首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 68 毫秒
1.
Atmospheric BTX and polyaromatic hydrocarbons in Rio de Janeiro, Brazil   总被引:1,自引:0,他引:1  
Polycyclic aromatic and monoaromatic (benzene, toluene and xylene, or BTX) hydrocarbons were monitored in Rio de Janeiro, Brazil, during the summer of 1998/1999. The levels of these aromatic chemicals decreased with distance from main roads, indicating mobile sources are the main pollutant emitters in this Latin American city. Benzo[ghi]perylene/indeno[1,2,3-cd]pyrene and benzene/toluene ratios corroborate this idea. However, higher benzene/toluene ratios at one of the major access routes into the city suggest pollutant inputs from a nearby refinery. Literature data were reviewed in order to outline differences and similarities among sources and levels of aromatic pollutants in large urban agglomerations worldwide. Concentrations of benzo[a]pyrene and benzene, which are well-known carcinogenic chemicals, were relatively low in Rio de Janeiro. This fact was attributed to specific atmospheric conditions during the tropical summer and differences in vehicle fuel composition.  相似文献   

2.
Highly portable, sensitive, and selective passive air samplers were used to investigate ambient volatile organic compound (VOC) levels at multiple sampling sites in an industrial city, Fuji, Japan. We determined the spatial distributions of 27 species of VOCs in three campaigns: Mar (cold season), May (warm season), and Nov (mild season) of 2004. In all campaigns, toluene (geometric mean concentration, 14.0microg/m3) was the most abundant VOC, followed by acetaldehyde (4.76microg/m3), and formaldehyde (2.58microg/m3). The spatial distributions for certain VOCs showed characteristic patterns: high concentrations of benzene and formaldehyde were typically found along major roads, whereas high concentrations of toluene and tetrachloroethylene (PCE) were usually found near factories. The spatial distribution of PCE observed was extremely consistent with the diffusion pattern calculated from Pollutant Release and Transfer Register data and meteorological data, indicated that passive air samplers are useful for determining the sources and distributions of ambient VOCs.  相似文献   

3.
A sampling program was conducted to determine the ambient VOC levels in the city of Izmir, Turkey during daytime and overnight periods between mid-August and mid-September 1998. Sampling sites were selected at high-density traffic roads and junctions far from stationary VOC sources. Samples were analyzed for benzene, toluene, m, p-xylene and o-xylene (BTX), alkylbenzenes (ethylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene), n-hexane and, n-heptane. Results were compared with similar data from other cities around the world and for probable health dangers and sources of the compounds. Results of this study indicated that Izmir has rather high ambient BTX concentrations compared to many polluted cities in the world. Toluene was the most abundant VOC in Izmir air and was followed by xylenes, benzene and alkylbenzenes, respectively. All were strongly dependent on the expected daily variations of traffic flow in the city. The concentrations of other VOCs correlated well with benzene concentration at most sampling sites, excluding Gumuldur station indicating that ambient VOC levels were mainly affected by motor vehicle emissions. The toluene-to-benzene ratios for urban and non-urban sites were in good agreement with previously reported values, indicating a good relationship between the motor vehicle emissions and ambient VOC levels.  相似文献   

4.
Experiments were conducted on a 4-cylinder direct-injection diesel engine using ultralow sulfur diesel blended with biodiesel and ethanol to investigate the gaseous emissions of the engine under five engine loads at the maximum torque engine speed of 1800 rev min?1. Four biodiesel blended fuels and four ethanol blended fuels with oxygen concentrations of 2%, 4%, 6% and 8% were used. With the increase of oxygen content in the blended fuels, the brake thermal efficiency improves slightly.For the diesel-biodiesel fuels, the brake specific HC and CO emissions decrease while the brake specific NOx and NO2 emissions increase. The emissions of formaldehyde, 1,3-butadiene, toluene, xylene and overall BTX (benzene, toluene, xylene) in general decrease, however, acetaldehyde and benzene emissions increase. For the diesel-ethanol fuels, the brake specific HC and CO emissions increase significantly at low engine load, NOx emission decreases at low engine load but increases at high engine load. The emissions of benzene and BTX vary with engine load and ethanol content. Similar to the biodiesel-diesel fuels, the formaldehyde, 1,3-butadiene, toluene and xylene emissions decrease while the acetaldehyde and NO2 emissions increase. Despite having the same oxygen contents in the blended fuels, there are significant differences in the gaseous emissions between the biodiesel-diesel blends and the ethanol-diesel blends.  相似文献   

5.
Select volatile organic compounds (VOCs) were measured in the vicinity of a petroleum refinery and related operations in South Philadelphia, Pennsylvania, USA, using passive air sampling and laboratory analysis methods. Two-week, time-integrated samplers were deployed at 17 sites, which were aggregated into five site groups of varying distances from the refinery. Benzene, toluene, ethylbenzene, and xylene isomers (BTEX) and styrene concentrations were higher near the refinery’s fenceline than for groups at the refinery’s south edge, mid-distance, and farther removed locations. The near fenceline group was significantly higher than the refinery’s north edge group for benzene and toluene but not for ethylbenzene or xylene isomers; styrene was lower at the near fenceline group versus the north edge group. For BTEX and styrene, the magnitude of estimated differences generally increased when proceeding through groups ever farther away from the petroleum refining. Perchloroethylene results were not suggestive of an influence from refining. These results suggest that emissions from the refinery complex contribute to higher concentrations of BTEX species and styrene in the vicinity of the plant, with this influence declining as distance from the petroleum refining increases.

Implications: Passive sampling methodology for VOCs as discussed here is employed in recently enacted U.S. Environmental Protection Agency Methods 325A/B for determination of benzene concentrations at refinery fenceline locations. Spatial gradients of VOC concentration near the refinery fenceline were discerned in an area containing traffic and other VOC-related sources. Though limited, these findings can be useful in application of the method at such facilities to ascertain source influence.  相似文献   


6.
Stenotrophomonas maltophilia T3-c, isolated from a biofilter for the removal of benzene, toluene, ethylbenzene, and xylene (BTEX), could grow in a mineral salt medium containing toluene, benzene, or ethylbenzene as the sole source of carbon. The effect of environmental factors such as initial toluene mass, medium pH, and temperature on the degradation rate of toluene was investigated. The cosubstrate interactions in the BTEX mixture by the isolate were also studied. Within the range of initial toluene mass (from 23 to 70 pmol), an increased substrate concentration increased the specific degradation of toluene by S. maltophilia T3-c. The toluene degradation activity of S. maltophilia T3-c could be maintained at a broad pH range from 5 to 8. The rates at 20 and 40 degrees C were 43 and 83%, respectively, of the rate at 30 degrees C. The specific degradation rates of toluene, benzene, and ethylbenzene by strain T3-c were 2.38, 4.25, and 2.06 micromol/g-DCW/hr. While xylene could not be utilized as a growth substrate by S. maltophilia T3-c, the presence of toluene resulted in the cometabolic degradation of xylene. The specific degradation rate of toluene was increased by the presence of benzene, ethylbenzene, or xylene in binary mixtures. The presence of toluene or xylene in binary mixtures with benzene increased the specific degradation rate of benzene. The presence of ethylbenzene in binary mixtures with benzene inhibited benzene degradation. The presence of more than three kinds of substrates inhibited the specific degradation rate of benzene. All BTEX mixtures, except tri-mixtures of benzene, ethylbenzene, and xylene or mixtures of all four substrates, had little effect on the degradation of ethylbenzene by S. maltophilia T3-c. The utilization preference of the substrates by S. maltophilia T3-c was as follows: ethylbenzene was degraded fastest, followed by toluene and benzene. However, the specific degradation rates of substrates, in order, were benzene, toluene, and ethylbenzene.  相似文献   

7.
Two measurement campaigns of volatile organic compounds (VOC) were carried out in the industrial city of Dunkerque, using Radiello passive samplers during winter (16–23 January) and summer (6–13 June) 2007. 174 compounds were identified belonging to six chemical families. Classifying sampling sites with similar chemical profiles by hierarchical ascending classification resulted in 4 groups that reflected the influence of the main industrial and urban sources of pollution. Also, the BTEX (Benzene, Toluene, Ethylbenzene and Xylenes) quantification allowed us to map their levels of concentration. Benzene and toluene (BT) showed high concentrations in Northern Dunkerque reflecting the influence of two industrial plants. Differences among spatial distributions of the BT concentrations over contrasted meteorological conditions were also observed. An atypical ratio of T/B in the summer samples led us to investigate the BTEX origins shedding light on the contribution of pollutants transported across various zones of VOC emissions situated in Europe.  相似文献   

8.
This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks. OVM concentrations were corrected for ambient pressure to account for higher elevation. Precise results (< 5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs (> or = 77% RSD for 2-day samples) with better precision for longer sampling periods. Comparison of Ogawa NO2 samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer. For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements. The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs. However, except for toluene, OVM BTEX measurements generally exceeded their continuous counterparts with a mean bias of 5-10%. Although interpretation of the study results was limited due to small sample sizes, diffusion barrier influences caused by shelters that housed OVMs and differences in sampling heights between OVMs and auto-GC inlet may explain the overestimation.  相似文献   

9.
A combined monitoring and dispersion modelling methodology was applied for assessing air quality at three different levels of proximity to the selected service station: (I) next to the fuel pumps, (II) in the surrounding environment, and (III) in the background. Continuous monitoring and passive sampling were used for achieving high temporal and spatial resolution, respectively. A Gaussian dispersion model (CALINE4) was used for assessing the road traffic contribution to the local concentrations under different meteorological conditions. It was established that Stage 2 vapour recovery reduces BTX concentrations not only near the pumps, but also in their surrounding environment. However, there is evidence that the efficiency of the system is wind speed dependent. The modelling simulation of the worst case wind scenario revealed the significance of local traffic emissions. It was shown that the traffic contribution even from a single road in the vicinity of the station can, under certain conditions, be higher than the contribution of the station itself to the local BTX levels. Finally, after comparison with previous studies, the concentrations measured near the service station (which was situated in a rural environment) appear to be lower than those observed in busy street canyons in city centres. It can be concluded, although Stage 2 recovery system effectively reduces working VOC losses in service stations, that it will only have a limited positive impact on local air quality if the service station is located in a heavily polluted area.  相似文献   

10.
Atmospheric concentrations of benzene, toluene, ethylbenzene, and xylenes (o-xylene and m,p-xylene) were assessed in the Tricity area (Gdańsk-Sopot-Gdynia, Poland) with the use of two types of passive samplers: permeation (homemade passive samplers) and diffusive (Radiello and Orsa 5). Samples were collected during 2008 at selected sites in the Tricity area at monitoring stations belonging to the agency of Regional Air Quality Monitoring Foundation. The field study was conducted to compare the performance of these two different types of passive samplers. A statistical approach was formulated, and the experimental data were evaluated using the paired t test, Wilcoxon signed rank-sum test, and Friedman analysis of variance. All the statistical results confirm the hypothesis that the differences between the performances of the three sampling devices are highly significant. Despite the fact that data obtained with the homemade passive sampler indicated that the results were higher compared with those for the Radiello and Orsa 5 diffusive samplers, the authors note that all differences between the homemade permeation sampler and the Radiello and Orsa 5 diffusive samplers are positive.  相似文献   

11.
Abstract

This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks. OVM concentrations were corrected for ambient pressure to account for higher elevation. Precise results (<5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs (≥7% RSD for 2-day samples) with better precision for longer sampling periods. Comparison of Ogawa NO2 samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer. For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements. The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs.  相似文献   

12.
BACKGROUND, AIM AND SCOPE: All across Europe, people live and work in indoor environments. On average, people spend around 90% of their time indoors (homes, workplaces, cars and public transport means, etc.) and are exposed to a complex mixture of pollutants at concentration levels that are often several times higher than outdoors. These pollutants are emitted by different sources indoors and outdoors and include volatile organic compounds (VOCs), carbonyls (aldehydes and ketones) and other chemical substances often adsorbed on particles. Moreover, legal obligations opposed by legislations, such as the European Union's General Product Safety Directive (GPSD) and Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), increasingly require detailed understanding of where and how chemical substances are used throughout their life-cycle and require better characterisation of their emissions and exposure. This information is essential to be able to control emissions from sources aiming at a reduction of adverse health effects. Scientifically sound human risk assessment procedures based on qualitative and quantitative human exposure information allows a better characterisation of population exposures to chemical substances. In this context, the current paper compares inhalation exposures to three health-based EU priority substances, i.e. benzene, formaldehyde and acetaldehyde. MATERIALS AND METHODS: Distributions of urban population inhalation exposures, indoor and outdoor concentrations were created on the basis of measured AIRMEX data in 12 European cities and compared to results from existing European population exposure studies published within the scientific literature. By pooling all EU city personal exposure, indoor and outdoor concentration means, representative EU city cumulative frequency distributions were created. Population exposures were modelled with a microenvironment model using the time spent and concentrations in four microenvironments, i.e. indoors at home and at work, outdoors at work and in transit, as input parameters. Pooled EU city inhalation exposures were compared to modelled population exposures. The contributions of these microenvironments to the total daily inhalation exposure of formaldehyde, benzene and acetaldehyde were estimated. Inhalation exposures were compared to the EU annual ambient benzene air quality guideline (5 microg/m3-to be met by 2010) and the recommended (based on the INDEX project) 30-min average formaldehyde limit value (30 microg/m3). RESULTS: Indoor inhalation exposure contributions are much higher compared to the outdoor or in-transit microenvironment contributions, accounting for almost 99% in the case of formaldehyde. The highest in-transit exposure contribution was found for benzene; 29.4% of the total inhalation exposure contribution. Comparing the pooled AIRMEX EU city inhalation exposures with the modelled exposures, benzene, formaldehyde and acetaldehyde exposures are 5.1, 17.3 and 11.8 microg/m3 vs. 5.1, 20.1 and 10.2 microg/m3, respectively. Together with the fact that a dominating fraction of time is spent indoors (>90%), the total inhalation exposure is mostly driven by the time spent indoors. DISCUSSION: The approach used in this paper faced three challenges concerning exposure and time-activity data, comparability and scarce or missing in-transit data inducing careful interpretation of the results. The results obtained by AIRMEX underline that many European urban populations are still exposed to elevated levels of benzene and formaldehyde in the inhaled air. It is still likely that the annual ambient benzene air quality guideline of 5 microg/m3 in the EU and recommended formaldehyde 30-min average limit value of 30 microg/m3 are exceeded by a substantial part of populations living in urban areas. Considering multimedia and multi-pathway exposure to acetaldehyde, the biggest exposure contribution was found to be related to dietary behaviour rather than to inhalation. CONCLUSIONS: In the present study, inhalation exposures of urban populations were assessed on the basis of novel and existing exposure data. The indoor residential microenvironment contributed most to the total daily urban population inhalation exposure. The results presented in this paper suggest that a significant part of the populations living in European cities exceed the annual ambient benzene air quality guideline of 5 microg/m3 in the EU and recommended (INDEX project) formaldehyde 30-min average limit value of 30 microg/m3. RECOMMENDATIONS AND PERSPECTIVES: To reduce exposures and consequent health effects, adequate measures must be taken to diminish emissions from sources such as materials and products that especially emit benzene and formaldehyde in indoor air. In parallel, measures can be taken aiming at reducing the outdoor pollution contribution indoors. Besides emission reduction, mechanisms to effectively monitor and manage the indoor air quality should be established. These mechanisms could be developed by setting up appropriate EU indoor air guidelines.  相似文献   

13.
The atmospheric concentrations of benzene, toluene, ethylbenzene and isomeric xylenes (BTEX) in a medium-sized town (S. Maria Capua Vetere, about 32000 inhabitants, Southern Italy) have been determined during working days and weekends in 2006. The procedure used was 24h passive adsorption by samplers distributed throughout the town followed by GC/MS analysis. On a yearly base, the arithmetic mean benzene concentrations were above the limit required by the 2000/69/CE European Directive. The Pearson correlation coefficients of the 24h geometric mean BTEX concentrations were indicative of stationary sources of toluene located in a well circumscribed area of the urban territory, active only during the working days and not officially recognized. The results highlight the effectiveness of the statistical approach used in this study for the identification of pollutant sources.  相似文献   

14.
We initiated the PETER (pedestrian environmental traffic pollutant exposure research) project to investigate pedestrians' exposure to traffic related atmospheric pollutants, based on data obtained with the collaboration of selected categories of pedestrian urban workers. We investigated relations between roadside personal exposure levels of volatile aromatic hydrocarbons (including benzene) and particulate matter <10 microm (PM10) among traffic police (n = 126) and parking wardens (n = 50) working in downtown Bologna, Italy. Data were collected from workshifts throughout four 1-week periods in different seasons of 2000-2001. For benzene and PM10, comparisons were made with measurements by fixed monitoring stations, and influence of localized traffic intensity and meteorological parameters was examined. Roadside personal exposure to benzene correlated more strongly with other volatile aromatic hydrocarbons (toluene, xylenes and ethylbenzene) than with PM10. Benzene and PM10 personal exposure levels were higher than fixed monitoring station values (both p<0.0001). At multivariate analysis, benzene and PM10 data from fixed monitoring stations both correlated with meteorological variables, and were also influenced by localized traffic intensity. Plausibly because of the downtown canyon-like streets, weather conditions (during a period of drought) only marginally affected benzene personal exposure, and moderately affected PM10 personal exposure. These findings reinforce the concept that urban atmospheric pollution data from fixed air monitoring stations cannot automatically be taken as indications of roadside exposures.  相似文献   

15.
The exposure to benzene, toluene, xylenes and total hydrocarbons among 25 individuals exposed to exhaust from a snowmobile equipped with a two-stroke engine has been evaluated. Sampling was performed by pumped and diffusive sampling in parallel. There was a relatively bad agreement between the two air-sampling methods. The bad agreement can in part be explained by back diffusion of the substances from the samplers, a high face velocity, and deposition of droplets of unburned gasoline onto or in the vicinity of the samplers.

The levels of benzene ranged from not detectable (0.01 mg m−3) to 2.5 mg m−3. For toluene, xylenes and total hydrocarbons the exposure was 0.10–12.0, 0.05–13.0 and 0.90–273 mg m−3 respectively. The result from two measurements on individuals travelling on an open sleigh at the rear of the vehicle indicated higher levels of benzene, 0.7–0.8 mg m−3. Children are often riding as a passenger on a sledge and may thus have a higher exposure than their parents. This study indicates that spare time driving a snowmobile may cause a considerable exposure to benzene. Using a four-stroke engine equipped with a catalyst could reduce the exposure. To reduce the exposure for the passenger on a sleigh an extension of the exhaust pipe may be effective.  相似文献   


16.
The monitoring of volatile organic compounds (VOCs) at environmental levels is commonly carried out in the field using Perkin-Elmer-type sorbent-based passive or active samplers. Measurements of important trace species, such as benzene, toluene and xylenes, are often calibrated using thermal desorption standards that are liquid loaded onto the sorbent. This method is normally adopted over the method of gas loading of standards, on the grounds of ease of application and cost. We report a comparison between sorbent standards prepared by both methods using the sorbent Carbopack X and show that under the conditions used here the two show good agreement with each other. We also present work using liquid-loaded standards on the sorbents Tenax and Chromosorb-106, prepared with the solvents cyclohexane and methanol. The results indicate that, to obtain 100% recovery of the determinands from the desorbed samplers, issues such as type of solvent and sorbent combination together with purge flow should be considered.  相似文献   

17.
Two-photon resonance enhanced multiphoton ionization (REMPI) has been shown to be a unique ionization method for mass spectrometry, exhibiting both high sensitivity and chemical selectivity. Because REMPI is a gas-phase method, its applications have been limited either to direct analysis of vapor phase samples, or in conjunction with an initial laser desorption or other vaporization step. We describe here for the first time a combination of membrane introduction mass spectrometry (MIMS) and REMPI with time-of-flight mass spectrometry (TOF-MS), which allows for the direct analysis of trace amounts of organic compounds in water samples. The objective of our research was the detection of very low levels of aromatic contaminants, particularly benzene, toluene, and xylene (BTX), in aqueous solutions without interference due to the water. We have measured limits of detection (LOD) for selected aromatics in water below 1 part-per-trillion with an averaging time of less than 10 s using a continuous sample flow.  相似文献   

18.
The bioremediation potential of a nitrogen-fixing leguminous plant, Galega orientalis, and its microsymbiont Rhizobium galegae was evaluated in BTX (benzene, toluene, xylene)-contaminated soils in microcosm and mesocosm scale. To measure the intrinsic tolerance of the organisms to m-toluate, a model compound representing BTX, G. orientalis and R. galegae were cultivated under increasing concentrations of m-toluate alone and in association with Pseudomonas putida pWWO, a bacterial strain able to degrade toluene-derived compounds. The test plants and rhizobia remained viable in m-toluate concentrations as high as 3000 ppm. Plant growth was inhibited in concentrations higher than 500 ppm, but restituted when plants were transferred into m-toluate-free medium. Nodulation was blocked under the influence of m-toluate, but was restored after the plants were transferred into the non-contaminated media. In the mesocosm assay the Galega plants showed good growth, nodulation and nitrogen fixation, and developed a strong rhizosphere in soils contaminated with oil or spiked with 2000 ppm m-toluate. Thus, this legume system has good potential for use on oil-contaminated sites  相似文献   

19.
Select volatile organic compounds (VOCs) in ambient air were measured at four fenceline sites at a petroleum refinery in Whiting, IN, using modified EPA Method 325 A/B with passive tubes and EPA Compendium Method TO-15 with canister samplers. One-week, time-integrated samplers were deployed for 8 weeks with tubes and canister samplers deployed in duplicate. Good precision was obtained from the duplicate tubes (<7%) and duplicate canisters (≤10%) for BTEX, perchloroethylene, and styrene. The tubes yielded statistically significantly higher concentrations than canisters for benzene, toluene, ethylbenzene, and m,p-xylene. However, all differences were estimated to be <0.1 ppbv. No concentration differences among the four Whiting sites were found for any of the VOCs.

Implications: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at refinery fenceline locations. This pilot study presents VOC data applying a modified version of EPA Method 325 A/B and its comparison to EPA Compendium Method TO-15 canister samplers at four refinery fenceline sites. The findings from this study provide additional confidence in application of the tube method at refineries to ascertain VOC source influence since tube and canister samplers were comparable and good precision was obtained from duplicate sampling for both methods. No overall difference in these reported VOC concentrations was found between Whiting sites for tubes or canisters.  相似文献   


20.
Using the differential optical absorption spectroscopy (DOAS) technique and a Fourier transform spectrometer, NO2, SO2, O3, benzene. and toluene were measured during three measurement campaigns held in Brussels in 1995, 1996, and 1997. The O3 concentrations could be explained as the results of the local photochemistry and the dynamical properties of the mixing layer. NO2 concentrations were anti-correlated to the O3 concentrations, as expected. SO2 also showed a pronounced dependence on car traffic. Average benzene and toluene concentrations were, respectively 1.7 ppb and between 4.4 and 6.6 pbb, but high values of toluene up to 98.8 ppb were observed. SO2 concentrations and to a lesser extent, those of NO2 and 03, were dependent on the wind direction. Ozone in Brussels has been found to be influenced by the meteorological conditions prevailing in central Europe. Comparisons with other measurements have shown that 03 and SO2 data are in general in good agreement, but our NO2 concentrations seem to be generally higher.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏