首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The concentrations of cadmium, cobalt, chromium, copper, iron, manganese, nickel, lead, and zinc were determined by ICP-AES in muscles and livers of eight fish species sampled from the Aegean and Mediterranean seas of Turkey. Iron showed the highest levels, followed by Zinc in examined tissues of all fish species. Metal concentrations in edible parts of fish species were 0.03–0.37 mg kg???1 for cadmium, 0.02–0.42 mg kg???1 for cobalt, 0.15–1.78 mg kg???1 for chromium, 0.17–1.11 mg kg???1 for copper, 11.0–33.4 mg kg???1 for iron, 0.02–0.89 mg kg???1 for manganese, 0.22–4.03 mg kg???1 for nickel, 0.22–0.64 mg kg???1 for lead, and 2.88–10.9 mg kg???1 for zinc, respectively. All metal concentrations in livers were higher than those in muscles. In some stations, cadmium, chromium, cobalt, and lead concentrations in both muscles and livers of the examined species were higher than permissible safety levels for human uses.  相似文献   

2.
Organically produced, harvested, and dried fruit samples bought at organic markets in Kayseri, Turkey have been analyzed for their trace element contents. In the determinations, flame atomic absorption spectrometer (FAAS) was used. This pilot study is the first to be performed for organically produced, harvested, and dried fruit samples from Kayseri, Turkey. The copper, iron, manganese, and zinc concentrations were found to be 1.6–15.5, 10.3–144, 23.0–211, and 23.3–91.6 μg/g, respectively. The cobalt, lead, cadmium, chromium, and nickel concentrations in all analyzed organic fruit samples were below the quantification limits of FAAS. SRM 1570A spinach leaves and SRM 1515 apple leaves were used to check the accuracy of the procedure. The results for the dried fruit samples found in this work were compared with the values from some studies from the world. The results found in the presented work may also be useful for future studies about organically produced, harvested, and dried fruit samples.  相似文献   

3.
This study was performed to investigate the metal concentrations in muscle, liver, gonad, and gill of gilthead seabream (Sparus aurata L., 1758), European seabass (Dicentrarchus labrax L., 1758), and keeled mullet (Liza carinata Valenciennes, 1836) from Yelkoma Lagoon, northeastern Mediterranean region. So, the levels of cadmium, cobalt, chromium, copper, iron, manganese, nickel, lead, and zinc in tissues of specimens from the lagoon were determined by inductively coupled plasma optical emission spectrometer. Concentrations of metals in muscles of the examined species ranged from 0.10 to 0.47 mg kg???1 for cadmium, 0.10 to 0.43 mg kg???1 for cobalt, 0.17 to 0.72 mg kg???1 for chromium, 0.62 to 1.03 mg kg???1 for copper, 28.9 to 52.3 mg kg???1 for iron, 0.75 to 0.96 mg kg???1 for manganese, 0.11 to 0.57 mg kg???1 for nickel, 0.19 to 0.47 mg kg???1 for lead, and 6.01 to 13.9 mg kg???1 for zinc, respectively. Additionally, metal concentrations in muscles of fish were assessed for human uses according to provisional tolerable weekly intake and provisional tolerable daily intake.  相似文献   

4.
Trace element content of marine algae species collected from the Black Sea coasts were determined by atomic absorption spectroscopy after microwave digestion. Trace element content in marine algae species were 1.70-17.1 microg/g for copper, 3.64-64.8 microg/g for zinc, 9.98-285 microg/g for manganese, 99-3,949 microg/g for iron, 0.50-11.6 microg/g for chromium, 0.27-36.2 microg/g for nickel, 11-694 microg/kg for selenium, 0.50-44.6 microg/kg for cadmium, 1.54-3,969 microg/kg for lead, 1.56-81.9 microg/kg for cobalt. While iron was the highest trace element concentration, cadmium was the lowest in samples. Most of the analyzed samples were edible. The samples are consumed for human diet in several countries.  相似文献   

5.
The trace element contents of seven kinds of herbal plants and spice samples retailed in local markets in Kayseri-Turkey were determined by flame atomic absorption spectrometry after digestion with HNO3/H2O2 mixture. The concentration ranges for the studied elements were found as 6.0–15.2, 0–32.2, 80.0–324.8, 8.1–386.3, and 13.1–36.2 μg/g for copper, nickel, iron, manganese, and zinc, respectively. The levels of cobalt, lead, and chromium ions in all the investigated samples were found to be below the detection limit of flame atomic absorption spectrometry. The results found in the present work were compared with values in the literature.  相似文献   

6.
Due to the consumption of the herby cheese in south eastern Anatolia-Turkey is at high ratio, chemical parameters such as dry matter, pH, acidity, aCl, protein, fat and trace metal contents in 50 different herby cheeses produced at this region have been determined in the presented study. The content of lead, copper, cobalt, nickel, chromium, cadmium, and iron have been analyzed by flame atomic absorption spectrometer in air/acetylene flame after combination ash digestion method and wet digestion method. The mean concentration of lead, copper, cobalt, nickel, chromium and cadmium in our samples are higher than literature values except iron.  相似文献   

7.
The present study was conducted to investigate drinking water quality (groundwater) from water samples taken from Qasim Abad, a locality of approximately 5,000 population, situated between twin cities Rawalpindi and Islamabad in Pakistan. The main sources of drinking water in this area are water bores which are dug upto the depth of 250–280 ft in almost every house. The study consists of the determination of physico-chemical properties, trace metals, heavy metals, rare earth elements and microbiological quality of drinking water. The data showed the variation of the investigated parameters in samples as follows: pH 6.75 to 8.70, electrical conductivity 540 to 855 μS/cm, total dissolved solids 325.46 to 515.23 ppm and dissolved oxygen 1.50 to 5.64 mg/L which are within the WHO guidelines for drinking water quality. The water samples were analysed for 30 elements (aluminium, iron, magnesium, manganese, silicon, zinc, molybdenum, titanium, chromium, nickel, tungsten, silver, arsenic, boron, barium, beryllium, cadmium, cobalt, copper, gallium, mercury, lanthanum, niobium, neodymium, lead, selenium, samarium, tin, vanadium and zirconium) by using inductively coupled plasma atomic emission spectroscopy. The organic contamination was detected in terms of most probable number (MPN) of faecal coliforms. Overall, elemental levels were lower than the recommended values but three water bores (B-1, B-6, B-7) had higher values of iron (1.6, 2.206, 0.65 ppm), two water bores (B-1, B-6) had higher values of aluminium (0.95, 1.92 ppm), respectively, and molybdenum was higher by 0.01 ppm only in one water bore (B-11). The total number of coliforms present in water samples was found to be within the prescribed limit of the WHO except for 5 out of 11 bore water samples (B-2, B-3, B-4, B-8, B-11), which were found in the range 5–35 MPN/100 mL, a consequence of infiltration of contaminated water (sewage) through cross connection, leakage points and back siphoning.  相似文献   

8.
密闭微波消解 ICP- AES 法测定大气颗粒物中金属元素   总被引:2,自引:1,他引:1       下载免费PDF全文
采用过氯乙烯滤膜采集、密闭微波消解、电感耦合等离子发射光谱法测定大气颗粒物中铅、镍、铬、铜、铁、锌、锰、钡、镉,优化了试验条件.方法线性良好,各元素的检出限在0.001 mg/L~0.01 mg/L之间,滤膜样品测定的RSD为0.6%~2.9%,加标回收率为96.0%~105%.  相似文献   

9.
In this study, the levels of natural and anthropogenic metal contamination (aluminum (Al), iron (Fe), manganese (Mn), arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn)) in surface sediments of three harbors along the Iranian coast of Gulf of Oman were examined and reported for the first time. Effect of grain size, mineralogy, normalization technique using Fe concentrations, and different sediment quality guidelines were discussed. Data from the harbors were compared with other harbors worldwide. Sediments inside the harbors are characterized by moderate and high levels of pollution by trace metals Cu (12–287 μg/g), Pb (11–1,780 μg/g), Zn (38–547 μg/g), Cr (70–2,370 μg/g), and Ni (31–116 μg/g). However, As and Cd did not show considerable pollution inside and outside the harbors. Considering that there is no industrial activity around the study harbors, the major sources of contamination in the harbors are repairing, fueling, greasing, and painting of fishing ships and boats. Mineralogy of sediments in the study area as well as trace metal concentration in reference samples taken from onshore geological units confirmed that natural inputs of Cd, Cu, Pb, and Zn in the harbors are very low while most of Ni and Cr contamination in the study area comes from erosion of ophiolitic mélange units at the North of Makran mountains.  相似文献   

10.
Hussainsagar Lake in the heart of Hyderabad City (India) receives toxic substances through five streams draining from a catchment area of 245 km2. Of particular interest are heavy metals received from urban runoff as well as municipal sewage and industrial effluents. Heavy metals entering the lake get adsorbed onto the suspended sediments, which eventually settle down in the bottom of the lake. In this study, fractionation of metal ions has been studied on the bed sediments of Hussainsagar Lake in order to determine the ecotoxic potential of metal ions. Comparison of sediments with average shale values indicated anthropogenic enrichment with copper, nickel, lead, cadmium, and zinc. The risk assessment code as applied to the present study reveals that 10–17% of manganese, 10–18% of nickel, 14–24% of chromium, 10–19% of lead, 21–30% of cadmium, and 18–28% of zinc exist in exchangeable fraction and, therefore, comes under medium risk category and may enter into food chain. The association of these metals with the exchangeable fraction may cause deleterious effects to aquatic life. The present database will help in formulating guidelines for carrying out dredging operations under restoration programs in the Hussainsagar Lake.  相似文献   

11.
The Tsurumi, a class-one Japanese river, has a significant metal loading originating from urban environment. Water and sediment samples were collected from 20 sites in winter and summer, 2009 and were analyzed to determine and compare the extent of different trace element enrichment. A widely used five-step sequential extraction procedure was also employed for the fractionation of the trace elements. Concentrations of zinc, copper, lead, chromium, and cadmium were three to four times higher than that of reference values and downstream sediments are much more polluted than the upstream sites. Geochemical partitioning results suggest that the potential trace metal mobility in aquatic environment was in the order of: cadmium > zinc > lead > copper > cobalt > chromium > molybdenum > nickel. About 80.2% zinc, 77.9% molybdenum, 75.3% cobalt, 63.7% lead, 60.9% copper, 55.1% chromium, and 39.8% nickel in the sediment were contributed anthropogenically. According to intensity of pollution, Tsurumi river sediments are moderately to heavily contaminated by zinc, lead, and cobalt. Enrichment factor values demonstrated that zinc, lead, and molybdenum have minor enrichment in both the season. The pollution load index (PLI) has been used to access the pollution load of different sampling sites. The area load index and average PLI values of the river were 7.77 and 4.93 in winter and 7.72 and 4.89 in summer, respectively. If the magnitude of pollution with trace metal in the river system increases continuously, it may have a severe impact on the river’s aquatic ecology.  相似文献   

12.
Water samples from 30 rivers in northern and north-eastern hilly states of India were analysed for bacteriological and physicochemical parameters along with metals and pesticide residues. It was found that 34% of samples had >50 coliforms/100 ml, while 24% of samples demonstrated >50 thermotolerant (faecal) coliforms/100 ml. Among the metals, iron was found to be above maximum permissible limits in the rivers of all the states, while manganese was found to be above the maximum permissible limit in the rivers of Tripura and some northern states. Zinc, lead, nickel, chromium, copper, cobalt and cadmium plus physicochemical parameters and residual pesticides, however, were within their maximum permissible limits.  相似文献   

13.
The aim of this study was to determine the total metal accumulation (aluminium, copper, manganese, lead, cadmium and iron) in different organs and eggs of Astacus leptodactylus (Eschscholtz, 1823) and sediments total metal contents (aluminium, copper, manganese, lead, cadmium, iron, zinc, chromium, nickel) in Lake Terkos. Water and sediment samples were collected from two stations at two different depths (1 and 2 m) of Lake Terkos in May 2008. Crayfish samples were collected by trammel net at the same region. Primary hydrographic conditions, such as temperature (13.6–19.4°C), salinity (0.27–0.34‰), dissolved oxygen (7.04–12.30 mg l???1) and pH (7.42–8.51), were recorded for each sampling point. Moreover, the total organic carbon (1.65–5.44%) and the total calcium carbonate contents (19.44–41.16%) of sediment samples were determined. According to the Turkish Food Codex (J Zool 26:283–288, 2002), the maximum allowable Pb and Cd levels in crayfish are 0.5 mg/kg wet weight. Accordingly, the Pb and Cd levels determined in A. leptodactylus samples are below this limit. However, when compared with the acceptable metal limits defined by WHO, Australian National Health and Medical Research Council and Ministry of Agriculture in United Kingdom (UK), it is clear that the Cu level is at the limit and the Cd results exceed the limit. When the metal contents in sediment samples from Lake Terkos are examined, it is seen that the Al, Fe, Mn, Ni and Cu contents are lower while Zn, Cr, Cd and Pb contents are higher than the crustal average values. The high values draw attention to the land-based domestic and industrial inputs. Lake Terkos sediments have high enrichment factors (EF) of Zn, Cr, Cd and Pb metals which corroborate this result. The low EFs of Fe, Ni and Cu are due to the natural (terrigeneous) inputs. Additionally, there is no Al, Fe, Ni and Cu metal enrichment in these lake sediments because of the low contamination factor (CF) values. However, it is moderately contaminated by Zn, Cr and Pb, and heavily contaminated by Cd.  相似文献   

14.
应用电感耦合等离子体质谱法对水样(地表水、饮用水等)中铜、锌、硒、砷、镉、铬、铅、铁、锰等痕量元素进行分析测定。结果表明,方法检出限为0.01~0.78μg/L,平行测定的相对标准偏差为0.6%~7.9%,实际水样加标回收率为90.5%~103%。该方法快速、简便、线性范围大,具有良好的检出限和准确度。  相似文献   

15.
Twenty-three soft drink samples (i.e., four pineapple-based fruit drinks, eight citrus-based fruit juices, one soya-based drink, three cola carbonated drinks, one apple-based fruit drink, and six cocktail fruit drinks) were randomly purchased from retail outlets in an urban market in Accra and analyzed for the concentrations of iron, cobalt, cadmium, zinc, lead, and copper using flame atomic absorption spectrometry. The mean concentration of iron and cadmium were 0.723?±?0.448 mg/L and 0.032?±?0.012 mg/L, respectively. The mean cobalt concentration was 0.071?±?0.049 mg/L, while the mean Zn concentration in the samples was 0.060?±?0.097 mg/L. The mean concentrations of Pb and Cu in the fruit juice samples were 0.178?±?0.091 mg/L and 0.053?±?0.063 mg/L respectively. About 78 % of the samples exceeded the United States Environmental Protection Agency (USEPA) maximum contaminant level of 0.3 mg/L prescribed for iron, whereas all the samples exceeded the USEPA maximum contaminant level of 0.005 mg/L prescribed for cadmium. About 91 % of the samples exceeded the EU maximum contaminant level prescribed for lead insoft drinks.  相似文献   

16.
Eight heavy metals (Cu, Zn, Fe, Mn, Cd, Cr, Ni, and Pb) in 14 different wild-growing edible mushroom species (Coprinus comatus, Voluariella volvacea, Pleurotus nebrodensis, Hypsizigus marmoreus, Hericium erinaceus, Agrocybe aegerita, Lenfinus edodes, Collybia velutipes, Agaricus bisporus, Russula albida, Clitocybe conglobata, Pleurotus eryngii, Lepista sordida, and Pleurotus ostreatus) collected from Yunnan province, China, were determined by inductively coupled plasma-atomic emission spectrometry after microwave digestion. All element concentrations were determined on a dry weight basis. The ranges of element concentrations for copper, zinc, iron, manganese, cadmium, chromium, nickel, and lead were 6.8-31.9, 42.9-94.3, 67.5-843, 13.5-113, 0.06-0.58, 10.7-42.7, 0.76-5.1, and 0.67-12.9 mg/kg, respectively. In general, iron content was higher than other metals in all mushroom species. The levels of zinc, cadmium, and lead in some edible mushroom samples were found to be higher than legal limits. The relative standard deviations were found below 10%. The accuracy of procedure was confirmed by certified reference material.  相似文献   

17.
Sweet potatoes are a staple in the diet of some people and an excellent source of minerals. Metal monitoring in food, like sweet potatoes, provides basic information on safety aspects in regulatory processes as well as nutritional values. One hundred five samples of three varieties of sweet potatoes were randomly obtained from supermarkets, farmers markets, and farmers' plots in Tenerife (Canary Islands, Spain). The edible portion (pulp) was the only part considered for analysis. Flame atomic absorption spectrometry was used to determine the contents of sodium (Na), potassium (K), calcium (Ca), magnesium (Mg), copper (Cu), iron (Fe), manganese (Mn), and zinc (Zn), while the levels of chromium (Cr), nickel (Ni), cadmium (Cd), and lead (Pb) were determined using graphite furnace atomic absorption spectrometry. The mean concentrations were 500 Na, 4409 K, 564 Ca, 609 Mg, 1.291 Cu, 6.554 Fe, 2.324 Mn, 2.348 Zn, 0.028 Cr, 0.048 Ni, 0.001 Cd, and 0.003 Pb mg/kg, respectively. Potassium presented the highest contents in all varieties of sweet potatoes. Iron was the most abundant microelement. The orange fleshed sweet potato variety offered greater nutritional contributions to the recommended intakes than the rest of the varieties studied. The estimated mean daily intake of Ni (0.72 mg/day) detected in our samples was highly consistent with other studies. Average daily intakes of Cd (0.015 μg/day) and Pb (0.045 μg/day) were below toxicological reference values. In conclusion, the levels of Cd and Pb detected in the sweet potatoes analyzed do not represent any toxicological risk to consumers.  相似文献   

18.
Cadmium, chromium, iron, manganese, nickel, lead and zinc concentrations were determined in sediment and body tissues, viz. digestive gland, mantle and shell, of the freshwater snail, Angulyagra oxytropis (Benson) (Gastropoda : Viviparidae), from River Barak and one of its floodplain lakes in Cachar district, Assam State, Northeastern India. The concentrations of all the metals except iron are significantly higher in the lake sediment. When compared to their riverine counterparts, the lacustrine snails contain higher concentrations of cadmium, chromium and iron in their mantle; nickel and zinc in digestive gland; manganese in both digestive gland and mantle; and lead in all the three tissues examined. The accumulation patterns of most of the metals varied considerably between the two sites. The implications of these findings in storage, sequestration and detoxification of metals by this animal are discussed. The study also indicates that A. oxytropis may be a potential biological indicator of metal contamination in freshwater ecosystems.  相似文献   

19.
This study assessed the level of heavy metal in roadside dust and PM2.5 mass concentrations along Thika superhighway in Kenya. Thika superhighway is one of the busiest roads in Kenya, linking Thika town with Nairobi. Triplicate road dust samples collected from 12 locations were analysed for lead (Pb), chromium (Cr), cadmium (Cd), nickel (Ni), zinc (Zn), and copper (Cu) using atomic absorption spectrophotometry (AAS). PM2.5 samples were collected on pre-weighed Teflon filters using a BGI personal sampler and the filters were then reweighed. The ranges of metal concentrations were 39–101 μg/g for Cu, 95–262 μg/g for Zn, 9–28 μg/g for Cd, 14–24 μg/g for Ni, 13–30 μg/g for Cr, and 20–80 μg/g for Pb. The concentrations of heavy metals were generally highly correlated, indicating a common anthropogenic source of the pollutants. The results showed that the majority of the measured heavy metals were above the background concentration, and in particular, Cd, Pb, and Zn levels indicated moderate to high contamination. Though not directly comparable due to different sampling timeframes (8 h in this study and 24 h for guideline values), PM2.5 for all sites exceeds the daily WHO PM2.5 guidelines of 25 μg/m3. This poses a health risk to people using and working close to Thika superhighway, for example, local residents, traffic police, street vendors, and people operating small businesses. PM2.5 levels were higher for sites closer to Nairobi which could be attributed to increased vehicular traffic towards Nairobi from Thika. This study provides some evidence of the air pollution problem arising from vehicular traffic in developing parts of the world and gives an indication of the potential health impacts. It also highlights the need for source apportionment studies to determine contributions of anthropogenic emissions to air pollution, as well as long-term sampling studies that can be used to fully understand spatiotemporal patterns in air pollution within developing regions.  相似文献   

20.
A new method for the determination of iron, cobalt, nickel, copper, zinc and manganese in drinking water by the reversed-phase high-performance liquid chromatography (RP-HPLC) with 2-(2-quinolinylazo)-5-diethylaminophenol (QADEAP) as precolumn derivatizing reagent was studied in this paper. The iron, cobalt, nickel, copper, zinc, and manganese ions react with QADEAP to form color chelates in the presence of cetyl trimethylammonium bromide (CTMAB) and acetic acid-sodium acetic buffer solution medium of pH 4.0. These chelates were enriched by solid-phase extraction with a Waters Nova-Pak C18 cartridge and eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The enrichment factor of 100 was achieved. Then the chelates were separated on a Waters Nova-Pak C18 column (3.9 x 150 mm, 5 microm) by gradient elution with methanol (containing 0.2% of acetic acid and 0.1% of CTMAB) and 0.05 mol L(-1) acetic acid-sodium acetic buffer solution (containing 0.1% of CTMAB) (pH 4.0) as mobile phase at a flow rate of 0.5 ml min(-1), and monitored with a photodiode array detector from 450 approximately 700 nm. The detection limits (S/N = 3) of iron, cobalt, nickel, copper, zinc and manganese are 0.8, 1.1, 0.9, 1.1, 1.5 and 2.0 ng L(-1), respectively, in the original sample. This method can be applied to determination at the microg L(-1) level of iron, cobalt, nickel, copper, zinc and manganese in drinking water with good results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号