首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lee CC  Chen HL  Su HJ  Guo YL  Liao PC 《Chemosphere》2005,59(10):1465-1474
The aim of this study was to evaluate the PCDD/Fs patterns in ambient air based on data information emitted from incinerator generated from ambient air measurements and those in serum. Four circular zones, namely A, B, C, and D, were identified based on simulated ambient annual average PCDD/Fs concentrations, from a selected municipal waste incinerator. Sixteen ambient samples were taken from the 4 circular zones across 4-seasons. Eighty-nine volunteers were recruited according to the demographic distribution within each zone. PCDD/Fs profiles were documented both for air and serum samples collected. Comparing to the congener patterns from ambient air and serum samples, we found that OCDD, OCDF, 1,2,3,4,6,7,8-HpCDD, and 1,2,3,4,6,7,8-HpCDF were the predominant groups among 17 congeners from both the ambient air and serum sample. And, factor analysis showed the distribution patterns of PCDD/Fs from ambient air and serum samples are almost identical across different zones, except for congener patterns of serum samples from residents in zone C. In addition, the average PCDD/Fs level significantly reduced for about 10 folds than those of the other three seasons when the incinerator was shut down in one of sampling periods. We might conclude that ambient air exposure was the most important contributor to PCDD/Fs levels in ambient air but not the single in serum. Therefore, another or more powerful source, such as occupational exposure, dietary intake or the consumption of local food, should be further investigated at the same time.  相似文献   

2.
Shih TS  Chen HL  Wu YL  Lin YC  Lee CC 《Chemosphere》2006,64(9):1444-1449
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) have been found in ambient air around municipal waste incinerators (MWIs), and elevated serum levels in incinerator workers have also been observed in some studies. However, few studies have focused on temporary employees who work intermittently through the annual maintenance and clean-up around different incinerators. The present study aimed to assess the change in serum PCDD/F levels of temporary employees between the beginning of periodic incinerator maintenance and one month the work was completed. Thirty-five volunteer workers, most of them transient and temporary maintenance staff, were recruited from a contractor that provided annual maintenance for four incinerators in this study. Information about each participant was obtained by questionnaire at the beginning of annual maintenance. The questionnaire asked for work history, health status, and diet information. As measured by the PCDD/F levels in blood, a significant increase was observed in workers after a month of maintenance work. The increase was greater in workers who had never done this type of maintenance than in those with previous experience, especially for 2,3,4,6,7,8-HxCDF levels. The data also showed that the laborers and employers need to pay more attention to occupational health issues even for short-term incinerator maintenance workers.  相似文献   

3.
Sampling and analysis of ambient dioxins in northern Taiwan   总被引:2,自引:0,他引:2  
Chang MB  Weng YM  Lee TY  Chen YW  Chang SH  Chi KH 《Chemosphere》2003,51(10):1103-1110
In this study, ambient air samples were taken concurrently in the vicinity area of a large-scale municipal waste incinerator (MWI) and the background area for measuring polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) concentrations from November 1999 through July 2000 in northern Taiwan. The results obtained from eighteen ambient air samples indicate that the mean PCDD/F concentration of seventeen 2,3,7,8-substituted congeners in wintertime (188–348 fg-I-TEQ/m3) is significantly higher than that measured in summertime (56–166 fg-I-TEQ/m3). In addition, the seasonal PCDD/F concentrations are compared with the ambient air quality data including CO, NO2, PM10 and TSP sampled from Taipei area to gain better insights. It indicates that the variation of ambient air PCDD/F concentrations is closely correlated with that of PM10 concentrations. Besides, the results indicate that the I-TEQ concentration of ambient air in sampling site B (directly downwind of the MWI) is of the highest while the sampling site A (upwind of MWI) is of the lowest among all sampling sites. This implies that existing MWI can be a significant emitter of PCDD/Fs in this area. Furthermore, the patterns of the PCDD/F congener distribution at all sampling sites (including the background site in Taoyuan) are quite similar. OCDD concentration is of the highest among seventeen PCDD/F congeners investigated and accounts for about 35% of the total concentration. As for the I-TEQ concentrations, 2,3,4,7,8-PeCDF is the most significant contributor, generally being responsible for 30–45% of the total I-TEQ values depending on the sampling sites and seasons.  相似文献   

4.
To assess the influence of a new hazardous waste incinerator (HWI) on public health, a preoperational monitoring program was established during the period of construction. In this study, the levels of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) accumulated in adipose tissue of 15 autopsied subjects living in the area under potential impact of the HWI were determined after approximately 3 years of regular operations in the facility. The non-ortho PCBs 77, 126 and 169 were also determined. PCDD/F concentrations ranged between 1.5 and 41 pg WHO-TEQ/g fat (2.4 and 72 WHO-TEQ/g fat, respectively, including PCBs), with a mean value of 11 pg WHO-TEQ/g fat and a median value of 7.4 pg WHO-TEQ/g fat (22 and 13 WHO-TEQ/g fat, respectively, including PCBs). In the baseline study, the mean level of PCDD/Fs was 36 pg WHO-TEQ/g fat (61 pg WHO-TEQ/g fat, including non-ortho PCBs 77, 126 and 169), which means a reduction of 70% (64% including PCBs). This notable reduction is in accordance with the important decrease observed in recent years in PCDD/F intake through the diet. The current concentrations of PCDD/Fs in human adipose tissue, as well as recent data on PCDD/F levels in plasma and breast milk of subjects living in the vicinity of the same HWI, indicate that there is not any additional significant exposure to PCDD/Fs for this population.  相似文献   

5.
Chen HL  Shih TS  Huang PC  Hsieh CY  Lee CC 《Chemosphere》2006,64(4):666-671
This study aimed to evaluate serum polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) levels in electric-arc-furnace workers according to their corresponding occupational exposure. In addition, the ambient PCDD/Fs of the work environment were measured to provide additional support for the exposure and accumulation inside the electric arc furnace. The ambient PCDD/F concentrations inside the electric arc furnace were 1.557-1.917 pg-TEQ/Nm(3), 5-24 folds higher than those outside (0.080-0.385 pg-TEQ/N m(3)). In addition, higher average serum levels were measured in the workers with high occupational dioxin exposure (24.0 pg WHO-TEQ/g lipid) than in those with lower occupational dioxin exposure (13.8 pg WHO-TEQ/g lipid). Higher PCDFs/PCDDs ratios were found in serum samples from high-exposure groups than in low-exposure groups. The higher ratio of PCDFs/PCDDs was also found in ambient samples consistent with other metallurgical processes reported previously. Our results suggest that PCDD/Fs exposure exits in the smelting process of electric arc furnace, and the occupational hygiene should be taken more seriously concern in that workplace.  相似文献   

6.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in plasma samples of 20 nonoccupationally exposed subjects living in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (Catalonia, Spain). The mean PCDD/F value was 27.0 pg I-TEQ/g lipid with a range from 14.8 to 48.9 pg I-TEQ/g lipid. All samples showed higher PCDD than PCDF levels. Although PCDD/F concentrations were higher in women (27.7 pg I-TEQ/g lipid) than in men (25.2 pg I-TEQ/g lipid), the difference was not statistically significant. While a significant correlation (r = 0.565, p < 0.01) between the age of the subjects and the levels of PCDD/F in plasma could be observed, no significant differences were found in relation to the specific residential area. The plasma concentrations of PCDD/F obtained in the current study are discussed and compared with the results of similar investigations reported in the last two years.  相似文献   

7.
Choi MP  Ho SK  So BK  Cai Z  Lau AK  Wong MH 《Chemosphere》2008,71(2):211-218
PCDD/F and dioxin-like PCB were measured in 142 air samples of Hong Kong. The annual average PCDD/F and dioxin-like PCB concentrations obtained for Hong Kong air at Tap Mun (PCDD/F: 1724+/-1984; dioxin-like PCB: 1572+/-1170 fg m(-3)), Yuen Long (PCDD/F: 2927+/-2695; dioxin-like PCB: 4331+/-1962 fg m(-3)) and Tsuen Wan (PCDD/F: 1875+/-1502; dioxin-like PCB: 2972+/-1510 fg m(-3)) from January 2004 to March 2005 were comparable to other urban centers around the world and were within the Japanese and USA ambient air quality guidelines. A clear seasonal pattern was observed for PCDD/F, generally with a 50-60 times higher air concentration in winter when background northerly wind was weaker and land-sea breeze prevailed, resulting in regional transport; and a lower concentration in summer, due to the inflow of clean oceanic southeasterly wind from the South China Sea. A higher WHO-TEQ value of dioxin-like PCB (mainly attributed to the relatively higher WHO-TEQ value of PCB 126) in Yuen Long during winter, compared with other months, could also be related to the regional transport by the winter monsoon wind and the low mixing height in winter. Spatially, air concentrations of PCDD/F and dioxin-like PCB demonstrated a west-to-east gradient (with Yuen Long>Tsuen Wan>Tap Mun). It is suggested that PCDD/F and dioxin-like PCB were transported into the western airshed of Hong Kong from the Pearl River Delta by land-sea breeze circulation and confined to the northwestern part, due to the blocking effect of the northwestern airshed in Hong Kong.  相似文献   

8.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

9.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

10.
Floret N  Lucot E  Badot PM  Mauny F  Viel JF 《Chemosphere》2007,68(8):1419-1426
Since 1971, a municipal solid waste incinerator (MSWI) with high dioxin emission levels has been in operation in Besan?on, France. We recently found a 2.3-fold risk of non-Hodgkin's lymphoma in the highest exposure zone using a Gaussian-type dispersion model as a proxy for dioxin exposure. However, the sources of PCDD/Fs in this area are a matter of controversy. The aim of this survey was therefore to examine the nature of the PCDD/F soil contamination in the surroundings of the MSWI to characterize whether more than one potential emission source could explain the presence of the PCDD/Fs. PCDD/F congener profiles were determined in 75 soil samples collected in the vicinity of the MSWI. They were compared according to the most environmentally impacted zones and to various spatial contrasts. PCDD/F concentrations ranged from 0.25 to 28.06 pg WHO-TEQ g(-1). Two different clustering algorithms identified the same main cluster (consisting of 73 samples). The remaining two soil samples composed either one, or two clusters. All clusters showed similar congener profiles. Moreover, no contrast was observed for congener distributions between complex and simple topographies, inside and outside the city boundary, the two most and the two least exposed areas, reflecting a common fingerprint. Congener profiles indicate that the area under influence of the MSWI is not subject to other point sources of PCDD/Fs. Since, the most polluting combustion chambers were recently shut down and replaced by a new one with up-to-date pollution control, slowly decreasing dioxin concentrations in the soils are to be expected.  相似文献   

11.
Kim BH  Lee SJ  Mun SJ  Chang YS 《Chemosphere》2005,58(11):1589-1599
Many studies have been conducted that monitor and trace the sources of polychlorinated dibenzo-p-dioxin/furans (PCDD/Fs) by comparing congener patterns of environmental samples with those of possible sources. In this study, we measured PCDD/F concentrations and compared congener patterns of samples of various media found in and around an industrial waste incinerator in Korea, including stack gas, fly ash, bottom ash, ambient air, soil, pine needle, and human blood. We obtained reliable data on the relationship between the PCDD/F distributions in these sources and the environment, and thus found indicators with which to assess the impact of such sources on the surrounding environment. In addition, the difference between the levels of PCDD/Fs in the blood of short-term workers and long-term workers demonstrates that these workers are exposed to the compounds produced by the indicator.  相似文献   

12.
Huang H  Buekens A 《Chemosphere》2001,44(6):1505-1510
A kinetic model is developed for de novo synthesis of PCDD/F from carbon in incinerator fly ash. The main mechanistic steps considered in the model are carbon gasification, PCDD/F formation, desorption and degradation. Rate equations are derived which can relate PCDD/F formation with process variables including carbon concentration of fly ash, partial pressure of oxygen, reaction temperature and time. The kinetic model has been verified using laboratory de novo synthesis data reported in the literature. When the model is applied to industrial incinerator conditions, PCDD/F formation levels of 0.1-0.5 microg/N m3 in the gas phase and 0.1-1.2 microg/g in the solid phase are calculated, and both are in good agreement with incinerator measurements.  相似文献   

13.
As part of a longitudinal cohort study, now in its second decade, we determined PCDDs/Fs dl-PCBs and PBDEs in serum of adolescents with known perinatal PCDD/F exposure. Of the original cohort, 33 adolescents aged 14-19 years, who had been studied previously during their neonatal (n=60), toddler and pre-pubertal period (n=41) agreed to participate in the current follow-up. PCDD/F-, dl-PCB- and PBDE congeners were measured using GC/MS. Current serum levels of PCDD/Fs determined in our cohort were relatively low (mean of 2.2pg/g) compared to the perinatal exposure. No correlation between perinatal exposure and current serum PCDD/F was found. Planar PCB TEQ levels were 2.2pg/g. Current summation operatorPBDE levels were 8.7ng/g lipid. There was one outlier with a summation operatorPBDE of 74ng/g lipid. The presence of this high value indicates that the exposure pathway is different from PCDD/F and PCB, most likely by dust and food contaminated with dust. Concluding we can say that current PCDD/F levels are quite low compared to the perinatal PCDD/F exposure of the cohort. PBDE levels however are relatively high compared to other European countries, more research on possible health effects of these levels, especially for subjects with outlier concentrations, should be performed.  相似文献   

14.
H.Y. Tong  F.W. Karasek 《Chemosphere》1986,15(9-12):1219-1224
Flyash samples were collected from the electrostatic precipitators of seven municipal refuse incinerators of four different countries. Analytical results of PCDD and PCDF in these samples shows a very similar iosmer distribution pattern for all PCDD/PCDF although concentrations of PCDD and PCDF vary. These results imply that PCDD/PCDF were formed through the same mechanism in those incinerators regardless of garbage composition or incinerator design.  相似文献   

15.
Wang SL  Lin CY  Guo YL  Lin LY  Chou WL  Chang LW 《Chemosphere》2004,54(10):1459-1473
Polychlorinated dibenzo-p-dioxins, dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) are recognized environmental endocrine disruptors, which are environmentally persistent and may bio-accumulate in human bodies. Pregnant and nursing women may pass these pollutants to their babies both trans-placentally and lactationally. We measured and examined correlations of the levels of PCDD/Fs and PCBs in perinatal venous serum, placenta, umbilical-cord serum (representing prenatal exposure), and breast milk (postnatal exposure). Subjects included pregnant women without clinical complication between the ages of 25 and 35, who delivered their babies during 2000.12.01 and 2001.11.30 in central Taiwan. A total of 20 participants were randomly selected from those provided the four biological specimens for analysis of 17 PCDD/Fs, and 12 dioxin-like PCBs and six indicator PCBs using high-resolution gas chromatography/high-resolution mass spectrometry. Higher PCDD/F levels were found in placenta (10.3 TEq-pg/g lipid) and venous serum (9.1 TEq-pg/g lipid) compared to those in breast milk (7.6 TEq-pg/g lipid). Pearson and Spearman correlation analyses showed well association of PCDD/F and PCB levels between different specimens. The total dioxin/PCB level in milk, venous and cord serum can be well predicted by that in placenta through regression functions. This first study of multi-specimen correlation further established rather consistent ratios of these chemical concentrations in various specimens relative to those in venous serum.  相似文献   

16.
Wu WZ  Schramm KW  Xu Y  Kettrup A 《Chemosphere》2001,43(4-7):633-641
The present study monitored fish from sites contaminated for many years, and the data reflected the results of actual, long-term environmental exposure. The sum concentrations and TEQs of PCDD/F in the muscle of common carp (Cyprinus carpio (linnaeus)) and big head (Aristichthys nobilis) from the different site of a heavily polluted lake in China are decreased with decrease of PCDD/F concentration in sediment and water. Concentration in fish can be highly variable, but the concentration is comparable in muscle between different species of fish if the concentrations are normalized by lipid content. PCDD/F accumulate in certain tissues with the highest proportions found in the liver of fish. The concentrations and TEQs in livers were also decreased with concentrations of sediments and water. The concentrations of PCDD/F in muscle are significantly correlated with those in liver. BCFs of 2,3,7,8-substituted PCDD/F calculated directly from water were consistent with that calculated indirectly from sediment. PCDD/F concentrations in sediment are much higher than that in water, therefore the measurement is much easier and the results are more accurate. Estimated BCFs for superhydrophobic chemicals derived from sediment may also serve as acceptable surrogates for "true" bioaccumulation potential.  相似文献   

17.
Air pollution control devices (APCDs) are not compulsory for medical waste incinerators (MWIs) in developing countries. In South Africa, combustion gases are usually vented directly to the atmosphere at temperatures greater than the formation temperature of dioxin. The possibility of dioxin formation outside the incinerator stack has been hypothesized. A plume model has been developed and tested in the wind tunnel with a scale model of an incinerator stack. The plume temperature and trajectory predictions of the plume model were verified within a +/- 3% experimental accuracy. Using South African data, the plume model predicts that the residence time of gases in the temperature range of 150-450 degrees C in a plume is 1.3 sec on average for 5% of a year (18 days) at meteorological conditions resulting in wind speeds of less than 1 m/sec. Two published dioxin formation models were used to assess the probability of dioxin formation in the plume. The formation models predict that the average polychlorinated dibenzodioxins/furans (PCDD/Fs) formed in the plume will exceed the stack emission regulations in South Africa of 0.2 ng/Nm3 toxic equivalent quotient (TEQ) by between 2 and 40 times. The calculated concentrations do not include additional gaseous PCDD/F compounds that may be formed at high-temperature post-combustion zones through pyrosynthesis mechanisms.  相似文献   

18.
In this study, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) in breast milk from mothers living in the vicinity of a new hazardous waste incinerator (HWI) were determined. Monitoring was performed after three years of regular operations in the facility and the present results were compared with baseline concentrations obtained in a pre-operational program. PCDD/PCDF levels were determined by HRGC/HRMS in 15 samples. In the present study, PCDD/PCDF concentrations ranged from 4.9 to 39.9 pg I-TEQ/g fat (5.1-46.8 pg WHO-TEQ/g fat), with a median value of 7.7 pg I-TEQ/g fat (9.1 pg WHO-TEQ/g fat). In the baseline survey, PCDD/PCDF concentrations ranged between 5.9 and 17.1 pg I-TEQ/g fat, with a median value of 11.7 pg I-TEQ/g fat. In relation to this, a percentage of reduction of 34.2% was noted. This decrease is in agreement with the relevant reduction found in the dietary intake of PCDD/PCDFs between both surveys. The results of the present study, as well as other recent environmental and biological data, indicate that living in the vicinity of this HWI should not mean additional health risks due to PCDD/PCDFs for the general population.  相似文献   

19.
Concentrations of 17 toxic 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) have been determined in pooled samples of breast milk from 15 mothers living in two residential areas (Tarragona downtown and an industrial area) in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (southern Catalonia, Spain). PCDD/Fs in human milk samples ranged between 5.9 and 17.1 pg I-TEQ/g fat (162-498 pg I-TEQ/l), with a mean value of 11.8 pg I-TEQ/g fat (310.8 pg I-TEQ/l). The percentages of fat ranged between 1.53 and 3.52. Although PCDD/F levels in milk from mothers living in the industrial area were found to be slightly higher than those observed in women living Tarragona downtown, most differences did not reach the level of statistical significance. In general terms, PCDD/F concentrations in human milk (pooled) samples of mothers living in the area of Tarragona are similar or lower than those previously reported for most industrialized countries.  相似文献   

20.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号