1.
PCDD/PCDF reduction by the co-combustion process 总被引:1,自引:0,他引:1
A novel process, termed the co-combustion process, has been developed and designed to utilise the thermal treatment of municipal solid waste (MSW) in cement clinker production and reduce PCDD/PCDF emissions. To test the conceptual design; detailed engineering design of the process and equipment was performed and a pilot plant was constructed to treat up to 40 tonnes MSW per day. The novel process features included several units external to the main traditional cement rotary kiln: an external calcinations unit in which the hot gas calcined the limestone thus making significant energy savings for this chemical reaction; the lime generated was used in a second chamber to act as a giant acid gas scrubber to remove SOx and particularly HCl (a source of chloride); an external rotary kiln and secondary combustion unit capable of producing a hot gas at 1200 degrees C; a gas cooler to simulate a boiler turbogenerator set for electricity generation; the incorporation of some of the bottom ash, calcined lime and dust collector solids into the cement clinker. A PCDD/PCDF inventory has been completed for the entire process and measured PCDD/PCDF emissions were 0.001 ng I-TEQ/Nm(3) on average which is 1% of the best practical means [Hong Kong Environmental Protection Department, 2001. A guidance note on the best practicable means for incinerators (municipal waste incineration), BPM12/1] MSW incineration emission limit values. 相似文献
2.
Helena Manninen Annikki Perkiö Terttu Vartiainen Juhani Ruuskanen 《Environmental science and pollution research international》1996,3(3):129-134
One option of recycling used contaminated packaging is to recover its high energy content. This can be performed in a normal multi-fuel power plant by co-combustion of packaging-derived fuel (PDF) or refuse-derived fuel (RDF) with fossil fuels, such as coal or peat. This work includes the results of 17 co-combustion tests and an evaluation of the results by the Principal Component Analysis (PCA) and the Partial Least Squares Projections to Latent Structures (PLS). PCA and PLS calculations showed that especially Pb, but also Cr, and Cu correlated with lower chlorinated furans (PCDFs) in the fly ash. Correlation between Sn and lower chlorinated dioxins (PCDDs) in the fly ash was also noticed. CO and PAH emission in the flue gas correlated with total PCDD/Fs in the flue gas. In a real full-scale combustion process, a single parameter in fuel, flue gas or a combustion parameter did not provide a guide to PCDD/F formation or to a level of the total PCDD/F emission, but correlations between different parameters and PCDD/Fs could be found. Although PDFs and RDF had catalytic heavy metals and chlorine, the co-combustion results showed that they can be co-combusted with peat and coal in a fluidized-bed boiler at least up to 26 % with very low total PCDD and PCDF emissions. 相似文献
3.
Wolf D. Drechsler 《Chemosphere》1986,15(9-12):1529-1534
The physical, chemical and biological processes for the destruction of PCDD/PCDF and the treatment of dioxin-contaminated wastes are reported. Tests and their results, carried out in laboratories and pilot plants with PCDD and similar compounds, are discussed. The development and testing of suitable catalysts for the chemical conversion of dioxins and other chlorohydrocarbons are examined. The application conditions, the necessary pretreatments of wastes, and the destruction efficiencies of the different methods are examined. A technical, economic, and environmental assessment according to the tested results is considered. 相似文献
4.
To investigate the drivers for transport and deposition of 17 2,3,7,8-substituted PCDDs/PCDFs along an urban river, water samples from five reservoirs located along the river course were collected in January and July 2008. The concentrations of 17 congeners of PCDD/PCDF were determined and compared to environmental - physical, chemical and biological - conditions. The obtained data revealed that the concentration of the sum of toxic PCDDs/PCDFs in water samples differ between reservoirs as well as between seasons, ranging from 12.04 pg L(-1) in UP (first in the cascade) to 1327.94 pg L(-1) in PR (last in the cascade) during winter of 2008; and from 34.94 pg L(-1) in UP to 1352.50 pg L(-1) in TR (next to last) in summer 2008. In comparison, water samples collected from the river had a concentration several times lower at the first two sites (sites no. 1 and 4) and no detectable values at the last three stations (sites no. 7, 8, 10). The obtained data demonstrated strong or moderate correlations between the sum of 17 PCDDs/PCDFs and TEQ in reservoir water samples and physical, chemical and biological conditions, such as: Mg(2+) (R=0.82; R=0.80, respectively), SO(4)(2-) (R=0.80; R=0.80, respectively), K(+) (R=0.80; R=0.80, respectively), Ca(2+) (R=0.67, R=0.70, respectively), OSM (R=0.63, R=0.70, respectively). In addition, the positive strong correlation between TEQ concentrations and the water temperature (R=0.63) and chlorophyll a content (R=0.90) was noted. The violent weather conditions occurred during the research season with periods of intensive storm events (up to 32 mm in mid July), and thus the increased river flow velocity (up to 0.45 m(3)s(-1)) could have a direct and indirect influence on PCDDs/PCDFs concentration through changes in the sedimentation/resuspension ratio and consequently in transport, deposition and degradation processes along the river/reservoirs. 相似文献
5.
The emission inventory of PCDD/PCDF in Taiwan 总被引:6,自引:0,他引:6
Chen CM 《Chemosphere》2004,54(10):1413-1420
Establishment of a country or region-based dioxin inventory was considered a crucial step toward elimination of worldwide dioxins/POPs contaminations, although no harmonized method for the preparation of an inventory is available at present. In this study, we used limited data and information to generate an inventory of dioxin emissions from some major sources in Taiwan. A total of 67.25 g I-TEQ of dioxins released annually was estimated. Unlike most of the industrialized countries, municipal waste incineration is not the highest contributor for dioxins released into the atmosphere. In contrast, secondary copper smelting accounts for more than 39% of the total dioxin emissions, and is higher than those from all waste incinerators combined (23.7%). Cement kilns and electric arc furnaces for steels also produced significant portion (both >10%) of dioxins into the environment, followed by secondary aluminum smelting (6.53%), industrial oil combustion (5.02%) and power plants fueled by coal (5.01%). Other known sources are either insignificant with respect to their dioxin emissions or not included in this inventory due to lack of information or uncertainty of the results. Data presented in this report provide a general picture of dioxin emissions in Taiwan, but were mostly based on less reliable or representative information, especially with respect to emission factors from different emission sources. It is necessary to establish background information relative to our own environment at present. Upon available, the inventory should be updated accordingly for proper environmental management on dioxins. 相似文献
6.
PCDD and PCDF were found in urban air particulates from St. Louis and Washington, D.C., and in sediments from the Great Lakes and Siskiwit Lake, Isle Royale. The similarity between the PCDD and PCDF found in air particulates and sediment samples and the presence of PCDD and PCDF in sediment from Siskiwit Lake (a location which can receive only atmospheric inputs) suggest that these compounds are emitted to the atmosphere from combustion sources. The historical input of PCDD and PCDF to dated sediment cores shows a strong increase since 1940, and this suggests that the incineration of chlorinated organic compounds is an important source of PCDD and PCDF to the environment. 相似文献
7.
8.
This paper presents preliminary results of performance tests conducted at the Mid-Connecticut Refuse-Derived Fuel Facility in February 1989. The objectives of these performance tests were to evaluate the effects of combustion and flue gas cleaning process conditions on air pollution emissions and residue properties. 相似文献
9.
PCDD/PCDF,chlorinated pesticides and PAH in Chinese teas 总被引:5,自引:0,他引:5
Four samples of Chinese tea (two green teas, and two brick teas) were analyzed for their concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF), chlorinated pesticides and PAH. The infusions prepared from these teas were also analyzed for PCDD/PCDF. The levels of DDT and its metabolites in tea leaves were within the safety limit of 0.2 mg/kg. Rather high levels of total PAH were obtained in brick tea (1048–1162 mg/kg), when compared with green tea (497–517 mg/kg). In terms of PCDD/PCDF, the concentrations of green tea and brick tea differed by a factor of 16, while the concentrations of all infusions were within a factor of 2. The dioxin concentrations in green tea leaves can be explained through uptake of atmospheric PCDD/PCDF. The higher concentrations in the brick tea leaves are due the longer exposure time, and to certain extent, the use of old leaves, branches and roots when making the tea, and additional components such as soil particulates through contamination. Certain Chinese populations drinking a large amount of brick tea (>3 l per day) indicated that individuals of these populations consume more tea than Europeans or North Americans result in a comparably higher intake of PCDD/PCDF. Tea consumption can attribute to up to 10% of the TDI recommended by WHO (only PCDD/PCDF considered, no PCB analyzed). 相似文献
10.
Studies were conducted to quantify variability for pulp industry wastewater effluent, pulp and sludge analyses. Intralaboratory variability studies indicated that there is a potential for greater between batch variability in results than for within a batch. Intralaboratory relative standard deviations for replicate analyses ranged from 6% to 60%. Interlaboratory studies, using standard reference materials showed relative standard deviations from 4% to 135%. There appeared to be little dependance of variability on concentration, suggesting matrix effects were very important. In general, effluent variability was greater than observed for pulps or sludges. Analysis of reference standards indicated that 13% to 17% variability can be attributed to differences in calibration standards. A limited study of full congener PCDD/PCDF analysis variability showed it to be greater than observed for TCDD/TCDF. 相似文献
11.
《Chemosphere》1987,16(6):1221-1230
The emission and chlorination pattern of polychlorinated dioxins and dibenzofurans from waste combustion shows a close covariation with that of chlorinated benzenes and phenols. This covariation can be utilized to predict the emission levels of specific isomers as well as the pattern of congeners. 相似文献
12.
In recent years, pyrolysis processes have become technologies developed to industrial scale and discussed as alternatives to the existing waste combustion technology. However, little information is published regarding PCDD/F formation characteristics during pyrolysis processes. Two common shredder fractions – industrial light shredder (ILS) and refrigerators (REF) – both with high chlorine and copper content were pyrolysed for this pyrolysis study using a pilot plant with a capacity of 100 kg/h. At oxygen concentrations below 2% and temperatures between 430°C and 470°C, considerable amounts of PCDD/F were formed during the pyrolysis. More than 90% of total TEQ was found in the oil fraction (gas phase). The PCDD/PCDF ratio and the homologue pattern differed significantly from those formed during waste incineration. Considering mono- to octachlorinated congeners, up to 400 times more PCDF were formed compared to PCDD. For the investigated pyrolysis conditions, the formation of low chlorinated congeners was highly favoured. The distribution of TEQ within the individual congeners were very similar in all investigated runs. More than 80% of total TEQ stem from 2,3,7,8-substituted T4CDF and P5CDF. The isomer pattern, however, did not show significant differences compared to the common waste incineration pattern suggesting that the basic formation routes are similar. 相似文献
13.
Chovancová J Conka K Fabišiková A Sejáková ZS Dömötörová M Drobná B Wimmerová S 《Chemosphere》2012,88(11):1383-1389
Blood serum specimens from 81 non-occupationally exposed adults residing in four areas close to municipal and waste incinerators as well as metallurgical industry plant and 44 adult subjects coming from control area of Slovakia were analysed for polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and polybrominated diphenylethers (PBDEs). The concentration of total WHO(98)TEQ PCDD/F/dl-PCBs in whole group of donors from areas where known sources causing dioxin contamination are present was significantly higher than in control group of donors (p<0.001). Correlation between the age of donors and PCDD/F and dl-PCB levels was confirmed (Spearman's r(PCDD/Fs)=0.543, r(dl-PCBs)=0.521, p<0.001). Furthermore, this study presents first results concerning the PBDE congeners in human serum of Slovak general population. The total concentration (congeners 28, 47, 99, 100, 153, 154, 183) in control group was approximately 1.5-times higher in comparison to that of residents coming from areas with supposed environmental pollution. The most abundant congeners in all samples were BDE-47 and BDE-153 with median values of 0.24 ng g(-1) lipid and 0.23ngg(-1) lipid, respectively. The positive association between PBDE values and age of donors was not found. 相似文献
14.
The native carbon oxidation and PolyChloroDibenzo-p-Dioxins and PolyChloroDibenzoFurans, PCDD/F, formation were simultaneously studied at different temperatures (230-350 degrees C) and times (0-1440 min) in order to establish a direct correlation between the disappearance of the reagent and the formation of the products. The kinetic runs were conducted in an experimental set up where conditions were chosen to gain information on the role of fly ash deposits in cold zones of municipal solid waste incinerators in PCDD/F formation reaction. The carbon oxidation measured as the decrease of total organic carbon of fly ash was in agreement with the carbon evolved as sum of CO and CO(2). The carbon mass balance indicated an increase in the efficiency of carbon conversion in CO and CO(2) with temperature. The CO and CO(2) formation was the result of two parallel pseudo first order reactions thus giving significant information about the reaction mechanism. PCDD/F formation as a function of temperature showed that the maximum formation was achieved in a narrow range around 280 degrees C; the time effect at 280 degrees C was a progressive formation increase at least up to 900 min. The PCDF:PCDD molar ratio increased with temperature and time, and the most abundant homologues were HxCDD, HpCDD, OCDD for PCDD, and HxCDF, HpCDF within PCDF. These experimental results supported the hypothesis that the formation mechanism was the de novo synthesis. 相似文献
15.
A number of different pretreatment and extraction procedures were compared with regard to recovery of PCDD/PCDF from fly ash. Highest results were obtained using an acid digestion with excess dilute HCl, followed by freeze drying of the residue and hot extraction by toluene. 相似文献
16.
The effect of thermal treatment of fly ash on the behaviour of PCDD/PCDF was studied in the range between 120 and 600° C. Annealing at 300° C (2 hrs) resulted in an increase of PCDD/PCDF concentration by a factor of 10 to 15. At 600° C degradation to concentrations below 0.1 ng/g is observed. 相似文献
17.
Congener profiles are the fractional distribution of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) congeners in an environmental release, or in an environmental or biological sample. In 1999, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an old municipal solid waste incinerator (MSWI) from Montcada (Barcelona, Spain). The main goal of the present study was to determine if the environmental PCDD/F levels in the area under direct influence of the facility were mainly due to PCDD/F emissions from the plant. For this purpose, soil and herbage samples were collected near the MSWI before (1998) and after (2000) the technical improvements were performed. PCDD/F congener profiles were determined and compared with those from samples collected in a suburban area of Constantí (Tarragona, Spain) outside of direct emissions from any MSWI. The results of the present study suggest that the MSWI here assessed is not the main responsible for the environmental PCDD/F concentrations in the area under evaluation. Other PCDD/F emission sources in the same area seem also to have a notable impact on the atmospheric levels of these pollutants. 相似文献
18.
Colombo A Benfenati E Bugatti SG Celeste G Lodi M Rotella G Senese V Fanelli R 《Chemosphere》2011,85(11):1719-1724
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination. 相似文献
19.
In Germany, there is a lack of consistent and comparable data for the time dependent behaviour and spatial distribution of dioxin-like and indicator PCB in ambient air, deposition and plants. The aim of this study was to improve the data on PCDD/PCDF, dioxin-like PCB and non dioxin-like PCB in spruce and pine shoots from different locations and years by retrospective monitoring. The survey was conducted with archived samples of one-year old spruce shoots (Picea abies) and pine shoots (Pinus sylvestris) from the German environmental specimen bank. Two sets of samples from locations in urbanized areas in western and eastern Germany (Warndt and Duebener Heide Mitte, respectively) were investigated as time series. Additionally, spruce shoots from seven different rural locations sampled in the years 2000-2004 were analyzed in order to get an overview about the spatial distribution of PCB and PCDD/PCDF. The analytical results of the samples from the two urbanized areas clearly show that the atmospheric contamination with PCDD and PCDF has declined by about 75% between 1985 and 1997 at Warndt and about 40% between 1991 and 1997 at Duebener Heide. However, concentrations stayed virtually constant at both locations from 1997 to 2004 at a level of about 1 ng WHO-TEQ/kg dry matter (d.m.). Similarly, the investigation of spruce shoots from rural locations from 2000 to 2004 did not reveal a temporal trend at any site. PCDD/PCDF levels were between 0.1 and 1.0 ng WHO-TEQ/kg d.m. At the urbanized location Warndt the six indicator PCB as well as the 12 dioxin-like PCB according to WHO revealed a significant decline by more than 75% between 1985 and 1999. Thereafter, PCB levels stayed virtually constant. At the location Duebener Heide an overall decrease of PCB concentrations in pine shoots of about 60% was detected between 1991 and 2004. Spruce shoots from all locations showed a relevant contribution of dioxin-like PCB to the total WHO toxicity equivalent (PCDD/PCDF+PCB). In most samples, the contribution of dioxin-like PCB was between 21% and 41%. The TEQ contribution of PCB in the samples from three rural sites was higher and similar to the TEQ value of PCDD/PCDF. The investigated pine shoots from the urbanized site Duebener Heide showed a 15-28% contribution of dioxin-like PCB to total TEQ and thus lower than in spruce shoots from different locations. In all samples except one PCB 126 contributed to more than 80% to the PCB-TEQ. 相似文献
20.
《Chemosphere》2012,86(11):1719-1724
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination. 相似文献