首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 906 毫秒
1.
Emission factors for PCDD/PCDF determined from open combustion are used to estimate national emission budgets; therefore, it is important to have confidence in their accuracy. It has been suspected that artefacts may form due to the presence of hot metal surfaces of sampling equipment, thus skewing emission factors. In this study, emissions of PCDD/PCDF from open burning of forest biomass over a brick hearth were sampled. Five experiments were carried out using a portable sampler. Experiments were designed where the key variable, sample hood and inlet temperatures were manipulated. Other variables such as fuel origin, type and density were consistent. The measured concentration of PCDD/PCDF in the smoke samples ranged from 0.01 μg TEQ (t fuel)−1 at the lowest maximum hood temperature (185 °C) to 15 μg TEQ (t fuel)−1 at the highest maximum hood temperature (598 °C). when hood inlet temperatures exceeded 400 °C emission factors were significantly elevated and this is attributed to the formation of artefacts that can cause the over estimation of emission factors. The increase in hood temperature also resulted in a change in the PCDD/PCDF congener and homologue profile of the emissions. For example at the lowest temperature (Fire 1) the PCDD/PCDF ratio measured was 50:1, whereas at the highest temperature (Fire 5) this ratio was about 0.53:1. When the sampler hood and inlet temperatures were kept in the normal operating range of <200 °C, emission factors were comparable to those observed in many previous studies in Australia with emissions dominated by PCDD.  相似文献   

2.
There is a lack of information regarding persistent organic pollutants (POPs) in soil from Slovakia. This paper reports the concentrations of 17 polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), 12 dioxin-like polychlorinated biphenyls (dl-PCBs) and 6 indicator PCBs associated with 32 soil samples collected in 2007 from areas in the vicinity up to several kilometres from four selected industrial PCDD/F sources in Slovakia and one background area.The results show that the total WHO1998-PCDD/F/dl-PCB-TEQ concentrations varied from 0.34 to 18.05 pg g−1 dry weight (dw) and the average total TEQ concentrations in samples collected at the Šala, Košice, Krompachy and Dubová areas were 3.18, 2.64, 7.80, and 3.19 pg g−1 dw respectively. The average of the total WHO1998-TEQ values in three soil samples representing the background Starina area was 0.66 pg g−1 dw. The predominant contaminants among 2,3,7,8-substituted PCDD/Fs, dl-PCB, and indicator PCBs was OCDD, PCB 118, and PCB 153 respectively. The major contributors to the TEQ were 2,3,4,7,8-PeCDF, PCB 126, 1,2,3,7,8-PeCDD, PCB 156 and 1,2,3,4,7,8-HxCDF + 1,2,3,4,7,9-HxCDF in descending order.  相似文献   

3.
Two artificial wastes (A and B) whose contents reflect regional differences in municipal solid waste composition, were used to investigate the thermal formation of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), biphenyls (PCBs), and naphthalenes (PCNs) during incineration. Flue gas samples were simultaneously collected at three ports in the post-combustion zone corresponding to flue gas temperatures of 400, 300, and 200 °C. The combustion of Waste B, which had a higher chlorine and metal content than Waste A, produced greater levels of highly-chlorinated homologues, as demonstrated by a higher degree of chlorination. The total concentrations of PCDDs, PCDFs, PCBs, and PCNs formed in the combustion of both wastes increased as temperature decreased along the convector. There were no significant differences in total concentrations between Waste A and Waste B combustion at specific temperatures, with exception of PCDFs at 400 °C. Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) modeling, used to evaluate the data for all compound groups, suggest that during flue gas quenching at temperatures of 400 °C low-chlorinated homologues are preferentially formed in the presence of copper, which is known to be a very active catalyst for this process. At 300 and 200 °C, the formation of highly-chlorinated homologues is favored.  相似文献   

4.
The concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) were determined in breast milk from women living in the vicinity of a hazardous waste incinerator (HWI) in Catalonia, Spain. The results were compared with the levels obtained in previous surveys carried out in the same area in 1998 (baseline study), 2002 and 2007. The current total concentrations of 2,3,7,8-chlorinated PCDD/Fs in breast milk ranged from 18 to 126 pg g−1 fat (1.1–12.3 pg WHO2005-TEQPCDD/F), while the total levels of PCBs ranged from 27 to 405 pg g−1 fat (0.7–5.3 pg WHO2005-TEQPCB). In turn, PBDE concentrations (sum of 15 congeners) ranged 0.3–5.1 g g−1 fat, with a mean value of 1.3 ng g−1 fat. A general decrease in the concentrations for PCDD/Fs, both planar and total PCBs, and PBDEs in breast milk was observed. The levels of PCDD/Fs, PCBs, and PBDEs in milk of women living in urban zones were higher than those corresponding to industrial zones (41%, 26%, and 8%, respectively). For PCDD/Fs and PCBs, the current decreases are in accordance with the reduction in the dietary intake of these pollutants that we have also observed in recent studies carried out in the same area of study.  相似文献   

5.
The aim of this work is to evaluate the performance of a continuous monitoring system for the analysis of the mass concentration of PCDD/Fs from stationary sources. Data was acquired from a modern, state of the art, hazardous waste thermal treatment plant for a period of more than 2 years using a commercial available continuous monitoring system. The study consisted of a total of 16 samples, collected in periods from 1 week to 2 months resulting in an average of 360 m3 sampled flue gas per sample. The study showed the system was able to confirm that for a period of more than 2 years the plant was complying with the limit of 0.1 ng I-TEQ/Nm3. In addition, the data showed the typical fingerprint of such installations which is useful for example in impact studies. Long-term samples were compared to five short-term samples (6 h) collected every 6 months during the study period. Principal component analysis was applied to PCDD/Fs obtained data as useful statistical tool to find out trends and similarities between different samples. Improvement in terms of representativeness of data was achieved through continuous assessment since the starts of the project. The obtained data was further used to determine the emission factor for this activity and the total annual PCDD/Fs release to the atmosphere.  相似文献   

6.
Wu HL  Lu SY  Yan JH  Li XD  Chen T 《Chemosphere》2011,84(3):361-367
The fly ash used in this study was collected from a bag filter in a medical waste rotary kiln incineration system, using lime and activated carbon injection followed by their collection as mixed fly ash. Experiments were conducted on fly ash in a quartz tube, heated in a laboratory-scale horizontal tube furnace, in order to study the effect of temperature and nitrogen flow rate on the removal of PCDD/Fs. Results indicated that in this study PCDD/Fs in the fly ash mostly were removed and desorbed very little into the flue gas under thermal treatment especially when the heating temperature was higher than 350 °C, and dechlorination and destruction reactions took important part in the removal of PCDD/Fs. However, in terms of flow rate, when flow rate was higher than 4 cm s−1, destruction efficiency of PCDD/Fs decreased dramatically and the main contributors were P5CDF, H6CDF and H7CDF desorbed to flue gas, the PCDD/Fs in the fly ash decreased with enhanced flow rate.  相似文献   

7.
Shin SK  Jin GZ  Kim WI  Kim BH  Hwang SM  Hong JP  Park JS 《Chemosphere》2011,83(10):1339-1344
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) were measured in ambient air samples collected from different parts of South Korea in 2008, and the measured levels were used for assessing the spatial and temporal distribution of atmospheric PCDDFs and DL-PCBs in South Korea. The average concentrations of atmospheric PCDD/Fs and DL-PCBs among the 37 sites were 28 fg I-TEQ m−3 (ND ∼ 617) and 1 fg WHO-TEQ m−3 (ND ∼ 0.016). Elevated atmospheric levels of PCDD/Fs and DL-PCBs observed at residential/industrial sites and in the north-west of Korea, indicated a potential contribution and impacts of anthropogenic sources of PCDD/Fs and DL-PCBs. These levels were similar or lower than those previously reported in other ambient air surveys. Average concentrations of PCDD/Fs showed small seasonal variations (ANOVA analysis, p = 0.144). The highest concentrations of PCDD/Fs were observed during winter, followed by spring, autumn and summer. Atmospheric PCDD/Fs and DL-PCBs in South Korea rapidly decreased during the last 10 years (1998-2008), demonstrating the efficiency of stricter regulations and the application of best available technologies/best environmental practices at emission sources. Comparison of the congener profiles and principal component analysis showed that current atmospheric PCDD/Fs are mostly influenced by industrial sources and PCBs from old commercial PCB uses. Nationwide POPs monitoring will continue and allows an effective evaluation of the implementation of the Stockholm Convention on POPs.  相似文献   

8.
Both long duration (>6 h) and high temperature (up to 139 °C) sampling efforts were conducted using ambient air sampling methods to determine if either high volume throughput or higher than ambient air sampling temperatures resulted in loss of target polychlorinated dibenzodioxins/dibenzofurans (PCDDs/PCDFs) from a polyurethane foam (PUF) sorbent. Emissions from open burning of simulated military forward operating base waste were sampled using EPA Method TO-9A for 185 min duration using a filter/PUF/PUF in series combination. After a 54 m3 sample was collected, the sampler was removed from the combustion source and the second PUF was replaced with a fresh, clean PUF. An additional 6 h of ambient air sampling (171 m3) was conducted and the second PUF was analyzed to determine if the PCDD/PCDF transferred from the filter and the first PUF. Less than 4.4% of the initial PCDD/PCDF was lost to the second PUF. To assess the potential for blow off of PCDD/PCDF analytes during open air sampling, the mobility of spiked mono- to hepta-PCDD/PCDF standards across a PUF sorbent was evaluated from ambient air temperatures to 145 °C with total volumes between 600 L and 2400 L. Lower molecular weight compounds and higher flow amounts increased release of the spiked standards consistent with vapor pressure values. At 600 L total sampled volume, the release temperature for 1% of the tetra-CDD (the lowest chlorinated homologue with a toxic compound) was 87 °C; increasing the volume fourfold reduced this temperature to 73 °C.  相似文献   

9.
Lundin L  Aurell J  Marklund S 《Chemosphere》2011,84(3):305-310
The polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) content of three fly ash samples with different elemental compositions from different municipal waste incinerators were analyzed before and after thermal treatment at 300 °C or 500 °C. Gas phase emissions during the treatments were also collected and analyzed. Substantial reductions in the total PCCD/F content of the ashes were observed after treatment at 500 °C, seemingly due to degradation rather than dechlorination. Treatment at 300 °C resulted in an increase in the PCDD/F content of the three ashes. Initial concentration of PCDD/F in the untreated ashes did not reflect the outcome of the treatment at the different temperatures. In addition, the composition of the ash was found to influence the rate of decomposition and formation of PCDD and PCDF during thermal treatment; the results showed that Cu, Fe, Ca and S play important roles in these processes.  相似文献   

10.
Homologue and congener profiles of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in commercial PCBs formulations are key information for the source identification of PCBs contamination as well as for the risk assessment caused by potential exposure. The isotope dilution technology in combination with high resolution gas chromatography-high resolution mass spectrometry (HRGC/HRMS) has made the accurate determination of such profiles possible. So far, various commercial PCB formulations except Chinese products have been successfully determined. Two PCBs containing insulating oil samples from stored Chinese electrical capacitors have been determined with the same methodology for comparability. The total concentration PCBs in two oil samples were 790 000 μg g−1 and 720 000 μg g−1, respectively. TriCBs, TetraCBs, and DiCBs were found to be most abundant. Concentration of dioxins contamination in two samples is 650-670 ngTEQ g−1, of which 69-71 ngTEQ g−1 from PCDD/Fs with the predominant congeners of 1,2,7,8-TeCDF; 2,3,7,8-TeCDF; 2,3,4,7,8-PeCDF and 1,2,3,7,8-PeCDF. The contributions of DL-PCBs in total TEQ in both samples were more than 85%. The dioxin-like toxicity in insulating oils contained in electrical capacitors could be considered receive attention as an important dioxins source if such wastes are not managed in an environmentally sound manner.  相似文献   

11.
Lv P  Zheng M  Liu G  Liu W  Xiao K 《Chemosphere》2011,82(5):759-763
The iron foundry industry is considered to be a potential source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study investigated the emission factors and total emission amounts of PCDD/Fs and dioxin-like polychlorinated biphenyls (DL-PCBs) from iron foundries in China. The concentrations and the World Health Organization toxicity equivalents (WHO-TEQs) are presented and the congener profiles are discussed in this paper.In the present work, 26 fly ash samples were collected and tested to quantify the PCDD/Fs and DL-PCBs generated by 14 plants of different scales, and five stack gas samples were collected from two (named as EFG and LFG) of those plants. The emission levels of PCDD/Fs and DL-PCBs indicated that hot-air cupolas had lower emissions than cold-air cupolas. When iron ore lump and sinter were used as raw material, the emission factors were about 250 ng TEQ t−1 of product. However, if the raw material was scrap, the emission factors varied owing to the different contents of organic materials in the raw materials. It was found that the mean WHO-TEQ values of PCDD/Fs and DL-PCBs were 144 and 34.2 pg Nm−3 in stack gas and 20.0 and 1.58 pg g−1 in fly ash. In multiple tests, it was estimated that the mean emission factors of PCDD/Fs and DL-PCBs were 365 and 10.9 ng WHO-TEQ t−1 released to residue and 2719 and 555 ng TEQ t−1 released to air. The total emission amounts of PCDD/Fs and DL-PCBs from Chinese iron foundries with cupola furnaces released to residue and air were 16.8 and 146 g WHO-TEQ in 2008, respectively.  相似文献   

12.
Particle-bound polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in ambient air were monitored together with particulate matter less than 10 μm (PM10) at three sampling sites of the Andean city of Manizales, Colombia; during September 2009 and July 2010. PCDD/Fs ambient air emissions ranged from 1 fg WHO-TEQ m−3 to 52 fg WHO-TEQ m−3 in particulate fraction. The PM10 concentrations ranged from 23 μg m−3 to 54 μg m−3. Concentrations of PM10 and PCDD/Fs in ambient air observed for Manizales - a medium sized city with a population of 380 000 - were comparable to concentrations in larger cities. The highest concentrations of PCDD/Fs and PM10 found in this study were determined at the central zone of the city, characterized by public transportation density, where diesel as principal fuel is used. In addition, hypothetical gas fractions of PCDD/Fs were calculated from theoretical Kp data. Congener profiles of PCDD/Fs exhibited ratios associated with different combustion sources at the different sampling locations, ranging from steel recycling to gasoline and diesel engines. Taking into account particle and gas hypothetical fraction of PCDD/Fs, Manizales exhibited values of PCDD/Fs equivalent to rural and urban-industrial sites in the southeast and center of the city respectively. Poor correlation of PCDDs with PM10 (r = −0.55 and r = 0.52) suggests ambient air PCDDs were derived from various combustion sources. Stronger correlation was observed of PCDFs with PM10. Poor correlation between precipitation and reduced PM10 concentration in ambient air (r = −0.45) suggested low PM10 removal by rainfall.  相似文献   

13.
Thuan NT  Tsai CL  Weng YM  Lee TY  Chang MB 《Chemosphere》2011,83(6):760-766
Twenty-one fresh water samples were taken from reservoirs, wells and drinking water treatment plants in Taiwan for measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) concentrations. Due to low concentration of PCDD/Fs, water samples (400-1000 L) were collected by using the on-site large volume pre-concentration system and analyzed by high resolution gas chromatography (HRGC)/high resolution mass spectrometer (HRMS). Different characteristics of dioxin profiles in surface water and groundwater are observed. The PCDD/F concentrations in fresh water samples varied from 0.001 to 0.265 pg WHO98-TEQ/L which are lower than the standard (12 pg WHO98-TEQ/L) set by the Taiwan Environmental Protection Administration (TEPA) for drinking water. Only a small fraction (<5%) of the total PCDD/F concentration in fresh water samples was water-soluble. As a result of their hydrophobicity, PCDD/Fs are effectively removed along with suspended solid via the water treatment process (average 98% removal efficiency).  相似文献   

14.
Column experiments were conducted to validate a screening model predicting the influence of pentachlorophenol (PCP) pole-treating oil on the vertical migration of its impurities, chlorinated dioxins and furans (PCDD/Fs). PCP pole-treating oil (15 mL d−1) and water (20 mL d−1) were added daily to the top of sand and organic soil columns during 35 d. Column soil samples were analyzed to determine concentrations of hydrocarbons and PCDD/Fs at several depths in the columns (0-30 cm) and their evolution in time (7, 14, 21 and 35 d).The model predicted a significant vertical migration of PCDD/Fs due to the presence of oil as a free phase and PCDD/Fs were found in the different column layers at concentrations consistent with model predictions (same order of magnitude). Measured PCDD/Fs concentrations are in total disagreement with literature data and with model prediction in the absence of oil free phase, which implies PCDD/F properties alone cannot be used to predict their fate in the current context: the influence of PCP pole-treating oil must be accounted for to properly explain their migration.  相似文献   

15.
Chicken eggs from five different production types (conventional, omega-3 enriched, free range, organic and free run) were collected, when available, from three regions (west, central and east) of Canada to determine persistent organic pollutant (POP) concentrations. Total polychlorinated biphenyl (PCB) concentrations (∑37 congeners) in yolks from the eggs ranged from 0.162 ng g−1 lipid to 24.8 ng g−1 lipid (median 1.25 ng g−1 lipid) while the concentration of the sum of the 6 indicator PCBs ranged from 0.100 ng g−1 lipid to 9.33 ng g−1 lipid (median 0.495 ng g−1 lipid). Total polychlorinated dibenzo-p-dioxin/dibenzofuran (PCDD/F) concentrations ranged from 2.37 pg g−1 lipid to 382 pg g−1 lipid (median 9.53 pg g−1 lipid). The 2005 WHO toxic equivalency (TEQ) ranged from 0.089 pg TEQPCDD/F+dioxin-like[DL]-PCB g−1 lipid to 12.8 pg TEQPCDD/F+DL-PCB g−1 lipid (median 0.342 pg TEQPCDD/F+DL-PCB g−1 lipid). PCB and PCDD/F concentrations were significantly different (p < 0.001) in egg yolks from different regions of collection. In contrast to observations in Europe, PCB and PCDD/F concentrations in Canadian egg yolks were not impacted solely by the production type (e.g., conventional, free range, organic, etc.) used to maintain the laying chickens. Additionally, only one Canadian free range yolk from western Canada (12.8 pg TEQPCDD/F+DL-PCB g−1 lipid) exceeded the European toxic equivalent concentration limits for eggs (5 pg TEQPCDD/F+DL-PCB g−1 lipid). This differs from observations in Europe where free range/home produced eggs frequently have higher POP concentrations than eggs from other production types. Median PCB dietary intake estimates based on consumption of eggs were less than 10 ng d−1 while median PCDD/F intakes were less than 45 pg d−1.  相似文献   

16.
The yield of PCDD/F in relation to the presence of oxygenated PAH in model waste incinerator flyash has been investigated in a fixed bed laboratory scale reactor. Experiments were undertaken by thermal treatment of the model flyash at 250 and 350 °C under a simulated flue gas stream for 2 h. After reaction, the PCDD/F content of the reacted flyash and the PCDD/F released into the exhaust gas, and subsequently trapped by XAD-II resin in a down-stream condensation system were analyzed. The PAHs investigated were, dibenzofuran and benzo[b]naphtho[2,3-d]furan and were spiked onto the model flyash as reactant precursors for PCDD/F formation. The results showed significant formation of furans from both of the PAH investigated, however except from some highly chlorinated dioxin congeners, the formation of dioxins was not so common. Benzonaphthofuran was significantly more reactive than dibenzofuran in PCDD/F formation, in spite of the fact that dibenzofuran is structurally more similar to that of PCDD/F. Thus, there was no clear attribution between the chemical structure of PAH used and the formation of PCDD/F. There were considerable differences between the yields of PCDD/F congeners in the gaseous species and those in the reacted flyash under the same operational conditions. The concentration of PCDD/Fs was reduced at the higher reaction temperature of 350 °C; however, the higher temperature resulted in the majority of the PCDD/F formed on the flyash being released into the gas phase.  相似文献   

17.
Liu W  Tao F  Zhang W  Li S  Zheng M 《Chemosphere》2012,86(3):248-251
The production of chloranil is regarded as a potentially significant source of unintentional POPs. This research aimed to identify the contamination levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), hexachlorobenzene (HxCBz), pentachlorobenzene (PeCBz) and polychlorophenols in chloranil samples and identify the formation pathways. The toxicity equivalent (TEQ) values for PCDD/Fs in the chloranil samples ranged from 163 to 1 540 200 pg I-TEQ g−1, while the PCB TEQ values ranged from 1.9 to 3.3 pg WHO-TEQ g−1. High levels of HxCBz, PeCBz and polychlorophenols were also detected in the chloranil samples. The average emission factors were 522.2 mg I-TEQ t−1 (PCDD/Fs), 0.0026 mg WHO-TEQ t−1 (PCBs), 32.6 mg t−1 (HxCBz), and 136.6 mg t−1 (PeCBz). The PCDD/Fs and PCBs are thought to be formed from the polychlorophenols and polychlorobenzenes generated during the chloranil production process. Purification of the chloranil products can reduce the unintentional POPs releases and protect the environment.  相似文献   

18.
There is a strong need for the development of relatively rapid and low-cost bioassays for the determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), and dioxin-like polychlorinated biphenyls (dl-PCBs) in environmental and food samples. In this study, we applied a reporter gene assay using DR-EcoScreen cells (DR-cell assay), which is highly sensitive to dioxins, to the determination of PCDD/Fs and dl-PCBs in fish and seafood samples. The PCDD/Fs and dl-PCBs were extracted from homogenated samples (10 g) of 30 fish and shellfish, purified by clean-up procedure using a multilayered silica gel column and an alumina column, and applied to DR-cell assay. Interestingly, the bioanalytical equivalent (BEQ) values obtained from the DR-cell assay [<0.1 ∼ 5.4 pg BEQ g−1 wet weight (ww)] were closely correlated with the toxicity equivalent (TEQ) values from conventional high-resolution gas chromatography/high-resolution mass spectrometry (HRGC-HRMS) analysis (r2 = 0.912), and the slope of regression line was 0.913. Therefore, we multiplied the BEQ values from the DR-cell assay by a conversion coefficient (1.095, the reciprocal of 0.913) to approximate the TEQ values from the HRGC-HRMS analysis. Furthermore, we used this DR-cell assay to perform a prescreening test of PCDD/Fs and dl-PCBs in 16 fish and seafood samples purchased from a supermarket, revealing that a sample from the fatty flesh of a bluefin tuna exceeded 8 pg TEQ g−1 ww (the European Union-tolerance limit). Taken together, these results suggest that the DR-cell assay might be applicable as a rapid and low-cost prescreening method to determine dioxin levels in fish and seafood samples.  相似文献   

19.
Nie Z  Zheng M  Liu W  Zhang B  Liu G  Su G  Lv P  Xiao K 《Chemosphere》2011,85(11):1707-1712
Magnesium production is considered to be one potential source of unintentional persistent organic pollutants (unintentional POPs). However, studies on the emissions of unintentional POPs from magnesium metallurgy are still lacking. Emissions of unintentional POPs, such as polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), dioxin-like polychlorinated biphenyls (dl-PCBs), polychlorinated naphthalenes (PCNs), hexachlorobenzene (HxCBz) and pentachlorobenzene (PeCBz) are covered under the Stockholm Convention. In this study, these emissions were investigated through a magnesium smelting process. Stack gas and fly ash samples from a typical magnesium plant in China were collected and analyzed to estimate the emissions of unintentional POPs from magnesium metallurgy. Emissions factors of 412 ng TEQ t−1 for PCDD/Fs, 18.6 ng TEQ t−1 for dl-PCBs, 3329 μg t−1 for PCNs, 820 μg t−1 for HxCBz, and 1326 μg t−1 for PeCBz were obtained in 2009. Annual emissions from magnesium metallurgy in China were estimated to be 0.46 g WHO-TEQ for PCDD/Fs and dl-PCBs, 1651 g for PCNs, 403 g for HxCBz and 653 g for PeCBz, respectively.  相似文献   

20.
PAHs, PCDD/Fs and non-ortho PCBs have been assessed in Yser and Upper-Scheldt river sediments. Higher contamination levels were observed in the Upper-Scheldt sediments: maximum concentrations for the 16 US-EPA PAHs, PCDD/Fs and non-ortho PCBs respectively amount to 8.9 mg kg−1, 12 ng TEQ kg−1 and 5.1 ng TEQ kg−1. Diagnostic PAH ratios in sediments and atmospheric samples suggest that the PAH compounds are from pyrolytic origin, more specifically combustion processes. The huge consumption of coal in cokes-ovens and smelters and its use for house-heating in Northern France, although decreasing during the last decades, are in support of that suggestion. PCDD/F fingerprints in sediments and deposition material indicate that OCDD is the dominant congener. In addition use of pentachlorophenol (PCP) in the past led to a minor contribution of PCDD/Fs in our sediment samples. Non-ortho PCBs form a substantial fraction of the total TEQ concentrations observed in the sediments. Since the 1980s and 1990s a substantial reduction of the PCDD/F sediment concentrations is observed, but this is not the case for the PAHs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏