首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
The stack flue gases and the ashes in different units of two municipal solid waste incinerators (MSWIs) are sampled to investigate the characteristics of polybrominated diphenyl ethers (PBDEs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs), and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Bottom ashes (BA) exhibited much higher PBDD/F (8.11-52.2 pg TEQ/g) and PBDE contents (20.4-186 ng/g) than those of fly ashes (0.0932-2.02 pg TEQ/g and 0.332-25.5 ng/g), revealing that the PBDD/Fs and PBDEs in the feeding waste may not be completely destroyed. The PBDE concentrations/contents in the stack flue gases (26.1-109 ng/Nm3) and in the BA (20.4-186 ng/g) of the MSWIs could reach three orders higher than those in the atmosphere and reference soils. PBDE contributions to the environment from the stack flue gases or the reutilization of BA of MSWIs should not be ignored from the developing PBDE inventory.  相似文献   

2.
Chen HL  Shih TS  Huang PC  Hsieh CY  Lee CC 《Chemosphere》2006,64(4):666-671
This study aimed to evaluate serum polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) levels in electric-arc-furnace workers according to their corresponding occupational exposure. In addition, the ambient PCDD/Fs of the work environment were measured to provide additional support for the exposure and accumulation inside the electric arc furnace. The ambient PCDD/F concentrations inside the electric arc furnace were 1.557-1.917 pg-TEQ/Nm(3), 5-24 folds higher than those outside (0.080-0.385 pg-TEQ/N m(3)). In addition, higher average serum levels were measured in the workers with high occupational dioxin exposure (24.0 pg WHO-TEQ/g lipid) than in those with lower occupational dioxin exposure (13.8 pg WHO-TEQ/g lipid). Higher PCDFs/PCDDs ratios were found in serum samples from high-exposure groups than in low-exposure groups. The higher ratio of PCDFs/PCDDs was also found in ambient samples consistent with other metallurgical processes reported previously. Our results suggest that PCDD/Fs exposure exits in the smelting process of electric arc furnace, and the occupational hygiene should be taken more seriously concern in that workplace.  相似文献   

3.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

4.
A total of 156 fish composite samples were collected from five areas of the Baltic Sea and from three lakes and analysed for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs) and polybrominated diphenyl ethers (PBDEs). The European Union's maximum permissible level for PCDD/Fs, 4 pg WHO-TEQ/g fresh weight (fw), was exceeded in salmon, river lamprey and Baltic herring. In other species from the Baltic Sea, the 90th percentile was 3.42 pg WHO(PCDD/F)-TEQ/g fw. In the lake fish, the concentrations of PCDD/Fs, PCBs and PCNs were only 29-46% of those in the same species caught from the Baltic Sea, whereas the concentrations of PBDEs in the lake fish were as high as in the Baltic Sea fish. Dioxin-like PCBs contributed to the total dioxin-like toxicity of PCBs and PCDD/Fs by 49+/-12% in all the analysed samples.  相似文献   

5.
In this study we investigated occurrences and distribution patterns of dioxin-related compounds (DRCs) such as polybrominated dibenzo-p-dioxins/dibenzofurans (PBDD/Fs), polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), monobromo-polychlorinated dibenzo-p-dioxins/dibenzofurans (MoBPCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) in marine surface sediments collected from the coastal waters of Hong Kong and Korea. In most sampling sites, concentrations of PCDDs were the highest, followed by DL-PCBs, PCDFs, PBDFs, PBDDs, MoBPCDDs and MoBPCDFs in this order. Levels of PBDD/Fs were generally 1-2 orders of magnitude lower than chlorinated analogues. Levels of PCDDs are higher than PCDFs in Hong Kong while levels of PBDFs are higher than PBDDs in Korea (p < 0.05). Report of PBDD/Fs and MoBPCDD/Fs in sediments from East Asian countries is novel and original. Environmental levels of PBDD/Fs are supposed to start increasing in accordance with rising production, use and disposal of brominated flame retardants (BFRs) and recycling processes of e-waste in Asian developing countries.  相似文献   

6.
Estonia still has no waste incineration facilities, which would act as substantial sources of dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) pollution. As landfill fires may serve as sources of dioxins, we focused on the concentrations of PCDD and PCDF in soil samples taken in the vicinity of the landfill located at south-east Estonia in the course of our inventory. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were studied in five soil samples taken in the vicinity of the Laguja landfill in south-east Estonia. The four soil samples were taken in southern, eastern, western and northern parts not further than 300 m from the landfill, and one sample was taken at the distance of 3 km from the landfill. The PCDD/F concentrations in all soil samples were at background level (0.64-2.33 pg I-TEQ WHO/g dry weight). To maintain this situation, the administrator of the landfill must avoid landfill fires, which are one of the reasons for the generation of dioxins and furans.  相似文献   

7.
Concurrent measurements of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs) in different size fractions of atmospheric particulate matter are presented for a winter and a summer sampling period. The PCDD/Fs and PAHs were primarily associated with particles of <1.35 μm aerodynamic diameter. The particle size distributions were similar for the compounds within each substance group and, surprisingly, also between the PCDD/Fs and PAHs. Changes in the particle size distribution of particle mass were reflected in the particle size distributions of the PCDD/Fs and PAHs.The data were employed to identify those particle size fractions dominating the wet and dry particle bound deposition of PCDD/Fs and PAHs and, furthermore, to assess the relative contributions of wet and dry deposition to the total particle bound deposition fluxes. The calculations indicate that coarse particles contribute most to the dry deposition while, in contrast, the wet deposition of the PCDD/Fs and PAHs is dominated by fine particles. Furthermore, it is estimated that in Bayreuth wet deposition dominates the total particle bound deposition of PCDD/Fs and PAHs.  相似文献   

8.
Wang SL  Lin CY  Guo YL  Lin LY  Chou WL  Chang LW 《Chemosphere》2004,54(10):1459-1473
Polychlorinated dibenzo-p-dioxins, dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) are recognized environmental endocrine disruptors, which are environmentally persistent and may bio-accumulate in human bodies. Pregnant and nursing women may pass these pollutants to their babies both trans-placentally and lactationally. We measured and examined correlations of the levels of PCDD/Fs and PCBs in perinatal venous serum, placenta, umbilical-cord serum (representing prenatal exposure), and breast milk (postnatal exposure). Subjects included pregnant women without clinical complication between the ages of 25 and 35, who delivered their babies during 2000.12.01 and 2001.11.30 in central Taiwan. A total of 20 participants were randomly selected from those provided the four biological specimens for analysis of 17 PCDD/Fs, and 12 dioxin-like PCBs and six indicator PCBs using high-resolution gas chromatography/high-resolution mass spectrometry. Higher PCDD/F levels were found in placenta (10.3 TEq-pg/g lipid) and venous serum (9.1 TEq-pg/g lipid) compared to those in breast milk (7.6 TEq-pg/g lipid). Pearson and Spearman correlation analyses showed well association of PCDD/F and PCB levels between different specimens. The total dioxin/PCB level in milk, venous and cord serum can be well predicted by that in placenta through regression functions. This first study of multi-specimen correlation further established rather consistent ratios of these chemical concentrations in various specimens relative to those in venous serum.  相似文献   

9.
Atmospheric deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was investigated at four locations, namely at Yuancun, Wushan, Haizhu and Changban in Guangzhou City, Guangdong Province. The annual deposition fluxes of tetra- to octa-CDD/Fs (total PCDD/Fs) were found to range from 170 to 3000 (mean 1500) pg m−2 day−1, and the fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners ranged from 2.1 to 41 (mean 20) pg WHO-TEQ m−2 day−1 at Wushan. The average deposition fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners in rainy season were found to be 37, 27 and 28 pg WHO-TEQ m−2 day−1 at Yuancun, Haizhu and Changban, respectively, and the PCDD/F deposition fluxes behaved obviously higher in rainy season than in dry season. Results from regression analysis showed that number of rainy days, the amount of wet precipitation, PCDD/F concentrations in particles and organic carbon content played important roles in the variation of PCDD/F deposition fluxes. Monthly average temperatures change little over the year. Therefore, it only played a minor role in monthly variation of PCDD/F deposition fluxes. Particle deposition fluxes were generally not considered as the factor that could cause the differences in PCDD/F deposition fluxes between rainy and dry season, but were found to be related with PCDD/F deposition fluxes in rainy season or dry season. It was found that the profiles of PCDD/F homologs or congeners in the samples were the same either spatially or temporally, indicating that the PCDD/F emission sources were similar to one another. The similarities in PCDD/F homolog patterns and the differences in deposition fluxes between samples collected from heavy-traffic roadside and nearby residence house roof indicated that vehicle exhaust might be an important source for PCDD/F in Guangzhou. PCDD/F concentrations and profiles of PCDD/F homologs in atmospheric deposition were compared with those in both total suspended particles in air and soils, and conclusions indicated that atmospheric deposition possibly tended to remove lower-chlorinated DD/Fs from air and was one of sources for PCDD/Fs in soils.  相似文献   

10.
A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes approximately 1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 10(7) yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octa-chlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Q(f)) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Q(f)/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases < or = 90%.  相似文献   

11.
Haglund P 《Ambio》2007,36(6):467-474
This review provides a summary of methods for treating soils contaminated with polychlorinated aromatic compounds, especially polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Unlike many other soil pollutants, PCDD/Fs bind tightly to the soil, which severely reduces the efficiency of most aqueous treatment procedures and leaves few realistic alternatives besides the traditional containment techniques (landfill, solidification/stabilization, and in situ vitrification). Incineration has long been, and still is, the most efficient destruction technique, with a removal efficiency of >99.9999%. However, supercritical water oxidation, base-catalyzed decomposition, steam distillation, and various extraction techniques, such as solvent and liquefied gas and subcritical water extraction, may provide removal efficiencies of >95%. Many of the alternative techniques are expected to be cheaper than incineration and may therefore be attractive for moderately polluted soils. However, some of them are at an early stage of development and need to be further tested before their true potential can be assessed.  相似文献   

12.
A clean-up method for polybrominated dibenzo-p-dioxins (PBDDs), dibenzofurans (PBDFs) and diphenyl ethers (PBDEs) was modified using combinations of multi-layered silica gel, Florisil and active carbon columns. By using active carbon column chromatography in the final procedure, PBDEs were well separated from PBDD/Fs in an elution test with reference standards. We report the application of this method to sediment samples taken from industrialized areas in Japan. These sediments contained PBDEs ranging in concentration from 13 to 2394 pg/g, dry wt. PBDEs did not interfere with the quantification of PBDD/Fs. In addition, PBDEs found in the PBDD/F fraction did not interfere with the identification of PBDFs using the HRGC/HRMS separation method. Some 2,3,7,8-tetra- to hexabrominated dioxins and furans were also detected in the sediment samples.  相似文献   

13.
Congener-specific analyses of 7 polychlorinated dibenzo-p-dioxins (PCDDs), 10 polychlorinated dibenzofurans (PCDFs) and 4 non-ortho (coplanar) polychlorinated biphenyls (cPCBs) were performed on 35 samples of commercial long-life pasteurised cows' milk issued from eight different brands available in Walloon supermarkets (Belgium). The observed congener profile was characteristic of milk samples issued from industrialised countries with good inter and intra-brand reproducibility's. The PCDDs to PCDFs ratio was equal to 1.8 in concentration. The toxic equivalent (TEQ based on WHO-TEF) value for PCDD/Fs in all analysed milks was 1.09+/-0.30 pg TEQ/g fat (range 0.86-1.59), which is below the recommended EU non-commercialisation threshold value of 3 pg TEQ PCDD/Fs/g of milk fat. The mean TEQ value including cPCBs was 2.23+/-0.55 pg TEQ/g fat. These PCBs actually contributed for 49+/-8.6% of the total TEQ. Among PCDD/Fs and cPCBs, tetrachloro dibenzo-p-dioxin (TCDD), pentachloro dibenzo-p-dioxin (PeCDD), pentachloro dibenzofurans (PeCDFs) and 3,3',4,4',5-pentachloro biphenyl (PCB-126) were the most important contributors to the TEQ. Estimated daily intake (EDI) due to consumption of such milks was 0.34 pg TEQ/kg of body weight/day for PCDD/Fs and 0.69 pg TEQ/kg of body weight/day when cPCBs were included.  相似文献   

14.
Hu SW  ChangChien GP  Chan CC 《Chemosphere》2004,55(4):611-620
This study monitored ambient air concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in three municipal waste incineration plants. Blood PCDD/Fs levels of 133 workers randomly selected from these plants were also measured. The associations between workers' blood PCDD/Fs concentrations and occupational exposures to PCDD/Fs were assessed. Means of air PCDD/Fs levels ranged from 0.08 to 3.01 pg/m3 in international toxic equivalents (I-TEQ). The geometric means of blood PCDD/Fs concentrations were 14.6, 15.8, 19.1 pg/g lipid in World Health Organization (WHO) TEQ, respectively, for workers from three plants. Air levels of total I-TEQ and all congeners, except 2,3,7,8-tetrachlorinated dibenzo-p-dioxin (TeCDD) and 1,2,3,4,7,8,9-heptachlorinated dibenzofuran (HpCDF), were significantly higher in plant B. However, blood concentrations of 2,3,7,8-TeCDD, 1,2,3,7,8-PeCDD, 2,3,7,8-TeCDF, 1,2,3,7,8-PeCDF and 1,2,3,4,7,8,9-HpCDF were significantly elevated in plant C workers. Although job contents, duration of employment and time spent in certain location were significantly different among incineration plants, they were not significantly associated with blood concentrations of any congener. Furthermore, results of the multiple regression analysis that assessed important occupational factors simultaneously and adjusted for potential confounders, showed significant associations between four congeners and incineration plant or job contents. However, the results were limited by small R-squares of the regression models. In conclusion, blood concentrations of several PCDD/Fs congeners were significantly different among three incineration plants. The differences were not explained by the discrepancy in job contents, duration of employment, and time activity in these plants.  相似文献   

15.
This study monitored particle size-dependent variations in atmospheric polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Two gas/particle partitioning models, the subcooled liquid vapor pressure (P(L)(0)) and the octanol-air partition coefficient (K(OA)) model, were applied to each particle sizes. The regression coefficients of each fraction against the gas/particle partition coefficient (K(P)) were similar for separated particles within the same sample set but differed for particles collected during different periods. Gas/particle partitioning calculated from the integral of fractions was similar to that of size-segregated particles and previously measured bulk values. Despite the different behaviors and production mechanisms of atmospheric particles of different sizes, PCDD/F partitioning of each size range was controlled by meteorological conditions such as atmospheric temperature, O(3) and UV, which reflects no source related with certain particle size ranges but mixed urban sources within this city. Our observations emphasize that when assessing environmental and health effects, the movement of PCDD/Fs in air should be considered in conjunction with particle size in addition to the bulk aerosol.  相似文献   

16.
Extensive forest fires occurred in northern Alberta, Canada, in 1998. Polynuclear aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were studied following these forest fires in order to explore natural and anthropogenic influences on the affected forest fire area. Specifically, concentrations and profiles of these compounds were determined in sediment samples. A predominance of alkylated PAH derivatives over parent PAHs were observed at the burned and reference sites. Naturally dervied PAHs were abundant at all sites. A high proportion and concentration of retene was observed at the totally burned site and indicates some inputs from forest fires. Very low concentrations of PCDD/Fs and PCBs were observed at all sites, and the profiles were very similar. This likely reflects common atmospheric contributing sources to the study area.  相似文献   

17.
The atmospheric fate of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was simulated for the year 2000 in North America using a SMOKE/CMAQ-based chemical transport model that was modified for this purpose. The 1999 USEPA emission inventories of PCDD/Fs and criteria pollutants were used. The 1995 Canadian emission inventory of criteria pollutants and the 1995 Canadian area source emissions for PCDD/Fs were used with the 2000 Canadian point source emissions. Modifications to CMAQ involved coupling it with dual organic matter (OM) absorption and black carbon (BC) adsorption models to calculate PCDD/F gas–particle partitioning. The model satisfactorily reproduced the particle bound fractions at all rural sites for which there were measured data and across the whole domain, the modeled vs. measured differences in particle bound fractions were less than 20% for nearly all congeners. The model predicted ambient air PCDD/F concentrations were also consistent with measurements. Simulated deposition fluxes were within 58% of direct measurements. PCDD/F atmospheric depositions to each of the Great Lakes were estimated for the year 2000. The results indicate that approximately 76% of the total deposition of PCDD/Fs to the Great Lakes (in W-TEQ, or toxic equivalent units as defined by the World Health Organization) is attributed to PCDD/Fs absorbed into OM in aerosol. For all of the lakes, more than 92% of all deposition is particle phase wet deposition and only 5–8% is particle phase dry deposition. Wet deposition from the gas phase is negligible. Of the 17 toxic PCDD/F congeners, the Cl4–5DD/F compounds contribute approximately 70% to the total atmospheric deposition to the Great Lakes. The seasonal changes in the PCDD/F deposition flux track variations in ambient temperature.  相似文献   

18.
PCBs (as Aroclor concentrations) have been extensively examined in fish along the Hudson River, but other xenobiotic chemicals in fish have had limited assessment. This study determined concentrations and congener distributions of polybrominated diphenyl ethers (PBDEs), polybrominated and polychlorinated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs and PCDD/Fs), and polychlorinated biphenyls (PCBs) in smallmouth bass and striped bass taken from a 385 km reach of the Hudson River. Concentrations of PBDEs and PCBs in smallmouth bass, and PCBs in striped bass, were positively related to human uses of the compounds in the basin. Generally low levels of PCDD/Fs were found. One striped bass, however, contained elevated 2,3,7,8-TCDD, indicating exposure to a known source in the adjacent Newark Bay-Passaic River basin. PBDDs were generally below detection. PBDFs were present in four of 18 smallmouth bass, but were not detected in striped bass. Dioxin-like PCBs contribute most to 2,3,7,8-TCDD toxic equivalents in 29 of 30 samples.  相似文献   

19.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and certain dioxin-like polychlorinated biphenyls (dl-PCBs) are a family of chemically-related lipophilic compounds characterized by similar toxicity. Due to their properties they are universally distributed in the environment and classified as persistent organic pollutants (POPs). From most of studies carried out to evaluate human dietary intake, milk and dairy products result as a major contributors of PCDD/Fs uptake. Of course the main source of milk contamination is animal feeds. Lactating ruminants, cows included, transfer these compounds to the food chain by ingestion of contaminated vegetables or soil. Their resistance to degradation and a high lipophilicity means that PCDD/Fs and dl-PCBs may be accumulated into fat tissues from which they are transferred to milk during lactation period.Seventy-nine cows milk samples, collected in the monitoring plan 2008, were analyzed for PCDD/Fs and dl-PCBs. Eleven milk samples were non-compliant corresponding to five breeding livestock located in Caserta province. The distribution of PCDD/Fs and dl-PCBs congeners in these samples was examined in order to determine the likely sources of dioxins. The results show that the congener profile is characterized by a prevalence of PCDFs in respect of PCDDs, that represents the typical pattern of thermal origin contamination.  相似文献   

20.
The contaminated air with burning plastic floor and electronic scrap was monitored with semipermeable membrane devices (SPMDs) and fresh unpolluted spruce needles at the same time for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs). It was found that there were more polychlorinated dibenzofurans (PCDFs) than polychlorinated dibenzo-p-dioxins (PCDDs) collected from contaminated air. The total amounts of PCBs were much higher than that of PCDD/Fs, but the contribution of them to the WHO-TEQ was less than that of PCDD/Fs. Triolein-containing SPMDs can absorb much more PCDD/Fs and PCBs than spruce needles when they were exposed in contaminated air simultaneously. The logarithm of the concentrations of PCDD/Fs and PCBs in SPMDs and in spruce needles at the same sampling time exhibited a significant linear correlation, the correlation coefficients were larger than 0.86 for PCDD/Fs and 0.92 for PCBs. SPMDs and spruce needles are effective passive air sampler for PCDD/Fs and PCBs. SPMDs and spruce needles can complement each other in passive air sampling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号