首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 575 毫秒
1.
A mobile exposure and air pollution measurement system was developed and used for on-freeway ultrafine particle health effects studies. A nine-passenger van was modified with a high-efficiency particulate air (HEPA) filtration system that can deliver filtered or unfiltered air to an exposure chamber inside the van. State-of-the-art instruments were used to measure concentration and size distribution of fine and ultrafine particles and the concentration of carbon monoxide (CO), black carbon (BC), particle-bound polycyclic aromatic hydrocarbons (PAHs), fine particulate matter (PM2.5) mass, and oxides of nitrogen (NOx) inside the exposure chamber. This paper presents the construction and technical details of the van and air pollutant concentrations collected in 32 2-hr runs on two major Los Angeles freeways, Interstate 405 (1-405; mostly gasoline traffic) and Interstate 710 (1-710; large proportion of heavy-duty diesel traffic). More than 97% of particles were removed when the flow through the filter box was switched from bypass mode to filter mode while the vehicle was driving on both freeways. The filtration system thus provides a great particulate matter exposure contrast while keeping gas-phase pollutant concentrations the same. Under bypass mode, average total particle number concentration observed inside the exposure chamber was around 8.4 x 10(4) and 1.3 x 10(5) particles cm(-3) on the I-405 and the I-710 freeways, respectively. Bimodal size distributions were consistent and similar for both freeways with the first mode around 16-20 nm and the second mode around 50-55 nm. BC and particle-bound PAH concentrations were more than two times greater on the I-710 than on the I-405 freeway. Very weak correlations were observed between total particle number concentrations and other vehicular pollutants on the freeways.  相似文献   

2.
Abstract

Motor vehicle emissions usually constitute the most significant source of ultrafine particles (diameter <0.1 μm) in an urban environment, yet little is known about the concentration and size distribution of ultrafine particles in the vicinity of major highways. In the present study, particle number concentration and size distribution in the size range from 6 to 220 nm were measured by a condensation particle counter (CPC) and a scanning mobility particle sizer (SMPS), respectively. Measurements were taken 30, 60, 90, 150, and 300 m downwind, and 300 m upwind, from Interstate 405 at the Los Angeles National Cemetery. At each sampling location, concentrations of CO, black carbon (BC), and particle mass were also measured by a Dasibi CO monitor, an aethalometer, and a DataRam, respectively. The range of average concentration of CO, BC, total particle number, and mass concentration at 30 m was 1.7?2.2 ppm, 3.4?10.0 μg/m3, 1.3?2.0 × 105/cm3, and 30.2?64.6 μ/m3, respectively.

For the conditions of these measurements, relative concentrations of CO, BC, and particle number tracked each other well as distance from the freeway increased. Particle number concentration (6–220 nm) decreased exponentially with downwind distance from the freeway. Data showed that both atmospheric dispersion and coagulation contributed to the rapid decrease in particle number concentration and change in particle size distribution with increasing distance from the freeway. Average traffic flow during the sampling periods was 13,900 vehicles/hr. Ninety-three percent of vehicles were gasoline-powered cars or light trucks. The measured number concentration tracked traffic flow well. Thirty meters downwind from the freeway, three distinct ultrafine modes were observed with geometric mean diameters of 13, 27, and 65 nm. The smallest mode, with a peak concentration of 1.6 × 105/cm3, disappeared at distances greater than 90 m from the freeway. Ultrafine particle number concentration measured 300 m downwind from the freeway was indistinguishable from upwind background concentration. These data may be used to estimate exposure to ultrafine particles in the vicinity of major highways.  相似文献   

3.
Increasing epidemiological evidence has established an association between a host of adverse health effects and exposure to ambient particulate matter (PM) and co-pollutants, especially those emitted from motor vehicles. Although PM and their co-pollutants dispersion profiles near the open freeway have been extensively characterized by means of both experimental measurements and numerical simulations in recent years, such investigations near freeways with roadside barriers have not been well documented in the literature. A few previous studies suggested that the presence of roadside structures, such as noise barriers and vegetation, may impact the decay of pollutant concentrations downwind of the freeway by limiting the initial dispersion of traffic emissions and increasing their vertical mixing due to the upward deflection of airflow. Since the noise barriers are now common roadside features of the freeways, particularly those running through populated urban areas, it is pertinent to investigate the impact of their presence on the particles and co-pollutants concentrations in areas adjacent to busy roadways. This study investigated two highly trafficked freeways (I-710 and I-5) in Southern California, with two sampling sites for each freeway, one with and the other without the roadside noise barriers. Particle size distributions and co-pollutants concentrations were measured in the immediate proximity of freeways and at different distances downwind of the freeways. The results showed the formation of a “concentration deficit” zone in the immediate vicinity of the freeway with the presence of roadside noise barrier, followed by a surge of pollutant concentrations further downwind at 80–100 m away from freeway. The particle and co-pollutants concentrations reach background levels at farther distances of 250–400 m compared to 150–200 m at the sites without roadside noise barriers.  相似文献   

4.
During February–March 2006, a major field sampling campaign was conducted adjacent to the Interstate 710 (I-710) freeway in Los Angeles, CA. I-710 has high traffic volumes (ca. 11,000 vehicles h−1) and a high percentage (17–18%) of heavy-duty diesel vehicle (HDDV) traffic. The volatility of ambient particles of 20, 40, 80 and 120 nm in diameter was investigated using a Tandem Differential Mobility Analyzer (TDMA) at two locations—close to the freeway (10 m) and approximately 150 m downwind. The smallest particles (20 nm) are largely volatile at both locations. Larger particles, e.g., ⩾40 nm) showed evidence of external mixing, with the non-volatile fraction increasing with particle size. Particle volatility increased with decreasing ambient temperature. The HDDVs contribute to relatively larger non-volatile particle number and volume fractions and greater external mixing than earlier observations at a pure light-duty gasoline vehicle freeway [Kuhn et al., 2005c. Atmospheric Environment 39, 7154–7166]. Finally, the fraction of externally mixed soot particles decreased as the downwind distance increased from the I-710, due to atmospheric processes such as vapor adsorption and condensation as well as particle coagulation.  相似文献   

5.
Personal exposure studies are crucial alongside microenvironment and ambient studies in order to get a better understanding of the health risks posed by fine particulate matter and carbon monoxide in the urban transport microenvironment and for making informed decisions to manage and reduce the health risks. Studies specifically assessing the PM2.5, ultrafine particle count and carbon monoxide personal exposure concentrations of adults in an urban transport microenvironment have steadily increased in number over the last decade. However, no recent collective summary is available, particularly one which also considers ultrafine particles; therefore, we present a review of the personal exposure concentration studies for the above named pollutants on different modes of surface transportation (walking, cycling, bus, car and taxi) in the urban transport microenvironment. Comparisons between personal exposure measurements and concentrations recorded at fixed monitoring sites are considered in addition to the factors influencing personal exposure in the transport microenvironment.In general, the exposure studies examined revealed pedestrians and cyclists to experience lower fine particulate matter and CO exposure concentrations in comparison to those inside vehicles—the vehicle shell provided no protection to the passengers. Proximity to the pollutant sources had a significant impact on exposure concentration levels experienced, consequently individuals should be encouraged to use back street routes. Fixed monitoring stations were found to be relatively poor predictors of CO and PM2.5 exposure concentration levels experienced by individuals in the urban transport microenvironment. Although the mode of transport, traffic and meteorology parameters were commonly identified as significant factors influencing exposure concentrations to the different pollutants under examination, a large amount of the exposure concentration variation in the exposure studies remained unexplained.  相似文献   

6.
Increasing evidence has demonstrated toxic effects of vehicular emitted ultrafine particles (UFPs, diameter < 100 nm), with the highest human exposure usually occurring on and near roadways. Children are particularly at risk due to immature respiratory systems and faster breathing rates. In this study, children’s exposure to in-cabin air pollutants, especially UFPs, was measured inside four diesel-powered school buses. Two 1990 and two 2006 model year diesel-powered school buses were selected to represent the age extremes of school buses in service. Each bus was driven on two routine bus runs to study school children’s exposure under different transportation conditions in South Texas. The number concentration and size distribution of UFPs, total particle number concentration, PM2.5, PM10, black carbon (BC), CO, and CO2 levels were monitored inside the buses. The average total particle number concentrations observed inside the school buses ranged from 7.3 × 103 to 3.4 × 104 particles cm?3, depending on engine age and window position. When the windows were closed, the in-cabin air pollutants were more likely due to the school buses’ self-pollution. The 1990 model year school buses demonstrated much higher air pollutant concentrations than the 2006 model year ones. When the windows were open, the majority of in-cabin air pollutants came from the outside roadway environment with similar pollutant levels observed regardless of engine ages. The highest average UFP concentration was observed at a bus transfer station where approximately 27 idling school buses were queued to load or unload students. Starting-up and idling generated higher air pollutant levels than the driving state. Higher in-cabin air pollutant concentrations were observed when more students were on board.  相似文献   

7.
Total number concentrations, number concentrations of ultrafine (0.01–0.1 μm) and accumulation (0.1–0.5 μm) particles, as well as mass concentration of PM2.5 particles and blackness of PM2.5 filters, which is related to Black Smoke were simultaneously monitored in three European cities during the winter period for three and a half months. The purpose of the study was to describe the differences in concentration levels and daily and diurnal variations in particle number and mass concentrations between European cities. The results show statistically significant differences in the concentrations of PM2.5 and the blackness of the PM2.5 filters between the cities, but not in the concentrations of ultrafine particles. Daily PM2.5 levels were found to be poorly correlated with the daily total and ultrafine number concentrations but better correlated with the number concentration of accumulation particles. According to the principal component analysis airborne particulate pollutants seem to be divided into two major source categories, one identified with particle number concentrations and the other related to mass-based information. The present results underline the importance of using both particle number and mass concentrations to evaluate urban air quality.  相似文献   

8.
This review describes databases of small-scale spatial variations and indoor, outdoor and personal measurements of air pollutants with the main focus on suspended particulate matter, and to a lesser extent, nitrogen dioxide and photochemical pollutants. The basic definitions and concepts of an exposure measurement are introduced as well as some study design considerations and implications of imprecise exposure measurements. Suspended particulate matter is complex with respect to particle size distributions, the chemical composition and its sources. With respect to small-scale spatial variations in urban areas, largest variations occur in the ultrafine (<0.1 μm) and the coarse mode (PM10–2.5, resuspended dust). Secondary aerosols which contribute to the accumulation mode (0.1–2 μm) show quite homogenous spatial distribution. In general, small-scale spatial variations of PM2.5 were described to be smaller than the spatial variations of PM10. Recent studies in outdoor air show that ultrafine particle number counts have large spatial variations and that they are not well correlated to mass data. Sources of indoor particles are from outdoors and some specific indoor sources such as smoking and cooking for fine particles or moving of people (resuspension of dust) for coarse particles. The relationships between indoor, outdoor and personal levels are complex. The finer the particle size, the better becomes the correlation between indoor, outdoor and personal levels. Furthermore, correlations between these parameters are better in longitudinal analyses than in cross-sectional analyses. For NO2 and O3, the air chemistry is important. Both have considerable small-scale spatial variations within urban areas. In the absence of indoor sources such as gas appliances, NO2 indoor/outdoor relationships are strong. For ozone, indoor levels are quite small. The study hypothesis largely determines the choice of a specific concept in exposure assessment, i.e. whether personal sampling is needed or if ambient monitoring is sufficient. Careful evaluation of the validity and improvements in precision of an exposure measure reduce error in the measurements and bias in the exposure–effect relationship.  相似文献   

9.

Purpose

Various publications indicate that the operation of laser printers and photocopiers may be associated with health effects due to the release of gaseous components and fine and ultrafine particles (UFP). However, only sparse studies are available that evaluate the possible exposure of office workers to printer emissions under real conditions. Therefore, the aim of our study was to assess the exposure of office workers to particulate matter released from laser printers and photocopiers.

Methods

Concentrations of fine particles and UFP were measured before, during, and after the operation of laser printing devices in 63 office rooms throughout Germany. Additionally, the particles were characterized by electron microscopy and energy-dispersive X-ray spectroscopy.

Results

A significant increase of fine particles and UFP was identified in ambient workplace air during and after the printing processes. Particle fractions between 0.23 and 20???m emitted by the office machines significantly affect particle mass concentrations while printing 500 pages, i.e., during the printing process, PM0.23?C20, PM2.5, and PM10 concentrations increased in 43 out of the evaluated 62 office rooms investigated. Additionally, a significant increase was observed in submicrometer particles, with median particle number concentrations of 6,503 particles/cm3 before and 18,060 particles/cm3 during the printing process.

Conclusions

Our data indicate that laser printers and photocopiers could be a relevant source of fine particles and particularly UFP in office rooms.  相似文献   

10.
Individual organic compounds such as hopanes and steranes (originating in lube oil) and selected polycyclic aromatic compounds (PAHs) (generated via combustion) found in particulate emissions from vehicles have proven useful in source apportionment of ambient particulate matter (PM). Detailed information on the size-segregated (ultrafine and accumulation mode) chemical characteristics of organic PM during the winter season originating from a pure gasoline traffic freeway (CA-110), and a mixed-fleet freeway with the highest fraction of heavy-duty diesel vehicles in the state of California (I-710) is reported in this study. Hopanes and steranes as well as high molecular weight PAHs such as benzo(ghi)perylene (BgP) and coronene levels are found comparable near these freeways, while elemental carbon (EC) and lighter molecular weight PAHs are found much elevated near I-710 compared to CA-110. The roadway organic speciation data presented here are compared with the emission factors (EFs) measured in the Caldecott tunnel, Berkeley, CA [Phuleria, H.C., Geller, M.D., Fine, P.M., Sioutas, C., 2006. Size-resolved emissions of organic tracers from light- and heavy-duty vehicles measured in a California roadway tunnel. Environmental Science and Technology 40, 4109–4118] for light-duty vehicles (LDVs) and heavy-duty vehicles. Very good agreement is observed between CA-110 measurements and LDV EFs as well as I-710 measurements and corresponding reconstructed EFs from Caldecott tunnel for hopanes and steranes as well as heavier PAHs such as BgP and coronene. Our results, therefore, suggest that the EFs for hopanes and steranes obtained in tunnel environments, where emissions are averaged over a large vehicle-fleet, enable reliable source apportionment of ambient PM, given the overall agreement between the roadway vs tunnel concentrations of these species.  相似文献   

11.
Because aerosol particle deposition is an important factor in indoor air quality, many empirical and theoretical studies have attempted to understand the process. In this study, we estimated the deposition rate of aerosol particles on smooth aluminum surfaces inside a test chamber. We investigated the influence of turbulent intensity due to ventilation and fan operation. We also investigated two important processes in particle deposition: turbophoresis, which is significant for micron particles, and coagulation, which is relevant to ultrafine particles (UFP diameter <0.1 μm) at high particle concentrations. Our analysis included semi-empirical estimates of the deposition rates that were compared to available deposition models and verified with simulations of an aerosol dynamics model. In agreement with previous studies, this study found that induced turbulent intensity greatly enhanced deposition rates of fine particles (FP diameter <1 μm). The deposition rate of FP was proportional to the ventilation rate, and it increased monotonically with fan speed. With our setup, turbophoresis was very important for coarse particles larger than 5 μm. The coagulation of aerosol particles was insignificant when the particle concentration was less than 104 cm?3 during fan operation. The model simulation results verified that the aerosol dynamics module incorporated in our Multi-Compartment and Size-Resolved Indoor Aerosol Model (MC-SIAM) was valid. The behavior of aerosol particles inside our chamber was similar to that found in real-life conditions with the same ventilation rates (0.018–0.39 h?1) and similar air mixing modes. Therefore, our findings provide insight into indoor particle behavior.  相似文献   

12.
ABSTRACT

A comprehensive indoor particle characterization study was conducted in nine Boston-area homes in 1998 in order to characterize sources of PM in indoor environments. State-of-the-art sampling methodologies were used to obtain continuous PM2.5 concentration and size distribution particulate data for both indoor and outdoor air. Study homes, five of which were sampled during two seasons, were monitored over week-long periods. Among other data collected during the extensive monitoring efforts were 24hr elemental/organic carbon (EC/OC) particulate data as well as semi-continuous air exchange rates and time-activity information.

This rich data set shows that indoor particle events tend to be brief, intermittent, and highly variable, thus requiring the use of continuous instrumentation for their characterization. In addition to dramatically increasing indoor PM25 concentrations, these data demonstrate that indoor particle events can significantly alter the size distribution and composition of indoor particles. Source event data demonstrate that the impacts of indoor activities are especially pronounced in the ultrafine (da < 0.1 um) and coarse (2.5 < da < 10 |um) modes. Among the sources of ultrafine particles characterized in this study are indoor ozone/terpene reactions. Furthermore, EC/OC data suggest that organic carbon is a major constituent of particles emitted during indoor source events. Whether exposures to indoor-generated particles, particularly from large short-term peak events, may be associated with adverse health effects will become clearer when biological mechanisms are better known.  相似文献   

13.
This study measured ultrafine particle (UFP) levels and their size distributions in the Hsuehshan tunnel from August 12 to 19, 2009, using a Fast Mobility Particle Sizer. Measurement results demonstrate that traffic volume, the slope of the tunnel (downhill or uphill) and the ventilation system affected UFP levels inside the tunnel. Average UFP levels were about 1.0 × 105–3.0 × 105 particles cm?3 at normal traffic volume. A traffic jam in the tunnel could raise UFP levels to over 1.0 × 106 particles cm?3. UFP levels at the uphill bore were significantly higher than those at the downhill bore due to high UFP levels exhausted from vehicles going uphill at high engine load conditions. UFP levels eventually diluted 10–50% with fresh air from tunnel air shafts. Gas-to-particle condensation conversion markedly produced nucleation mode particles at the tunnel entrance section. Observations also showed Aitken mode particles markedly formed by coagulation growth of nucleation mode particles in the tunnel middle section and exit section. That is, the particle size distributions changed significantly inside the tunnel. Measurement results suggest that particles in the Aitken mode in the long tunnel governed UFP levels.  相似文献   

14.
Personal measurements of exposure to particulate air pollution (PM10, PM2.5, PM1) were simultaneously made during walking and in-car journeys on two suburban routes in Northampton, UK, during the winter of 1999/2000. Comparisons were made between concentrations found in each transport mode by particle fraction, between different particle fractions by transport mode, and between transport microenvironments and a fixed-site monitor located within the study area. High levels of correlation were seen between walking and in-car concentrations for each of the particle fractions (PM10: r2=0.82; PM2.5: r2=0.98; PM1: r2=0.99). On an average, PM10 concentrations were 16% higher inside the car than for the walker, but there were no difference in average PM2.5 and PM1 concentrations between the two modes. High PM2.5:PM10 ratios (0.6–0.73) were found to be associated with elevated sulphate levels. The PM2.5:PM10 and PM1:PM2.5 ratios were shown to be similar between walking and in-car concentrations. Concentrations of PM10 were found to be more closely related between transport mode than either mode was with concentrations recorded at the fixed-site (roadside) monitor. The fixed-site monitor was shown to be a poor marker for PM10 concentrations recorded during walking and in-car on a route over 1 km away.  相似文献   

15.
Concentrations of ultrafine (<0.1 μm) particles (UFPs) and PM2.5 (<2.5 μm) were measured whilst commuting along a similar route by train, bus, ferry and automobile in Sydney, Australia. One trip on each transport mode was undertaken during both morning and evening peak hours throughout a working week, for a total of 40 trips. Analyses comprised one-way ANOVA to compare overall (i.e. all trips combined) geometric mean concentrations of both particle fractions measured across transport modes, and assessment of both the correlation between wind speed and individual trip means of UFPs and PM2.5, and the correlation between the two particle fractions. Overall geometric mean concentrations of UFPs and PM2.5 ranged from 2.8 (train) to 8.4 (bus) × 104 particles cm?3 and 22.6 (automobile) to 29.6 (bus) μg m?3, respectively, and a statistically significant difference (p < 0.001) between modes was found for both particle fractions. Individual trip geometric mean concentrations were between 9.7 × 103 (train) and 2.2 × 105 (bus) particles cm?3 and 9.5 (train) to 78.7 (train) μg m?3. Estimated commuter exposures were variable, and the highest return trip mean PM2.5 exposure occurred in the ferry mode, whilst the highest UFP exposure occurred during bus trips. The correlation between fractions was generally poor, and in keeping with the duality of particle mass and number emissions in vehicle-dominated urban areas. Wind speed was negatively correlated with, and a generally poor determinant of, UFP and PM2.5 concentrations, suggesting a more significant role for other factors in determining commuter exposure.  相似文献   

16.
A low-cost air sensor package was used to monitor indoor air quality (IAQ) in a classroom at the Albany Middle School in the San Francisco Bay Area of California. A rapid increase in carbon dioxide (CO2) was observed in the classroom as soon as it is occupied. When the classroom is unoccupied, the CO2 levels decay slowly toward the outdoor background level. All high CO2 concentrations observed inside the classroom, above the outdoor background, was due to exhaling of the occupants. The CO2 concentrations generally exceed the recommended level of 1000 ppb towards the end of the school day. The exceedances and slow decay may suggest that the ventilation rate in this school is not sufficient. The particulate level in the classroom was low until a distant wildfire advected large amount of particulate matter to the San Francisco Bay Area. Very high (10–15 times compared to the background) particle numbers (per m3 of particles with diameter >0.3 µm) were observed in the classroom during the wildfire. These particles were relatively small (0.3–1.0 µm) and the filters (MERV 8) of the ventilation system were unable to filter them out. Therefore, the measurements made by low-cost particle counters can inform the school administrators of adverse IAQ during future wildfire (or other combustion) events. The particle number was independent of the occupation before and during the wildfire suggesting that all observed particles were infiltrated into the classroom from outside. Consistent with previous studies, no appreciable increase in the local ambient CO2 background was observed during this distant wildfire event.

Implications: Low-cost air sensors are effective in monitoring indoor air quality in classrooms. The CO2 levels in classrooms are mainly generated indoors due to exhalation of occupants. Concentration of CO2 generally exceed the recommended level of 1000 ppb towards the end of the school day. In contrast, the particulate matter mostly comes from outdoors and small particles penetrate though the filters normally used at schools. Distant wildfires do not increase the local CO2 background appreciably, but significantly increase the particulate matter concentrations both indoors and outdoors. Further investigations are needed to assure that ventilation rates in classrooms are sufficiently health protective.  相似文献   

17.
In this study, we present how an indoor aerosol model can be used to characterize particle emitter and predict influence of the source on indoor air quality. Particle size-resolved emission rates were quantified and the source’s influence on indoor air quality was estimated by using office model simulations. We measured particle emissions from three modern laser printers in a flow-through chamber. Measured parameters were used as input parameters for an indoor aerosol model, which we then used to quantify the particle emission rates. The same indoor aerosol model was used to simulate the effect of the particle emission source inside an office model. The office model consists of a mechanically ventilated empty room and the particle source. The aerosol from the ventilation air was a filtered urban background aerosol. The effect of the ventilation rate was studied using three different ventilation ratios 1, 2 and 3 h?1. According to the model, peak emission rates of the printers exceeded 7.0 × 108 s?1 (2.5 × 1012 h?1), and emitted mainly ultrafine particles (diameter less than 100 nm). The office model simulation results indicate that a print job increases ultrafine particle concentration to a maximum of 2.6 × 105 cm?3. Printer-emitted particles increased 6-h averaged particle concentration over eleven times compared to the background particle concentration.  相似文献   

18.
A tunnel-type semi-enclosed atmosphere is characterized by a higher particulate pollution than urban zones and highlights the particulate species having an impact on material degradation. Therefore, a transverse approach between air composition and its consequences upon longevity of materials is necessary, requiring a better knowledge of tunnel atmosphere and a better understanding of material degradation inside a tunnel for operating administration. The characterization of particulate matter collected inside a road tunnel in Rouen (France) allows us to set up the features of the particle characteristics of the real conditions of field exposure. Two sampling campaigns include analyses of organic and water-soluble ionic fractions. The current work shows that organic species, grouped into two sets derived primarily from engine exhaust and debris with wear particles resuspended by the traffic, are divided into two groups: a majority comprising n-alkanes, alkanoic acids, phthalates, ketones, and benzothiazole and a minority one composed of BTEX (benzene, toluene, ethylbenzene, and xylenes), polycyclic aromatic hydrocarbons (PAHs), fatty acid methyl esters (FAMEs), furans, phenols, and alkenes. As regards the water-soluble ionic fraction, the ionic species such as Cl?, SO4 2?, CH3COO?, HCOO?, NO3 ?, NH4 +, and Na+ are involved in the degradation process. The inorganic particles (insoluble and slightly soluble), debris and wear particles, organic acids, and relative humidity play a key role and are important factors to consider in the degradation process.

Implications: Particles, together with relative humidity, can play an important role in the degradation of materials inside a road tunnel. Depth knowledge of the environment prevailing inside a tunnel improves the criteria for selection of materials of equipments contained therein. In the present study, it appears that the particulate mass can be divided into two groups with distinct effects: a water-soluble particle group is the source of ionic species involved in the degradation process, and a slightly water-soluble or insoluble particle group that acts as reservoir of condensed water when covering the surface of the material.  相似文献   

19.
The number of ultrafine particles may be a more health relevant characteristic of ambient particulate matter than the conventionally measured mass. Epidemiological time series studies typically use a central site to characterize human exposure to outdoor air pollution. There is currently very limited information how well measurements at a central site reflect temporal and spatial variation across an urban area for particle number concentrations (PNC).The main objective of the study was to assess the spatial variation of PNC compared to the mass concentration of particles with diameter less than 10 or 2.5 μm (PM10 and PM2.5).Continuous measurements of PM10, PM2.5, PNC and soot concentrations were conducted at a central site during October 2002–March 2004 in four cities spread over Europe (Amsterdam, Athens, Birmingham and Helsinki). The same measurements were conducted directly outside 152 homes spread over the metropolitan areas. Each home was monitored during 1 week. We assessed the temporal correlation and the variability of absolute concentrations.For all particle indices, including particle number, temporal correlation of 24-h average concentrations was high. The median correlation for PNC per city ranged between 0.67 and 0.76. For PM2.5 median correlation ranged between 0.79 and 0.98. The median correlation for hourly average PNC was lower (range 0.56–0.66). Absolute concentration levels varied substantially more within cities for PNC and coarse particles than for PM2.5. Measurements at the central site reflected the temporal variation of 24-h average concentrations for all particle indices at the selected homes across the urban area. A central site could not assess absolute concentrations across the urban areas for particle number.  相似文献   

20.
Vehicular emitted air pollutant concentrations were studied near three types of roadways in Austin, Texas: (1) State Highway 71 (SH-71), a heavily traveled arterial highway dominated by passenger vehicles; (2) Interstate 35 (I-35), a limited access highway north of Austin in Georgetown; and (3) Farm to Market Road 973 (FM-973), a heavily traveled surface roadway dominated by truck traffic. Air pollutants examined include carbon monoxide (CO), oxides of nitrogen (NOx), and carbonyl species in the gas-phase. In the particle phase, ultrafine particle (UFP) concentrations (diameter < 100 nm), fine particulate matter (PM2.5, diameter < 2.5 μm) mass and carbon content and several particle-bound organics were examined. All roadways had an upwind stationary sampling location, one or two fixed downwind sample locations and a mobile monitoring platform that characterized pollutant concentrations fall-off with increased distance from the roadways. Data reported in this paper focus on UFP while other pollutants and near-roadway chemical processes are examined in a companion paper. Traffic volume, especially heavy-duty traffic, wind speed, and proximity to the road were found to be the most important factors determining UFP concentrations near the roadways. Since wind directions were not consistent during the sampling periods, distances along wind trajectories from the roadway to the sampling points were used to study the decay characteristics of UFPs. Under perpendicular wind conditions, for all studied roadway types, particle number concentrations increased dramatically moving from the upwind side to the downwind side. The elevated particle number concentrations decay exponentially with increasing distances from the roadway with sharp concentration gradients observed within 100–150 m, similar to previously reported studies. A single exponential decay curve was found to fit the data collected from all three roadways very well under perpendicular wind conditions. No consistent pattern was observed for UFPs under parallel wind conditions. However, regardless of wind conditions, particle concentrations returned to background levels within a few hundred meters of the roadway. Within measured UFP size ranges, smaller particles (6–25 nm) decayed faster than larger ones (100–300 nm). Similar decay rates were observed among UFP number, surface, and volume.  相似文献   