1.
Chen HL  Su HJ  Hsu JF  Liao PC  Lee CC 《Chemosphere》2008,70(4):673-681
This study determined the levels of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), and dioxin-like polychlorinated biphenyls (dl-PCBs) in 240 individual food samples, belonging to 37 different foodstuffs in first total diet study (TDS) in Taiwan. The foods were collected from markets located in eight cities or counties around Taiwan. The food was cooked in a laboratory according to recipes typically used in Taiwan. In this study, PCDD/Fs were lower than the limits proposed by the European Union (EU) regulation for commercialized food, except for a notable PCDD/Fs level in ducks (3.660 pg WHO-TEQ/g, fat) obtained from central Taiwan. We hypothesize the duck meat might be probably polluted via emission of a fly ash recycling plant located near the duck farms. In addition to fish, most foods had high PCDD/Fs to dl-PCBs ratio. Needle fish and sea perch had relatively lower PCDD/Fs and dl-PCBs levels compared with those in other fish. Data from this study can be utilized for further consideration about dietary intake.  相似文献   

2.
Control of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in emissions and thermal residues from incinerators has been a cause of public concern for more than one decade. Recently, several studies showed that other persistent organic pollutants (POPs) such as coplanar polychlorinated biphenyls (co-PCBs) also have dioxin-like activity and are released from incinerators. Therefore, the present study was aimed at making a risk assessment about dioxin-like activity in extracts of thermal waste residues (e.g. combustion gas; fly ash, slag) from incineration and melting processes in Germany and Japan. For this purpose, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), coplanar polychlorinated biphenyls (co-PCBs), polychlorinated naphthalenes (PCNs) and polyaromatic hydrocarbons (PAHs) were analyzed by chemical analysis. Additionally, 2, 3, 7, 8-TCDD equivalents (EROD-TEQs) were determined by in vitro Micro-EROD bioassay using rat H4IIE hepatoma cells. EROD-TEQs could be correlated to I-TEQ values (from PCDD/Fs/co-PCBs) analyzed by chemical analysis resulting in a maximal sixfold higher estimate. Our study indicates minor influences of co-PCBs, PAHs and PCNs to the sum of dioxin-like toxicity in the extracts of thermal waste residues as determined here. Furthermore, we showed that the levels of dioxins and co-PCBs contained in slag from melting processes and bottom ashes from incineration processes were lower by 1-2 orders of magnitude than that in fly ash.  相似文献   

3.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

4.
In 2005, the partial substitution (20%) of fossil fuel by sewage sludge was tested in a Spanish cement plant. In order to establish the environmental impact for the surroundings, in 2006, the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and heavy metals (As, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sn, Tl, V, and Zn) were monitored in soil and vegetation samples collected near the cement plant. The temporal trends in the pollutant levels were studied by comparing the concentrations with those obtained in a previous survey (2003) in the same sampling sites. Very slight changes of the PCDD/F concentrations in both monitors were registered in the period 2003–2006 (0.17–0.15 and 0.94–1.10 ng I-TEQ kg−1 dw in herbage and soil, respectively). In turn, there was a notable heterogeneity in the evolution of metal levels, which varied according to each particular element. Anyhow, the current levels of organic and inorganic pollutants are in the low part of the range in comparison with other zones impacted by cement plants, as well as industrial and urban areas worldwide. The human health risks derived from the exposure to PCDD/Fs and metals were also assessed. Although the cancer risks due to PCDD/Fs slightly increased, a reduction of the total carcinogenic risks, including metals, was noted. In conclusion, there were not observed impact changes for the environmental and the local population as a consequence of using sewage sludge as secondary fuel.  相似文献   

5.
The contaminated air with burning plastic floor and electronic scrap was monitored with semipermeable membrane devices (SPMDs) and fresh unpolluted spruce needles at the same time for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs). It was found that there were more polychlorinated dibenzofurans (PCDFs) than polychlorinated dibenzo-p-dioxins (PCDDs) collected from contaminated air. The total amounts of PCBs were much higher than that of PCDD/Fs, but the contribution of them to the WHO-TEQ was less than that of PCDD/Fs. Triolein-containing SPMDs can absorb much more PCDD/Fs and PCBs than spruce needles when they were exposed in contaminated air simultaneously. The logarithm of the concentrations of PCDD/Fs and PCBs in SPMDs and in spruce needles at the same sampling time exhibited a significant linear correlation, the correlation coefficients were larger than 0.86 for PCDD/Fs and 0.92 for PCBs. SPMDs and spruce needles are effective passive air sampler for PCDD/Fs and PCBs. SPMDs and spruce needles can complement each other in passive air sampling.  相似文献   

6.
Bottom ash that was the result of the combustion of chromated copper arsenate (CCA) treated wood under controlled fire conditions showed an increase of several orders of magnitude in the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), compared to that of untreated timber. Wood that has been pressure treated with CCA contains copper (II), which is known to catalyse the so-called de novo formation of PCDD/Fs. Comparable levels of PCDD/Fs would be expected in residual ash from burning CCA-treated wood in backyard fires, stoves and wood heaters, as a consequence of similar combustion conditions.  相似文献   

7.
Background, aim, and scope  To enforce the implementation of the Kyoto Protocol targets, a number of governmental/international institutions have launched emission trade schemes as an approach to specify CO2 caps and to regulate the emission trade in recent years. These schemes have been basically applied for large industrial sectors, including energy producers and energy-intensive users. Among them, cement plants are included among the big greenhouse gas (GHG) emitters. The use of waste as secondary fuel in clinker kilns is currently an intensive practice worldwide. However, people living in the vicinity of cement plants, where alternative fuels are being used, are frequently concerned about the potential increase in health risks. In the present study, a cost–benefit analysis was applied after substituting classical fuel for sewage sludge as an alternative fuel in a clinker kiln in Catalonia, Spain. Materials and methods  The economical benefits resulting in the reduction of CO2 emissions were compared with the changes in human health risks due to exposure to polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and carcinogenic metals (As, Cd, Co, and Cr) before and after using sewage sludge to generate 20% of the thermal energy needed for pyro-processing. The exposure to PCDD/Fs and metals through air inhalation, soil ingestion and dermal absorption was calculated according to the environmental levels in soil. The carcinogenic risks were assessed, and the associated cost for the population was estimated by considering the DG Environment’s recommended value for preventing a statistical fatality (VPF). In turn, the amount of CO2 emitted was calculated, and the economical saving, according to the market prices, was evaluated. Results  The use of sewage sludge as a substitute of conventional energy meant a probability cancer decrease of 4.60 for metals and a cancer risk increase of 0.04 for PCDD/Fs. Overall, a net reduction of 4.56 cancers for one million people can be estimated. The associated economical evaluation due to the decreasing cancer for 60,000 people, the current population living near the cement plant, would be of 0.56 million euros (US$ 0.83 million). In turn, a reduction of 144,000 tons of CO2 emitted between 2003 and 2006 was estimated. Considering a cost of 20 euros per ton of CO2, the global saving would be 2.88 million euros (US$ 4.26 million). Discussion  After the partial substitution of the fuel, the current environmental exposure to metals and PCDD/Fs would even mean a potential decrease of health risks for the individuals living in the vicinity of the cement plant. The total benefit of using sewage sludge as an alternative fuel was calculated in 3.44 million euros (US$ 5.09 million). Environmental economics is becoming an interesting research field to convert environmental benefits (i.e., reduction of health risks, emission of pollutants, etc.) into economical value. Conclusions  The results show, that while the use of sewage sludge as secondary fuel is beneficial for the reduction in GHG emissions, no additional health risks for the population derived from PCDD/F and metal emissions are estimated. Recommendations and perspectives  Cost–benefit analysis seems to be a suitable tool to estimate the environmental damage and benefit associated to industrial processes. Therefore, this should become a generalized practice, mainly for those more impacting sectors such as power industries. On the other hand, the extension of the study could vastly be enlarged by taking into account other potentially emitted GHGs, such as CH4 and N2O, as well as other carcinogenic and non-carcinogenic micropollutants.  相似文献   

8.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

9.
The evolution of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in sewage sludge-amended soils used in the restoration of degraded lands, like quarries, has been studied. Two experiments were performed: one in the lab, under controlled conditions, and another in a quarry. Two different doses of sewage sludge were applied in both experiments (with two types of application in the quarry experiment) and the evolution of the amended soils were compared with that of the respective control soils (without addition of sewage sludge). The samples were analyzed with a previously validated method by HRGC HRMS after the extraction and the necessary clean-up steps. The results reveal that polluted sewage sludge increases PCDD/F concentration in soils and that these compounds are persistent in the matrix after long periods of time.  相似文献   

10.
Kim KS  Hong KH  Ko YH  Yoon KD  Kim MG 《Chemosphere》2003,53(6):601-607
Emission characteristics of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in diesel engine were studied with variable load rate of the diesel engine with the emission test cycles, US D-13 mode. The load rate is changed from 25% to 50% and 75% at constant speed of 2400 rpm. PCDD/Fs concentration and phase distribution of PCDD/Fs with the isokinetic sampling of exhaust gas is obtained in this study. The average PCDD/Fs concentrations per unit of exhaust gas with 25%, 50% and 75% load rate are 14.5, 6.9 and 6.4 pg-TEQ/N m3, respectively. In all diesel engine runs, PCDFs are more prevalent than PCDDs. As a load rate is increased, the ratio of PCDDs is gradually decreased. The amount of high-chlorinated PCDDs emitted in diesel engine is larger than that of low-chlorinated PCDDs. The significant emission form of PCDD/Fs produced from diesel engines exhaust is a gas phase.  相似文献   

11.
Particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were monitored at two sites in northern Greece for an eight-month period in 1999. PCDD/F concentrations were close to the lower end of reported values worldwide. Excepting a few cases, the PCDD/Fs homologue profile was stable. The gaseous PCDD/F fractions calculated were found to account for a small percentage of the total concentrations (<2% for OCDD/Fs and HpCDD/Fs, while 30-35% for TCDFs). Particle-bound PCBs were also found at low concentrations which, however, were higher at the urban site. Calculations of the dry deposition of particulate PCDD/ Fs and PCBs gave mean values of 0.52 and 0.59 pg I-TEQ/m2/day of PCDD/Fs, while 242 and 74 pg/m2/day of sigmaPCBs for the urban and the semirural areas respectively. An anticorrelation of PCDD/F concentrations with ambient temperature was derived particularly for the lower chlorinated congeners. A weak association with winds of western and southern origin was also observed. Factor analysis and literature source profiles were employed to identify possible emission sources. It was appeared that the PCDD/F compositional pattern of TSP is influenced by mixed sources the most prominent being uncontrolled fires and car exhausts.  相似文献   

12.
The uncontrolled burning of household waste in barrels has recently been implicated as a major source of airborne emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). A detailed, systematic study to understand the variables affecting emissions of PCDD/Fs from burn barrels was performed. The waste composition, fullness of the barrel, and the combustion conditions within the barrel all contribute significantly to determining the emissions of PCDD/Fs from burn barrels. The study found no statistically significant effect on emissions from the Cl content of waste except at high levels, which are not representative of typical household waste. At these elevated Cl concentrations, the impact of Cl on PCDD/F emissions was found to be independent of the form of the Cl (inorganic or organic). For typical burn conditions, most of the PCDD/F emissions appear to be associated with the later stages of the burn when the waste is smoldering. Polychlorinated biphenyls (PCBs) were also measured for a subset of the tests. For the nominal waste composition, the average emissions were 76.8 ng toxic equivalency units (TEQ)WHO98/kg of waste combusted, which suggests that uncontrolled burning of household waste could be a major source of airborne PCDD/Fs in the United States.  相似文献   

13.
Jin GZ  Lee SJ  Kang JH  Chang YS  Chang YY 《Chemosphere》2008,70(9):1568-1576
Polyethylene (PE) and polyvinyl chloride (PVC) are the leading plastics in total production in the world. The incineration of plastic-based materials forms many chlorinated compounds, such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). In this study the addition of goethite (alpha-FeOOH) was investigated to determine its suppressing effect on the emission of PCDD/Fs and hexachlorobenzene (HCB) during the combustion of wastes containing PE and PVC. Goethite was being considered since it acts as a dioxin-suppressing catalyst during incineration. Results showed that incorporation of goethite greatly reduced the generation of PCDD/Fs and HCB in the exhaust gas and fly ash. The concentration of PCDD/Fs in flue gas decreased by 45% for lab-scale and 52% for small incinerator combustion experiments, where the goethite ratios in feed samples were 0.54% and 0.34%, respectively. Under the same conditions, the concentration of HCB in flue gas decreased by 88% and 62%, respectively. The present study showed a possible mechanism of the suppressing effect of the goethite for PCDD/F formation. It is likely that iron chlorides react with particulate carbon to form organo-chlorine compounds and promote PCDD/F formation in the gas phase. XRD analysis of combustion ash revealed that the goethite was partially dehydrated and converted to alpha-Fe(2)O(3) and Fe(3)O(4) but no iron chlorides formation. Therefore the goethite impregnated plastics can contribute the reduction of PCDD/Fs and HCB in the exhaust gas during incineration of MSW.  相似文献   

14.
The distribution of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), in brief dioxins, has seldom been addressed systematically in fly ash from municipal solid waste incinerators (MSWIs). This study shows the amount and fingerprint of PCDD/Fs in fly ash from four different Chinese MSWIs, that is, three mechanical grate units and one circulating fluidized bed unit. In these fly ash samples, dioxins-related parameters (international toxic equivalent quantity, total amount of PCDD/Fs, individual isomer classes, and 17 toxic 2,3,7,8-substituted congeners) all tend to increase with decreasing particle size for mechanical grate incinerators, yet only for the finest fraction for fluidized bed units. Moreover, the fluidized bed incinerator seems superior to grate incineration in controlling dioxins, yet a comparison is hampered by internal differences in the sample, for example, the fluidized bed fly ash has much lower carbon and chlorine contents. In addition, the presence of sulfur from mixing coal as supplemental fuel to the MSW may poison the catalytic steps in dioxins formation and thus suppress the formation of dioxins. With more residual carbon and chlorine in the fly ash, it is easier to form dioxins during cooling. Nevertheless, there is no apparent relation between Fe, Cu, and Zn contents and that of dioxins in fly ash.

Implications This paper is of interest because it presents the amounts and distribution of PCDD/Fs in fly ash samples from some typical waste incineration plants in China, featuring distinct incinerator types, combustion conditions, fuel composition, or residual carbon, chloride, and heavy metal contents in fly ash.  相似文献   

15.
The distribution of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), in brief dioxins, has seldom been addressed systematically in fly ash from municipal solid waste incinerators (MSWIs). This study shows the amount and fingerprint of PCDD/Fs in fly ash from four different Chinese MSWIs, that is, three mechanical grate units and one circulating fluidized bed unit. In these fly ash samples, dioxins-related parameters (international toxic equivalent quantity, total amount of PCDD/Fs, individual isomer classes, and 17 toxic 2,3,7,8-substituted congeners) all tend to increase with decreasing particle size for mechanical grate incinerators, yet only for the finest fraction for fluidized bed units. Moreover, the fluidized bed incinerator seems superior to grate incineration in controlling dioxins, yet a comparison is hampered by internal differences in the sample, for example, the fluidized bed fly ash has much lower carbon and chlorine contents. In addition, the presence of sulfur from mixing coal as supplemental fuel to the MSW may poison the catalytic steps in dioxins formation and thus suppress the formation of dioxins. With more residual carbon and chlorine in the fly ash, it is easier to form dioxins during cooling. Nevertheless, there is no apparent relation between Fe, Cu, and Zn contents and that of dioxins in fly ash.  相似文献   

16.
Unintentionally produced persistent organic pollutants (UP-POPs) including polychlorinated dibenzo-p-dioxins, and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polychlorinated naphthalenes (PCNs) were characterized and quantified in stack gas and fly ash from the second ventilation systems in five typical converters in five different steelmaking plants. The 2378-substituted PCDD/Fs (2378-PCDD/Fs) and dioxin-like PCB (dl-PCBs) toxic equivalents (TEQs) were 1.84–10.3 pg WHO-TEQ Nm?3 in the stack gas and 5.59–87.6 pg WHO-TEQ g?1 in the fly ash, and the PCN TEQs were 0.06–0.56 pg TEQ Nm?3 in the stack gas and 0.03–0.08 pg TEQ g?1 in the fly ash. The concentrations of UP-POPs in the present study were generally lower than those in other metallurgical processes, such as electric arc furnaces, iron ore sintering, and secondary metallurgical processes. Adding scrap metal might increase UP-POP emissions, indicating that raw material composition was a key influence on emissions. HxCDF, HpCDF, OCDF, HpCDD, and OCDD were the dominant PCDD/Fs in the stack gas and fly ash. TeCB and PeCB were dominant in the stack gas, but HxCB provided more to the total PCB concentrations in the fly ash. The lower chlorinated PCNs were dominant in all of the samples. The 2378-PCDD/F, dl-PCB, and PCN emission factors in stack gases from the steelmaking converter processes (per ton of steel produced) were 1.88–2.89, 0.14–0.76, and 229–759 μg t?1, respectively.  相似文献   

17.
Li X  Ke Z  Dong J 《Chemosphere》2011,82(5):635-638
The levels of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) were analyzed by an isotope-dilution high-resolution mass spectrometric in 16 sewage sludges, sampled from 2004 to 2009, from two municipal wastewater treatment plants (WWTPs) in Beijing. Total toxicity equivalent (TEQ) values were evaluated using the toxicity equivalent factors proposed by International for PCDD/Fs. The I-TEQs for these sewage sludges were from 0.97 to 15.0 pg g−1 dry weight (dw) with a mean value 4.43 pg g−1 dw, indicating that all I-TEQs were below Chinese legislation limit value regulated for agricultural use in soils.The results from limited samples (16 samples) showed that the levels of PCDD/Fs might be correlated with the sludge age. Meanwhile, the temporal trends of PCD/Fs suggested that the I-TEQs may correlate with rainfall in the present study.  相似文献   

18.
A survey to estimate the polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) emissions of Spanish hot dip galvanising sector was carried out during 2002. This investigation is the first presenting Spanish experimental data related to this industrial sector. Three different matrices: flue gas, ash and filter dust were tested to quantify the PCDD/Fs generated during the galvanising process. The organic source of PCDD/F formation could be from the insufficient degreasing o from inhibitors or additives used in the pickling steps such as quinoline, isoquinoline, 8-methylquinoline or polyether phosphoric acid. Low levels PCDD/Fs were achieved in air emissions when air control devices are used. On the contrary, filter dusts are highly contaminated; indicating that the absence of air control devices would increase the risk of fugitive emissions. Homologue profiles and Principal Component Analysis demonstrate there are differences in the formation mechanisms in the bath zone (ashes) compared to the stack location (filter dusts and air emissions), related to the de novo synthesis and reaction time. The annual PCDD/F emission to the atmosphere for this sector during 2002 has been estimated in 0.023g I-TEQ. The emission factor of plants with air control devices has been calculated at 0.030microg I-TEQ/ton of galvanised steel.  相似文献   

19.
The factors affecting polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) formation were studied in sewage sludge incineration tests carried out on a demonstrative plant. The plant includes a circulating fluidised bed furnace (FBF) and a rotary kiln furnace (RKF), operating alternatively. During the tests sewage sludge was spiked with chlorinated hydrocarbons and the operating parameters of the afterburning chamber were varied. PCDD/F were sampled in each test before the bag filter, thus collecting the above contaminants before abatement systems. From the tests it appeared that PCDD/F were always produced in more abundance in the tests carried out by FBF than by RKF. The higher PCDD/F concentrations in the tests by FBF were reached when sewage sludge was spiked with a high dosage of a surrogate organic mixture of chlorinated hydrocarbons and when the afterburning chamber was used only as transit equipment with the burner off. The distribution of the different PCDD/F homologues was compared. P5CDFs were generally the prevalent fraction, with very few exceptions for the tests by RKF at high temperature of the afterburning chamber. As for FBF tests, it was found that the PCDD/F homologue profile depends on the afterburning chamber temperature.  相似文献   

20.
Pan J  Yang YL  Chen DZ  Xu Q  Tang H  Li Y  Nie LM  Jiang K  Xi DL 《Chemosphere》2008,70(9):1699-1706
Seven of surface sediments, one sediment core and two mussel samples were collected from the Qingdao coastal sea of the western Yellow Sea and analyzed to determine the horizontal distribution, deposition flux, and toxicity equivalency (TEQs) of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The total PCDD/Fs concentrations in the surface sediments ranged between 10.7 and 428 ng kg(-1) dry wt. The horizontal distribution of PCDD/F congeners in the sediments was characterized by elevated concentrations at the locations in the east of Jiaozhou Bay with the highest concentration occurring near the Haibo River mouth. Physical parameters (total organic carbon contents and sediment types) and the current circulation systems in Jiaozhou Bay can be important factors controlling the horizontal distribution pattern of PCDD/Fs in the bay. The influence of the Haibo River as a source of pollution was evidenced by PCDD/F homologue profiles, indicating a contribution from sewage sludge in addition to other possible sources. Records from the sediment core revealed that the total PCDD/Fs in the Qingdao coastal sea were nearly constant since 1951 till 1980s and increased remarkably after 1980s. The total 2,3,7,8-substituted PCDD/Fs and total TEQs of PCDD/Fs on the lipid basis in the mussel sample inside the bay were significantly higher than in the adjacent sediment. The homologue profiles of PCDD/Fs in the mussels were quite different from those of the sediments, characterized by high TCDF (50% of the total PCDD/Fs).  相似文献   