首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this article, numerical simulations and observational analyses have been made for the aerosol episode that occurred over the Pearl River Delta (PRD) region in China during 1–3 November 2003. An air quality modeling system that consisted of the mesoscale model MM5, chemical transport model MODELS-3/CMAQ, and air pollutant emission model SMOKE, was employed. Studies have shown that this particulate matter (PM) pollution episode was apparently associated with the activity of tropical cyclone (TC) Melor. Model simulations revealed that Melor spawned this PM episode through dynamic and thermodynamic processes. The strong compensating subsidence induced by Melor's peripheral circulations created favorable meteorological conditions that enhanced local aerosol pollution. This strong downward motion produced significant adiabatic warming (2–4 °C daily) and dramatic drying in the low-level troposphere over the PRD. As a result, the PRD region was blanketed with a dry and warm air layer that strengthened the static stability of the lower troposphere. The descending motion also tended to dramatically lower the heights of the planetary boundary layer (PBL) through its dynamic effect. The fair weather created by this synoptic pattern further intensified the nocturnal temperature inversions through enhanced radiative cooling. All of these factors promoted a stagnant local atmosphere with very light winds near the surface. The horizontal and vertical dispersions of locally emitted aerosol particles were largely suppressed, leading to the accumulation of large amounts of PMs near local emission sources in the PRD region. As Melor drew near, changes in surface winds strengthened the horizontal transport of aerosol particles from inland sources to the area of Hong Kong downstream. This horizontal advection greatly contributed to the high PM10 (particulate matters less than 10 μm in diameters) concentrations in Hong Kong.  相似文献   

2.
A modelling study with the on-line coupled Eulerian chemical-weather model WRF/Chem for the Southern Italian region around Cosenza (Calabria) was conducted to identify the influences of synoptic scale meteorology, local scale wind systems and local emissions on ozone concentrations in this orographically complex region. Four periods of 5–7 days were chosen, one from each season, which had wind pattern characteristics representative of typical local climatological conditions, in order to study the local versus non-local impacts on ozone transport and formation. To account for the complex terrain, the horizontal resolution of the smallest modelling domain was 3 km. Model results were compared with measurements to demonstrate the capability of the model to reproduce ozone concentrations in the region. The comparison was favourable with a mean bias of ?1.1 ppb. The importance of local emissions on ozone formation and destruction was identified with the use of three different emission scenarios. Generally the influence of regional emissions on the average ozone concentration was small. However during periods when mountain-sea wind systems were well developed and synoptic scale winds were weak, the influence of local emissions from the urban area was at its greatest. The maximum influence of local emissions on ozone concentrations was 18 ppb.  相似文献   

3.
In this paper the meteorological processes responsible for transporting tracer during the second ETEX (European Tracer EXperiment) release are determined using the UK Met Office Unified Model (UM). The UM predicted distribution of tracer is also compared with observations from the ETEX campaign. The dominant meteorological process is a warm conveyor belt which transports large amounts of tracer away from the surface up to a height of 4 km over a 36 h period. Convection is also an important process, transporting tracer to heights of up to 8 km. Potential sources of error when using an operational numerical weather prediction model to forecast air quality are also investigated. These potential sources of error include model dynamics, model resolution and model physics. In the UM a semi-Lagrangian monotonic advection scheme is used with cubic polynomial interpolation. This can predict unrealistic negative values of tracer which are subsequently set to zero, and hence results in an overprediction of tracer concentrations. In order to conserve mass in the UM tracer simulations it was necessary to include a flux corrected transport method. Model resolution can also affect the accuracy of predicted tracer distributions. Low resolution simulations (50 km grid length) were unable to resolve a change in wind direction observed during ETEX 2, this led to an error in the transport direction and hence an error in tracer distribution. High resolution simulations (12 km grid length) captured the change in wind direction and hence produced a tracer distribution that compared better with the observations. The representation of convective mixing was found to have a large effect on the vertical transport of tracer. Turning off the convective mixing parameterisation in the UM significantly reduced the vertical transport of tracer. Finally, air quality forecasts were found to be sensitive to the timing of synoptic scale features. Errors in the position of the cold front relative to the tracer release location of only 1 h resulted in changes in the predicted tracer concentrations that were of the same order of magnitude as the absolute tracer concentrations.  相似文献   

4.
The nocturnal boundary layer in Houston, Texas was studied using a high temporal and vertical resolution tethersonde system on four nights during the Texas Air Quality Study II (TexAQS II) in August and September 2006. The launch site was on the University of Houston campus located approximately 4 km from downtown Houston. Of particular interest was the evolution of the nocturnal surface inversion and the wind flows within the boundary layer. The land–sea breeze oscillation in Houston has important implications for air quality as the cycle can impact ozone concentrations through pollutant advection and recirculation. The results showed that a weakly stable surface inversion averaging in depth between 145 and 200 m AGL formed on each of the experiment nights, typically within 2–3 h after sunset. Tethersonde vertical winds were compared with two other Houston data sets (High Resolution Doppler Lidar and radar wind profiler) from locations near the coastline and good agreement was found, albeit with a temporal lag at the tethersonde site. This comparison revealed development of a land breeze on three nights which began near the coastline and propagated inland both horizontally and vertically with time. The vertical temperature structure was significantly modified on one night at the tethersonde site after the land breeze wind shift, exhibiting near-adiabatic profiles below 100 m AGL.  相似文献   

5.
Enhanced ozone values observed in the upper troposphere near intense tropical cyclones have raised the question of the role of stratospheric–tropospheric exchange. The dynamical mechanisms involved in the enhanced ozone values of 6 April 1995 observed at Reunion and associated with the tropical cyclone Marlene could not be explained by ECMWF meteorological analysis with 1.125° horizontal resolution. A previous study based on the ECHAM model has demonstrated the impact of biomass burning, but of limited amplitude (<60–80 ppbv max). In this paper, the upper tropospheric ozone enhancement on the periphery of Marlene has been studied with a mesoscale model (MESO-NH). This model is able to reproduce a stratospheric PV filament into the troposphere, crossing the isentropes to the 350 K level. The ageostrophic circulation associated with divergence zones that have induced vertical movements has been shown. Further, the influence of vertical wind shear, evident in both the mesoscale analysis and in the idealized HURRICANE tropical cyclone model, also contributes to our understanding of this downward transport process.  相似文献   

6.
Nocturnal chemistry can play an important role in determining the initial morning conditions for daytime chemistry in urban areas. However, the impact on daytime O3 levels is difficult to assess as the suppression of vertical trace gas transport leads to highly altitude dependent nocturnal chemistry, in particular with respect to the removal and conversion of nitrogen oxides (NOx) and volatile organic compounds (VOC). One-dimensional (1-D) chemical transport model calculations for different nighttime vertical stabilities and different ozone formation regimes (i.e. NOx- vs. VOC-sensitive) were performed assuming a 1000 m high daytime boundary layer and a growing nocturnal boundary layer reaching 200 m height at the end of the night. Exclusion of NO3 chemistry from the model leads to daytime O3 concentration changes from ?4% to +16% for different O3 sensitivities. In all cases strong nocturnal vertical concentration profiles of NOx, O3, NO3 and N2O5 and a dependence of these profiles on vertical stability were found at night. The nocturnal NOx loss averaged over the lowest 1000 m changes by 9–24% for different vertical stabilities and ozone sensitivities. The impact of nocturnal vertical stability leads to 7–12% difference in O3 concentration in the morning and ~0–2.5% in the afternoon.  相似文献   

7.
A 20-m Asian dust monitoring tower was installed at Erdene in Dornogobi, Mongolia in later 2008, which is one of the high Asian dust source regions in the Asian domain, to investigate meteorological conditions for the dust events. The tower was equipped with meteorological sensors (temperature, humidity and wind speed at four levels, precipitation and pressure near the surface), radiation sensors (solar radiation, net radiation) and soil measurement sensors (soil moisture and soil temperature at three levels and soil heat flux at one level) and turbulent measurement (sonic anemometer) at the 8 m height and PM10 concentration measurement (beta guage) at the 3 m height. Measurement was made for a full year of 2009. The observed data indicated that dust events occur all year round with the maximum hourly mean maximum concentration of 4107 μg m?3 in the early May to a minimum of 92 μg m?3 in later August. It was found that the dust concentration at this site is directly related to the wind speed exceeding the threshold wind speed (likewise the corresponding friction velocity) during the winter to early spring. However, the observed dust concentration is not only related to the wind speed exceeding the threshold wind speed but also to the Normalized Difference Vegetation Index (NDVI) during the late spring to the late autumn due to the growth of vegetation. It was also found that the surface soil moisture content does not affect the dust concentration due to the relatively short residence time of the soil moisture in the surface soil. The presently monitored data can be used to verify parameters used in the Asian Dust Aerosol Model (ADAM) that is the operational forecasting dust model in the Korea Meteorological Administration (KMA).  相似文献   

8.
Following a request by environmental authorities in New Zealand, atmospheric modelling has been applied to delimitation of clean air zones for urban areas. This approach involved the integration of a kinematic trajectory model with an atmospheric mesoscale model to identify the spatial extent of the catchment of air affecting air pollution concentrations in Christchurch on nights of high air pollution. The Regional Atmospheric Modelling System (RAMS) was configured for the region and idealised simulations performed to obtain predicted wind fields for synoptic situations typical of winter smog events. The predicted surface wind fields on two grids, with horizontal resolutions of 1.5 and 0.5 km, respectively, were then used to derive back-trajectories from the late evening peak of pollution over the central city (around 2200 NZST) to the time at which people tend to first light their domestic fires (around 1800 NZST). The results indicate that although winds are often light, the air tends to travel from a significant distance outside the city boundary over this time period. In particular, cold air typically travels up to 20 km from the Canterbury Plains to the west into the city during these air pollution events, as well as from small valleys in the Port Hills to the south of the city. This research illustrates the significance of upstream sources of air for providing relatively clean air to the city, and acting as buffer zones. It is, therefore, possible to identify the area around the city to which urban air quality is particularly sensitive. This area could either be designated as a buffer zone, or included within the clean air zone of the city. This technique also provides a useful tool for identifying the role of different components of the local wind field responsible for air pollution dispersion and transport in different parts of the area.  相似文献   

9.
Frequent high ozone days (defined as daily maximum ozone concentration ⩾80 ppb) during recent years in the Taichung Basin have caused much concern. High ozone days occur mainly during autumn and spring. Statistically, there is no clear linear relationship between a single meteorological variable and ozone concentration. In this study, data from 1996–2000 has shown that high ozone concentrations occur during two types of synoptic weather patterns. The first type is a continental cyclone emanating from mainland China, the southern part of it swept towards Taiwan by easterly winds. The second pattern is a tropical depression moving northwards toward the region, the northern part of it affecting Taiwan via easterly winds. Both types cover Taiwan with easterly winds, which are blocked by the Central Mountain Ranges (altitude of 2000–3000 m). The ranges create lee cyclogenesis to the west, which is unfavorable for pollutant dispersion and leads to serious air pollution episodes.The statistical results of the synoptic weather patterns in relation to ozone concentrations are based on the 5 yr data (1996–2000). This was obtained from a network of air-pollution monitoring sites in the study area, while the vertical data come from two 3-day tethersonde experimental campaigns conducted during March and October 2000, measuring air pressure, air temperature, relative humidity, wind speed and direction, non-methane hydrocarbons, NOx and O3.  相似文献   

10.
Measurement of ambient gas-phase total peroxides was performed at the summit of Mount Tai (Mt. Tai, 1534 m above sea level) in central-eastern China during March 22–April 24 and June 16–July 20, 2007. The hourly averaged concentration of peroxides was 0.17 ppbv (± 0.16 ppbv, maximum: 1.28 ppbv) and 0.55 ppbv (± 0.67 ppbv, maximum: 3.55 ppbv) in the spring and summer campaigns, respectively. The average concentration of peroxides at Mt. Tai, which is in a heavily polluted region, was much lower than hydrogen peroxide measurements made at some rural mountain sites, suggesting that significant removal processes took place in this region. An examination of diurnal variation and a correlation analysis suggest that these removal processes could include chemical suppression of peroxide production due to the scavenging of peroxy and hydroxy radicals by high NOx, wet removal by clouds/fogs rich in dissolved sulfur dioxide which reacts quickly with peroxides, and photolysis. These sinks competed with photochemical sources of peroxides, resulting in different mean concentrations and diurnal pattern of peroxides in the spring and summer. A principal component analysis was conducted to quantify the major processes that influenced the variation of peroxide concentrations. This analysis shows that in the spring photochemical production was an important source of peroxides, and the major sink was scavenging during upslope transport of polluted and humid air from the lower part of the planetary boundary layer (PBL) and wet removal by synoptic scale clouds. During the summer, highly polluted PBL air (with high NOx) was often associated with very low peroxides due to the chemical suppression of HO2 by high NOx and wet-removal by clouds/fogs in this sulfur-rich atmosphere, especially during the daytime. Higher concentrations of peroxides, which often appeared at mid-nighttime, were mainly associated with subsidence of air masses containing relatively lower concentrations of NOy.  相似文献   

11.
In this study, aerosol vertical distributions of 17 in-situ aircraft measurements during 2005 and 2006 springs are analyzed. The 17 flights are carefully selected to exclude dust events, and the analyses are focused on the vertical distributions of aerosol particles associated with anthropogenic activities. The results show that the vertical distributions of aerosol particles are strongly affected by weather and meteorological conditions, and 3 different types of aerosol vertical distributions corresponding to different weather systems are defined in this study. The measurement with a flat vertical gradient and low surface aerosol concentrations is defined as type-1; a gradual decrease of aerosols with altitudes and modest surface aerosol concentrations is defined as type-2; a sharp vertical gradient (aerosols being strongly depressed in the PBL) with high surface aerosol concentrations is defined as type-3. The weather conditions corresponding to the 3 different aerosol types are high pressure, between two high pressures, and low pressure systems (frontal inversions), respectively. The vertical mixing and horizontal transport for the 3 different vertical distributions are analyzed. Under the type-1 condition, the vertical mixing and horizontal transport were rapid, leading to strong dilution of aerosols in both vertical and horizontal directions. As a result, the aerosol concentrations in PBL (planetary boundary layer) were very low, and the vertical distribution was flat. Under the type-2 condition, the vertical mixing was strong and there was no strong barrier at the PBL height. The horizontal transport (wind flux) was modest. As a result, the aerosol concentrations were gradually reduced with altitude, with modest surface aerosol concentrations. Under the type-3 condition, there was a cold front near the region. As a result, a frontal inversion associated with weak vertical mixing appeared at the top of the inversion layer, forming a very strong barrier to prevent aerosol particles being exchanged from the PBL height to the free troposphere. As a result, the aerosol particles were strongly depressed in the PBL height, producing high surface aerosol concentrations. The measured vertical aerosol distributions have important implications for studying the effects of aerosols on photochemistry. The J[O3] values are reduced by 11%, 48%, and 50%, under the type-1, type-2, and type-3 conditions, respectively. This result reveals that atmospheric oxidant capacity (OH concentrations) is modestly reduced under the type-1 condition, but is significantly reduced under the type-2 and type-3 conditions. This result also suggests that the effect of aerosol particles on surface solar flux is an integrated column effect, and detailed vertical distributions of aerosol particles are very important for assessing the impacts of aerosol on photochemistry.  相似文献   

12.
During NATO's 78-day Kosovo war, 24 March–10 June 1999, almost daily attacks on major industrial sources have caused numerous industrial accidents in Serbia. These accidents resulted in releases of many hazardous chemical substances including the persistent organic pollutants (POPs). Detection of some important POPs in fine aerosol form took place at Xanthi in Greece and reported to the scientific world. The paper focuses on two pollution episodes: (a) 6–8 April; and (b) 18–20 April. Using the Eta model trajectory analysis, the regional pollutant transport from industrial sites in Northern Serbia (Novi Sad) and in the Belgrade vicinity (Pančevo), respectively, almost simultaneously bombed at midnight between 17 and 18 April, corroborated measurements at Xanthi. At the same time the pollutant puff was picked up at about 3000 m and transported to Bulgaria, Romania, Ukraine, Moldavia and the Black Sea. The low-level trajectories from Pančevo below 1000 m show pollutant transport towards Belgrade area in the first 12 h. The POP washout in central and southern Serbia in the second episode was deemed to have constituted the principal removal mechanism. Maximum POP wet deposition was found in central Serbia and along the 850 hPa trajectory towards south-eastern Serbia and the Bulgarian border.  相似文献   

13.
The temporal and spatial distributions of boundary-layer ozone were studied during June 2000 at Summit, Greenland, using surface-level measurements and vertical profiling from a tethered balloon platform. Three weeks of continuous ozone surface data, 133 meteorological vertical profile data and 82 ozone vertical profile data sets were collected from the surface to a maximum altitude of 1400 m above ground.The lower atmosphere at Summit was characterized by the prevalence of strong stable conditions with strong surface temperature inversions. These inversions reversed to neutral to slightly unstable conditions between ∼9.00 and 18.00 h local time with the formation of shallow mixing heights of ∼70–250 m above the surface.The surface ozone mixing ratio ranged from 39 to 68 ppbv and occasionally had rapid changes of up to 20 ppb in 12 h. The diurnal mean ozone mixing ratio showed diurnal trends indicating meteorological and photochemical controls of surface ozone. Vertical profiles were within the range of 37–76 ppb and showed strong stratification in the lower troposphere. A high correlation of high ozone/low water vapor air masses indicated the transport of high tropospheric/low stratospheric air into the lower boundary layer. A ∼0.1–3 ppb decline of the ozone mixing ratio towards the surface was frequently observed within the neutrally stable mixed layer during midday hours. These data suggest that the boundary-layer ozone mixing ratio and ozone depletion and deposition to the snowpack are influenced by photochemical processes and/or transport phenomena that follow diurnal dependencies. With 37 ppb of ozone being the lowest mixing ratio measured in all data no evidence was seen for the occurrence of ozone depletion episodes similar to those that have been reported within the boundary layer at coastal Arctic sites during springtime.  相似文献   

14.
Intensive field investigations were conducted at the summit of Mount Tai in June 2006 to understand the effects of the local and regional sources on atmospheric volatile organic compounds (VOCs) distributions. A total of 60 samples were collected and determined by quantitative analytical methods. The concentrations of the total VOCs (TVOCs) observed in the air of Mount Tai were 6.95 ± 5.71 ppb. Aromatic hydrocarbons provided the largest contribution to TVOCs, followed by alkanes and halocarbons. High levels of halocarbons accounted for 20% of TVOCs due to emission from a PVC plant located at the foot of Mount Tai. Alkenes and cycloalkanes contributed little to the total VOCs. The day-and-night differences and day-to-day variations in the concentrations of four selected species were investigated and the effects of several factors such as meteorological parameters, sources and transport characteristics on them were discussed in details. A back trajectory analysis showed that relatively higher levels of VOCs were related to long-range transport of pollutants from polluted areas. The vertical motions of air masses also had a large impact on the variations of the levels of VOCs. The result of the variability–lifetime relationships of VOCs, which is used to estimate the remoteness of the sampling location, showed that Mount Tai represents intermediate conditions between remote sites and sites in the vicinity of sources.  相似文献   

15.
Causes for the unusually high and seasonally anomalous ozone concentrations at Summit, Greenland were investigated. Surface data from continuous monitoring, ozone sonde data, tethered balloon vertical profiling data, correlation of ozone with the radionuclide tracers 7Be and 210Pb, and synoptic transport analysis were used to identify processes that contribute to sources and sinks of ozone at Summit. Northern Hemisphere (NH) lower free troposphere ozone mixing ratios in the polar regions are ∼20 ppbv higher than in Antarctica. Ozone at Summit, which is at 3212 m above sea level, reflects its altitude location in the lower free troposphere. Transport events that bring high ozone and dry air, likely from lower stratospheric/higher tropospheric origin, were observed ∼40% of time during June 2000. Comparison of ozone enhancements with radionuclide tracer records shows a year-round correlation of ozone with the stratospheric tracer 7Be. Summit lacks the episodic, sunrise ozone depletion events, which were found to reduce the annual, median ozone at NH coastal sites by up to ∼3 ppbv. Synoptic trajectory analyses indicated that, under selected conditions, Summit encounters polluted continental air with increased ozone from central and western Europe. Low ozone surface deposition fluxes over long distances upwind of Summit reduce ozone deposition losses in comparison to other NH sites, particularly during the summer months. Surface-layer photochemical ozone production does not appear to have a noticeable influence on Summit's ozone levels.  相似文献   

16.
This study examines the spatial distribution of potential recirculation over the East Mediterranean Sea, and the combined effect of synoptic and meso-scale recirculations on plume dispersion in the region. For this purpose, three case studies are performed by the RAMS–HYPACT modeling system, each for a different synoptic scale flow pattern. Both a quantitative measure of the recirculation potential at each grid cell and particle dispersion are calculated. Although the recirculation index is an Eulerian quantity for the wind field and plume dispersion is a manifestation of the Lagrangian behavior of the wind, good correlation is found between the two.Several locations are identified as having high recirculation potential, including southern Cyprus, the coasts of Israel and Lebanon, the eastern slopes of the Judean Mountains and the Haifa Bay in particular. In the latter location, high recirculation potential could be explained by strong interaction between the land–sea surfaces, curvature of the bay and proximity of the Carmel ridge. It is shown that the synoptic and meso-scale recirculations may, under certain conditions, act together and at the same time in determining particle distribution. Under weak synoptic scale flows, particles are recirculated over the entire East Mediterranean Sea basin, returning onshore after a period of 2–3 days to join freshly emitted particles. At the same time, near-shore land–sea breeze effects cause particles to recirculate on smaller time scales of less then one day, sometimes passing as much as three times over the same airshed. A single elevated emission source is shown to have the potential to impair air quality at a coastal strip as long as 100–200 km upon returning onshore.  相似文献   

17.
The integrated process rates (IPRs) estimated by the Eta–CMAQ model at grid cells along the trajectory of the air mass transport path were analyzed to quantitatively investigate the relative importance of physical and chemical processes for O3 formation and evolution over the northeastern U.S. during the 2004 International Consortium for Atmospheric Research on Transport and Transformation (ICARTT) period. The Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model is used to determine the back trajectory of air masses reaching the northeast by linking a downwind receptor to upwind source areas. The process analysis is applied to a high O3 episode occurring on July 22, 2004 at three selected sites in the northeastern U.S. The process analysis at the location of the site shows that during the daytime, the O3 concentrations in the surface layer are mainly enhanced by the vertical diffusion of O3-rich air from aloft, followed by horizontal advection (HADV) and chemical production (CHEM), whereas dry deposition (DDEP) and vertical advection (ZADV) mainly deplete O3 concentrations at the sites of Valley Central (VC), NY and Castle Spring (CS), NH. By integrating the effects of each process over the depth of the daytime planetary boundary layer (PBL), it was found that at the VC site, CHEM and HADV contributed about 53% and 41%, respectively, to O3 levels within the PBL. This confirms the significance of regional transport of O3 from the industrialized areas into the Northeast. On the other hand, the process analysis results for O3 formation in moving air masses indicate that on July 22, large chemical production of O3 along the transport path over the polluted urban regions leads to significant increase in O3 in the air mass reaching the VC site, whereas the low chemical production of O3 along the transport path over the low emission regions leads to the low O3 concentration at the site of Belleayre Mountain (BM), NY. The dramatic buildup of O3 concentration from 50 ppb to 102 ppb in the air masses before reaching the VC site after 12:00 EST on 7/22 indicates the significant impact of pollution from the northeastern urban corridor at this site. On the basis of the results at the CS site, it was found that high NOx emissions along the transport path led to large chemical production of O3 in the air mass reaching the CS site on July 22. In contrast, the low chemical production of O3 associated with low emission (relatively clean conditions) along the transport path over the northern portions of the domain is responsible for the low O3 concentration at the CS site on July 26.  相似文献   

18.
According to regulations, sows with piglets on organic farms must graze on pastures. Volatilization of ammonia (NH3) from urine patches may represent a significant source of nitrogen (N) loss from these farms. Inputs of N are low on organic farms and losses may reduce crop production. This study examined spatial variations in NH3 volatilization using a movable dynamic chamber, and the pH and total ammoniacal nitrogen (TAN) content in the topsoil of pastures with grazing sows was measured during five periods between June 1998 and May 1999. Gross NH3 volatilization from the pastures was also measured with an atmospheric mass balance technique during seven periods from September 1997 until June 1999. The dynamic chamber study showed a high variation in NH3 volatilization because of the distribution of urine; losses were between 0 and 2.8 g NH3–N m−2 day−1. Volatilization was highest near the feeding area and the huts, where the sows tended to urinate. Ammonia volatilization rate was linearly related to the product of NH3 concentration in the boundary layer and wind speed. The NH3 in the boundary layer was in equilibrium with NH3 in soil solution. Gross NH3 volatilization was in the range 0.07–2.1 kg NH3–N ha−1 day−1 from a pasture with 24 sows ha−1. Ammonia volatilization was related to the amount of feed given to the sows, incident solar radiation and air temperature during measuring periods, and also to temperature, incident solar radiation and rain 1–2 days before measurements. Annual ammonia loss was 4.8 kg NH3–N sow−1.  相似文献   

19.
The multiple nested three-dimensional (3D) mesoscale Eulerian grid point model MM5 is directly coupled with a Lagrangian particle trajectory model in order to perform a four-dimensional source attribution for the area of Berlin based on the horizontal distribution of the import probability density (IPD). The technical aspects are already demonstrated in the companion paper A (Part I) including the illustration of the meteorological situation at the two consecutive days of investigation and a primarily 3D source attribution. We conducted further sensitivity studies concerning the effect of vertical mixing, the static stability of the particles/emissions and the regarded time scale on the IPD distribution which is extended to four dimensions. The main results are:
  • •Heterogeneity and temporal variability of the wind field enhance the contributions of nearby sources (emissions) to the total import of the receptor in contrast to stationary wind fields which increase the scope of the IPD distribution in the upstream direction.
  • •Regions of static stability, for example morning hour inversion layers, enhance the contribution of far distance sources with longer import times.
  • •The import velocities increase, as far as long distance source-receptor transitions are concerned, because they are mostly realised via higher transport paths.
  • •The third (vertical) dimension is not negligible for the task of a complete source attribution, as a considerable amount of elevated emissions, preferably out of 300±100 m elevation, reaches the receptor box which is only 50 m in depth. Hence, downward mixing of elevated and far distance sources is an important process and driven by the diurnal course of turbulence and low level jets within the PBL
  • •On the short time scale (few days), the source attribution is not independent from the regarded time scale (simulation time) due to the neglecting of older emissions released before the beginning of the simulation.
  相似文献   

20.
Chen XM  Shen QR  Pan GX  Liu ZP 《Chemosphere》2003,50(6):703-706
The characteristics of nitrate horizontal transport in a major paddy soil, Wu Shan soil in the Tai Lake region, were studied. The concentration of nitrate during horizontal movement decreased with the increasing in distance from the tracer source, the change following a logarithmic function. The concentration of the nitrate was strongly correlated with the soil moisture content, as an exponential function. The horizontal transport velocity of nitrate was significantly correlated with the distance of the tracer source as power function. Therefore, the velocity of nitrate horizontal transport was controlled by the concentration gradient of nitrate, and soil water potential gradient from beginning to the 20 cm mark in the horizontal column. However, the velocity of nitrate horizontal was stable beyond 20 cm, where it was controlled by soil matric potential.  相似文献   