首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Laboratory experiments demonstrate that in situ recovery of pooled tetrachloroethene (PCE) from porous media may be accomplished more efficiently using multiple-step alcohol floods than with single alcohol floods. To optimize flooding efficiency while maintaining a low risk of downward DNAPL mobilization, a three-step flooding process is developed employing an isobutanol preflood, a composite alcohol mainflood, and a polymer solution postflood. The density and viscosity of these solutions are manipulated to prevent the onset and propagation of viscous and gravitational fingers, while maintaining phase behavior critical for efficient miscible NAPL displacement. An aqueous partitioning preflood solution of 10% by volume (10% v) isobutanol reduces the NAPL density in situ to approximately 1.00 g/ml by swelling the NAPL prior to miscible displacement induced by the mainflood. The composite alcohol mainflood, containing 65% v ethylene glycol and 35% v 1-propanol maintains miscibility while achieving neutral buoyancy and near stable displacement of the NAPL. Aqueous solutions of xanthan gum polymer efficiently displace the mainflood, reducing viscous fingering associated with waterfloods. Two-dimensional experiments using the multiple-step technique achieve 99.8% DNAPL mass recovery using a total of 0.45 pore volumes of alcohol, illustrating greater recovery efficiency than previous alcohol flooding formulations under comparable conditions.  相似文献   

2.
Packed column experiments were conducted to study effects of initial saturation of tetrachloroethene (PCE) in the range of 1.0-14% pore volume (PV) on mobilization and downward migration of the non-aqueous phase liquid (NAPL) product upon contact with aqueous isobutanol ( approximately 10 vol.%). This study focused on the consequences of swelling beyond residual saturation. Columns were packed with mixtures of neat PCE, water and glass beads and waterflooded to establish a desired homogeneous residual saturation, and then flooded with aqueous isobutanol under controlled hydraulic conditions. Results showed a critical saturation of approximately 8% PV for these packed column experimental conditions. At low initial PCE saturations (<8% PV), experimental results showed reduced risk of NAPL-product migration upon contact with aqueous isobutanol. At higher initial PCE saturations (>8% PV), results showed NAPL-product mobilization and downward migration which was attributed to interfacial tension (IFT) reduction, swelling of the NAPL-product, and reduced density modification. Packed column results were compared with good agreement to theoretical predictions of NAPL-product mobilization using the total trapping number, N(T). In addition to the packed column study, preliminary batch experiments were conducted to study the effects of PCE volumetric fraction in the range of 0.5-20% on density, viscosity, and IFT modification as a function of time following contact with aqueous isobutanol ( approximately 10 vol.%). Modified NAPL-product fluid properties approached equilibrium within approximately 2 h of contact for density and viscosity. IFT reduction occurred immediately as expected. Measured fluid properties were compared with good agreement to theoretical equilibrium predictions based on UNIQUAC. Overall, this study demonstrates the importance of initial DNAPL saturation, and the associated risk of downward NAPL-product migration, in applying alcohol flooding for remediation of DNAPL contaminated ground water sites.  相似文献   

3.
A common aspect of innovative remediation techniques is that they tend to reduce the interfacial tension between the aqueous and non-aqueous phase liquids, resulting in mobilization of the organic contaminant. This complicates the remediation of aquifers, contaminated with Dense Non-Aqueous Phase Liquids (DNAPLs), as they are likely to migrate downwards, deeper into the aquifer and into finer layers. A possible solution is the use of swelling alcohols, which tend to reduce the density difference between the aqueous phase and the DNAPL. To avoid premature mobilization upon the initial contact between the DNAPL and the alcohol, several researchers have proposed the use of vertical upward flow of the alcohol. In this paper, we present an equation, which describes the upward mobilization of both continuous and discontinuous DNAPLs and so the important parameters governing the upward controlled mobilization of the DNAPL. The need and required magnitude of this specific discharge was investigated by conducting four column experiments in which the initial density of the DNAPL and the permeability was varied. It was shown that the required flow velocities increase with the permeability of the porous medium and the initial density difference between the aqueous phase and the DNAPL. Whenever the specific discharge falls below the critical value, the DNAPL moves downward. A second set of column experiments looked at the impact of permeability of porous medium on the solubilization and mobilization of DNAPL during alcohol flooding. Columns, packed with coarse or fine sand, containing a residual trichloroethylene (TCE) or perchloroethylene (PCE) saturation were flushed with the alcohol mixture at a fixed specific discharge rate. The induced pressure gradients in the aqueous phase, which were higher in the fine sand, resulted for this porous medium in extensive mobilization of the DNAPL against the direction of the buoyancy force. The density of the first NAPL coming out of the top of the fine sand was close to that of the pure DNAPL. In the coarser sand, the pressure gradients were sufficient to prevent downward migration of the DNAPL, but upward mobilization was minimal. The predominant removal mechanism in this case was the much slower solubilization.  相似文献   

4.
In this work, we extend the recently developed gradient approach for surfactant-enhanced remediation of dense non-aqueous phase liquid (DNAPL)-impacted sites. The goal of the gradient approach is to maximize the DNAPL solubilization capacity in swollen micelles (Type I aqueous microemulsions) while at the same time minimizing the potential for DNAPL mobilization. In this work, we introduce a modified version of the capillary/trapping curve that we refer to as the gradient curve to help interpret and/or design the gradient approach. The gradient curve presents the residual DNAPL saturation as a function of interfacial tension and microemulsion viscosity. This approach demonstrates that keeping a low viscosity of the microemulsion phase is not only important for keeping a low head loss during surfactant flooding but also to prevent oil mobilization. Eight microemulsion systems were evaluated in this research; these systems were evaluated based on their tetrachloroethylene (PCE) solubilization capacity, interfacial tension (IFT), viscosity, density, and coalescence kinetics. Two of these systems were chosen for evaluation in site-specific column tests using an increasing electrolyte gradient to produce a decreasing IFT/increasing solubilization gradient system. The column studies were conducted with media from Dover Air Force Base in Dover, DE. Both solubilized and mobilized DNAPL were quantified. During the column studies, we observed that substantial PCE was mobilized when the residual level of PCE in the column was significantly higher than the steady-state residual saturation level being approach (as predicted from the gradient curve). Four column studies were performed, three of which were used to asses the validity of the gradient curve in predicting the residual saturation after each gradient step. From these tests we observed that starting IFTs of less than 1 mN/m all produced the same mobilization potential. In the last column, we used an additional gradient step with an initial IFT above 1 mN/m to dramatically reduce the amount of PCE mobilize. Based on the good agreement between column results and projections based on the gradient curve, we propose this as a preferred method for designing gradient surfactant flushing systems.  相似文献   

5.
The mass transfer rate from residual dense non-aqueous phase liquids (DNAPLs) to the mobile aqueous phase is an important parameter for the efficiency of surfactant-enhanced remediation through solubilization of this type of contamination. The mass transfer kinetics are highly dependent on the dimensionality of the system. In this study, irregularly shaped residual TCE saturations in two-dimensional saturated flow fields were flushed with a 2% polyoxyethylene sorbitan (20) monooleate (POESMO) solution until complete removal had been achieved. A numerical model was developed and used for the simulation of the various surfactant-flushing experiments with different initial saturation patterns and flow rates. Through optimization against in situ concentration and saturation data, a phenomenological power-law model for the relationship between the mass transfer rate from the DNAPL to the mobile aqueous phase on the one hand and the residual DNAPL saturation and the flow velocity on the other hand was derived. The obtained mass transfer rate parameters provide a reasonable fit to the experimental data, predicting the cleanup time and the general saturation and concentration pattern quite well but failing to predict the concentration curves at every individual sampling port. The obtained mass transfer rate model gives smaller values for the predicted mass transfer rate but shows a comparable dependence on water flow and saturation as in earlier published one-dimensional column experiments with identical characteristics for porous medium, DNAPL and surfactant. Mass transfer rate predictions were about one order of magnitude lower in the 2-D flow cell experiment than in 1-D column experiments. These results give an indication for the importance of dimensionality during surfactant remediation.  相似文献   

6.
A particular problem with the release of dense nonaqueous phase liquids (DNAPLs) into the environment is identifying where the DNAPL is and if it is still moving. This question is particularly important at sites where thousands of cubic meters of DNAPLs were disposed of. To date, results from laboratory models have not been scaled to predict analogous migration at the larger length and time scales appropriate for sites where large volumes of DNAPLs were released. Modified inspectional analysis is a technique for developing scaling relationships through nondimensionalizing the governing equations. It was applied in this study to scale observations of DNAPL migration in a laboratory model to four hypothetical scenarios in the field where large volumes of DNAPL were released. One scenario was compared to a large DNAPL spill site. The length and time scales of DNAPL movement predicted from our analysis are consistent with those predicted from a numerical model of this site. To our knowledge, this is the first application of modified inspectional analysis for release of DNAPLs in a laboratory model. This methodology may prove useful for scaling results from other laboratory investigations of DNAPL migration to field-scale systems.  相似文献   

7.
The destruction of a carbon tetrachloride DNAPL and a chloroform DNAPL was investigated in reactions containing 0.5 mL of DNAPL and a solution of modified Fenton's reagent (2M H2O2 and 5mM iron(III)-chelate). Carbon tetrachloride and chloroform masses were followed in the DNAPLs, the aqueous phases, and the off gasses. In addition, the rate of DNAPL destruction was compared to the rate of gas-purge dissolution. Carbon tetrachloride DNAPLs were rapidly destroyed by modified Fenton's reagent at 6.5 times the rate of gas purge dissolution, with 74% of the DNAPL destroyed within 24h. Use of reactions in which a single reactive oxygen species (hydroxyl radical, hydroperoxide anion, or superoxide radical anion) was generated showed that superoxide is the reactive species in modified Fenton's reagent responsible for carbon tetrachloride DNAPL destruction. Chloroform DNAPLs were also destroyed by modified Fenton's reagent, but at a rate slower than the rate of gas purge dissolution. Reactions generating a single reactive oxygen species demonstrated that chloroform destruction was the result of both superoxide and hydroxyl radical activity. Such a mechanism of chloroform DNAPL destruction is in agreement with the slow but relatively equal reactivity of chloroform with both superoxide and hydroxyl radical. The results of this research demonstrate that modified Fenton's reagent can rapidly and effectively destroy DNAPLs of contaminants characterized by minimal reactivity with hydroxyl radical, and should receive more consideration as a DNAPL cleanup technology.  相似文献   

8.
Phase behaviour experiments employing PCB (Aroclor 1242)/alcohol/water systems were conducted with ethanol (EtOH) and n-propanol (nPA). Both exhibited an affinity for the aqueous phase within the entire two-phase region. As much as 88% by volume (88% vol.) EtOH and 80% vol. nPA were necessary to achieve full miscibility of the PCB in the aqueous phase. DNAPL-water interfacial tension (IFT) was reduced from 38.9 dyn/cm to 4.7 dyn/cm and 2.4 dyn/cm with 80% vol. EtOH and 76% vol. nPA. The addition of alcohol brought about 41% and 54% reductions in DNAPL viscosity at maximal concentrations of EtOH and nPA. Density of the PCB-DNAPL was relatively unaffected by the presence of alcohol. A series of seven experiments were conducted where successive slugs of nPA and xanthan gum polymer solutions were injected into a fractured shale sample. A 30% vol. nPA solution injected under a hydraulic gradient of 0.36 allowed enhanced PCB removal primarily through reduction of IFT and resulted in 72% DNAPL recovery. Several pore volumes of alcohol solution were necessary to displace all the potentially mobile non-wetting phase since the high-viscosity DNAPL was mobilized at a lower flow rate than the overall fluid velocity, illustrating non-piston displacement. The injection of a 95% vol. nPA alcohol solution, theoretically at a sufficient concentration to produce fully miscible displacement of the residual DNAPL at equilibrium, resulted in non-equilibrium partitioning of the PCB into the flushing solution, likely due to the high fluid velocities in the fracture. The injection of 200 pore volumes of 95% vol. nPA solution resulted in 94% DNAPL recovery. Alcohol floods operated below the miscibility envelope appear to be a valuable source zone remedial alternative where the objective is to reduce DNAPL mobility to zero, but it should be noted that DNAPL mobility is increased during the application of the technology and steps may need to be taken to prevent unwanted vertical mobilization.  相似文献   

9.
A two-dimensional (2D) laboratory model was used to study effects of gravity on areal recovery of a representative dense non-aqueous phase liquid (DNAPL) contaminant by an alcohol pre-flood and co-solvent flood in dipping aquifers. Recent studies have demonstrated that injection of alcohol and co-solvent solutions can be used to reduce in-situ the density of DNAPL globules and displace the contaminant from the source zone. However, contact with aqueous alcohol reduces interfacial tension and causes DNAPL swelling, thus facilitating risk of uncontrolled downward DNAPL migration. The 2D laboratory model was operated with constant background gradient flow and a DNAPL spill was simulated using tetrachloroethene (PCE). The spill was dispersed to a trapped, immobile PCE saturation by a water flood. Areal PCE recovery was studied using a double-triangle well pattern to simulate a remediation scheme consisting of an alcohol pre-flood using aqueous isobutanol ( approximately 10% vol.) followed by a co-solvent flood using a solution of ethylene glycol (65%) and 1-propanol (35%). Experiments were conducted with the 2D model oriented in the horizontal plane and compared to experiments at the 15 degrees and 30 degrees dip-angle orientations. Injection was applied either in the downward or upward direction of flow. Experimental results were compared to theoretical predictions for flood front stability and used to evaluate effects of gravity on areal PCE recovery. Sensitivity experiments were performed to evaluate effects of the alcohol pre-flood on PCE areal recovery. For experiments conducted with the alcohol pre-flood and the 2D model oriented in the horizontal plane, results indicate that 89-93% of source zone PCE was recovered. With injection oriented downward, results indicate that areal PCE recovery was 70-77% for a 15 degrees dip angle and 57-59% for a 30 degrees dip angle. With injection oriented upward, results indicate that areal PCE recovery was 57-60% at the 30 degrees dip angle, which was similar to PCE recovery for injection in the downward flow direction. Lower areal PCE recovery at greater dip angles in either direction of flow was attributed to DNAPL swelling and migration, flood front instabilities and bypassing of the displaced fluid past the extraction wells during the alcohol pre-flood. Additional results demonstrate that the use of an alcohol pre-flood can be beneficial in improving DNAPL recovery in the horizontal orientation, but pre-flooding may reduce areal recovery efficiency in dip-angle orientations. This study also demonstrates the use of theoretical perturbation (fingering) analysis in predicting NAPL recovery efficiency for flooding processes in remediating aquifers with dip angles.  相似文献   

10.
Zhao B  Zhu L  Yang K 《Chemosphere》2006,62(5):772-779
Efforts to remediate the dense nonaqueous phase liquids (DNAPLs) by mobilizing them face with risks of driving the contaminants deeper into aquifer zones. This spurs research for modifying the approach for in situ remediation. In this paper, a novel solubilization of DNAPLs by mixed nonionic and anionic surfactant, Triton X-100 (TX100) and sodium dodecylbenzene sulfonate (SDBS), was presented and compared with those by single ones. Given 1:40 phase ratio of DNAPL:water (v/v) and the total surfactant concentration from 0.2 to 10gl(-1), mixed TX100-SDBS at the total mass ratios of 3:1, 1:1 and 1:3 exhibited significant solubilization for the DNAPLs, trichloroethene (TCE), chlorobenzene (CB) and 1,2-dichlorobenzene (1,2-DCB). The solubilization extent by mixed TX100-SDBS was much larger than by single TX100 and even larger than by single SDBS at the ratios of 1:1 and 1:3, respectively. TX100 partitioning into the organic phase dictated the solubilization extent. The TX100 losses into TCE, CB and 1,2-DCB phases were more than 99%, 97% and 97% when single TX100 was used. With SDBS alone, no SDBS partitioned into DNAPLs was observed and in mixed systems, SDBS decreased greatly the partition loss of TX100 into DNAPLs. The extent of TX100 partition decreased with increasing the amount of SDBS. The mechanism for reduction of TX100 partition was discussed. TX100 and SDBS formed mixed micelles in the solution phase. The inability of SDBS to partition into DNAPLs and the mutual affinity of SDBS and TX100 in the mixed micelle controlled the partitioning of TX100 into DNAPL phase. The work presented here demonstrates that mixed nonionic-anionic surfactants would be preferred over single surfactants for solubilization remediation of DNAPLs, which could avoid risks of driving the contaminants deeper into aquifers and decrease the surfactant loss and remediation cost.  相似文献   

11.
Modeling field-scale cosolvent flooding for DNAPL source zone remediation   总被引:2,自引:1,他引:1  
A three-dimensional, compositional, multiphase flow simulator was used to model a field-scale test of DNAPL removal by cosolvent flooding. The DNAPL at this site was tetrachloroethylene (PCE), and the flooding solution was an ethanol/water mixture, with up to 95% ethanol. The numerical model, UTCHEM accounts for the equilibrium phase behavior and multiphase flow of a ternary ethanol-PCE-water system. Simulations of enhanced cosolvent flooding using a kinetic interphase mass transfer approach show that when a very high concentration of alcohol is injected, the DNAPL/water/alcohol mixture forms a single phase and local mass transfer limitations become irrelevant. The field simulations were carried out in three steps. At the first level, a simple uncalibrated layered model is developed. This model is capable of roughly reproducing the production well concentrations of alcohol, but not of PCE. A more refined (but uncalibrated) permeability model is able to accurately simulate the breakthrough concentrations of injected alcohol from the production wells, but is unable to accurately predict the PCE removal. The final model uses a calibration of the initial PCE distribution to get good matches with the PCE effluent curves from the extraction wells. It is evident that the effectiveness of DNAPL source zone remediation is mainly affected by characteristics of the spatial heterogeneity of porous media and the variable (and unknown) DNAPL distribution. The inherent uncertainty in the DNAPL distribution at real field sites means that some form of calibration of the initial contaminant distribution will almost always be required to match contaminant effluent breakthrough curves.  相似文献   

12.
表面活性剂强化抽出处理含水层中DNAPL污染物的去除特征   总被引:1,自引:0,他引:1  
为明确表面活性剂强化抽出处理含水层中DNAPL污染物过程中表面活性剂的增强修复效果,及DNAPL自身理化性质和介质孔径的影响,利用数码图像分析技术对1,2-二氯乙烷和四氯乙烯2种DNAPL在石英砂填充的二维砂箱中的抽取迁移过程进行了实验模拟研究,并对抽出水样中DNAPL的浓度进行了测试分析。结果表明,实验条件下加入低浓度(0.18%)的十二烷基苯磺酸钠(SDBS)大幅提高了对弱透水层截留的2种DNAPL聚集体的抽出处理效率。1,2-二氯乙烷在该表面活性剂溶液中的表观溶解度远高于四氯乙烯,因此其短时间内的绝对去除率更高。SDBS强化抽出处理DNAPL的作用机理以增溶作用为主,而其增流作用使DNAPL迁移流动后分布面积增大,增加了与表面活性剂溶液接触的面积,对增溶作用起到促进效果。细粒介质中DNAPL迁移后的最大分布面积较大,因此体系中DNAPL的溶解速率较高。在DNAPL聚集体质量与水力梯度固定的条件下,油水界面张力越低,DNAPL的密度越大,DNAPL垂向迁移的风险就越大。本研究为修复工程中如何依据DNAPL种类与场地多孔介质的情况选择表面活性剂提供了参考。  相似文献   

13.
Phase diagrams were used for the formulation of alcohol–surfactant–solvent and to identify the DNAPL (Dense Non Aqueous Phase Liquid) extraction zones. Four potential extraction zones of Mercier DNAPL, a mixture of heavy aliphatics, aromatics and chlorinated hydrocarbons, were identified but only one microemulsion zone showed satisfactory DNAPL recovery in sand columns. More than 90 sand column experiments were performed and demonstrate that: (1) neither surfactant in water, alcohol–surfactant solutions, nor pure solvent can effectively recover Mercier DNAPL and that only alcohol–surfactant–solvent solutions are efficient; (2) adding salts to alcohol–surfactant or to alcohol–surfactant–solvent solutions does not have a beneficial effect on DNAPL recovery; (3) washing solution formulations are site specific and must be modified if the surface properties of the solids (mineralogy) change locally, or if the interfacial behavior of liquids (type of oil) changes; (4) high solvent concentrations in washing solutions increase DNAPL extraction but also increase their cost and decrease their density dramatically; (5) maximum DNAPL recovery is observed with alcohol–surfactant–solvent formulations which correspond to the maximum solubilization in Zone C of the phase diagram; (6) replacing part of surfactant SAS by the alcohol n-butanol increases washing solution efficiency and decreases the density and the cost of solutions; (7) replacing part of n-butanol by the nonionic surfactant HOES decreases DNAPL recovery and increases the cost of solutions; (8) toluene is a better solvent than D-limonene because it increases DNAPL recovery and decreases the cost of solutions; (9) optimal alcohol–surfactant–solvent solutions contain a mixture of solvents in a mass ratio of toluene to D-limonene of one or two. Injection of 1.5 pore volumes of the optimal washing solution of n-butanol–SAS–toluene–D-limonene in water can recover up to 95% of Mercier DNAPL in sand columns. In the first pore volume of the washing solution recovered in the sand column effluent, the DNAPL is in a water-in-oil microemulsion lighter than the excess aqueous phase (Winsor Type II system), which indicates that part of the DNAPL was mobilized. In the next pore volumes, DNAPL is dissolved in a oil-in-water microemulsion phase and is mobilized in an excess oil phase lighter than the microemulsion (Winsor Type I system). The main drawback of this oil extraction process is the high concentration of ingredients necessary for DNAPL dissolution, which makes the process expensive. Because mobilization of oil seems to occur at the washing solution front, an injection strategy must be developed if there is no impermeable limit at the aquifer base. DNAPL recovery in the field could be less than observed in sand columns because of a smaller sweep efficiency related to field sand heterogeneities. The role of each component in the extraction processes in sand column as well as the Winsor system type have to be better defined for modeling purposes. Injection strategies must be developed to recover ingredients of the washing solution that can remain in the soil at the end of the washing process. ©1997 Elsevier Science B.V.  相似文献   

14.
The transfer of contaminant mass between the nonaqueous- and aqueous-phases is a process of central importance for the remediation of sites contaminated by dense nonaqueous-phase liquids (DNAPLs). This paper describes a comparison of the results obtained with various alternative DNAPL-aqueous-phase mass transfer models contained in the literature for predicting DNAPL source-zone depletion times in groundwater systems. These dissolution models were largely developed through laboratory column experiments. To gain insight into the implications of various representations of the local-scale kinetic as well as equilibrium DNAPL dissolution processes, aquifer heterogeneity and the complex architecture of a DNAPL source-zone, the aqueous-phase contaminant concentrations and mass fluxes arriving at a down-gradient compliance boundary are analyzed in a conditional stochastic framework. The hydrogeologic setting is a heterogeneous fluvial aquifer in Southwest Germany, referred to as the aquifer analog dataset, that was intensively characterized in three dimensions for hydrogeological parameters that include permeability, effective porosity, grain size, mineralogy and sorption coefficients. By embedding the various dissolution models into the compositional, multiphase flow model, CompFlow, the relative times predicted for complete depletion of a released DNAPL source due to natural dissolution are explored. Issues related to achieving environmental benefits through, for example, partial DNAPL-zone source removal via enhanced remedial technologies are also discussed. In this context, performance metrics in the form of peak aqueous-phase contaminant concentrations and mass fluxes arriving at a down-gradient compliance boundary are compared to each other. This is done for each of the alternative mass transfer models. A significant reduction in the fractional flux at a downstream location from the DNAPL source can be achieved by partial source-zone mass reduction; however, peak concentration levels at the same location remain much higher than the United States Environment Protection Agency (US-EPA) drinking water limits. Although groundwater quality was found to improve more rapidly for the equilibrium dissolution model, it is also shown that dissolution models that promote rapid DNAPL disappearance produce greater prediction uncertainty in the aqueous-phase flux reduction.  相似文献   

15.
In-situ oxidation of dense nonaqueous-phase liquids (DNAPLs) by strong oxidants such as potassium permanganate (KMnO4) has been proposed as a possible DNAPL remediation strategy. In this study, we investigated the effects of in-situ trichloroethene (TCE) oxidation by KMnO4 on porous medium hydraulic properties. In particular, we wanted to determine the overall effects of concurrent solid phase (MnO2) precipitation, gas (CO2) evolution and TCE dissolution resulting from the oxidation reaction on the porous medium's aqueous-phase relative permeability, krw. Three TCE removal experiments were conducted in a 95-cm long, 5.1-cm i.d. glass column, which was homogeneously packed with well-characterized 30/40-mesh silica sand. TCE was emplaced in the sand-pack in residual, entrapped form through a sequence of water/TCE imbibition and drainage steps. The column was then flushed under constant aqueous flux conditions for up to 104 h with either deionized water (reference experiment), deionized water containing 5 mM KMnO4 or deionized water containing 5 mM KMnO4 and 300 mM Na2HPO4. Aqueous-phase relative permeabilities were computed from measured flow rates and measurements of aqueous-phase pressure head, h obtained using pressure transducers connected to tensiometers distributed along the column length. A dual-energy gamma radiation system was used to monitor changes in fluid saturation that occurred during each experiment. In addition, column effluent samples were collected for chemical analyses. Dissolution of TCE during deionized water flushing led to an increase in krw by approximately 22% and a local reduction in h. On the other hand, vigorous CO2 gas production and precipitation of MnO2 was visually observed during flushing with deionized water that contained 5 mM KMnO4. As a consequence, krw declined by approximately 96% and h increased locally by more than 1000 cm H2O during the first 24 h of the experiment, causing sand-pack ruptures and pump failure. Conversely, less CO2 gas production and MnO2 precipitation was visually observed during flushing with deionized water that contained 5 mM KMnO4 and 300 mM Na2HPO4. Consequently, only small increases in h (< 15 cm H2O) were observed in this experiment due to a reduction in krw of approximately 53%. While we must attribute changes in h due to variations in krw to our specific experimental design (constant aqueous flux, one-dimensional flow experiments), these experiments nevertheless confirm that successful application of in situ chemical oxidation of TCE requires consideration of detrimental processes such as MnO2 precipitation and CO2 gas formation. In addition, our results indicate that utilization of a buffered oxidant solution may improve the effectiveness of in-situ oxidation of TCE by KMnO4 in otherwise weakly buffered porous media.  相似文献   

16.
In situ chemical oxidation (ISCO) schemes using MnO4- have been effective in destroying chlorinated organic solvents dissolved in ground water. Laboratory experiments and field pilot tests reveal that the precipitation of Mn oxide, one of the reaction products, causes a reduction of permeability, which can lead to flow bypassing and inefficiency of the scheme. Without a solution to this problem of plugging, it is difficult to remove DNAPL from the subsurface completely. In a companion paper, we showed with batch experiments that Mn oxide can be dissolved rapidly with certain organic acids. This study utilizes 2-D flow-tank experiments to examine the possibility of nearly complete DNAPL removal by ISCO with MnO4-, when organic acids are used to remove Mn oxide. The experiments were conducted in a small 2-D glass flow tank containing a lenticular silica-sand medium. Blue-dyed trichloroethylene (TCE) provided residual, the perched and pooled DNAPL. KMnO4 at 200 mg/l was flushed through the DNAPL horizontally. Once plugging reduced permeability and prevented further delivery of the oxidant, citric or oxalic acids were pumped into the flow tank to dissolve the Mn oxide precipitates. Organic ligands removed the Mn oxide precipitates relatively quickly, and permitted another cycle of MnO4- flooding. Cycles of MnO4-/acid flooding continued until all of the visible DNAPL was removed. The experiments were monitored with chemical analysis and visualization. A mass-balance calculation indicated that by the end of the experiments, all the DNAPL was removed. The results show also how heterogeneity adds complexity to initial redistribution of DNAPL, and to the efficiency of the chemical flooding.  相似文献   

17.
We performed an experimental study to quantify the critical conditions for the mobilization of small pools of dense nonaqueous phase liquids (DNAPLs) that may form at capillary-heterogeneity boundaries. A series of experiments were conducted in columns packed with uniform sands arranged to create capillary heterogeneities. DNAPL pools readily formed in these packings and were more easily mobilized than trapped DNAPL ganglia. A model was developed to describe the critical conditions for DNAPL pool mobilization. Pool mobilization was expected when a dimensionless pool trapping number N(T)p> 1 while mobilization was observed in our experiments when N(T)p>0.76+/-0.16 (+/- 95% confidence interval). The difference between the model prediction and the experimental observations was attributed to experimental error. Using this model for DNAPL pool mobilization, a simple numerical experiment was conducted to illustrate use of the model and to explore the effect of scale on the critical conditions for pool mobilization. With an increase in system scale flow bypassing around the DNAPL pool increased and the system-averaged conditions for the onset of mobilization changed: a greater system-average Darcy flux or lower interfacial tensions were required for DNAPL pool mobilization. This result illustrates the importance of system scale on mobilization of DNAPL pools in systems with capillary heterogeneities.  相似文献   

18.
Two-dimensional chamber studies were conducted to determine qualitative and quantitative performance of cosolvents targeted at pooled dense non-aqueous phase liquid (DNAPL) (perchlorethylene, PCE) residing above a fine-grain capillary barrier. Downward mobilization of DNAPL, up gradient along an overriding cosolvent front, was observed. This produced significant pooling above a fine-grain layer that in some cases lead to entry into the capillary barrier beneath. Entry pressure calculations using physical and hydrogeologic parameters provided an excellent prediction of breakthrough of DNAPL into the capillary barrier. Calculations predict approximately 0.5 m of DNAPL would be necessary to enter a Beit Netofa clay, under extreme cosolvent flooding conditions (100% ethanol). Gradient injection of cosolvent did not appear to provide any benefit suggesting a rapid decrease in interfacial tension (IFT) compared to the rate of DNAPL solubilization. Use of a partitioning alcohol (tertiary butyl alcohol, TBA) resulted in DNAPL swelling and reduced entry into the capillary barrier. However, the trapping of flushing solution, containing PCE, could potentially lead to longer remediation times.  相似文献   

19.
When steam is injected into soil containing a dense volatile non-aqueous phase liquid contaminant the DNAPL vaporized within the heated soil region condenses and accumulates ahead of the steam condensation front. If enough DNAPL accumulates, gravitational forces can overcome trapping forces allowing the liquid contaminant to flow downward. By injecting air with steam, a portion of the DNAPL vapor remains suspended in equilibrium with the air, decreasing liquid contaminant accumulation ahead of the steam condensation front, and thus reducing the possibility of downward migration. In this work, a one-dimensional theoretical model is developed to predict the injection ratio of air to steam that will prevent the accumulation of volatile DNAPLs. The contaminated region is modeled as a one-dimensional homogeneous porous medium with an initially uniform distribution of a single component contaminant. Mass and energy balances are combined to determine the injection ratio of air to steam that eliminates accumulation of the contaminant ahead of the steam condensation front, and hence reduces the possibility of downward migration. The minimum injection ratio that eliminates accumulation is defined as the optimum injection ratio. Example calculations are presented for three DNAPLs, carbon tetrachloride (CCl4), trichloroethylene (TCE), and perchloroethylene (PCE). The optimum injection ratio of air to steam is shown to depend on the initial saturation and the volatility of the liquid contaminant. Numerical simulation results are presented to validate the model, and to illustrate downward migration for ratios less than optimum. Optimum injection ratios determined from numerical simulations are shown to be in good agreement with the theoretical model.  相似文献   

20.
A laboratory study was conducted to examine cosolvent-enhanced in-situ chemical oxidation (ISCO) of perchloroethylene (PCE) using potassium permanganate (KMnO4). The conceptual basis for this new technique is to enhance permanganate oxidation of dense non-aqueous phase liquids (DNAPLs) with the addition of a cosolvent, thereby increasing DNAPL solubility while avoiding mobilization. Among 17 cosolvent candidates screened, tertiary butyl alcohol (TBA) and acetone were the most stable in the presence of KMnO4, both of which increased PCE aqueous solubility significantly, and therefore are suitable to be used as cosolvent in this study. Batch experiments indicated that the second-order rate constant for PCE oxidation by potassium permanganate was 0.043+/-0.002 M(-1) s(-1) in the purely aqueous (no cosolvent) solution. In the presence of 20% cosolvent (volume fraction=fc=0.2), the rate constant decreased to 0.036+/-0.003 M(-1) s(-1) with TBA and to 0.031+/-0.002 M(-1) s(-1) with acetone. However, in the presence of free-phase PCE, chloride ion concentration from PCE oxidation in acetone/water solutions (fc=0.2) was about twice that in aqueous solutions, indicating that the increase in PCE solubility more than compensated for the decrease in reaction rate constant, such that the oxidation efficiency of PCE was increased with cosolvent. A complete chlorine mass balance was observed in the aqueous system, whereas approximately 70% was obtained in TBA/water or acetone/water (fc=0.2). In soil columns containing residual DNAPL and subjected to isocratic flushing with step-wise increases in f(c) cosolvent, TBA at fc=0.2 resulted in PCE mobilization, whereas acetone at fc相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号