hole Gas Membrane Sensors (GMS) observed the arrival of tracers and CO2 with high temporal resolution. Geophysical monitoring includes Moving Source Profiling (MSP), Vertical Seismic Profiling (VSP), crosshole, star and 4-D seismic experiments. Numerical models are benchmarked via the monitoring results indicating a sufficient match between observation and prediction, at least for the arrival of CO2 at the first observation well. Downhole samples of brine showed changes in the fluid composition and biocenosis. First monitoring results indicate anisotropic flow of CO2 coinciding with the “on-time” arrival of CO2 at observation well one (Ktzi 200) and the later arrival at observation well two (Ktzi 202). A risk assessment was performed prior to the start of injection. After one year of operations about 18,000 t of CO2 were injected safely.  相似文献   

16.
The kinetics of the reaction between carbon dioxide (CO2) and mixed solutions of methyldiethanolamine (MDEA) and piperazine (PZ) was investigated experimentally in a laminar jet apparatus. The experimental kinetic data were obtained under no interfacial turbulence and over a temperature range from 313 to 333 K, MDEA/PZ wt% concentration ratios of 27/3, 24/6 and 21/9, and CO2 loadings from 0.0095 to 0.33 mol CO2/mol amine. In addition, a new absorption-rate/kinetics model for the kinetics of the mixed of solvents was developed, which takes into account the coupling between chemical equilibrium, mass transfer, and all possible chemical reactions involved in the CO2 reaction with MDEA/PZ solvent. The partial differential equations of this model were solved by the finite element numerical method (FEM) based on COMSOL software. The obtained experimental kinetics data were used to obtain the kinetic parameters of CO2 absorption into MDEA/PZ solutions. The reaction-rate constant obtained for PZ blended with MDEA was kPZ = 2.572 × 1012 exp(?5211/T). The 2D model for the blended amines MDEA/PZ has revealed the concentration profiles of all the species in both the radial and axial directions of the laminar jet which has enabled a better understanding of the correct sequence in which the reaction steps involved in the reactive absorption of CO2 in aqueous mixed MDEA/PZ solution occur. It also revealed that PZ may be depleted by the time the solvent blend of MDEA/PZ with a loading greater than 0.015 mol/mol amine is exposed to CO2 from the top of the laminar jet absorber.  相似文献   

17.
A reaction calorimeter was used to determine the enthalpies of absorption of CO2 in aqueous ammonia and in aqueous solutions of ammonium carbonate at temperatures of 35–80 °C. The heat of absorption of CO2 with 2.5 wt% aqueous ammonia solution was found to be about 70 kJ/mol CO2, which is lower than that with MEA (around 85 kJ/mol) at 35 and 40 °C. The value decreases with increased loading, but not to as low a value as expected by the carbonate–bicarbonate reaction (26.88 kJ/mol). The enthalpy of absorption of CO2 in aqueous ammonia at 60 and 80 °C decreases with loadings at first, then increases between 0.2 mol CO2/mol NH3 and 0.6 mol CO2/mol NH3, and then decreases again. The behavior of the heat of absorption of CO2 in 10 wt% ammonium carbonate solution was found to be the same as that of aqueous ammonia at loadings above 0.6 mol CO2/mol NH3. The heat of absorption increases with increasing temperature. The heats of absorption are directly related to the extent of the various reactions with CO2 and can be assessed from the species variation in the liquid phase.  相似文献   

18.
We sketch four possible pathways how carbon dioxide capture and storage (CCS) (r)evolution may occur in the Netherlands, after which the implications in terms of CO2 stored and avoided, costs and infrastructural requirements are quantified. CCS may play a significant role in decarbonising the Dutch energy and industrial sector, which currently emits nearly 100 Mt CO2/year. We found that 15 Mt CO2 could be avoided annually by 2020, provided some of the larger gas fields that become available the coming decade could be used for CO2 storage. Halfway this century, the mitigation potential of CCS in the power sector, industry and transport fuel production is estimated at maximally 80–110 Mt CO2/year, of which 60–80 Mt CO2/year may be avoided at costs between 15 and 40 €/t CO2, including transport and storage. Avoiding 30–60 Mt CO2/year by means of CCS is considered realistic given the storage potential represented by Dutch gas fields, although it requires planning to assure that domestic storage capacity could be used for CO2 storage. In an aggressive climate policy, avoiding another 50 Mt CO2/year may be possible provided that nearly all capture opportunities that occur are taken. Storing such large amounts of CO2 would only be possible if the Groningen gas field or large reservoirs in the British or Norwegian part of the North Sea will become available.  相似文献   

19.
This work presents results from a rate-based model of strippers at normal pressure (160 kPa) and vacuum (30 kPa) in Aspen Custom Modeler® (ACM) for the desorption of CO2 from 5 m K+/2.5 m piperazine (PZ). The model solves the material, equilibrium, summation and enthalpy (MESH) equations, the heat and mass transfer rate equations, and computes the reboiler duty and equivalent work for the stripping process. Simulations were performed with IMTP #40 random packing and a temperature approach on the hot side of the cross-exchanger of 5 °C and 10 °C. A “short and fat” stripper requires 7–15% less total equivalent work than a “tall and skinny” one because of the reduced pressure drop. The vacuum and normal pressure strippers require 230 s and 115 s of liquid retention time to get an equivalent work 4% greater than the minimum work. Stripping at 30 kPa was controlled by mass transfer with reaction in the boundary layer and diffusion of reactants and products (88% resistance at the rich end and 71% resistance at the lean end). Stripping at 160 kPa was controlled by mass transfer with equilibrium reactions (84% resistance at the rich end and 74% resistance at the lean end) at 80% flood. The typical predicted energy requirement for stripping and compression to 10 MPa to achieve 90% CO2 removal was 37 kJ/gmol CO2. This is about 25% of the net output of a 500 MW power plant with 90% CO2 removal.  相似文献   

20.
The coal stream ignition process is critical to the performance of modern pulverized coal burners, particularly when operating under novel conditions such as experienced in oxy-fuel combustion. However, experimental studies of coal stream ignition are lacking, and recent modeling efforts have had to rely on comparisons with a single set of experiments in vitiated air. To begin to address this shortfall, we have conducted experiments on the ignition properties of two U.S. and two Chinese coals in a laminar entrained flow reactor. Most of the measurements focused on varying the coal feed rate for furnace temperatures of 1230–1320 K and for 12–20 vol.% O2 in nitrogen. The influence of coal feed rate on ignition with a carbon dioxide diluent was also measured for 20 vol.% O2 at 1280 K. A second set of measurements was performed for ignition of a fixed coal feed rate in N2 and CO2 environments at identical furnace temperatures of 1200 K, 1340 K, and 1670 K. A scientific CCD camera equipped with a 431 nm imaging filter was used to interrogate the ignition process. Under most conditions, the ignition delay decreased with increasing coal feed rate until a minimum was reached at a feed rate corresponding to a particle number density of approximately 4 × 109 m?3 in the coal feed pipe. This ignition minimum corresponds to a cold flow group number, G, of ~0.3. At higher coal feed rates the ignition delay increased. The ignition delay time was shown to be very sensitive to (a) the temperature of the hot coflow into which the coal stream is introduced, and (b) the coal particle size. The three high volatile bituminous coals showed nearly identical ignition delay as a function of coal feed rate, whereas the subbituminous coal showed slightly greater apparent ignition delay. Bath gas CO2 content was found to have a minor impact on ignition delay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号