首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Large amounts of construction materials will be needed in Europe in anticipation for capping landfills that will be closed due to the tightening up of landfill legislation. This study was conducted to assess the potential environmental impacts of using refuse derived fuel (RDF) and municipal solid waste incineration (MSWI) ashes as substitutes for natural materials in landfill cover designs. The leaching of substances from a full-scale landfill cover test area built with different fly and bottom ashes was evaluated based on laboratory tests and field monitoring. The water that drained off above the liner (drainage) and the water that percolated through the liner into the landfill (leachate) were contaminated with Cl?, nitrogen and several trace elements (e.g., As, Cu, Mo, Ni and Se). The drainage from layers containing ash will probably require pre-treatment before discharge. The leachate quality from the ash cover is expected to have a minor influence on overall landfill leachate quality because the amounts generated from the ash covers were low, <3–30 l (m2 yr)?1. Geochemical modelling indicated that precipitation of clay minerals and other secondary compounds in the ash liner was possible within 3 years after construction, which could contribute to the retention of trace elements in the liner in the long term. Hence, from an environmental view point, the placement of ashes in layers above the liner is more critical than within the liner.  相似文献   

2.
Single- or multi-layered surface barriers are used for protecting the underlying hazardous or radioactive waste storage facility and for reducing the risk of dispersion of contaminants to the ground water. To assess the effect of variations in net rainfall rate (total rainfall minus evapotranspiration) on the hydraulic response of a multi-layered barrier, a series of flow simulations were performed. Water fluxes in different layers of the barrier were numerically calculated for three net rainfall rates, i.e. 0.0255, 0.0742, and 0.141 cm/day. These rates correspond to dry, average, and wet climatological conditions in Belgium. Results show that for dry conditions, almost 45% of the water infiltrating the top of the barrier is laterally evacuated. When the net rainfall rate increases from 0.0255 to 0.0742 cm/day, more water is being laterally diverted, and only 22% of the applied rainfall percolates through the barrier. If the rainfall rate is increased from 0.0255 to 0.141 cm/day, the percolation becomes 14% of the applied rainfall. This indicates that fluxes leaving the bottom of the repository increase only slightly, although the rainfall rate for wet conditions is approximately 5 times larger than for dry conditions. Under dry conditions a slightly negative pressure develops in the bottom of the low-permeability clay layer. However, this desaturation does not affect the integrity of the clay.  相似文献   

3.
This research concentrates the design, construction and evaluation of simulated pilot scale landfill lysimeter at KUET campus, Khulna, Bangladesh. Both the aerobic and anaerobic conditions having a base liner and two different types of cap liner were simulated. After the design of a reference cell, the construction of landfill lysimeter was started in January 2008 and completed in July 2008. In all construction process locally available civil construction materials were used. The municipal solid waste (MSW) of 2800–2985 kg having the total volume of 2.80 m3 (height 1.6 m) and moisture content of 65% was deposited in each lysimeter by applying required compaction energy. In contrast, both the composition in terms of methane (CH4), carbon dioxide (CO2) and oxygen (O2) as well as the flow rate of landfill gas (LFG) generated from MSW in landfill lysimeter were measured and varied significantly in relation to the variation of lysimeter operational condition. Moreover, anaerobic lysimeter-C shows the highest composition of LFG in compare to the anaerobic lysimeter-B due to the providing of lower compaction of cap liner in anaerobic lysimeter-C. Here, it is interesting to note that in absence of compacted clay liner (CCL) and hence percolation of rainwater that facilitates rapid degradation of MSW in aerobic lysimeter-A has resulted in the highest settlement than that of anaerobic landfill lysimeter-B and C. Moreover, in case of anaerobic lysimeter-B and C, the leachate generation was lower than that of aerobic lysimeter-A due to the providing of cap liner in anaerobic lysimeter-B and C, played an important role to reduce the percolation of rainwater. The study also reveals that the leachate pollution index (LPI) has decreased in relation to the increasing of elapsed period as well as the LPI for collection system of aerobic lysimeter-A was higher than that of the collection system of anaerobic lysimeter-B and C. Finally, it can be depicted that LPI for lysimeter was significantly high and proper treatment will be necessary before discharging the lysimeter leachate into the water bodies.  相似文献   

4.
Leachate recirculation or liquid injection in municipal solid waste landfills offers economic and environmental benefits. The key objective of this study was to carry out numerical evaluation of key design variables for leachate recirculation system consisting of vertical wells. In order to achieve the objective, numerical modeling was carried out using the finite-element model HYDRUS-2D. The following design parameters were evaluated by simulating liquid pressure head on the liner and the wetted width of the waste under steady-state flow conditions: (1) hydraulic conductivities of the waste and vertical well backfill; (2) liquid injection rate and dosing frequency; (3) well diameter, screen height and screen depth; and (4) hydraulic conductivity of the leachate collection system, slope of the leachate collection system and spacing of the leachate collection pipes. The key findings of this study are as follows. The well diameter, hydraulic conductivity of the well drainage pack, and screen height and screen depth of the well have very little effect on the wetted width for a given liquid flux. The wetted width and the injection pressure for a given liquid flux decrease with the increase in the hydraulic conductivity of the waste. The pressure head on the liner increases with the decrease in the vertical distance between the bottom of the well screen and the top of leachate collection system. The liquid injection flux increases with the decrease in hydraulic conductivity of the leachate collection system. Unlike sand (k approximately 10(-4)m/s), pea gravel (k approximately 0.01 m/s) resulted in less than 0.3m pressure head on the liner for all simulations carried out in this study.  相似文献   

5.
The practice of operating municipal solid waste landfills as bioreactor landfills has become more common over the past decade. Because simulating moisture balance and flow is more critical in such landfills than in dry landfills, researchers have developed methods to address this problem using the hydrologic evaluation of landfill performance (HELP) model. This paper discusses three methods of applying the HELP model to simulate the percolation of liquids added to landfill waste: the leachate recirculation feature (LRF), the subsurface inflow (SSI) feature, and additional rainfall to mimic liquids addition. The LRF is simple to use but may not be able to bring the landfill to bioreactor conditions. The SSI feature provides a convenient user interface for modeling liquids addition to each layer. The additional rainfall feature provides flexibility to the model, allowing users to estimate the leachate generation rate and the leachate head on bottom liner associated with daily variation in the liquids addition rate. Additionally, this paper discusses several issues that may affect the HELP model, such as the time of model simulation, layers of liquids addition, and the limitations of the HELP model itself. Based on the simulation results, it is suggested that the HELP model should be run over an extended period of time after the cessation of liquids addition in order to capture the peak leachate generation rate and the head on the liner (HOL). From the perspectives of leachate generation and the HOL, there are few differences between single-layer injection and multiple-layer injection. This paper also discusses the limitations of using the HELP model for designing and permitting bioreactor landfills.  相似文献   

6.
Conventional landfill cover systems for municipal solid waste include low-permeability compacted clay barriers to minimize infiltration into the landfilled waste. Such layers are vulnerable in climates where arid to semi-arid conditions prevail, whereby the clay cover tends to desiccate and crack, resulting in drastically higher infiltration, i.e., lower cover efficiency. To date, this phenomenon, which has been reported in field observations, has not been adequately assessed. In this paper, the performance of a cover system solely relying on a clay barrier was simulated using a numerical finite element formulation to capture changes in the clay layer and the corresponding modified hydraulic characteristics. The cover system was guided by USEPA Subtitle-D minimum requirements and consisted of a clay layer underlying a protective vegetated soil. The intrinsic characteristics of the clay barrier and vegetative soil cover, including their saturated hydraulic conductivities and their soil-water characteristic curves, were varied as warranted to simulate intact or "cracked" conditions as determined through the numerical analyses within the proposed methodology. The results indicate that the levels of percolation through the compromised or cracked cover were up to two times greater than those obtained for intact covers, starting with an intact clay hydraulic conductivity of 10(-5)cm/s.  相似文献   

7.
A review of aqueous-phase VOC transport in modern landfill liners   总被引:3,自引:0,他引:3  
Leachates from municipal solid waste (MSW) and hazardous waste landfills contain a wide range of volatile organic compounds (VOCs) in addition to inorganic compounds. VOCs have been shown to migrate and contaminate the surrounding environment and impair the use of groundwater. Therefore, the effectiveness of modern landfill liner systems to minimize migration of VOCs is of concern. Most modern landfills employ a composite liner consisting of a geomembrane overlying a compacted clay liner or a geosynthetic clay liner. The geomembrane is often believed to be the primary barrier to contaminant transport. However, for VOCs, the clay component usually controls the rate of transport since VOCs are shown to diffuse through geomembrane at appreciable rates. Additionally, analyses have shown that transport of volatile organic compounds (VOCs) generally is more critical than transport of inorganic compounds (e.g., toxic heavy metals), even though VOCs are often found at lower concentrations in leachates. Therefore, the effectiveness of modern landfill liner systems to minimize migration of VOCs and transport of VOCs through clay liners and modeling of transport through composite liners merit scrutiny. This paper presents a review of recent research by the author and others on these topics. A systematic and comprehensive approach to determine mass transport parameters for transport of VOCs in liquid phase through compacted clay liners, geosynthetic clay liners (GCLs), and geomembranes has enabled to develop realistic models to predict mass flux of VOCs through modern composite liners and provide a quantitative basis to evaluate potential for transport of dissolved VOCs and the equivalency of different composite liners.  相似文献   

8.
An alternative landfill capping technique known as ‘Phytocapping’ (establishment of perennial plants on a layer of soil placed over the waste) was trailed in Rockhampton, Australia. In this technique, trees were used as ‘bio-pumps’ and ‘rainfall interceptors’ and soil cover as ‘storage’ of water. The environmental performance of the phytocapping system was measured based on its ability to minimise water percolation into the waste. The percolation rate was modelled using HYDRUS 1D for two different scenarios (with and without vegetation) for the thick and thin caps, respectively. Results from the modelling showed percolation rates of 16.7 mm year?1 in thick cover and 23.8 mm year?1 in thin cover, both of which are markedly lower than those expected from a clay cap. Results from monitoring and observations showed that 19 trees out of 21 tree species grew well in the harsh landfill environment. Top ten performing species have been identified and are recommended to be grown on phytocaps in the Central Queensland region.  相似文献   

9.
Heat generated by the biodegradation of waste and other chemical processes in a landfill can potentially affect the long-term performance of landfill liner system, in particular that of a high-density polyethylene geomembrane. In a double liner system, the difference in leachate exposure and temperature might improve the long-term performance of the secondary geomembrane compared to that of the primary geomembrane. However, in some cases, the temperature is likely to be high enough to substantially reduce the service-life of the secondary geomembrane. This study explores the possible effectiveness of using tire chips as thermal insulation between primary and secondary liners to reduce the temperature of secondary geomembranes as compared to traditional soil materials. Heat and contaminant migration analyses are performed for cases with no insulation and for cases in which a layer of soil or tire chips has been used as thermal insulation between the primary and secondary liners. The effect of insulation on prolonging the service-life of a secondary geomembrane and, consequently, on contaminant transport through a liner system is examined for the case of a volatile organic compound (dichloromethane) found in landfill leachate. The study suggests that the use of tire chips warrants consideration, however there are other practical issues that require consideration in the detailed design and construction of landfill liners. Issues such as finite service-life, low working temperature, excessive settlement, ability to generate internal heat, leaching of tire chips and limitations in performing electrical resistivity leak detection tests are identified.  相似文献   

10.
Landfill bottom liners are generally constructed with natural clay soils due to their high strength and low hydraulic conductivity characteristics. However, in recent years it is increasingly difficult to find locally available clay soils that satisfy the required engineering properties. Fine grained soils such as sepiolite and zeolite may be used as alternative materials in the constructions of landfill bottom liners. A study was conducted to investigate the feasibility of using natural clay rich in kaolinite, sepiolite, zeolite, and their mixtures as a bottom liner material. Unconfined compression tests, swell tests, hydraulic conductivity tests, batch and column adsorption tests were performed on each type of soil and sepiolite–zeolite mixtures. The results of the current study indicate that sepiolite is the dominant material that affects both the geomechanical and geoenvironmental properties of these alternative liners. An increase in sepiolite content in the sepiolite–zeolite mixtures increased the strength, swelling potential and metal adsorption capacities of the soil mixtures. Moreover, hydraulic conductivity of the mixtures decreased significantly with the addition of sepiolite. The utilization of sepiolite–zeolite materials as a bottom liner material allowed for thinner liners with some reduction in construction costs compared to use of a kaolinite-rich clay.  相似文献   

11.
While the cathode ray tube (CRT) funnel containing lead could be transported to a smelting facility to recover lead, which could be an available option in domestic, a proper technology to recycle a CRT panel must be developed. Thus, it was suggested that CRT panel glass be used as aggregates of concrete blocks and clay bricks. Samples of blocks and bricks were fabricated with CRT powders and tested to measure their strength and absorption rate to determine their qualities, and environmental soundness was determined by measuring the leaching rate of hazardous metals. For concrete blocks, CRT panel glass powders incorporated as aggregates up to 40 % replacing stone powder was proposed as the proper condition for manufacturing blocks. Around 2 % of CRT panel incorporated into clay brick to substitute Kaoline was suggested to fabricate the best quality of clay brick. Results of leaching test met the criteria with much less concentration of hazardous metals, even lead compound containing in the CRT funnel. To conclude, the use of CRT panel powder after crushing it to the proper size as an aggregate of concrete blocks or clay bricks could be one of the appropriate alternatives to recycle for CRT glass waste being generated drastically in a short term.  相似文献   

12.
The U.S. Environmental Protection Agency (EPA) has proposed regulations that would require corrective action (e.g., soil excavation and groundwater removal and treatment) at municipal solid waste landfills (MSWLFs) and hazardous waste treatment, storage, and disposal facilities (TSDFs). This paper presents an overview of the proposed corrective action regulations, and discusses their relationship to proposed or existing closure and post-closure care regulations. The paper then presents estimated corrective action cost curves for various MSWLF scenarios defined by landfill area, average waste thickness, and the presence or absence of a clay liner. The paper finally illustrates the economic benefits of sound closure and postclosure care by comparing estimated costs of corrective action to estimated costs of closure and postclosure care at MSWLFs.  相似文献   

13.
Recycling MSWI bottom and fly ash as raw materials for Portland cement   总被引:5,自引:0,他引:5  
Municipal solid waste incineration (MSWI) ash is rich in heavy metals and salts. The disposal of MSWI ash without proper treatment may cause serious environmental problems. Recently, the local cement industry in Taiwan has played an important role in the management of solid wastes because it can utilize various kinds of wastes as either fuels or raw materials. The objective of this study is to assess the possibility of MSWI ash reuse as a raw material for cement production. The ash was first washed with water and acid to remove the chlorides, which could cause serious corrosion in the cement kiln. Various amounts of pre-washed ash were added to replace the clay component of the raw materials for cement production. The allowable limits of chloride in the fly ash and bottom ash were found to be 1.75% and 3.50% respectively. The results indicate that cement production can be a feasible alternative for MSWI ash management. It is also evident that the addition of either fly ash or bottom ash did not have any effect on the compressive strength of the clinker. Cement products conformed to the Chinese National Standard (CNS) of Type II Portland cement with one exception, the setting time of the clinker was much longer.  相似文献   

14.
Contaminant transport through the clay liner and the underIying secondary leachate drain layer (SLDL) in landfills was studied through a laboratory test, and analysis method on the transport of K+ in a two-layer soil system. The soils used for this study were Ariake clay and the underlying layer, Shirasu soil from the Kyushu region of Japan, representing the clay liner material and SLDL material, respectively. The effective diffusion coefficients (De) of the selected target chemical species, potassium (K+) for the Ariake clay and Shirasu soil were back-calculated using a computer program, and it was found that values of De derived from this study were consistent with those previously published. The hypothesis that the mechanical dispersion process can be negligible has been proved to be reasonable based on both the observation that the predicted values fit the experimental data and the analyses of two dimensionless parameters. Parametric analysis showed the transport of K+ through the soils is controlled by advection-diffusion rather than diffusion only, whereas at low Darcy velocity (i.e. < or = 10(-9) m s(-1)), transport of K+ would be controlled by diffusion. The test results and parametric analysis may be applied in design of landfill liners and SLDLs, particularly in coastal areas.  相似文献   

15.
Stockpiled municipal waste incinerator bottom ash is frequently considered for utilization as a construction material. Two 360 kg lysimeter experiments were conducted to study percolation washing of contaminants from stockpiled MSW bottom ash. One lysimeter was leached with a concentrated sodium hydroxide solution, as a possible pre-treatment for improvement of the bottom ash characteristics prior to utilization, while the other was leached using distilled water. The lysimeter leachate was analysed, and at the end of the 2-year leaching period, the bottom ash from each lysimeter was subjected to several laboratory tests to assess the effect of the treatments. The laboratory tests showed that distilled water leachability of both treated ashes was an order of magnitude lower than that of fresh ash, but long-term contaminant leachability under acidic conditions had not changed. Although alkaline washing clearly resulted in greater contaminant removal than did distilled water washing, the chemical properties of the alkaline-leached bottom ash were not significantly different from those of the water-leached ash.  相似文献   

16.
When reusing or disposing of contaminated granular waste materials there is a need to evaluate how the contaminants will interact on the pathway soil–groundwater and the effect this interaction will have on the surrounding environment. While column testing can provide a closer approximation to field percolation conditions than batch testing, there is still a need to develop column testing procedures that consider the requirements of practical testing time frames. This study evaluates the effect of different column contact times (2.5, 5, and 16 h) on the release of inorganic constituents from bottom ash and demolition waste, two commonly reused granular materials. Leaching data for representative constituents of concern, such as copper, chromium, sulfate and chloride, as well as pH and electrical conductivity was compared for all different contact times studied.Results for the materials investigated in this study showed that variations in contact time have no significant effect on the release of the selected constituents and leaching parameters at low liquid to solid ratios. However, after a liquid to solid ratio of 1 L/kg, the effect is more noticeable, and higher contact times show lower pH values as well as a reduction in the release of constituents of concern from bottom ash. In the case of demolition waste, the variation of contact time did not have a strong effect on the leaching behavior.  相似文献   

17.
The incineration rate of municipal solid waste (MSW) has been increased because of difficulty in securing a proper disposal site for MSW in Korea. The advantage of incineration is reduction of the volume of waste; however, significant amounts of bottom ash and fly ash were generated in the incineration process. Their treatment has attracted growing interest because of the potential toxicity of hazardous heavy metals. Generally, heavy metals are less released from bottom ash than from fly ash. In this study the adsorption characteristics of heavy metals were investigated using various particle sizes of MSWI bottom ash. Since bottom ash has a broad particle size distribution, it was sieved to size classes of +20, -20, -48, -80, -100 mesh. Cation exchange capacity (CEC) was analyzed by the ammonium acetate method to evaluate the potential as an adsorbent. The CEC values and surface areas increase as the range of particle size becomes finer. The adsorption experiment was conducted using synthetic (Cu and Ni) and plating rinse water as a function of reaction time (10-180 min), liquid/solid ratio (2-100) and particle size (+20 to -100 mesh), respectively. The adsorption rate increased with decreasing particle size and with increasing liquid/solid ratio; however, the removal efficiency of Cu was higher than that of Ni. In the case of plating rinse water, the adsorption rate decreased sharply at high liquid/solid ratio, and it showed over 80% of adsorption rates for Cu and Ni at an initial pH of 3.  相似文献   

18.
Determining the appropriate criteria and designs for hazardous waste landfill covers has spawned much discussion within the environmental remediation arena. Very little reliable comparison of various technologies exists. Researchers at Los Alamos National Laboratory studied the relative hydrologic performance of four landfill cover designs—two capillary barrier designs, one modified EPA RCRA design, and one control cover. Monitoring the fate of natural precipitation for nearly four years showed that the covers with barrier layers more effectively reduced deep percolation than the control cover. Although none entirely eliminated deep percolation, the RCRA cover, incorporating a clay hydraulic barrier, most effectively controlled it. The two capillary barriers reduced deep percolation, but significant amounts were still produced. Over 90 percent of all percolation through the covers, and lateral flow within the covers, occurred during February through May each year, primarily as a result of snowmelt, early spring rains, and low evapotranspiration. The study also showed that gravel mulch surface treatments (70- to 80-percent ground cover) reduced runoff and erosion. Despite additional shrubs planted on one, the two plots receiving the gravel mulch treatments exhibited equally enhanced amounts of evapotranspiration.  相似文献   

19.
This study aims to characterize the leachate and to investigate the tropical climatic influence on leachate characteristics of lysimeter studies under different seasonal variations at KUET campus, Bangladesh. Three different situations of landfill were considered here as well as both the open dump lysimeter-A having a base liner and sanitary landfill lysimeter-B and C at two different types of cap liner were simulated. The leachate characteristics, leachate generation and climatic influence parameter had been continually monitored since June 2008 to May 2010, these periods cover both the dry and rainy season. The leachate generation had followed the rainfall pattern and the open dump lysimeter-A without top cover was recorded to have highest leachate generation. Moreover, the open dump lysimeter-A had lower total kjeldahl nitrogen (TKN), ammonia nitrogen (NH(4)-N) and TKN load, while both the COD concentration and load was higher compared with sanitary landfill lysimeter-B and C. In addition, sanitary landfill lysimeter-B, not only had lowest leachate generation, but also produces reasonable low COD concentration and load compared with open dump lysimeter-A. Result reveals that lysimeter operational mode had direct effect on leachate quality. Finally, it can be concluded that the knowledge of leachate quality will be useful in planning and providing remedial measures of proper liner system in sanitary landfill design and leachate treatment.  相似文献   

20.
Legislation from developed countries indicates that planting trees on containment landfills is generally forbidden. Concerns centre on the supposition that tree roots can penetrate into and through capping materials, and will thus compromise control of water ingress into waste, and allow the escape of landfill gas. An associated anxiety is that if roots penetrate a clay cap they could cause desiccation and cracking of the clay through excessive moisture abstraction. It is also considered that trees growing on the relatively shallow soil above a landfill cap could be especially prone to uprooting. However, a review of the world literature indicates that maximum depths achieved by tree roots are usually between 1–2 m. Almost 90% of a tree's roots may be found in the upper 0.6 m of soil. Tree roots are highly sensitive to environmental conditions and their downward penetration can be restricted by a number of soil factors including compaction, poor aeration and infertility. A detailed study of these factors indicates that the materials used for capping landfill sites, such as HDPE (high density polyethylene) and compacted clays, can provide an effective barrier to downward root growth. The available information also suggests that tree roots are extremely unlikely to be a primary cause of desiccation cracking in a clay cap owing to their inability to extract more than about one-quarter of the total moisture held in a clay of the density required to ensure a permeability of 1×10−9m s−1. Trees growing on landfill sites with a rootable soil depth of at least 1.5 m should be at no greater risk of windthrow than most forest trees on undisturbed sites. Methods are available to assess the likelihood of windthrow. In any event, windthrow should not cause disruption of a cap, due to the inability of tree roots to penetrate HDPE, or mineral materials compacted to a bulk density of 1.8 g cm−3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏