首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study evaluates effects of good burning practice and correct installation and management of wood heaters on indoor air pollution in an Italian rural area. The same study attests the role of education in mitigating wood smoke pollution. In August 2007 and winters of 2007 and 2008, in a little mountain village of Liguria Apennines (Italy), indoor and outdoor benzene, toluene, ethylbenzene, and xylene (BTEX) concentrations were measured in nine wood-heated houses. During the first sampling, several mistakes in heating plant installations and management were found in all houses. Indoor BTEX concentrations increased during use of wood burning. Low toluene/benzene ratios were in agreement with wood smoke as main indoor and outdoor pollution source. Other BTEX sources were identified as the indoor use of solvents and paints and incense burning. Results obtained during 2007 were presented and discussed with homeowners. Following this preventive intervention, in the second winter sampling all indoor BTEX concentrations decreased, in spite of the colder outdoor air temperatures. Information provided to families has induced the adoption of effective good practices in stoves and fire management. These results highlight the importance of education, supported by reliable data on air pollution, as an effective method to reduce wood smoke exposures.
Implications:Information about burning practices and correct installation and management of wood heaters, supported by reliable data on indoor and outdoor pollution, may help to identify and remove indoor pollution sources. This can be an effective strategy in mitigate wood smoke pollution.  相似文献   

2.
Effects of soil properties on the accumulation of metals to wood mice (Apodemus sylvaticus) were evaluated at two sites with different pH and organic matter content of the soil. pH and organic matter content significantly affected accumulation of Cd, Cu, Pb and Zn in earthworms and vegetation. For Cd, Cu and Zn these effects propagated through the food web to the wood mouse. Soil-to-kidney ratios differed between sites: Cd: 0.15 versus 3.52, Cu: 0.37 versus 1.30 and Zn: 0.33-0.83. This was confirmed in model calculations for Cd and Zn. Results indicate that total soil concentrations may be unsuitable indicators for risks that metals pose to wildlife. Furthermore, environmental managers may, unintentionally, change soil properties while taking specific environmental measures. In this way they may affect risks of metals to wildlife, even without changes in total soil concentrations.  相似文献   

3.
Copper contamination is increasing in many aquatic ecosystems. One mode by which copper can be introduced into aquatic ecosystems is as an algaecide, such as Cutrine-Plus®. Using a mesocosm experiment, we examined the effects of Cutrine-Plus® on wood frog (Lithobates sylvaticus) tadpoles. In addition, we examined how the presence of a nonnative predator the Western mosquitofish (Gambusia affinis) may interact with exposure to Cutrine-Plus®. Exposure to our low and high Cutrine-Plus® treatments had a strong negative effect on the wood frog tadpoles, and survivorship was greatly decreased in the low treatment, and no tadpoles survived in the high treatment. Additionally, the tadpoles that survived the low treatment were significantly smaller than those in the control treatment. Mosquitofish had no effect on the survivorship or growth of wood frog tadpoles, and mosquitofish presence did not have a significant interaction with the Cutrine-Plus® treatments. Cutrine-Plus® clearly had a negative effect on wood frog tadpoles at the concentrations used in our experiment, which were at and below the label-recommended dosages, suggesting that the use of Cutrine-Plus® in natural ponds may have negative consequences for wood frog populations and possibly other amphibians.  相似文献   

4.
A study has been conducted in Launceston, Australia, to determine within households with wood heaters the effect of leakage from the heater and flue on the indoor air concentrations of the pollutants: benzene, toluene, ethylbenzene and xylene (BTEX). The study involved three classes: 28 households without wood heaters, 19 households with wood heaters compliant with the relevant Australian Standard and 30 households with non-compliant wood heaters. Outdoor and indoor BTEX concentrations were measured in each household for 7 days during summer when there was little or no wood heater usage, and for 7 days during winter when there was widespread wood heater usage. Each participant kept a household activity diary throughout their sampling periods. For wintertime, there were no significant differences of the indoor BTEX concentrations between the three classes of households. Also there were no significant relationships between BTEX indoor concentrations within houses and several measures of the amount of wood heater use within these houses. For the households sampled in this study, the use of a wood heater within a house did not lead to BTEX release within that house and had no direct detectable influence on the concentrations of BTEX within the house. We propose that the pressure differences associated with the both the leakiness or permeability of the building envelope and the draught of the wood heater have key roles in determining whether there will be backflow of smoke from the wood heater into the house. For a leaky house with a well maintained wood heater there should be no backflow of smoke from the wood heater into the house. However backflow of smoke may occur in well sealed houses.The study also found that wood heater emissions raise the outdoor concentrations of BTEX in winter in Launceston and through the mixing of outdoor air through the building envelopes into the houses, these emissions contribute to increases in the indoor concentrations of BTEX in winter in all houses in Launceston.  相似文献   

5.
Paniculate control strategies in the U.S. have historically focused on the reduction of industrial emissions. In recent years, however, area sources such as residential wood combustion have been recognized as significant and rapidly increasing sources of particulate emissions. In some areas of the country it will be necessary to substantially reduce residential wood burning emissions in order to attain or maintain acceptable levels of total and respirable particulate matter. A comprehensive strategy to reduce residential wood burning impacts has been developed for the Medford-Ashland area, 1 a community of about 100,000 population situated in a poorly ventilated valley in Oregon. Portions of this strategy will be applied in other areas of Oregon. The strategy may be applicable to urban communities in other states as well.  相似文献   

6.
Eberhardt TL  Lebow S  Reed KG 《Chemosphere》2012,86(8):797-801
A cellulose solvent system based on lithium chloride (LiCl) in N-methyl-2-pyrrolidinone (NMP) was used to assess the merits of partial dissolutions of coarsely ground wood samples. Alkaline Copper Quaternary (ACQ)-treated pine wood was of particular interest for treatment given the potential to generate a copper-rich stream apart from solid and/or liquid lignocellulosic feedstocks. Treatment with NMP alone gave yields of soluble materials that were higher than typical extractives contents thereby suggesting a limited degree of wood dissolution. Inclusion of LiCl, which disrupts hydrogen bonding, gave lower wood residue recoveries (i.e., higher dissolution) with higher LiCl concentration. Lower wood residue recoveries coincided with lower Klason lignin and hemicellulose-derived sugar contents in the wood residues. After treatment with 8% LiCl in NMP, subsequent filtration afforded 34% of the ACQ-treated sapwood as a wood residue retaining only 2% of the original copper. Pouring the filtrate over an excess of water resulted in the recovery of 30% of the solids and 50% of the copper together as a copper-enriched lignocellulosic precipitate. Results demonstrate a solvent system showing potential as a means to separate heavy metals from preservative-treated wood and to recover lignocellulosic feedstocks that may be suitable for use in a biorefinery.  相似文献   

7.
The rotation length is a key component of even-aged forest management systems. Using Fennoscandian forestry as a case, we review the socio-ecological implications of modifying rotation lengths relative to current practice by evaluating effects on a range of ecosystem services and on biodiversity conservation. The effects of shortening rotations on provisioning services are expected to be mostly negative to neutral (e.g. production of wood, bilberries, reindeer forage), while those of extending rotations would be more varied. Shortening rotations may help limit damage by some of today’s major damaging agents (e.g. root rot, cambium-feeding insects), but may also increase other damage types (e.g. regeneration pests) and impede climate mitigation. Supporting (water, soil nutrients) and cultural (aesthetics, cultural heritage) ecosystem services would generally be affected negatively by shortened rotations and positively by extended rotations, as would most biodiversity indicators. Several effect modifiers, such as changes to thinning regimes, could alter these patterns.  相似文献   

8.
Qian Y  Goodell B  Felix CC 《Chemosphere》2002,48(1):21-28
The purpose of this work was to improve our current knowledge of the non-enzymatic mechanisms involved in brown rot fungal decay of wood, but also to improve our understanding of chelator-mediated reactions that may occur in other biological systems where low pH conditions may prevail. Several key steps (iron chelation and reduction) during early non-enzymatic wood decay processes have been studied by using electron spin resonance (ESR). It has been proposed that low molecular weight chelators as well as Fenton reagents are involved in brown rot decay, at least in early non-enzymatic stages. In this work, the binding between a catecholate model chelator and ferric iron was studied by ESR spectroscopy. The effects of the model chelator, Fenton reagents, as well as the reaction conditions on free radical generation were also studied using ESR spin-trapping techniques. The results indicate: (1) The relative quantity of the chelator-iron complex can be determined by measurement of the intensities of the characteristic g = 4.3 ESR signal. (2) The effects of the chelator:iron ratio, the pH, and other reaction parameters on the hydroxyl radical generation in a Fenton type system can be determined using ESR spin-trapping techniques. (3) Data support the hypothesis that superoxide radicals are involved in chelator-mediated Fenton processes.  相似文献   

9.
Leaching of chromated copper arsenate wood preservatives: a review   总被引:13,自引:0,他引:13  
Recent studies have generated conflicting data regarding the bioaccumulation and toxicity of leachates from preservative-treated wood. Due to the scale of the wood preserving industry, timber treated with the most common preservative, chromated copper arsenate (CCA), may form a significant source of metals in the aquatic environment. The existing literature on leaching of CCA is reviewed, and the numerous factors affecting leaching rates, including pH, salinity, treatment and leaching test protocols are discussed. It is concluded from the literature that insufficient data exists regarding these effects to allow accurate quantification of leaching rates, and also highlights the need for standardised leaching protocols.  相似文献   

10.
Three mercury (Hg) species (gaseous elemental mercury (GEM), gaseous oxidized mercury (GOM), and fine particulate-bound mercury (PBM2.5)) were measured in the stack of a small scale wood combustion chamber at 400 °C, in the stack of an advanced wood boiler, and in two areas influenced by wood combustion. The low temperature process (lab-scale) emitted mostly GEM (∼99% when burning wood pellets and ∼95% when burning unprocessed wood). The high temperature wood boiler emitted a greater proportion of oxidized Hg (approximately 65%) than the low temperature system. In field measurements, mean PBM2.5 concentrations at the rural and urban sites in winter were statistically significantly higher than in warmer seasons and were well correlated with Delta-C concentrations, a wood combustion indictor measured by an aethalometer (UV-absorbable carbon minus black carbon). Overall the results suggest that wood combustion may be an important source of oxidized mercury (mostly in the particulate phase) in northern climates in winter.  相似文献   

11.
Most homes in the Navajo Nation use wood as their primary heating fuel, often in combination with locally mined coal. Previous studies observed health effects linked to this solid-fuel use in several Navajo communities. Emission factors (EFs) for common fuels used by the Navajo have not been reported using a relevant stove type. In this study, two softwoods (ponderosa pine and Utah juniper) and two high-volatile bituminous coals (Black Mesa and Fruitland) were tested with an in-use residential conventional wood stove (homestove) using a modified American Society for Testing and Materials/U.S. Environmental Protection Agency (ASTM/EPA) protocol. Filter sampling quantified PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 μm) and organic (OC) and elemental (EC) carbon in the emissions. Real-time monitoring quantified carbon monoxide (CO), carbon dioxide (CO2), and total suspended particles (TSP). EFs for these air pollutants were developed and normalized to both fuel mass and energy consumed. In general, coal had significantly higher mass EFs than wood for all pollutants studied. In particular, coal emitted, on average, 10 times more PM2.5 than wood on a mass basis, and 2.4 times more on an energy basis. The EFs developed here were based on fuel types, stove design, and operating protocols relevant to the Navajo Nation, but they could be useful to other Native Nations with similar practices, such as the nearby Hopi Nation.

Implications: Indoor wood and coal combustion is an important contributor to public health burdens in the Navajo Nation. Currently, there exist no emission factors representative of Navajo homestoves, fuels, and practices. This study developed emission factors for PM2.5, OC, EC, CO, and CO2 using a representative Navajo homestove. These emission factors may be utilized in regional-, national-, and global-scale health and environmental models. Additionally, the protocols developed and results presented here may inform on-going stove design of the first EPA-certified wood and coal combination stove.  相似文献   


12.
Dead wood provides a huge terrestrial carbon stock and a habitat to wide-ranging organisms during its decay. Our brief review highlights that, in order to understand environmental change impacts on these functions, we need to quantify the contributions of different interacting biotic and abiotic drivers to wood decomposition. LOGLIFE is a new long-term 'common-garden' experiment to disentangle the effects of species' wood traits and site-related environmental drivers on wood decomposition dynamics and its associated diversity of microbial and invertebrate communities. This experiment is firmly rooted in pioneering experiments under the directorship of Terry Callaghan at Abisko Research Station, Sweden. LOGLIFE features two contrasting forest sites in the Netherlands, each hosting a similar set of coarse logs and branches of 10 tree species. LOGLIFE welcomes other researchers to test further questions concerning coarse wood decay that will also help to optimise forest management in view of carbon sequestration and biodiversity conservation.  相似文献   

13.
Dead wood provides a huge terrestrial carbon stock and a habitat to wide-ranging organisms during its decay. Our brief review highlights that, in order to understand environmental change impacts on these functions, we need to quantify the contributions of different interacting biotic and abiotic drivers to wood decomposition. LOGLIFE is a new long-term ‘common-garden’ experiment to disentangle the effects of species’ wood traits and site-related environmental drivers on wood decomposition dynamics and its associated diversity of microbial and invertebrate communities. This experiment is firmly rooted in pioneering experiments under the directorship of Terry Callaghan at Abisko Research Station, Sweden. LOGLIFE features two contrasting forest sites in the Netherlands, each hosting a similar set of coarse logs and branches of 10 tree species. LOGLIFE welcomes other researchers to test further questions concerning coarse wood decay that will also help to optimise forest management in view of carbon sequestration and biodiversity conservation.  相似文献   

14.
Chlorinated ethenes (CE) are among the most frequent contaminants of soil and groundwater in the Czech Republic. Because conventional methods of subsurface contamination investigation are costly and technically complicated, attention is directed on alternative and innovative field sampling methods. One promising method is sampling of tree cores (plugs of woody tissue extracted from a host tree). Volatile organic compounds can enter into the trunks and other tissues of trees through their root systems. An analysis of the tree core can thus serve as an indicator of the subsurface contamination. Four areas of interest were chosen at the experimental site with CE groundwater contamination and observed fluctuations in groundwater concentrations. CE concentrations in groundwater and tree cores were observed for a 1-year period. The aim was to determine how the CE concentrations in obtained tree core samples correlate with the level of contamination of groundwater. Other factors which can affect the transfer of contaminants from groundwater to wood were also monitored and evaluated (e.g., tree species and age, level of groundwater table, river flow in the nearby Plou?nice River, seasonal effects, and the effect of the remediation technology operation). Factors that may affect the concentration of CE in wood were identified. The groundwater table level, tree species, and the intensity of transpiration appeared to be the main factors within the framework of the experiment. Obtained values documented that the results of tree core analyses can be used to indicate the presence of CE in the subsurface. The results may also be helpful to identify the best sampling period for tree coring and to learn about the time it takes until tree core concentrations react to changes in groundwater conditions. Interval sampling of tree cores revealed possible preservation of the contaminant in the wood of trees.  相似文献   

15.
PCDD/PCDF were determined in solid samples from wood combustion. The samples included grate ashes, bottom ashes, furnace ashes as well as fly and cyclone ashes. The solid waste samples were classified into bottom and fly ash from native wood and bottom and fly ash from waste wood. For each of the four classes concentration distribution patterns from individual congeners, the sums of PCDD/PCDF and the international toxicity equivalents (I-TEQ) values are given. The I-TEQ levels of fly ash from waste wood burning can be approximately up to two thousand times higher than the values from fly ashes of natural wood. The I-TEQ levels in bottom ashes from waste wood combustion systems are as low as the corresponding ashes from the combustion of native wood. Grate ash samples from waste wood combustion systems with low carbon burnout show high levels of PCDD/PCDF.  相似文献   

16.
Particle emissions from residential wood combustion in small communities in Northern Sweden can sometimes increase the ambient particle concentrations to levels comparable to densely trafficked streets in the center of large cities. The reason for this is the combination of increased need for domestic heating during periods of low temperatures, leading to higher emission rates, and stable meteorological conditions. In this work, the authors compare two different approaches to quantify the wood combustion contribution to fine particles in Northern Sweden: a multivariate source-receptor analysis on inorganic compounds followed by multiple linear regression (MLR) of fine particle concentrations and levoglucosan used as a tracer. From the receptor model, it can be seen that residential wood combustion corresponds with 70% of modeled particle mass. Smaller contributions are also seen from local nonexhaust traffic particles, road dust, and brake wear (each contributing 14%). Of the mass, 1.5% is explained by long-distance transported particles, and 2% derives from a regional source deriving from either oil combustion or smelter activities. In samples collected in ambient air, a significant linear correlation was found between wood burning particles and levoglucosan. The levoglucosan fraction in the ambient fine particulate matter attributed to wood burning according to the multivariate analysis ranged from < 2% to 50%. This is much higher than the fraction found in the emission from the boilers expected to be responsible for most emissions at this site (between 3% and 6%). A laboratory emission study of wood and pellet boilers gave 0.3% wt to 22% wt levoglucosan to particle mass, indicating that the levoglucosan fraction may be highly dependent on combustion conditions, making it uncertain to use it as a quantitative tracer under real-world burning conditions. Thus, quantitative estimates of wood burning contributions will be very uncertain using solely levoglucosan as a tracer.  相似文献   

17.
Since volatile mold metabolites are used for the detection of mold growth in buildings, it was interesting to determine whether different indoor mold species show different affinity for the major components of wood, a common building material. Growth and volatile metabolites were studied when Aspergillus versicolor, Penicillium chrysogenum, and P. palitans were grown on laboratory substrates containing the major wood constituents cellulose, xylan and lignin. Microbial volatile organic compounds (MVOCs) were characterized by thermal desorption/gas chromatography/mass spectroscopy. Growth and volatile metabolites varied considerably and there appeared to be complementary substrate specificities for P. chrysogenum, and P. palitans grown on cellulose and xylan. The failure of A. versicolor to produce characteristic MVOCs when grown on media containing wood constituents suggests that systems using volatile metabolites to detect microbial growth in buildings may be fundamentally unreliable for the detection of this species.  相似文献   

18.
Mercury removal from incineration flue gas by organic and inorganic adsorbents   总被引:11,自引:0,他引:11  
Jurng J  Lee TG  Lee GW  Lee SJ  Kim BH  Seier J 《Chemosphere》2002,47(9):907-913
Experiments were performed to investigate various adsorbents for their mercury removal capabilities from incineration flue gases. Four different materials were tested; Zeolite, Bentonite, activated carbon (AC), and wood char. Real incineration off-gas and in-lab simulated combustion flue gases (N2 + Hg) were used. Three cylindrical-shaped sorbent columns with 5 cm in diameter and 20 cm in length were used. The gas flow rate was fixed at 660 l/h at all times. Concentrations of NO, CO, O2, CO2, SO2, H2O, HCl, and mercury were continuously monitored. Mercury removal efficiencies of natural Zeolite and Bentonite were found to be much lower than those of the referenced AC. Amount of Hg removed were 9.2 and 7.4 microg/g of Zeolite and Bentonite, respectively. Removal efficiencies of each layer consisted of inorganic adsorbents were no higher than 7%. No significant improvement was observed with sulfur impregnation onto the inorganic adsorbents. Organic adsorbents (wood char and AC) showed much higher mercury removal efficiencies than those of inorganic ones (Zeolite and Bentonite). Mercury removal efficiency of wood char reached over 95% in the first layer, showing almost same effectiveness as AC which currently may be the most effective adsorbents for mercury. Amount of mercury captured by wood char was approximately 0.6 mg/g of wood char, close to the amount captured by AC tested in this study. Hence, wood char, made from the waste woods through a gasification process, should be considered as a possible alternative to relatively expensive AC.  相似文献   

19.
季铵化木屑纤维素的制备及其对水中苯酚的吸附性能研究   总被引:3,自引:2,他引:1  
以3-氯-2-羟丙基三甲基氯化铵(CTA)为醚化剂,对木屑纤维素进行了改性。探讨了改性木屑纤维素用量、pH值、吸附温度、吸附时间和苯酚初始浓度等因素对静态吸附效果的影响。结果表明,木屑纤维素经改性后,对水中的苯酚的吸附过程存在化学吸附,对水中的苯酚的吸附容量得到明显提高。  相似文献   

20.
Field trials were conducted at two sites in the Thames estuary to monitor losses of copper, chromium and arsenic from wood preservative treated timbers of varying sizes and treatment regimes. Results indicated that leaching tests conducted under standard laboratory conditions might overestimate losses compared to losses resulting from real environmental exposures. Amine copper treated wood was noted to leach higher levels of copper compared to chromated copper arsenate treated wood, and was therefore considered an inappropriate replacement biocide for fresh and marine construction purposes on this basis. Increases in copper concentrations in the outer sections of amine copper treated posts may have represented re-distribution of this component in this timber. No accumulation of metals was found in sediments surrounding field trial posts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号