首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
Abstract

Ozone and several polar volatile organic compounds (VOCs) including organic acids and carbonyls (aldehydes and ketones) were measured over an approximately 24 hour period in four residences during the winter of 1993 and in nine residences during the summer of 1993. All residences were in the greater Boston, Massachusetts area. The relation of the polar VOCs to the ozone concentration was examined. Indoor carbonyl concentrations were similar between the summer and winter, with the total mean winter concentration being 31.7 ppb and the total mean summer concentration being 36.6 ppb. However, the average air exchange rate was 0.9 hr?1 during the winter and 2.6 hr?1 during the summer. Therefore, the estimated carbonyl emission rates were significantly higher during the summer. Indoor organic acid concentrations were about twice as high during the summer as during the winter. For formic acid, the indoor winter mean was 9.8 ppb, and the summer indoor mean was 17.8 ppb. For acetic acid, the indoor winter mean was 15.5 ppb, and the summer indoor mean was 28.7 ppb. The concentrations of the polar VOCs were found to be significantly correlated with one another. Also, the emission rates of the polar VOCs were found to be correlated with both the environmental variables such as temperature and relative humidity and the ozone removal rate; however, it was difficult to apportion the relative effects of the environmental variables and the ozone removal.  相似文献   

2.
For 41 days between 25 May 1996 and 27 March 1997, peroxyacetyl nitrate (PAN) and peroxypropionyl nitrate (PPN) have been measured by electron capture gas chromatography at Santa Rita near Porto Alegre, RS, Brazil, where light-duty vehicles used either ethanol or a gasoline–MTBE blend. Daily maximum concentrations ranged from 0.19 to 6.67 ppb for PAN and 0.06 to 0.72 ppb for PPN. Linear regression of maximum PPN vs. maximum PAN yielded a slope of 0.105±0.004 (R2=0.974). Diurnal variations of ambient PAN often followed those of ozone with respect to time of day but not with respect to amplitude. This was reflected in the large relative standard deviations associated with the study-averaged PAN/ozone concentration ratio, 0.037±0.105 (ppb/ppb, n=789) and the maximum PAN/maximum ozone concentration ratio, 0.028±0.015 (ppb/ppb, range 0.005–0.078, n=41). On several days PAN accounted for large fractions of the total ambient NOx in the late morning and afternoon hours, e.g., PAN/NOx⩽0.58 and PAN/(NOx–NO) ⩽0.76 on 27 March 1997. The amount of PAN lost by thermal decomposition (TPAN) was comparable in magnitude to that present in ambient air. The ratios TPAN/(PAN+TPAN) were up to 0.53, 0.67 and 0.64 during the warm afternoons of 25, 26 and 27 March 1997, respectively. The highest calculated value of TPAN was 5.6 ppb on 27 March 1997. On that day the 24 h-averaged value of TPAN (1.01 ppb) was nearly the same as that of PAN (1.09 ppb). Using computer kinetic modeling (SAPRC 97 chemical mechanism) and sensitivity analysis of VOC incremental reactivity, we ranked VOC present in Porto Alegre ambient air for their importance as precursors to PAN and to PPN. Using as input data the averages of VOC concentrations measured in downtown Porto Alegre during the ca. 1 yr period March 1996–April 1997, we calculated that the most important precursors to PAN and PPN were the SAPRC 97 model species ARO2 (which includes the aromatics xylenes, trimethylbenzenes, ethyltoluenes, etc.), which accounted for ca. 17% of the total PAN and total PPN formation potentials. Overall, the results indicate a major role for aromatics and alkenes and a minor role for acetaldehyde and ethanol as precursors to peroxyacyl nitrates in the Porto Alegre urban area.  相似文献   

3.
Polycyclic aromatic hydrocarbon (PAH) concentrations were measured in Pontoporeia hoyi, the most abundant benthic organism in Lake Michigan, and in its associated sediment/pore water matrix. Individual PAH concentrations ranged from 10 ppb to 1 ppm in three sedimentary environments having different levels of organic carbon. Pore water concentrations appeared to be independent of sediment concentrations. P. hoyi bioconcentration factors ranged from approximately 104 to 105 for seven analyzed PAHs. A major fraction of the phenanthrene, fluoranthene and pyrene in P. hoyi appears to come from sediments and pore water, while chrysene and BaP are primarily obtained from water.  相似文献   

4.

Purpose

The purpose of this study is the development of a suitable process for the disinfection of drinking water by evaluating bactericidal efficacy of silver ions from silver electrodes.

Methods

A prototype of a silver ioniser with silver electrodes and control unit has been fabricated. Silver ions from silver electrodes in water samples were estimated with an atomic absorption spectrophotometer. A fresh culture of Escherichia coli (1.75?×?103 c.f.u./ml) was exposed to 1, 2, 5, 10 and 20?ppb of silver ions in 100?ml of autoclaved tap water for 60?min. The effect of different pH and temperatures on bactericidal efficacy was observed at constant silver ion concentration (5?ppb) and contact time of 30?min.

Results

The maximum bactericidal activity (100%) was observed at 20?ppb of silver ion concentration indicating total disinfection after 20?min while minimum bactericidal activity (25%) was observed after 10?min at 01?ppb of silver ions. Likewise, 100% bactericidal activity was noticed with 2, 5 and 10?ppb of silver ions after 60, 50 and 40?min, respectively. Bactericidal activity at pH?5, 6, 7, 8 and 9 was observed at 79.9%, 79.8%, 80.5%, 100% and 100%, respectively, whereas it was 80.4%, 88.3%, 100%, 100% and 100% at 10°C, 20°C, 30°C, 40°C and 50°C, respectively.

Conclusion

The findings of this study revealed that very low concentrations of silver ions at pH?8?C9 and temperature >20°C have bactericidal efficacy for total disinfection of drinking water. Silver ionisation is suitable for water disinfection and an appropriate alternative to chlorination which forms carcinogenic disinfection by-products.  相似文献   

5.
Aircraft measurements of air pollutants were made to investigate the characteristic features of long-range transport of sulfur compounds over the Yellow Sea for the periods of 26–27 April and 7–10 November in 1998, and 9–11 April and 19 June in 1999, together with aerosol measurements at the Taean background station in Korea. The overall mean concentrations of SO2, O3 and aerosol number in the boundary layer for the observation period ranged 0.1–7.4 ppb 32.1–64.1 ppb and 1.0–143.6 cm−3, respectively. It was found that the air mass over the Yellow Sea had a character of both the polluted continental air and clean background air, and the sulfur transport was mainly confined in the atmospheric boundary layer. The median of SO2 concentration within the boundary layer was about 0.1–2.2 ppb. However, on 8 November, 1998, the mean concentrations of SO2 and aerosol number increased up to 7.4 ppb and 109.5 cm−3, respectively, in the boundary layer, whereas O3 concentration decreased remarkably. This enhanced SO2 concentration occurred in low level westerly air stream from China to Korea. Aerosol analyses at the downstream site of Taean in Korea showed 2–3 times higher sulfate concentration than that of other sampling days, indicating a significant amount of SO2 conversion to non sea-salt sulfate during the long-range transport.  相似文献   

6.
Ozone was measured in six- and NOx in five sampling periods in 1996–97, mostly during summer, at a 1070 m altitude site in northern Peloponnese. Mean values in each sampling period ranged from 43–48 ppb exceeding the European Union 24 h plant protection standard. The background ozone concentration of 43 ppb derived from the correlation of ozone with NOx also exceeded the EU plant protection standard. Ozone exhibited maxima in the afternoon and minima during the night; in certain 24–48 h periods, however, the ozone concentrations remained practically constant; in these short periods air mass back trajectories indicated air masses which originated in north Africa. NOx concentrations had maximum of 24 h around noon. Their mean concentrations ranged from 0.5–0.7 ppb, smaller than respective concentrations in north-central Europe.  相似文献   

7.
Abstract

Controlled bench-scale laboratory experiments were conducted to evaluate the recovery of ammonia (NH3) and hydrogen sulflde (H2S) from dynamic isolation flux chambers. H2S (80–4000 ppb) and NH3 (5000–40,000 ppb) samples were diffused through the flux chamber to simulate ground level area source emissions while measuring the inlet and outlet flux chamber concentrations simultaneously. Results showed that the recovery of H2S during a 30-min sampling time was almost complete for concentrations >2000 ppb. At the lowest concentration of 80 ppb, 92.55% of the H2S could be recovered during the given sampling period. NH3 emissions exhibited similar behavior between concentrations of 5000–40,000 ppb. Within the 30-min sampling period, 92.62% of the 5000-ppb NH3 sample could be recovered. Complete recovery was achieved for concentrations >40,000 ppb. Predictive equations were developed for gas adsorption. From these equations, the maximum difference between chamber inlet and outlet concentrations of NH3 or H2S was predicted to be 7.5% at the lowest concentration used for either gas. In the calculation of emission factors for NH3 and H2S, no adsorption correction factor is recommended for concentrations >37,500 ppb and 2100 ppb for NH3 and H2S, respectively. The reported differences in outlet and inlet concentration above these ranges are outside the full-scale sensitivity of the gas sensing equipment. The use of 46–90 m of Teflon tubing with the flux chambers has apparently no effect on gas adsorption, because recovery was completed almost instantaneously at the beginning of the tests.  相似文献   

8.
Air quality impacts of volatile organic compound (VOC) and nitrogen oxide (NOx) emissions from major sources over the northwestern United States are simulated. The comprehensive nested modeling system comprises three models: Community Multiscale Air Quality (CMAQ), Weather Research and Forecasting (WRF), and Sparse Matrix Operator Kernel Emissions (SMOKE). In addition, the decoupled direct method in three dimensions (DDM-3D) is used to determine the sensitivities of pollutant concentrations to changes in precursor emissions during a severe smog episode in July of 2006. The average simulated 8-hr daily maximum O3 concentration is 48.9 ppb, with 1-hr O3 maxima up to 106 ppb (40 km southeast of Seattle). The average simulated PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) concentration at the measurement sites is 9.06 μg m?3, which is in good agreement with the observed concentration (8.06 μg m?3). In urban areas (i.e., Seattle, Vancouver, etc.), the model predicts that, on average, a reduction of NOx emissions is simulated to lead to an increase in average 8-hr daily maximum O3 concentrations, and will be most prominent in Seattle (where the greatest sensitivity is??0.2 ppb per % change of mobile sources). On the other hand, decreasing NOx emissions is simulated to decrease the 8-hr maximum O3 concentrations in remote and forested areas. Decreased NOx emissions are simulated to slightly increase PM2.5 in major urban areas. In urban areas, a decrease in VOC emissions will result in a decrease of 8-hr maximum O3 concentrations. The impact of decreased VOC emissions from biogenic, mobile, nonroad, and area sources on average 8-hr daily maximum O3 concentrations is up to 0.05 ppb decrease per % of emission change, each. Decreased emissions of VOCs decrease average PM2.5 concentrations in the entire modeling domain. In major cities, PM2.5 concentrations are more sensitive to emissions of VOCs from biogenic sources than other sources of VOCs. These results can be used to interpret the effectiveness of VOC or NOx controls over pollutant concentrations, especially for localities that may exceed National Ambient Air Quality Standards (NAAQS).

Implications: The effect of NOx and VOC controls on ozone and PM2.5 concentrations in the northwestern United States is examined using the decoupled direct method in three dimensions (DDM-3D) in a state-of-the-art three-dimensional chemical transport model (CMAQ). NOx controls are predicted to increase PM2.5 and ozone in major urban areas and decrease ozone in more remote and forested areas. VOC reductions are helpful in reducing ozone and PM2.5 concentrations in urban areas. Biogenic VOC sources have the largest impact on O3 and PM2.5 concentrations.  相似文献   

9.
Metropolitan Taipei, which is located in the subtropical area, is characterized by high population and automobile densities. For convenience, most primary schools are located near major roads. This study explores the exposure of acid aerosols for schoolchildren in areas in Taipei with different traffic densities. Acid aerosols were collected by using a honeycomb denuder filter pack sampling system (HDS). Experimental results indicated that the air pollutants were significantly correlated with traffic densities. The ambient air NO2, SO2, HNO3, NO3, SO42−, and aerosol acidity concentrations were 31.3 ppb, 4.7 ppb, 1.3 ppb, 1.9 μg m−3, 18.5 μg m−3, and 49.5 nmol m−3 in high traffic density areas, and 6.1 ppb, 1.8 ppb, 0.9 ppb, 0.7 μg m−3, 8.8 μg m−3 and 14.7 nmol m−3 in low traffic density areas. The exposure levels of acid aerosols for schoolchildren would be higher than the measurements because the sampling height was 5 m above the ground. The SO2 levels were low (0.13–8.03 ppb) in the metropolitan Taipei. However, the SO42− concentrations were relatively high, and might be attributed to natural emissions of sulfur-rich geothermal sources. The seasonal variations of acid aerosol concentrations were also observed. The high levels of acidic particles in spring time may be attributed to the Asian dust storm and low height of the mixture layer. We conclude that automobile contributed not only the primary pollutants but also the secondary acid aerosols through the photochemical reaction. Schoolchildren were exposed to twice the acid aerosol concentrations in high traffic density areas compared to those in low traffic density areas. The incidence of allergic rhinitis of schoolchildren in the high traffic density areas was the highest in spring time. Accompanied by high temperature variation and high levels of air pollution in spring, the health risk of schoolchildren had been observed.  相似文献   

10.
11.
Abstract

A comprehensive, systematic synthesis was conducted of daily time-series studies of air pollution and mortality from around the world. Estimates of effect sizes were extracted from 109 studies, from single- and multipollutant models, and by cause of death, age, and season. Random effects pooled estimates of excess all-cause mortality (single-pollutant models) associated with a change in pollutant concentration equal to the mean value among a representative group of cities were 2.0% (95% CI 1.5-2.4%) per 31.3 μg/m3 particulate matter (PM) of median diameter <10 μm (PM10); 1.7% (1.2-2.2%) per 1.1 ppm CO; 2.8% (2.1-3.5%) per 24.0 ppb NO2; 1.6% (1.1-2.0%) per 31.2 ppb O3; and 0.9% (0.7-1.2%) per 9.4 ppb SO2 (daily maximum concentration for O3, daily average for others). Effect sizes were generally reduced in multipollutant models, but remained significantly different from zero for PM10 and SO2. Larger effect sizes were observed for respiratory mortality for all pollutants except O3. Heterogeneity among studies was partially accounted for by differences in variability of pollutant concentrations, and results were robust to alternative approaches to selecting estimates from the pool of available candidates. This synthesis leaves little doubt that acute air pollution exposure is a significant contributor to mortality.  相似文献   

12.
Abstract

Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography.

Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina.

Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 ± 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 ± 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 ± 6.3 ppb, n = 22).  相似文献   

13.
In the summer of 1998, the air quality (indicators: CO, NO, NO2, O3) above the water surface of the Lake Balderey (Essen, Ruhr area, North Rhine-Westphalia, Germany), an artificial lake used for recreation purposes, was measured using the Fourier transform infrared spectroscopy (FTIR) and differential optical absorption spectroscopy (DOAS) remote measurement methods. The lake, with an area of 3 km2 was created by damming the Ruhr and is surrounded by higher ground. In calm, bright weather conditions, this location results in a low-exchange situation (formation of temperature inversions, cold air dynamics) with a sustained impact on pollutant concentrations over the lake. The results of trace substance measurements (1/2 h mean values) were compared with values from comparison stations (suburban, high traffic and forest) located outside the area of the lake. In general, it was found that mean CO and NO concentrations over the lake were very low (0.3 ppm and 7.5 ppb, respectively). NO2 values (15 ppb) were some 3.5 times higher than those recorded at the forest station and O3 values, at 27 ppb, almost reached the same level as at the forest station (30 ppb). Mass flow densities as a function of wind direction, diurnal courses, differences between weekdays and weekends and comparisons with air quality standards are presented for the lake station.  相似文献   

14.
Abstract

An improved ion chromatographic (IC) method has been developed for the separation of nitrate in filter extracts in the presence of high concentrations of nitrite. This analytical method was successfully used for an indirect measurement of ozone (O3) in outdoor and indoor air, following its collection using a nitrite-impregnated passive sampler. The limit of detection and the limit of quantification, using the modified IC method, were 6 μg l-1 (3σ) and 20 μg l-1 (10σ), respectively. Improved detection limits and low baseline noise were obtained with the use of eluent generator and high-capacity ion exchange column. The optimized method was used for assessing O3 concentration in both indoor and outdoor environments of 28 child care centers (CCCs) located in different parts of Singapore. The O3 concentrations ranged from 0.1 to 11.95 parts per billion (ppb) in indoor and from 3.2 to 21.7 ppb in outdoor environments during the study period. It was found that, among the CCCs investigated in this study, air-conditioned CCCs and those located in close proximity to traffic emissions had significantly lower O3 concentrations indoors.  相似文献   

15.
Ambient observations have indicated that high concentrations of ozone observed in the Houston/Galveston area are associated with plumes of highly reactive hydrocarbons, mixed with NOx, from industrial facilities. Ambient observations and industrial process data, such as mass flow rates for industrial flares, indicate that the VOCs associated with these industrial emissions can have significant temporal variability. To characterize the effect of this variability in emissions on ozone formation in Houston, data were collected on the temporal variability of industrial emissions or emission surrogates (e.g., mass flow rates to flares). The observed emissions variability was then used to construct regionwide emission inventories with variable industrial emissions, and the impacts of the variability on ozone formation were examined for two types of meteorological conditions, both of which lead to high ozone concentrations in Houston. The air quality simulations indicate that variability in industrial emissions has the potential to cause increases and decreases of 10–52 ppb (13–316%), or more, in ozone concentration. The largest of these differences are restricted to regions of 10–20 km2, but the variability also has the potential to increase regionwide maxima in ozone concentrations by up to 12 ppb.  相似文献   

16.
Conservative models were used to estimate the airborne concentrations of 2,3,7,8 tetrachlorodibenzo-p-dioxin (TCDD) vapor and particulates originating from soil containing 100 ppb TCDD. The upper-bound estimates were 3.25 pg/m3 of airborne TCDD vapor on-site and 0.51 pg/m3 for TCDD vapor 100 meters downwind. The TCDD air concentration on-site due to suspended particulate is estimated to be 1.4 pg/m3, based on a TSP level of 0.07 mg/m3. Assuming 70 years of continuous exposure to these concentrations, the upper-bound cancer risks determined from the Jury model were estimated to be 9.4 × 10−6 to 1.1 × 10−4 and 1.5 × 10−6 to 1.7 × 10−5 for inhalation of on- and off-site vapor, respectively, and 4.1 × 10−6 to 4.6 × 10−5 for dust inhalation. Since few sites have average soil concentrations as high as 100 ppb TCDD, this worst-case analysis indicates that inhalation will rarely, if ever, be a significant route of exposure to TCDD-contaminated soil. Experimental results support this claim and point to much lower risk estimates (8.4 × 10−9 to 9.9 × 10−8), suggesting that the parameters used in the Jury model are likely to overestimate the actual airborne levels of TCDD at contaminated sites.  相似文献   

17.
We developed a diffusive sampling device (DSD-carbonyl) for organic carbonyl compounds (aldehydes and ketones) which is suitable for collection and analysis of low concentration levels. This sampling device is composed of three parts, an exposure part made of a porous polytetrafluoroethylene (PPTFE) tube, an analysis part made of polypropylene (PP) tubing and an absorbent part made of 2,4-dinitrophenylhydrazine (DNPH) coated silica gel (DNPH-silica). Aldehydes and ketones diffuse to the DSD-carbonyl through PPTFE-tube by the mechanism of molecular diffusion and react specifically with DNPH to form a stable DNPH-derivatives. Collection is controlled by moving the absorbent from the exposure part to the analysis part by changing the posture of the DSD-carbonyl. DNPH-derivatives were eluted from an analysis part of DSD-carbonyl with acetonitrile directly and analyzed by high performance liquid chromatography (HPLC). The advantages of the DSD-carbonyl are the following: (1) The DSD-carbonyl can be used in a wide range of concentration of aldehydes and ketones in atmosphere, as the DSD-carbonyl exposure part has a variable diffusion area, (2) DNPH-derivatives are eluted from DNPH-silica without contamination of air. (3) The sampler can be applied to active sampling by connecting it with a pump. The limit of detection (LOD) for concentrations of major aldehydes and ketones ranged from 0.072 to 0.13 ppb, and the limit of quantitation (LOQ) ranged from 0.24 to 0.42 ppb. The coefficient variation (CV) for concentrations of major aldehydes and ketones ranged from 2.5 to 3.0% in laboratory air. The DSD-carbonyl method and active sampling method (US EPA method IP-6A) showed a good correlation (formaldehyde, r2=0.995). The uptake rates for formaldehyde, acetaldehyde, and acetone were estimated as 0.078, 0.062 and 0.079 nmol ppb-1 h-1, respectively. It is possible to estimate atmospheric aldehydes and ketones at parts per billion (ppb), with high sensitivity and precision, by using DSD-carbonyl.  相似文献   

18.
Ozone concentrations at a rural-remote site in a forested region of north-central West Virginia were monitored during 1988 and 1989, a drought and wet year, respectively. During 1988, the absolute maximum average concentration for a single hour was 156 ppb, while it was only 107 ppb in 1989. Overall, the frequency of high concentrations was greater during 1988; the 120 ppb National Ambient Air Quality Standard was exceeded 17 times. The 7-h period encompassing the highest growing season concentrations for this site over the 2-yr period is 1100- 1759 h EST, rather than the period 0900-1559 h originally used by the National Crop Loss Assessment Network. The 7-h growing season means (0900-1559 h) of 52.6 ppb and 47.1 ppb for 1988 and 1989, respectively, compare well to those reported for the Piedmont/Mountain/Ridge-Valley area, but are higher than those for other surrounding areas. The diurnal ozone patterns, as well as the distribution of concentration ranges and timing of seasonal maxima, suggest that long-range transport of ozone and its precursors probably is an important factor at this site, given its remote and rural character.  相似文献   

19.
To estimate plausible health effects associated with peak sulfur dioxide (SO2) levels from three coal-fired power plants in the Baltimore, Maryland, area, air monitoring was conducted between June and September 2013. Historically, the summer months are periods when emissions are highest. Monitoring included a 5-day mobile and a subsequent 61-day stationary monitoring study. In the stationary monitoring study, equipment was set up at four sites where models predicted and mobile monitoring data measured the highest average concentrations of SO2. Continuous monitors recorded ambient concentrations each minute. The 1-min data were used to calculate 5-min and 1-hr moving averages for comparison with concentrations from clinical studies that elicited lung function decrement and respiratory symptoms among asthmatics. Maximum daily 5-min moving average concentrations from the mobile monitoring study ranged from 70 to 84 ppb (183–220 µg/m3), and maximum daily 1-hr moving average concentrations from the mobile monitoring study ranged from 15 to 24 ppb (39–63 µg/m3). Maximum 5-min moving average concentrations from stationary monitoring ranged from 39 to 229 ppb (102–600 µg/m3), and maximum daily 1-hr average concentrations ranged from 15 to 134 ppb (40–351 µg/m3). Estimated exposure concentrations measured in the vicinity of monitors were below the lowest levels that have demonstrated respiratory symptoms in human clinical studies for healthy exercising asthmatics. Based on 5-min and 1-hr monitoring, the exposure levels of SO2 in the vicinity of the C.P. Crane, Brandon Shores, and H.A. Wagner power plants were not likely to elicit respiratory symptoms in healthy asthmatics.

Implications: Mobile and stationary air monitoring for SO2 were conducted to quantify short-term exposure risk, to the surrounding community, from peak emissions of three coal-fired power plants in the Baltimore area. Concentrations were typically low, with only a few 5-min averages higher than levels indicated during clinical trials to induce changes in lung capacity for healthy asthmatics engaged in exercise outdoors.  相似文献   

20.
Abstract

Sources and concentrations of indoor nitrogen dioxide (NO2) were examined in Barcelona, Spain, during 1996– 1999. A total of 340 dwellings of infants participating in a hospital-based cohort study were selected from different areas of the city. Passive filter badges were used for indoor NO2 measurement over 7–30 days. Dwelling inhabitants completed a questionnaire on housing characteristics and smoking habits. Data on outdoor NO2 concentrations were available for the entire period of the study in the areas of the city where indoor concentrations were determined. Bivariate analysis was performed to investigate relationships between indoor NO2 concentrations on one hand and outdoor NO2 concentrations, housing, and occupant characteristics on the other. Stepwise multiple linear regression was performed with variables that were 1996 and 27.02 ppb in 1999, with the highest yearly value of 27.82 ppb in 1997. In the same time period, mean outdoor NO2 concentration ranged between 25.26 and 25.78 ppb with a peak of 30.5 ppb in 1998. Multiple regression analysis showed that principal sources of indoor NO2 concentrations were the use of a gas cooker, the absence of an extractor fan when cooking, and cigarette smoking. The absence of central heating was also associated with higher NO2 concentrations. Finally, each ppb increase in outdoor NO2 was associated with a 1% increase in indoor concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏