首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
Aerosol, NO and CO concentration, temperature, air humidity, air flow and number of running ventilation fans were measured by continuous analysers every minute for a whole week for six different one-week periods spread over ten months in 2001 and 2002 at measuring stations in the 7860 m long tunnel. The ventilation control system was mainly based on aerosol measurements taken by optical scatter sensors. The ventilation turned out to be satisfactory according to Norwegian air quality standards for road tunnels; however, there was some uncertainty concerning the NO2 levels. The air humidity and temperature inside the tunnel were highly influenced by the outside metrological conditions. Statistical models for NO concentration were developed and tested; correlations between predicted and measured NO were 0.81 for a partial least squares regression (PLS1) model based on CO and aerosol, and 0.77 for a linear regression model based only on aerosol. Hence, the ventilation control system should not solely be based on aerosol measurements. Since NO2 is the hazardous polluter, modelling NO2 concentration rather than NO should be preferred in any further optimising of the ventilation control.  相似文献   

2.
Three-dimensional turbulent flow and dispersion of gaseous pollutants carbon monoxide (CO) and nitrogen oxides (NOx) in a road tunnel was modeled using the standard kε turbulence model and solved numerically using the finite volume method. Vehicle emissions were estimated from the measured traffic flow rates and modeled as banded line sources along the tunnel floor. The effects of fan ventilation and piston effect of moving vehicles on the airflow and pollutant dilution were examined. The numerical results reveal that a peak velocity exists near the tunnel floor due to the piston effect of vehicles. The cross-sectional concentrations of air pollutants are non-uniformly distributed and concentrations rise with downstream distance. The piston effect of vehicles can alone provide 25%–34% dilution of air pollutants in the tunnel, compounded 43%–70% dilution effect according to the ventilation condition.  相似文献   

3.
The air pollution dispersion model EPISODE has been developed at the Norwegian Institute for Air Research (NILU) over the past several years in order to meet the needs of modern air quality management work in urban areas. The model has recently been used as a basis for exposure calculations of NOx and NO2 in order to assess the effects of different traffic diversion measures on health and well being for the residents in the V?lerenga-Ekeberg-Gamlebyen area in Oslo. Here we describe some results from the most recent evaluations of the model for NOx and NO2 at station Nordahl Brunsgate in Oslo for the period 1 October 1996-19 November 1996. In addition examples of population exposure calculations for Oslo performed during the winter period of 1995-96, are also presented.  相似文献   

4.
兰州市汽车尾气污染状况调查   总被引:8,自引:0,他引:8  
通过对兰州市汽车尾气污染状况的调查与分析,认为兰州市街道空气污染较重,CO、NOx、SO2、TSP、Pb各项污染均超标,其污染程度与车流强度、时间、季节、路面宽度、风速及不同形式的交通路口相关。汽车尾气排放已成为兰州市空气污染的重要来源。  相似文献   

5.
An assessment of air quality in the vicinity of a selected school has been carried out by monitoring the concentrations of primary pollutants. The results has shown that during the school hours, the measured pollutants emitted from the cars next to the selected school, such as CO and NO(2), are always under the allowable limits for Kuwaiti air quality standards. On the other hand, the concentrations of non methane hydrocarbon pollutant (nm-HC), some of which are considered to be cancergenic, are found to be above the Kuwaiti standard most of the times. A traffic counter is used to record the number of cars in the main road next to the school in 15 min intervals for 10 days during the monitoring period for air quality. Statistical analysis is performed to develop a relation for prediction of the necessary reduction in traffic, based on CO concentrations, during morning and afternoon periods on working days. A computer dispersion model (CALINE4) is also used to assess the CO concentrations based on recorded flow of traffic and emission inventory with the prevailing meteorological conditions existed at the specified time. After the validation of model, different scenarios have been evaluated to provide an acceptable solution to resolve the traffic congestion problem near the schools in the early morning hours with substantial reduction in pollution levels. The optimal solution for CO concentration reduction by managing smooth traffic flow is to reduce the traffic intensity by half in early morning and afternoon rush hours. The results of the predicted CO concentration in the vicinity of the school for the model and the statistical analysis has shown reduction of 30% and 42% respectively, for approximately 50% decrease in the car use. On the other hand the predicted CO concentration for the model and the statistics reached 24% and 33% respectively when 50% of students opted for buses instead of using private cars.  相似文献   

6.
This study is based on 82 days of continuous air-quality monitoring using two mobile monitoring vans provided by the Taiwan Environmental Protection Administration (TEPA). The purpose of the study is to reveal variations of air quality without forced ventilation from on-road emissions of light-duty vehicles (LDV) inside the Hsuehshan Tunnel. Since it was opened to traffic in June 2006, only LDV have been allowed to pass the Hsuehshan Tunnel, the longest tunnel in Taiwan and in Asia. The hourly concentrations of air pollutants at four monitoring sites inside the tunnel (pollutant: downslope entrance, downslope exit, upslope entrance, upslope exit) are as follows: (CO: 6.9 +/- 5.4, 13.6 +/- 8.7, 4.6 +/- 3.2, 14.6 +/- 8.0 ppm), (NO(X): 534 +/- 311, 1198 +/- 640, 460 +/- 242, 1704 +/- 692 ppb), (SO2: 7 +/- 5, 18 +/- 10, 9 +/- 4, 26 +/- 10 ppb), (NMHC: 1.9 +/- 2.5, 3.5 +/- 3.0, 0.8 +/- 0.9, 2.7 +/- 1.9 ppm), (PM10: 50 +/- 28, 62 +/- 29, 59 +/- 25, 85 +/- 30 microg m(-3)), and (PM(2.5): 31 +/- 18, 45 +/- 22, 35 +/- 18, 62 +/- 23 microg m(-3)). The emission factors (EFs) from LDV in this study (pollutant: downslope EF, upslope EF in mg veh(-1) km(-1)) is estimated respectively as follows: (CO: 909 +/- 469, 1468 +/- 631), (NO(X): 145 +/- 67, 331 +/- 166), (SO2: 3 +/- 2, 6 +/- 3), (NMHC: 96 +/- 65, 121 +/- 63), (PM10: 2 +/- 2, 5 +/- 4), and (PM(2.5): 2 +/- 2, 4 +/- 3). It shows that the upslope pollutant EFs are twice as big as those of the downslope. However, among these EFs, the NMHC EF is less affected by the road gradient. Likewise, its upslope EF is only 1.3 times as big as that of the downslope. In summary, the results are useful for examining the emissions from the local fleet of vehicles under the driving conditions present during the study and for observing the changes in fleet emission rates upon future replication of the study.  相似文献   

7.
利用设置在上海市中心城区交通主干道旁的路边空气质量自动监测站2018年1—12月的连续观测数据,研究苯系物(BTEX)污染水平、变化特征以及其与CO、NO x和气象参数的关系。结果表明,观测期间BTEX小时均值为0.10~169.38μg/m^3,年均值为(13.66±0.14)μg/m^3,甲苯占比最高。ρ(BTEX)受污染源排放强度和天气状况的影响大,其日变化呈单谷型,冬季值比夏季高。BTEX各化合物具有较好的同源性,ρ(苯)/ρ(甲苯)为(0.49±0.01)。BTEX与机动车尾气主要成分CO、NOx呈正相关,与风速负相关。其值低于北京、南京、郑州、杭州和西安等城市。  相似文献   

8.
The Helsinki Metropolitan Area Council (YTV) is responsible for air quality monitoring in the Helsinki area. Air quality has been monitored periodically since the late 1950s. An automatic SO2 monitoring network was constructed in 1975 and TSP measurements were added in 1978. Since then the network has been expanded and currently five automatic multicomponent stations form the basis of the network monitoring SO2, NO, NO2, CO, PM10 and O3 concentrations. Manual TSP and PM10 measurements are also conducted. Mobile monitoring units are also being used as well as special measurement campaigns. The effects of air pollution on nature are studied in bioindicator monitoring. An air quality index is used in order to inform the public of the current air quality situation. Changes in air quality are reflected in monitoring strategy. SO2 concentrations have decreased in the past two decades. Annual averages in 1995 were at or below 5 µg/m3. Traffic is the major source for pollutants even though catalytic converters have lowered traffic emissions somewhat. The highest annual average NO2 concentration at an urban site was 49 µg/m3 in 1995, and there has been no clear change in NO2 levels. There has been a decreasing trend in CO concentrations. Maximum annual TSP and PM10 averages in 1995 were 92 and 32 µg/m3, respectively. The highest average lead concentration was 0.01 µg/m3. Elevated concentrations are experienced from time to time. During the spring daily TSP and PM10 concentrations can go up to around 300 and 150 µg/m3, respectively. This is caused by resuspension mainly due to street sanding. Also a major winter NO2 episode occurred in December 1995. The highest hourly NO2 concentrations reached 400 µg/m3.  相似文献   

9.
Passive air sampling for nitrogen dioxide (NO(2)) and select volatile organic compounds (VOCs) was conducted at 24 fire stations and a compliance monitoring site in Dallas, Texas, USA during summer 2006 and winter 2008. This ambient air monitoring network was established to assess intra-urban gradients of air pollutants to evaluate the impact of traffic and urban emissions on air quality. Ambient air monitoring and GIS data from spatially representative fire station sites were collected to assess spatial variability. Pairwise comparisons were conducted on the ambient data from the selected sites based on city section. These weeklong samples yielded NO(2) and benzene levels that were generally higher during the winter than the summer. With respect to the location within the city, the central section of Dallas was generally higher for NO(2) and benzene than north and south. Land use regression (LUR) results revealed spatial gradients in NO(2) and selected VOCs in the central and some northern areas. The process used to select spatially representative sites for air sampling and the results of analyses of coarse- and fine-scale spatial variability of air pollutants on a seasonal basis provide insights to guide future ambient air exposure studies in assessing intra-urban gradients and traffic impacts.  相似文献   

10.
Determination of O3, NO2, SO2, CO and PM10 measured in Belgrade urban area   总被引:1,自引:0,他引:1  
O(3), NO(2), SO(2), CO and PM(10) concentrations, simultaneously determined for the first time in Belgrade urban area in the autumnal period of 2005, are presented. The obtained results display similar behaviour of SO(2), NO(2), CO, PM(10) opposite from that of O(3). The weekend effect was also investigated showing diminution of average daily concentrations of SO(2), NO(2), PM(10) and CO for 72, 40, 37 and 42% respectively, and increase of the average daily concentration of O(3) for 56%. Influence of meteorological conditions on observed concentration levels was studied, too. The observed influence of wind speed on the O(3) nightly concentration levels was analyzed pointing to the phenomena of O(3) transport during episodic measurements. To make an identification of possible pollution sources and analyse the influence of meteorological parameters on pollution levels, air back trajectories for high level concentrations episodes were calculated and analysed. A multivariate receptor modelling (Principal Component Analysis, Cluster Analysis) has been applied to a set of data in order to determine the contribution of different sources. It was found that the main principal components, extracted from the air pollution data, were related to gasoline combustion, oil combustion and ozone transport.  相似文献   

11.
Carbon monoxide (CO) is one of the six criteria air pollutants related to urbanization and has a wide range of health effects. The study measured and compared the exhaled CO levels among commuters and roadside vendors in potentially heavy and low traffic volume areas of Karachi, a megacity in Pakistan. Saddar town [areas of M. A. Jinnah Road (Tibet Center, Denso Hall) and Empress Market] was selected to represent an area of high traffic volume and the suburban town of Gadap (Gadap and Gulshan-e-Maymar) was selected to represent an area of no or low traffic volume. The study compared the CO exposure of commuters and roadside vendors in high and low traffic volume in Karachi. CO exposure was measured in expired air using the breath analyzer module of Bacharach Monoxor-II, USA. A total of 326 individuals (115 commuters and 211 stationary roadside vendors) from Saddar town (n?=?193) and Gadap town (n?=?133) were selected. In addition, CO levels in ambient air in the same areas, using portable CO analyzer (Bacharach, Monoxor-II, USA), were measured. The mean ambient CO level at Saddar town was 15.6 (SE ± 2.6) ppm compared to 3.3 (SE ± 0.3) ppm at Gadap town. The mean CO level in expired air was significantly higher among nonsmokers at Saddar town (12.8 ± 0.5 ppm) compared to the nonsmokers at Gadap town (7.8 ± 0.4 ppm). The mean CO level in expired air among smokers was twice that of nonsmokers (21.6 vs. 10.6 ppm). CO in expired air was greater among high traffic volume commuters and roadside stationary population in Karachi, Pakistan. The population in Karachi is exposed to high concentration of air pollutants. These pollutants need to be characterized for health effects and interventions needs to be developed.  相似文献   

12.
以乌鲁木齐市2008-2012年7个空气自动监测点位小时浓度数据为基础数据,利用ArcGIS 技术,分析了其NO2年变化、月变化、日变化、空间分布等污染特征。结果表明,NO2年均值为0.065~0.068 mg/m3,基本保持稳定;NO2呈明显的季节变化,冬季污染较重,春节、秋季次之,夏季空气质量相对较好;NO2呈现“单峰型”的日变化特征,夜间NO2明显高于白天;不同季节 NO2的空间分布特征不同,与交通、供暖、人口密度、地理位置密切相关;NO2分布与风速相关关系明显,而与气温、湿度的关系为非线性。  相似文献   

13.
Emissions of NOx and SO2 were monitored in the presence of ammonia liquor in a 0.09 m2 and 2 m high stainless-steel fluidized-bed combustor. Experiments were carried out at 2 m/s fluidizing velocity, 40% excess air, and 870 °C bed temperature. Ammonia liquor with 7% ammonia by weight was injected into the freeboard of the combustor 52 cm above the distributor through a water-cooled injector. A 65 : 34 primary/secondary air ratio was maintained throughout the investigation. Approximately 70% of NO and 20% of SO2 was reduced at an NH3/NO molar ratio of 2 : 1, respectively. However, a higher reduction in SO2 emissions (62%) was achieved at a very high NH3/NO molar ratio of 7 : 1. These experiments showed that ammonia addition did have a significant effect in SO2 reduction if injected in an excess amount. The injection of ammonia liquor combined with staged combustion was found to be very effective in reducing NOx emissions. A reduction of about 50% was achieved at an NH3/NO molar ratio of 0.6 : 1 which is also coupled with a very low level of ammonia in the flue.  相似文献   

14.
根据2014年全年实时在线观测数据,分析了徐州睢宁地区大气细颗粒物(PM_(2.5))和气态污染物(包括SO_2、CO、NO_x、O_3)质量浓度的季节性变化特征。结合后向轨迹模型,分析不同气团对该地区大气污染浓度的影响。PM_(2.5)与O_3值在夏季最低,呈显著相关,表明夏季PM_(2.5)主要受控于本地大气光化学活性。在冬季,除O_3外,PM_(2.5)、SO_2、CO、NO_x值最高,且大气颗粒物主要以细粒子为主。O_3在春季最高,并与远程传输的气团且经过我国东部污染源密集地区相对应。高浓度的PM_(2.5)主要与冬季缓慢移动的气团相对应,这可能将PM_(2.5)及其气态前体物传输至该地区进而加重大气污染程度。  相似文献   

15.
This paper describes the development of artificial neural network (ANN) based carbon monoxide (CO) persistence (ANNCOP) models to forecast 8-h average CO concentration using 1-h maximum predicted CO data for the critical (winter) period (November–March). The models have been developed for three 8-h groupings of 10 p.m. to 6 a.m., 6 a.m. to 2 p.m. and 2–10 p.m., at two air quality control regions (AQCRs) in Delhi city, representing an urban intersection and an arterial road consisting heterogeneous traffic flows. The result indicates that time grouping of 2–10 pm is dominantly affected by inversion conditions and peak traffic flow. The ANNCOP model corresponding to this grouping predicts the 8-h average CO concentrations within the accuracy range of 68–71%. The CO persistence values derived from ANNCOP model are comparable with the persistence values as suggested by the Environmental Protection Agency (EPA), USA. This work demonstrates that ANN based model is capable of describing winter period CO persistence phenomena.  相似文献   

16.
Infrared spectrometry is a versatile basis to analyse greenhouse gases in the atmosphere. A multicomponent air pollution software (MAPS) was developed for retrieval of gas concentrations from radiation emission as well as absorption measurements. Concentrations of CO, CH4, N2O, and H2O as well as CO2, NO, NO2, NH3, SO2, HCl, HCHO, and the temperature of warm gases are determined on-line. The analyses of greenhouse gases in gaseous emission sources and in ambient air are performed by a mobile remote sensing system using the double-pendulum interferometer K300 of the Munich company Kayser-Threde. Passive radiation measurements are performed to retrieve CO, N2O, and H2O as well as CO2, NO, SO2, and HCl concentrations in smoke stack effluents of thermal power plants and municipal incinerators and CO and H2O as well as CO2 and NO in exhausts of aircraft engines. Open-path radiation measurements are used to determine greenhouse gas concentrations at different ambient air conditions and greenhouse gas emission rates of diffusive sources as garbage deposits, open coal mining, stock farming together with additional compounds (e.g. NH3), and from road traffic together with HCHO. Some results of measurements are shown. A future task is the verification of emission cadastres by these inspection measurements.  相似文献   

17.
Our group previously demonstrated that carbon dioxide (CO2) levels in heavily occupied schools correlate with the levels of airborne bacterial markers. Since CO2 is derived from the room occupants, it was hypothesized that in schools, bacterial markers may be primarily increased in indoor air because of the presence of children; directly from skin microflora or indirectly, by stirring up dust from carpets and other sources. The purpose of this project was to test the hypothesis. Muramic acid (Mur) is found in almost all bacteria whereas 3-hydroxy fatty acids (3-OH FAs) are found only in Gram-negative bacteria. Thus Mur and 3-OH FA serve as markers to assess bacterial levels in indoor air (pmol m(-3)). In our previous school studies, airborne dust was collected only from occupied rooms. However, in the present study, additional dust samples were collected from the same rooms each weekend when unoccupied. Samples were also collected from outside air. The levels of dust, Mur and C10:0, C12:0, C14:0, and C16:0 3-OH FAs were each much higher (range 5-50 fold) in occupied rooms than in unoccupied school rooms. Levels in outdoor air were much lower than that of indoor air from occupied classrooms and higher than the levels in the same rooms when unoccupied. The mean CO2 concentrations were around 420 parts per million (ppm) in unoccupied rooms and outside air; and they ranged from 1017 to 1736 ppm in occupied rooms, regularly exceeding 800-1000 ppm, which are the maximum levels indicative of adequate indoor ventilation. This indicates that the children were responsible for the increased levels of bacterial markers. However, the concentration of Mur in dust was also 6 fold higher in occupied rooms (115.5 versus 18.2 pmole mg(-1)). This further suggests that airborne dust present in occupied and unoccupied rooms is quite distinct. In conclusion in unoccupied rooms, the dust was of environmental origin but the children were the primary source in occupied rooms.  相似文献   

18.
Hereafter, an assessment of the ability of the chemiluminescence method to measure ambient NO2 with an accuracy within 15%, as requested by the data quality objective of European directive 1999/30/CE, is presented. In general, uncertainty is evaluated using the response to reference materials or by means of inter-comparisons used to determine some statistics like repeatability, reproducibility and calibration bias. These are incomplete approaches and the method of the Guide to the Expression of Uncertainty in Measurement, advised by the Directive, should be preferred. In fact, even if it requires a large data set, it allows the relative influence of all possible sources of uncertainty to be studied. The extent of NO2 uncertainty is mainly dependent on the level of NO. It is decreased by NOx and the correlation between NOx and NO. Furthermore, the uncertainty budget reveals that the contribution of accuracy of calibration standard, linearity, converter efficiency and drift of the analyser between calibration checks to the overall uncertainty is less important than the contribution of interference, mainly humidity and PAN in rural areas. The relative expanded uncertainty of the NO2 hourly average exceeds 30% for NO2 concentrations lower than 40 microg m(-3). Nevertheless, the data quality objective of 15% is reached for 200 microg m(-3), the hourly limit value of the European directive. On the contrary, at the limit value on the annual average, 40 microg m(-3), the data quality objective is not met if NO is higher than 100 microg m(-3). However, the data quality objective could be reached by correcting the measurements with the bias due to interference.  相似文献   

19.
运用大气扩散理论,得到了隧道内自然通风和纵向通风状态下的可吸入颗粒物(PM10)扩散模型,并由隧道口PM10浓度、隧道截面积、隧道内风速,以及车流量和类型等参数,获得了整条隧道内的不同PM10浓度分布.模型表明,随着隧道深度的增加,PM10浓度逐渐增大.通过采用纵向通风的玄武湖隧道各参数,得到了3组不同条件下的PM10扩散模型,并用所得模型计算了隧道内不同深度处PM10的浓度.沿隧道不同深度测得的PM10浓度值的比较结果表明,实际测定值围绕计算值上下波动,两者之间具有良好的一致性.  相似文献   

20.
In Oslo, traffic has been one of the dominating sources of air pollution in the last decade. In one part of the city where most traffic collects, two tunnels were built. A series of before and after studies was carried out in connection with the tunnels in use. Dispersion models were used as a basis for estimating exposure to nitrogen dioxide and particulate matter in two fractions. Exposure estimates were based on the results of the dispersion model providing estimates of outdoor pollutant concentrations on an hourly basis. The estimates represent concentrations in receptor points and in a square kilometre grid. The estimates were used to assess development of air pollution load in the area, compliance with air quality guidelines, and to provide a basis for quantifying exposure-effect relationships in epidemiological studies. After both tunnels were taken in use, the pollution levels in the study area were lower than when the traffic was on the surface (a drop from 50 to 40 micrograms m-3). Compliance with air quality guidelines and other prescribed values has improved, even if high exposures still exist. The most important residential areas are now much less exposed, while areas around tunnel openings can be in periods exposed to high pollutant concentrations. The daily pattern of exposure shows smaller differences between peak and minimum concentrations than prior to the traffic changes. Exposures at home (in the investigation area) were reduced most, while exposures in other locations than at home showed only a small decrease. Highest hourly exposures are encountered in traffic.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号