1.
Treatment of landfill leachate by ozone-based advanced oxidation processes   总被引:13,自引:0,他引:13  
Wu JJ  Wu CC  Ma HW  Chang CC 《Chemosphere》2004,54(7):997-1003
In this study, laboratory experiments are conducted to compare the efficacy using several ozone-based advanced oxidation processes (AOPs), such as O3, O3/H2O2, and O3/UV, to treat landfill leachate. Raw leachate was initially coagulated by ferric chloride (FeCl3) at the experimental-determined optimal dosage of 900 mgl(-1), and the ozone-based AOPs were subsequently applied. Results indicate that all AOPs would result in a significant increase on the ratio of BOD5/COD from 0.06 to 0.5 at the applied ozone dosage of 1.2 gl(-1). The increase on biodegradability for ozonated leachate indicates that these AOPs would be beneficial to the subsequent biological treatment process. To better explain the alteration of high organic molecules after oxidation, ultrafiltration was used to separate the leachate by several molecular weight cutoffs (MWCO). The COD distribution for coagulated leachate is 34% for MWCO>10 kDa, 7% for MWCO between 5 and 10 kDa, 22% for MWCO between 1 and 5 kDa, and 37% for MWCO<1 kDa. Following ozonation or AOPs, the predominant distribution of COD would be obviously shifted to the MWCO less than 1000 gmol(-1) (72-85%) over the other MWCO ranges. In addition, Gel Permeation Chromatograph (GPC) analysis has showed a substantial agreement on the cleavage of larger organic compounds into smaller ones. O3/UV was found to be the most effective approach among these ozone-based AOPs to enhancing the biodegradability and eliminating the color of leachate.  相似文献   

2.
Fan HJ  Chen IW  Lee MH  Chiu T 《Chemosphere》2007,67(8):1647-1652
Due to the growing concern of highly contaminated landfill leachate problems in Taiwan, an innovative advanced catalytic oxidation (FeGAC/H(2)O(2)) process was developed and employed in this research to treat the landfill leachate from central Taiwan. Experimental results indicated that the FeGAC/H(2)O(2) process could effectively remove organic compounds from landfill leachate. The presence of iron oxide coated granular activated carbon (FeGAC) greatly improved the oxidative ability of H(2)O(2) for the removal of humic acids, fulvic acids and non-humic substance from leachate. For instance, at pH 6, the removal efficiencies of FeGAC/H(2)O(2) and H(2)O(2) processes were 70% and 8%, respectively. FeGAC/H(2)O(2) combined both advantages of FeGAC and H(2)O(2) where FeGAC had good organics adsorption ability and could effectively catalyse the hydrogen peroxide oxidation reaction for organics removal.  相似文献   

3.
Fenton's pre-treatment of mature landfill leachate   总被引:20,自引:0,他引:20  
Lopez A  Pagano M  Volpe A  Di Pinto AC 《Chemosphere》2004,54(7):1005-1010
The aim of this study was to check the effectiveness of the Fenton's reagent (Fe2+ + H2O2 + H+) for the pre-treatment of a municipal landfill leachate with the objective of improving its overall biodegradability, evaluated in terms of BOD5/COD ratio, up to a value compatible with biological treatment. The leachate came from a municipal sanitary landfill located in southern Italy and the average values of its main parameters were: pH=8.2; COD=10,540 mgl(-1); BOD5=2,300 mgl(-1); TOC=3,900 mgl(-1); NH4-N=5210 mgl(-1); conductivity=45,350 microScm(-1); alkalinity=21,470 mgl(-1) CaCO3. The effect of initial pH value on the pre-treatment effectiveness was evaluated by titrating the amount of acidic by-products formed. The extent of leachate oxidation was monitored and controlled by both pH and redox potential measurements. The best operational conditions for achieving the desired goal (i.e., BOD5/COD> or =0.5) resulted: Fe2+=275 mgl(-1); H2O2=3,300 mgl(-1); initial pH=3; reaction time=2 h. At the end of the Fenton's pre-treatment, in order to permit a subsequent biological treatment, residual ferric ions were removed increasing the pH up to 8.5 by adding 3 gl(-1) of Ca(OH)2 and 3 mgl(-1) of a cationic polyelectrolyte, the latter as an aid to coagulation. This final step also resulted in a further modest removal of residual COD due to co-precipitation phenomena.  相似文献   

4.
光电芬顿氧化法深度处理垃圾渗滤液研究   总被引:6,自引:1,他引:5  
采用光电芬顿氧化法对北京市某垃圾填埋场已经生化处理后的垃圾渗滤液进行深度处理,分别考察了电流强度和铁的不同价态等因素对渗滤液总有机碳(TOC)、化学需氧量(COD)以及色度去除效果的影响,并对阳极氧化、电芬顿和光电芬顿不同反应过程进行了对比。通过分析渗滤液UV-Vis光谱(200~500 nm)变化和渗滤液中有机污染物的分子量变化,发现光电芬顿反应可以明显改善渗滤液生化性。深入研究了反应过程中铁价态的变化规律。试验结果发现,以高比表面积的活性炭纤维(ACF)为阴极的光电芬顿反应可以有效降解垃圾渗滤液,在pH为3,Fe2+ 浓度为1 mmol/L,电流为0.5 A,O2通入量为250 mL/min条件下降解360 min,垃圾渗滤液TOC和COD去除率分别达到78.9%和62.8%,色度完全去除。  相似文献   

5.
In this study, the applicability of physico-chemical methods was investigated for the pre-treatment of the olive mill effluents prior to the discharge into the common sewerage ending with a municipal wastewater treatment plant. The samples were taken from an olive oil industry operated as three-phase process located in Turkey. Various pre-treatment methods including acid craking, polyelectrolyte and lime additions were applied. Advanced oxidation study using Fenton's process was also investigated following pre-treatment by acid cracking and cationic polyelectrolyte. Acid cracking alone gave satisfactory treatment efficiencies and polyelectrolite additions to the acid-cracked samples enhanced treatment efficiency. Since a complete treatment plant is available at the end of the sewer system, results indicated that the effluents of the investigated industry could be discharged into the municipal sewerage in the case of total chemical oxygen demand (COD(tot)), suspended solid (SS) and volatile suspended solid (VSS) concentrations according to the Turkish Water Pollution Control Regulation after pre-treatment with 5 ppm anionic polyelectrolyte following acid cracking. The minimum COD(tot), SS and VSS removals were observed when raw wastewater was pre-treated with lime and the discharge standards to the municipal sewer system could not be met. Advanced oxidation with Fenton's process was applied after acid cracking and cationic polyelectrolyte treatment in order to investigate further reduction in chemical oxygen demand (COD) concentration for minimizing the influence of this industrial discharge on the existing municipal wastewater treatment plant. Results indicated that COD(tot) removal increased up to 89% from 74% after Fenton's oxidation for the acid cracked samples in which cationic polyelectrolite (10 ppm) was added.  相似文献   

6.
Fenton组合工艺处理焦化厂生化出水的应用研究   总被引:2,自引:1,他引:1  
比较了Fenton氧化、Fenton氧化+活性炭及Fenton氧化+生物活性炭工艺对焦化厂生化出水的处理效果.结果表明,Fe2+、H2O2的投加量分别为56、27.2 mg/L时,Fenton氧化工艺对水样的UV254、颜色度(VIS380)、COD和总氰均有较好的去除效果;Fenton氧化+活性炭工艺在有效去除UV254、VIS380、COD和总氰的同时,能强化活性炭的吸附效果,并能显著提高水样的生化性能;Fenton氧化+生物活性炭工艺能有效去除UVM254,VIS380、COD与总氰,使出水达到<污水综合排放标准>(GB 8978-1996)一级标准.  相似文献   

7.
In this paper we evaluated the H2O2/UV and the Fenton's oxidation processes for the treatment of tannery wastewater under different experimental conditions. Efficiencies were judged by the amounts of organic substances degraded or eliminated under these treatment techniques. Daphnia magna and Vibrio fischeri were used to monitor toxicity. Organic compounds contained in the untreated and treated tannery wastewater were determined and identified using substance specific techniques. Gas chromatography-mass spectrometry (GC-MS) in positive electron impact (EI(+)) mode was applied to determine volatile organics. Atmospheric pressure ionization (API) mass (MS) and tandem mass spectrometry (MS-MS) coupled with flow injection analysis (FIA) or liquid chromatography (LC) were used to detect or identify polar organic pollutants. The experimental results indicated that both oxidation processes--H2O2/UV at pH 3 and Fenton at pH 3.5--are able to reduce TOC content by mineralisation of the organic compounds.  相似文献   

8.
Fenton''s type reaction and chemical pretreatment of PCBs   总被引:3,自引:0,他引:3  
This study evaluates the effects of Fenton's reagent (FR) on the rate and extent of the oxidative degradation of individual mono, di-, tri- and tetrachlorobiphenyls in the commercial mixture DELOR 103, equivalent to AROCLOR 1248. The oxidation effect of FR strongly increased with increasing the molar ratio of Fe2+/H2O2. The most effective oxidation of DELOR 103 (10 μg.ml−1) was achieved in a solution containing 1M H2O2 and 1 mM Fe2+. The FR elimination rate constants of PCB congeners decrease with increasing number of chlorine substituents in the biphenyl molecule and show a good correlation with the values of molecular weights of the PCB congeners and their 1-octanol/water partition coefficients.  相似文献   

9.
为加速好氧填埋场的稳定化进程,提出利用生物强化技术加速好氧填埋垃圾的生物降解,通过模拟实验,研究了微生物菌剂对填埋垃圾稳定过程的影响。结果表明:微生物菌剂降低了好氧填埋场的有机污染负荷,使渗滤液COD下降更加明显,整个填埋周期所产渗滤液的COD总量较对照组少20.20%;加速了含氮物质的生物转化,氨氮峰值出现较对照组提前6 d,经历峰值以后,氨氮快速下降,较对照组提前22 d达到国家生活垃圾填埋场污染控制标准(GB 16889-2008)所规定的渗滤液氨氮排放标准25 mg/L,并使整个填埋周期氨氮总量减少9.15%;微生物菌剂降低了渗滤液的产量,使整个填埋周期渗滤液累计产量减少8.29%;使垃圾中有机质降解加快并使其降解更加彻底,至实验结束时总有机质含量较对照组低8.82%,干重较对照组减少35.95%;沉降性能优于对照组,至填埋结束时较对照组沉降量提高6.35%。  相似文献   

10.
Activated carbon adsorption and chemical oxidation followed by activated carbon adsorption of resorcinol in water has been studied. Three chemical oxidants have been used: hypochlorite, permanganate and Fenton's reagent. The influence of concentrations of resorcinol and activated carbon on adsorption removal rates has been investigated. Both isotherm and adsorption kinetics have been studied. Results are fit well by Freundlich isotherms and adsorption rates of resorcinol were found to follow a pseudo-second-order kinetic model. However, pyrogallol, an intermediate of resorcinol oxidation with permanganate and Fenton's reagent, showed an unfavourable isotherm type. At the conditions investigated, chemical oxidation allows slight reductions of TOC and intermediates formed were found to inhibit the adsorption rate of TOC in the case of permanganate and Fenton's reagent oxidation, likely due to formation of some polymer pyrogallol product. The adsorption process was found to be controlled by pore internal diffusion, which justifies the poor affinity of oxidation intermediates toward activated carbon since molecules of larger size should diffuse rapidly for the adsorption to be effective.  相似文献   

11.
垃圾渗滤液生物处理出水臭氧氧化的研究   总被引:3,自引:1,他引:2  
对垃圾渗滤液生物处理出水进行了臭氧氧化的研究。研究表明,随着氧化时间的延长,CODCr去除率增大;在碱性条件下进行臭氧氧化。pH越高,CODCr去除效率越高。采用BOD5/CODCr来表征垃圾渗滤液的生物降解性,研究了臭氧氧化前后垃圾渗滤液生物处理出水的生物降解性变化规律,表明臭氧氧化可以提高垃圾渗滤液生物处理出水的生物降解性,但提高的幅度不大。通过色谱-质谱法(GC—MC)对臭氧氧化前后垃圾渗滤液的成分进行分析,结果表明,臭氧氧化前后废水中的主要成分没有发生变化,仍然为难降解物质;臭氧氧化使废水中的部分物质发生了结构上的变化,减少、消失和生成的物质多为可降解物质。  相似文献   

12.
Iron-loaded mangosteen shell powder (Fe-MSP) was found as an effective heterogeneous Fenton catalyst for the treatment of stabilized landfill leachate. Sonolytically produced catalyst has higher efficiency than other catalysts. At the optimal conditions (pH 3, catalyst concentration of 1,750 mg/L and hydrogen peroxide concentration of 0.26 M), 81 % of the chemical oxygen demand (COD) was removed effectively from the landfill leachate. But, the efficiency of Fe-MSP was reduced in the first recycling due to the poisoning of active sites. A metal leaching study indicated that the degradation of the pollutant is mainly due to solid Fe ions present in Fe-MSP rather than the leached ferrous and ferric ions. Hydroxyl radical production in the system was confirmed by the Fenton oxidation of benzoic acid. Compared to the homogeneous Fenton process, the heterogeneous Fenton process using Fe-MSP had higher COD removal efficiency, indicating the practical applicability of the prepared catalyst.  相似文献   

13.
The removal performance of typical refractory organic compounds in landfill leachate was investigated during the electrochemical (EC) oxidation and anaerobic process combined treatment system in this paper. The results indicated that the treatment of landfill leachate by the combined system was highly effective. The toxicity of leachate was notably decreased after the electrochemical oxidation process and the biodegradability was improved. The concentration of the organic acid with low molecular weight in the leachate increased from 28% to 90% based on the biodegradability assays after the EC oxidation process. The anaerobic digestion could further remove the residual organic compounds. At a hydraulic retention time (HRT) of 16 hours and an organic loading rate (OLR) of 8 kg COD/m3 d, the concentration of COD, SS, ALK, VA, N-TKN, N-NH4+ and P-PO4(3)- [corrected] in UASB effluent were 532, 12, 6744, 400, 540, 455 and 11.6 mg/L, respectively, with approximately 90% removal efficiency of COD. The organic compounds in the landfill leachate revealed different degradation characteristics in the combined system. p-chloroaniline, bisphenol A, 6-methyl-2-phenyl-quinoline, dimethylnaphthaline and N'-(2-methyl-4-chlorophenyl)-N-cyclohexyformamidine, classified into the first group in this paper, were completely removed by the EC oxidation and did not reappear in the effluent of the UASB reactor. Phenylacetic acid, 3-methyl-indole and N-cyclohexyl-acetamide, called the second group, were completely removed, but reappeared in the UASB reactor. 4-methyl-phenol, 3,4-dihydroisoquinoline, 2(3H)-benzothiazolone, exo-2-hydroxycineole and benzothiazole, the third group, were degraded little in the EC oxidation process, but extensively removed by the anaerobic process. Benzoic acid, benzenepropanoic acid and 2-cyano-3,5-dimethyl-1-hydroxypyrrole, the fourth group, concentration obviously increased in the EC process, but was completely removed in the UASB reactor. The content of volatile fatty acids (VFAs) markedly increased from 0.68% in the leachate to 16.18% in the effluent from the electrochemical oxidation process (EC(effl)). In addition, the degradation rate of organic compounds from the landfill leachate was different in the EC oxidation and anaerobic process.  相似文献   

14.
缺氧-SBR法-混凝法工艺处理垃圾渗滤液的试验研究   总被引:1,自引:0,他引:1  
采用缺氧 -SBR法 -混凝沉淀复合工艺对城市垃圾渗滤液进行处理 ,确定缺氧、SBR法和混凝的最佳运行参数。结果表明 ,通过该系统处理后 ,COD总去除率达到 91.2 % ,NH3 N去除率达 90 .4 % ,取得较好的去除有机物和脱氮效果  相似文献   

15.
Wastewater from the Afyon Alkaloids Factory (Afyon, Turkey) was subjected to low-pressure catalytic wet-air oxidation (CWAO) using Fenton's reagent, and the optimal reaction conditions were investigated. The CWAO using Fenton's reagent was applied to the factory effluent, diluted factory effluent, and aerobically pretreated wastewater. To find the optimum quantities of reagents, ferrous iron (Fe(+2))-to-substrate ratios of 1:10, 1:25, and 1:50 and hydrogen peroxide (H2O2)-to-Fe(+2) ratios of 1, 5, and 10 were investigated, and the treatment was carried out at different temperatures. High chemical oxygen demand (COD) removals were obtained at 50 degrees C, with the Fe(+2)-to-substrate ratio range between 1:10 and 1:25. The change in H2O2-to-Fe(+2) ratios did not cause any considerable effect. Also, the percentages of COD removals were nearly the same, so the ratio H2O2:Fe(+2):1 is recommended. Aerobic pretreatment seems to be effective. On the other hand, no enhancement was observed in the case of the diluted wastewater.  相似文献   

16.
采用膨胀颗粒污泥床(EGSB)反应器对城市生活垃圾焚烧厂产生的垃圾沥滤液进行处理。实验结果表明:中温条件下,当COD浓度为55 000 mg/L左右,有机容积负荷(OLR)为22.8 kg COD/(m3.d)时,EGSB对垃圾沥滤液具有较好的的处理效果,COD去除率可达94.2%。当进水COD为72 000 mg/L左右时,为保证反应器的稳定运行,OLR应降低至18.2 kg COD/(m3.d),此时COD去除率可以达到88%左右,出水COD平均为9 103 mg/L。垃圾沥滤液和EGSB处理出水均以小分子量有机物为主,其中<4 kDa的有机物分别占76.5%和74.4%。EGSB对整个分子量区间的溶解性有机物都有较好的处理效果,其中对大分子有机物的处理效率相对更高。  相似文献   

17.
Chen WS  Juan CN  Wei KM 《Chemosphere》2005,60(8):1072-1079
Fenton's reagent, UV/H2O2 and UV/Fenton's reagent were employed to mineralize dinitrotoluene (DNT) isomers and 2,4,6-trinitrotoluene (TNT) of spent acid in toluene nitration process. The bench-scale experiments were conducted to elucidate the influence of various operating variables on the performance of removal of total organic compounds (TOC) from spent acid, including reaction temperature, concentration of ferrous ion and H2O2 dosage. It is remarkable that organic compounds were completely mineralized by Fenton oxidation, of which removal efficiency is superior to that of UV/H2O2. Nevertheless, it makes slight difference between Fenton oxidation and UV/Fenton oxidation. According to the spectra identified by gas chromatograph/mass spectrometer (GC/MS), it is proposed that oxidative degradation of DNT isomers leads to o-, m-, p-mononitrotoluene (MNT) and 1,3-dinitrobenzene respectively. Besides, the oxidation of 2,4,6-TNT gives the 1,3,5-trinitrobenzene intermediate. Apparently, Fenton oxidation is promising for purification of spent acid industrially.  相似文献   

18.
The destruction of a carbon tetrachloride DNAPL and a chloroform DNAPL was investigated in reactions containing 0.5 mL of DNAPL and a solution of modified Fenton's reagent (2M H2O2 and 5mM iron(III)-chelate). Carbon tetrachloride and chloroform masses were followed in the DNAPLs, the aqueous phases, and the off gasses. In addition, the rate of DNAPL destruction was compared to the rate of gas-purge dissolution. Carbon tetrachloride DNAPLs were rapidly destroyed by modified Fenton's reagent at 6.5 times the rate of gas purge dissolution, with 74% of the DNAPL destroyed within 24h. Use of reactions in which a single reactive oxygen species (hydroxyl radical, hydroperoxide anion, or superoxide radical anion) was generated showed that superoxide is the reactive species in modified Fenton's reagent responsible for carbon tetrachloride DNAPL destruction. Chloroform DNAPLs were also destroyed by modified Fenton's reagent, but at a rate slower than the rate of gas purge dissolution. Reactions generating a single reactive oxygen species demonstrated that chloroform destruction was the result of both superoxide and hydroxyl radical activity. Such a mechanism of chloroform DNAPL destruction is in agreement with the slow but relatively equal reactivity of chloroform with both superoxide and hydroxyl radical. The results of this research demonstrate that modified Fenton's reagent can rapidly and effectively destroy DNAPLs of contaminants characterized by minimal reactivity with hydroxyl radical, and should receive more consideration as a DNAPL cleanup technology.  相似文献   

19.
In this study, advanced oxidation process utilizing Fenton's reaction was investigated for the decolorization and degradation of two commercial dyes viz., Red M5B, Blue MR and H-acid, a dye intermediate used in chemical industries for the synthesis of direct, reactive and azo dyes. Effect of Fe2 +, H2O2, pH, and contact time on the degradation of the dyes was studied. Maximum color and COD removal was obtained for Red MSB, H-acid and Blue MR at 10-25 mg/l of Fe2+ dose and 400-500 mg/l of H2O2 dose at pH 3.0. The initial oxidation reaction was found to fit into first order rate kinetics and the rate of oxidation of H-acid was higher than the other dyes. Release of chloride and sulfate from the Fenton's treated Red M5B dye and sulfate from H-acid and Blue MR indicates that the dye degradation proceeds through cleavage of the substituent group.  相似文献   

20.
Chan KH  Chu W 《Chemosphere》2003,51(4):305-311
The degradation of pesticide, atrazine (ATZ), 2-chloro-4-(ethylamino)-6-(isopropylamino)-s-triazine, by Fenton's reagent (FR) was investigated as a function of reagents' concentrations and ratios in a batch reactor. The degradation of ATZ was effectively achieved by hydroxyl radicals, which were generated in the FR process. The decay rates of ATZ and the oxidation capacities of FR were found to depend on the concentrations of hydrogen peroxide and ferrous ion. The removal kinetics of ATZ are initiated by a rapid decay and then followed by a much slower one. After an extended reaction time (5-10 min), the reactions ceased because the Fe(II) and H(2)O(2) were consumed and would be deactivated in the process. A mathematical model was successfully developed to describe the two-stage reaction kinetics by using two simple but critical parameters: the initial ATZ decay rate and the final oxidation capacity of Fenton's process. In general, higher [Fe(II)] or H(2)O(2) concentrations result in faster initial decay rate and higher oxidation capacity. However, the oxidation capacity is more sensitive to the initial [Fe(II)] due to the presence of side reactions as discussed in the paper.  相似文献   