首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objectives of this study were to examine the application of the divalent cation bridging theory (DCBT) to improve settling, dewatering, and effluent quality in pilot-scale reactors and a full-scale system treating an industrial wastewater. This was accomplished by lowering the monovalent-to-divalent (M/D) cation ratio by direct divalent cation addition. Research has shown that the M/D ratio is a potential indicator for settling and dewatering problems at wastewater treatment plants, and M/D ratios above 2 have been associated with poor settling, dewatering, and effluent quality. The M/D ratio of the wastewater in this study ranged from 6 to 20. The cations studied were calcium and magnesium. Results showed that the addition of calcium improved floc properties compared to control reactors with no calcium addition. The reductions in sludge volume index, effluent chemical oxygen demand (COD), and effluent total suspended solids (TSS) were approximately 35, 34, and 55%, respectively, when the M/D ratio was decreased to approximately 2:1. In addition, the cake solids from a belt filter press simulator increased by 72% and the optimum polymer dose required for conditioning was reduced by 70% in the reactor fed the highest calcium concentration when compared to control reactors with no calcium addition. The addition of calcium also decreased the negative effect of high filamentous organism numbers. In general, the addition of magnesium (Mg2+) had similar effects on effluent quality and dewatering properties, although some differences were measured. A full-scale test using calcium addition was performed. Measurements of effluent quality and floc properties were performed before, during, and after the calcium (Ca2+) addition period. The average M/D ratio during these periods was 6.2, 4.6, and 14.0, respectively. The addition of Ca2+ decreased the effluent five-day biochemical oxygen demand, effluent TSS, and effluent COD. The increased Ca2+ concentration also improved dewatering measured by a decrease in specific resistance to filtration and capillary suction time. Overall, the addition of divalent cations to the pilot- and full-scale activated sludge systems improved floc properties and the data fit well with the DCBT.  相似文献   

2.
Batt AL  Kim S  Aga DS 《Chemosphere》2007,68(3):428-435
The occurrence of ciprofloxacin, sulfamethoxazole, tetracycline, and trimethoprim antibiotics in four full-scale wastewater treatment plants (WWTPs) that differ in design and operating conditions was determined. The WWTPs chosen utilized a variety of secondary removal processes, such as a two stage activated sludge process with a nitrification tank, extended aeration, rotating biological contactors, and pure oxygen activated sludge. Several of the WWTPs also employed an advanced treatment process, such as chlorination and UV radiation disinfection. The detected concentrations (microg/l) ranged from 0.20 to 1.4 for ciprofloxacin, 0.21 to 2.8 for sulfamethoxazole, 0.061 to 1.1 for tetracycline, and 0.21 to 7.9 for trimethoprim. The overall percent difference in the concentrations of the antibiotics in the effluent and influent of these antibiotics differed between plants and ranged from 33% to 97%. Based on these four full-scale WWTPs evaluated, the apparent removal of organic micropollutants in wastewater is dependent on a combination of biological and physico-chemical treatment processes and operating conditions of the treatment system.  相似文献   

3.
Lai CL  Lin SH 《Chemosphere》2004,54(3):235-242
Treatment of copper chemical mechanical polishing (CMP) wastewater from a semiconductor plant by electrocoagulation is investigated. The CMP wastewater was characterized by high suspended solids (SS) content, high turbidity (NTU), chemical oxygen demand (COD) concentration up to 500 mgl(-1) and copper concentration up to 100 mgl(-1). In the present study, electrocoagulation was employed to treat the CMP wastewater with an attempt to simultaneously lower its turbidity, copper and COD concentrations. The test results indicated that electrocoagulation with Al/Fe electrode pair was very efficient and able to achieve 99% copper ion and 96.5% turbidity removal in less than 30 min. The COD removal obtained in the treatment was better than 85%, with an effluent COD below 100 mgl(-1). The effluent wastewater was very clear and its quality exceeded the direct discharge standard. In addition, sludge settling velocities after electrocoagulation were measured and the data were employed to verify the empirical sludge settling velocity models. Finally, the sludge settling characteristic data were also utilized to establish the relation between the solids flux (G) and the initial solids concentration.  相似文献   

4.
生物铁法是一种新型的强化活性污泥法,处理高浓度、难生物降解维生素B1生产废水具有很大的优势.当进水COD浓度维持在8000 mg/L时,COD的去除率可达94%以上,比普通活性污泥法高出9.7%.生物铁法污泥絮凝沉淀效果好,能保证系统有较高浓度的回流污泥,从而使曝气池的污泥浓度得到提高,COD的去除率也会相应地提高.  相似文献   

5.
生物铁法去除维生素B1生产废水中COD的试验研究   总被引:5,自引:0,他引:5  
生物铁法是一种新型的强化活性污泥法,处理高浓度、难生物降解维生素B1生产废水具有很大的优势。当进水COD浓度维持在8000mg/L时,COD的去除率可达94%以上,比普通活性污泥法高出9.7%。生物铁法污泥絮凝沉淀效果好,能保证系统有较高浓度的回流污泥,从而使曝气池的污泥浓度得到提高,COD的去除率也会相应地提高。  相似文献   

6.
The objective of this study was to investigate the application of the divalent cation bridging theory (DCBT) as a tool in the chemical selection process at an activated sludge plant to improve settling, dewatering, and effluent quality. According to the DCBT, to achieve improvements, the goal of chemical selection should be to reduce the ratio of monovalent-to-divalent (M/D) cations. A study was conducted to determine the effect of using magnesium hydroxide [Mg(OH)2] as an alternative to sodium hydroxide (NaOH) at a full-scale industrial wastewater treatment plant. Floc properties and treatment plant performance were measured for approximately one year during two periods of NaOH addition and Mg(OH)2 addition. A cost analysis of plant operation during NaOH and Mg(OH)2 use was also performed. During NaOH addition, the M/D ratio was 48, while, during Mg(OH)2 addition, this ratio was reduced to an average of approximately 0.1. During the Mg(OH)2 addition period, the sludge volume index, effluent total suspended solids, and effluent chemical oxygen demand were reduced by approximately 63, 31, and 50%, respectively, compared to the NaOH addition period. The alum and polymer dose used for clarification was reduced by approximately 50 and 60%, respectively, during Mg(OH)2 addition. The dewatering properties of the activated sludge improved dewatering as measured by decreased capillary suction time and specific resistance to filtration (SRF), along with an increase in cake solids from the SRF test. This corresponded to a reduction in the volume of solids thickened by centrifuges at the treatment plant, which reduced the disposal costs of solids. Considering the costs for chemicals and solids disposal, the annual cost of using Mg(OH)2 was approximately 30,000 dollars to 115,000 dollars less than using NaOH, depending on the pricing of NaOH. The results of this study confirm that the DCBT is a useful tool for assessing chemical-addition strategies and their potential effect on activated sludge performance.  相似文献   

7.
Occurrence and fate of heavy metals in the wastewater treatment process   总被引:19,自引:0,他引:19  
The occurrence and the fate of heavy metals (Cd, Pb, Mn, Cu, Zn, Fe and Ni) during the wastewater treatment process were investigated in the wastewater treatment plant (WTP) of the city of Thessaloniki, northern Greece, operating in the activated sludge mode. For this purpose, wastewater and sludge samples were collected from six different points of the plant, namely, the influent (raw wastewater, RW), the effluent of the primary sedimentation tank (primary sedimentation effluent, PSE), the effluent of the secondary sedimentation tank (secondary sedimentation effluent, SSE), sludge from the primary sedimentation tank (primary sludge, PS), activated sludge from the recirculation stream (activated sludge, AS), and the digested/dewatered sludge (final sludge, FS).

The distribution of metals between the aqueous and the solid phase of wastewater was investigated. Good exponential correlation was found between the metal partition coefficient, logKp, and the suspended solids concentration. The mass balance of heavy metals in the primary, secondary and the whole treatment process showed good closures for all metal species. The relative distribution of individual heavy metals in the treated effluent and the sludge streams indicated that Mn and Cu are primarily (>70%) accumulated in the sludge, while 47–63% of Cd, Cr, Pb, Fe, Ni and Zn remain in the treated effluent.  相似文献   


8.
The molecular-weight distribution (MWD) of wastewater dissolved-organic carbon (DOC) was determined in samples from seven full-scale wastewater-treatment plants (WWTPs) that use different biological treatments (air activated sludge [air-AS], pure-oxygen AS [O2-AS], and trickling filters). The research objective was to determine how different biological treatments influenced the MWD of wastewater DOC. Primary sedimentation effluent DOC from most of the WWTPs exhibited a skewed distribution toward the low-molecular-weight fraction (MWF) (40 to 50%, < 0.5 K Daltons [KDa]). The Air-AS effluent DOC exhibited a centrally clustered distribution, with the majority of DOC in the intermediate MWF (0.5 to 3 KDa). The O2-AS effluent DOC exhibited a skewed distribution toward the high MWF (> 3 KDa). The removal of DOC by air- and O2-AS bacteria followed trends predicted by a macromolecule degradation model. Trickling-filter effluent DOC exhibited a skewed distribution toward the high MWF (50% DOC, > 3 KDa).  相似文献   

9.
Perfluorinated compounds (PFCs) are fully fluorinated organic compounds, which have been used in many industrial processes and have been detected in wastewater and sludge from municipal wastewater treatment plants (WWTPs) around the world. This study focused on the occurrences of PFCs and PFCs mass flows in the industrial wastewater treatment plants, which reported to be the important sources of PFCs. Surveys were conducted in central wastewater treatment plant in two industrial zones in Thailand. Samples were collected from influent, aeration tank, secondary clarifier effluent, effluent and sludge. The major purpose of this field study was to identify PFCs occurrences and mass flow during industrial WWTP. Solid-phase extraction (SPE) coupled with HPLC-ESI-MS/MS were used for the analysis. Total 10 PFCs including perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluoropropanoic acid (PFPA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorohexane sulfonate (PFHxS), perfluoronanoic acid (PFNA), perfluordecanoic acid (PFDA), perfluoroundecanoic acid (PFUnA), and perfluorododecanoic acid (PFDoA) were measured to identify their occurrences. PFCs were detected in both liquid and solid phase in most samples. The exceptionally high level of PFCs was detected in the treatment plant of IZ1 and IZ2 ranging between 662-847 ng L−1 and 674-1383 ng L−1, respectively, which greater than PFCs found in most domestic wastewater. Due to PFCs non-biodegradable property, both WWTPs were found ineffective in removing PFCs using activated sludge processes. Bio-accumulation in sludge could be the major removal mechanism of PFCs in the process. The increasing amount of PFCs after activated sludge processes were identified which could be due to the degradation of PFCs precursors. PFCs concentration found in the effluent were very high comparing to those in river water of the area. Industrial activity could be the one of major sources of PFCs contamination in the water environment.  相似文献   

10.
Unlike wastewater, pulp and paper mill effluents are generally severely deficient in bioavailable nitrogen and phosphorus. The influence of nitrogen and phosphorus limitations on steady-state or typical pulp and paper mill activated sludge floc properties and performance was studied using a bioreactor-fed synthetic raw mill effluent and seeded with mill activated sludge. Limitation of either nitrogen or phosphorus decreased growth, five-day biochemical oxygen demand, and suspended solids removal. Nitrogen limitation greatly enhanced activated sludge floc poly-beta3-hydroxybutyrate (PHB), but not carbohydrate or extracellular polymeric substances (EPS). In contrast, phosphorus limitation increased total floc carbohydrate and EPS, but not PHB. The flocs showed little ability to store either nitrogen or phosphorus. Nitrogen limitation, but not phosphorus limitation, produced much more negative net floc surface charge, increasing fines, while phosphorus limitation, but not nitrogen limitation, increased the floc bound water content and surface hydrophobicity and decreased fines.  相似文献   

11.
The occurrence and estimated concentration of twenty illicit and therapeutic pharmaceuticals and metabolites in surface waters influenced by wastewater treatment plant (WWTP) discharge and in wastewater effluents in Nebraska were determined using Polar Organic Chemical Integrative Samplers (POCIS). Samplers were installed in rivers upstream and downstream of treated WWTP discharge at four sites and in a discharge canal at a fifth location. Based on differences in estimated concentrations determined from pharmaceuticals recovered from POCIS, WWTP effluent was found to be a significant source of pharmaceutical loading to the receiving waters. Effluents from WWTPs with trickling filters or trickling filters in parallel with activated sludge resulted in the highest observed in-stream pharmaceutical concentrations. Azithromycin, caffeine, 1,7-dimethylzanthine, carbamazepine, cotinine, DEET, diphenhydramine, and sulfamethazine were detected at all locations. Methamphetamine, an illicit pharmaceutical, was detected at all but one of the sampling locations, representing only the second report of methamphetamine detected in WWTP effluent and in streams impacted by WWTP effluent.  相似文献   

12.
Heavy metal extractable forms in sludge from wastewater treatment plants   总被引:17,自引:0,他引:17  
The analysis of heavy metals is a very important task to assess the potential environmental and health risk associated with the sludge coming from wastewater treatment plants (WWTPs). However, it is widely accepted that the determination of total elements does not give an accurate estimation of the potential environmental impact. So, it is necessary to apply sequential extraction techniques to obtain a suitable information about their bioavailability or toxicity. In this paper, a sequential extraction scheme according to the BCR's guidelines was applied to sludge samples collected from each sludge treatment step of five municipal activated sludge plants. Al. Cd, Co, Cu, Cr, Fe, Mn, Hg, Mo, Ni, Pb, Ti and Zn were determined in the sludge extracts by inductively coupled plasma atomic emission spectrometry. In relation to current international legislation for the use of sludge for agricultural purposes none of metal concentrations exceeded maximum permitted levels. In most of the metal elements under considerations, results showed a clear rise along the sludge treatment in the proportion of two less-available fractions (oxidizable metal and residual metal).  相似文献   

13.
Co-treatment of acid mine drainage (AMD) with municipal wastewater (MWW) using the activated sludge process is a novel treatment technology offering potential savings over alternative systems in materials, proprietary chemicals and energy inputs. The impacts of AMD on laboratory-scale activated sludge units (plug-flow and sequencing batch reactors) treating synthetic MWW were investigated. Synthetic AMD containing Al, Cu, Fe, Mn, Pb, Zn and SO4 at a range of concentrations and pH values was formulated to simulate three possible co-treatment processes, i.e., (1) adding raw AMD to the activated sludge aeration tank, (2) pre-treating AMD prior to adding to the aeration tank by mixing with digested sludge and (3) pre-treating AMD by mixing with screened MWW. Continuous AMD loading to the activated sludge reactors during co-treatment did not cause a significant decrease in chemical oxygen demand (COD), 5-day biochemical oxygen demand, or total organic carbon removal; average COD removal rates ranged from 87–93 %. Enhanced phosphate removal was observed in reactors loaded with Fe- and Al-rich AMD, with final effluent TP concentrations <2 mg/L. Removal rates for dissolved Al, Cu, Fe and Pb were 52–84 %, 47–61 %, 74–86 % and 100 %, respectively, in both systems. Manganese and Zn removal were strongly linked to acidity; removal from net-acidic AMD was <10 % for both metals, whereas removal from circum-neutral AMD averaged 93–95 % for Mn and 58–90 % for Zn. Pre-mixing with screened MWW was the best process option in terms of AMD neutralization and metal removal. However, significant MWW alkalinity was consumed, suggesting an alkali supplement may be necessary.  相似文献   

14.
Wastewater treatment plants (WWTPs) are a potential of source of polycyclic musks in the aquatic environment. In this study, contamination profiles and mass flow of polycyclic musks, 1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta[gamma]-2-benzopyran (HHCB), 7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene (AHTN), and HHCB-lactone (oxidation product of HHCB), in two WWTPs, one located in Kentucky (Plant A, rural area) and the other in Georgia (Plant B, urban), USA, were determined. HHCB, AHTN and HHCB-lactone were detected in the influent, effluent, and sludge samples analyzed. The concentrations in wastewater samples varied widely, from 10 to 7,030 ng/l, 13 to 5,400 ng/l, and 66 to 790 ng/l, for HHCB, AHTN, and HHCB-lactone, respectively. Sludge samples contained HHCB at <0.02-36 microg/g dry weight, AHTN at <0.02-7.2 microg/g dry weight, and HHCB-lactone at <0.05-17 microg/g dry weight. Based on the daily flow rates and mean concentrations of polycyclic musks, the estimated discharge of total polycyclic musks to the rivers was 21 g/day from Plant A and 31 g/day from Plant B. Mass balance analysis suggested that only 30% of HHCB and AHTN entering the plants was accounted for in the effluent and the sludge. Removal efficiencies of HHCB and AHTN in the two WWTPs ranged from 72% to 98%. In contrast, HHCB-lactone concentrations increased following the treatment. Concentrations of polycyclic musks in sludge were on the order of several parts per million. Incineration of sludge at one plant reduced the concentration of polycyclic musks.  相似文献   

15.
Bioleaching processes have been demonstrated to be effective technologies in removing heavy metals from wastewater sludge, but long hydraulic retention times are typically required to operate these bioprocesses. A hybrid process (coupling biological and chemical processes) has been explored in laboratory pilot-scale experiments for heavy metals (cadmium [Cd], copper [Cu], chromium [Cr], and zinc [Zn]) removal from three types of sludge (primary sludge, secondary activated sludge, and a mixture of primary and secondary sludge). The hybrid process consisted of producing a concentrate ferric ion solution followed by chemical treatment of sludges. Ferric iron solution was produced biologically via oxidation of ferrous iron by A. ferrooxidans in a continuous-flow stirred tank (5.2 L) reactor (CSTR). Wastewater sludge filtrate (WSF) containing nutrients (phosphorus and nitrogen) has been used as culture media to support the growth and activity of indigenous iron-oxidizing bacteria. Results showed that total organic carbon (TOC) concentrations of the culture media in excess of 235 mg/L were found to be inhibitory to bacterial growth. The oxidation rate increased as ferrous iron concentrations ranged from 10 to 40 g Fe2+/L. The percentage of ferrous iron (Fe2+) oxidized to ferric iron (Fe3+) increased as the hydraulic retention time (HRT) increased from 12 to 48 h. Successful and complete Fe2+ oxidation was recorded at a HRT of 48 h using 10 g Fe2+/L. Subsequently, ferric ion solution produced by A. ferrooxidans in sludge filtrate was used to solubilize heavy metals contained in wastewater sludge. The best solubilization was obtained with a mixture of primary and secondary sludge, demonstrating a removal efficiency of 63, 71, 49, and 80% for Cd, Cu, Cr, and Zn, respectively.  相似文献   

16.
Real-time control of aeration tank operation is key to high-efficiency pollutant removal and energy savings. One of the aims of this study was to examine the potential for using redox potential (oxidation-reduction potential [ORP]) to indicate wastewater quality online in aeration tanks treating medium (chemical oxygen demand [COD] of 70 to 150 mg/L) and low (COD of 15 to 30 mg/L) pollutant-concentration wastewaters. The field-scale data provide a good relationship between ORP values and nutrient removal along the length of the aeration tanks. The ORP values increased dramatically as organic matter was removed along the aeration tanks, indicating the improvement of the bulk liquor redox status. Dissolved oxygen higher than 1.0 mg/L was necessary for good biodegradation and improvement of the liquid redox status. Nitrification occurred at higher ORP values (380 to 420 mV) than was the case for organic substrate oxidation (250 to 300 mV). The microprofiles obtained from microelectrode measurements substantiate the heterogeneity of the microbial processes inside activated sludge flocs. Because of microbial oxygen utilization, the aerobic region in the activated sludge floc was limited to the top layer (0.1 to 0.2 mm) of the activated sludge aggregate present in medium-strength wastewater, with an anoxic zone dominating inside the flocs. When dissolved oxygen in the bulk water was higher than 4.0 mg/L, the anoxic zone inside the floc disappeared. At low wastewater pollutant concentrations, the ORP and dissolved oxygen inside the activated sludge aggregates were higher than those from medium-strength wastewater. The prospect of using ORP as an online control approach for aeration tank operation and the potential reasons for activated sludge floc size varying with pollutant strengths are also discussed.  相似文献   

17.
设计并利用在差压仪中密闭投加基质的实验方法,根据ASM模型中自养菌和硝化过程耗氧速率的关系,对比研究了ECOSUNIDE工艺和其他4个污水处理厂曝气池混合液中自养菌的浓度。研究表明,在不考虑自养菌增长和衰减情况下,ECOSUNIDE工艺混合液自养菌生物浓度为48.15 mg COD/L,该结果显著高于其他受试污水处理厂的混合液自养菌生物浓度(17.2~37.5 mg COD/L),表明ECOSUNIDE工艺在提高活性污泥中自养菌生物浓度上有较强的优势。设计的实验方法可以简便、有效地测定用于ASM模型中的自养菌浓度。  相似文献   

18.
实际污水与模拟污水活性污泥系统的特性差异   总被引:2,自引:0,他引:2  
实验中经常采用人工配置的模拟生活污水,为了研究其与实际生活污水活性污泥系统的特性差异,采用2个序批式间歇反应器(SBR)进行平行实验(厌氧、好氧方式运行),系统地考察了在进水主要组分和运行参数相同的情况下,不同原水对活性污泥系统脱氮、除磷、比好氧速率、污泥絮体形态和出水水质等方面的影响。结果表明,模拟污水系统的硝化活性强于实际污水系统,两者的平均硝化速率分别为7.43 mg NH4+-N/(L.h)和5.55 mg NH4+-N/(L.h)。在前置厌氧段,模拟污水系统的释磷量比实际污水系统高出36.45%。两者在后续好氧阶段都能够充分吸磷。模拟污水系统的平均比好氧速率(SOUR)高达64.54 mg O2/(g MLSS.h),而实际污水系统的则只有32.81 mg O2/(g MLSS.h)。模拟污水系统的污泥絮体疏松,粒径小,形状不规则,沉降性差,沉后出水平均悬浮物浓度(SS)为20 mg/L;而实际污水系统的污泥絮体则密实、粒径大,沉降性好,沉后水十分清澈,SS几乎检测不出。  相似文献   

19.
Literature shows that full-scale pure-oxygen activated sludge (O2-AS) wastewater treatment plants (WWTPs) generate effluents with higher dissolved-organic carbon (DOC) concentrations and larger high-molecular-weight fractions compared to air-activated-sludge (Air-AS) WWTP effluents. The purpose of this paper was to evaluate how gas supplied (air vs. pure oxygen) to sequencing-batch reactors affected DOC transformations. The main conclusions of this paper are (a) O2-AS effluent DOC is more refractory than air-AS effluent DOC; and (b) O2-AS systems may have higher five-day biochemical oxygen demand removals than air-AS systems; however, in terms of COD and DOC removal, air-AS systems are better than O2-AS systems. Analysis of a database from side-by-side O2- and air-AS pilot tests from literature supported these observations.  相似文献   

20.
Water soluble hydrophobically associated polyelectrolytes were copolymerised with dimethyl- [2-(2-methyl-acryloyloxy)-ethyl]-alkyl ammonium bromide (alkyl: propyl, hexyl, dodecyl) (DEACn) and acrylamide (AM) in inverse emulsion. Cationic hydrophobically modified polyacrylamides having different molecule weight and cationic degree were obtained by varying the total monomer concentration and DEACn/AM mole ratio. Polyelectrolytes were characterised by 1H-NMR and 13C-NMR. The dewatering indexes, such as CST, settling rate and water content in sludge cake were investigated and used to evaluate the dewaterability and settleability of activated sludge conditioned by these polyelectrolytes. Afterwards, some characteristics of sludge floc, such as: floc size, sludge viscosity and floc strength were measured. The function of hydrophobic association in sludge conditioning was elucidated by comparing dewatering performances with these polyelectrolytes  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏