首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An ion selective electrode (ISE) for determining Cr(VI) using supported liquid membranes (SLMs) containing trioctylphosphine oxide (TOPO) was investigated in this study. TOPO, as a carrier, had a high selectivity for Cr(VI) against interfering ions such as sulfate, nitrate, nitrite, and chloride. The composition of the SLM was optimized as 0.193 g TOPO/1 mL NPOE (o-nitrophenyl octyl ether)/0.5 g poly (vinyl chloride) for detection of Cr(VI). The Cr(VI) concentration was measured in the range of1 × 10-3 to 1 × 10-6 M with the SLM prepared in the study. It seemed that Cr(VI) was transported in the SLM as a triply charged ion indicated by the slope of the emf response. Selectivity coefficients and detection limits of Cr(VI) in the presence of interfering ions were determined experimentally using the fixed interference method.  相似文献   

2.
Hexavalent chromium (Cr(VI)) is an acknowledged hazardous material in drinking waters. As such, effective monitoring and assessment of the risks posed by Cr(VI) are important analytical objectives for both human health and environmental science. However, because of the lack of highly sensitive, rapid, and simple procedures, a relatively limited number of studies have been carried out in this field. Here we report a simple and sensitive analytical procedure of flow injection analysis (FIA) for sub-nanomolar Cr(VI) in drinking water samples with a liquid core waveguide capillary cell (LWCC). The procedure is based on a highly selective reaction between 1, 5-diphenylcarbazide and Cr(VI) under acidic conditions. The optimized experimental parameters included reagent concentrations, injection volume, length of mixing coil, and flow rate. Measurements at 540 nm, and a 650-nm reference wavelength, produced a 0.12-nM detection limit. Relative standard deviations for 1, 2, and 10 nM samples were 5.6, 3.6, and 0.72 % (n?=?9), and the analysis time was <2 min sample?1. The effects of salinity and interfering ions, especially Fe(III), were evaluated. Using the FIA-LWCC method, different sources of bottled waters and tap waters were examined. The Cr(VI) concentrations of the bottled waters ranged from the detection limit to ~20 nM, and tap waters collected from the same community supply had Cr(VI) concentration around 14 nM.  相似文献   

3.
A new class of nano-scale Fe0 particles (NZVI) supported on a PAA/PVDF membrane (NZVI-PAA/PVDF) were synthesized and the feasibility of using NZVI-PAA/PVDF for reductive immobilization of Cr(VI) in water was investigated through laboratory batch tests. The results showed that the Cr(VI) removal capacity of NZVI-PAA/PVDF was 181 mg Cr/g Fe at an initial Cr(VI) concentration of 20 mg L(-1) under pH 6.5 +/- 0.1. XPS results showed that Cr(VI) was converted to nontoxic Cr(III). Interfering ions exerted various degrees of impact on NZVI-PAA/PVDF's Cr(VI) removal capacity. Specifically, Ca2+ alone showed the mildest impact while the presence of ions (Mg2+ and HCO3-) exerted the greatest impact. An advantage of NZVI-PAA/PVDF is that the nano-scale Fe0 and resultant particles were combined within a PAA/PVDF membrane, which prevents secondary pollution. Moreover, a piece of PAA/PVDF membrane (4.7 cm diameter) can still support 6.51 mg of nano-scale Fe0 particles after being renewed.  相似文献   

4.
A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.  相似文献   

5.
The objective of this work was to develop a novel wet-scrubbing process using Fe(VI) for the simultaneous removal of gaseous NO and SO(2). The oxidation of SO(2) and NO with Fe(VI) was studied in aqueous solution at alkaline pH (9.0-11.0). A stoichiometric molar ratio for NO and SO(2) oxidation with Fe(VI) was determined to be nearly 3.0. Sulfate and nitrate was identified as final products by ion chromatography from the reaction at pH 9.0-11.0. The feasibility of simultaneous removal of multiple gas pollutants with the continuous feeding of ferrate in lab-scale was investigated from the view of industrial application. It was found that the removal efficiency of NO and SO(2) was enhanced with the increase of Fe(VI) concentration, more than 90% NO removal efficiency and 100% SO(2) removal efficiency were achieved by wet-scrubbing process using Fe(VI) at room temperature and ambient atmosphere. The results demonstrate that Fe(VI) could be an effective wet-scrubbing agent for the simultaneous removal of NO and SO(2).  相似文献   

6.
This paper presents the chemical speciation and retention behavior of chromium (Cr), nickel (Ni), and cadmium (Cd) prior to and after the electrokinetic remediation in glacial till soil. The speciation of the metals was predicted using the chemical speciation program MINEQL+. The simulations were performed for single-contaminant with only Cr(VI) or Ni, and multi-contaminants consisting of: (1) Cr(VI), Ni, and Cd; (2) Cr(III), Ni and Cd; (3) Cr(VI), Cr(III), Ni and Cd; (4) Cr(VI), Ni, and Cd with reducing agents; and (5) Cr(III), Ni, and Cd with oxidizing agent (Mn). The results showed that the speciation and distribution of cationic metals [Ni, Cd, and Cr(III)] in glacial till soil remain unaffected or slightly affected during electrokinetics. This is attributed to the high pH buffering capacity of the glacial till, leading the metals to precipitate in the soil prior to and after electrokinetics. This study showed that during electrokinetics, Cr(VI) existed as anionic complex and migrated towards the anode and the migration is maximum in case of a single-contaminant system. The study also showed that near the anode in the absence of any reducing and oxidizing agent, Cr(VI) mostly adsorbed, and some of Cr(VI) reduced to Cr(III) and migrated towards the cathode and finally precipitated due to high pH conditions. Ni and Cd remain adsorbed or precipitated due to the high pH conditions throughout the soil. Among the reducing agents, the sulfide had significant effect on the migration of metals compared to ferrous ions. While in the presence of oxidizing agent (Mn), no noticeable Cr(VI) was found in the soil sample indicating the reduction of Cr(VI) to Cr(III) and the predominance of reducing conditions due to the presence of naturally occurring iron in the glacial till soil. Overall, this study provides a reasonable explanation of the speciation and distribution of chromium, nickel and cadmium during the electrokinetic remediation of glacial till soil.  相似文献   

7.
Airborne particulate matter (PM10) was collected for a period of 1 year at six locations in Madurai city, India. The chemical analyses on PM10 samples were carried out for the estimation of heavy metals and ions using atomic absorption spectroscopy and ion chromatography respectively. The average PM10 concentrations varied from 97.2 to 152.5 μg/m3, which were found to be below the Indian air quality standards. While industrial areas had the highest concentrations of heavy metals such as Fe, Zn and Cr and also the $\text{SO}_{4}^{2-}$ ions, traffic areas with relatively higher traffic densities in the city endured highest concentrations of Cd and the $\text{NO}_{3}^{-}$ ion. As gaseous pollutants serve as precursors of ionic particles in the atmospheric environment, gaseous pollution control is necessitated along with particulate with special reference to heavy metal and ion pollution abatement for the sustainable development of Madurai city.  相似文献   

8.
Drinking water treatment typically uses strong oxidants such as chlorine which are capable of converting Cr(III) to Cr(VI). The rates and extent of Cr(III) oxidation by chlorine are not well established. Cr(III) oxidation experiments were therefore conducted in distilled deionized water and New York City tap water dosed initially with Cr(III) and supplemented with sodium hypochlorite to increase free chlorine residual. Reaction progress was monitored using capillary electrophoresis which quenched reactions and allowed for quantification of Cr(VI). Three different forms of Cr(III) were used as reactants: a Cr(III) nitrate salt, Cr(III)-EDTA, and Cr(III) hydroxide. Rates of Cr(VI) production for all three forms of Cr(III) were rapid, on the order of hours. However, oxidation rates slowed and a plateau in Cr(VI) concentrations was reached. This resulted in less than 100% conversion of Cr(III) to Cr(VI) even at relatively high chlorine doses (10 to 100 mg L(-1) as Cl(2)). The loss of free chlorine due to a non-Cr chlorine demand, the precipitation of Cr(III) to Cr(OH)(3)(s), and the partial oxidation of Cr(III) to intermediate oxidation states (i.e. Cr(IV) and Cr(V)) were examined and eliminated as possible explanations for this behavior. Consumption of chlorine via reaction with intermediate oxidation states of Cr is therefore offered as a possible explanation for the plateau in Cr(VI) concentrations.  相似文献   

9.
Plant seed toxicity tests can be used to evaluate hazardous waste sites and to assess toxicity of complex effluents and industrial chemicals. Conventional plant seed toxicity tests are performed using culture dishes containing filter paper. Some reports indicate that filter papers might interfere with the toxicity of inorganic substances. In this study, a plastic seed tray was used. Rice was used as the test species.A comparison of results in the literature and this study revealed that variation of test species, methods, exposure duration, and other factors may affect the test results. The results of this study showed that the order of decreasing toxicity of metal ions was Cu>Ag>Ni>Cd>Cr(VI)>Pb>Zn>Mn>NaF for rice. The test results were similar to those reported in the literature for lettuce Ag>Ni>Cd,Cu>Cr(VI)>Zn>Mn, millet Cu,Ni>Cd>Cr(VI)>Zn>Mn, and ryegrass Cu>Ni>Mn>>Pb>Cd>Zn>Al>Hg>Cr>Fe. The order of decreasing toxicity of organic herbicides was paraquat, 2,4-D>>glyphosate>bromacil.  相似文献   

10.
Chromium (VI) [Cr (VI)] biosorption by four resistant autochthonous bacterial strains was investigated to determine their potential for use in sustainable marine water-pollution control. Maximum exchange between Cr (VI) ions and protons on the cells surfaces were at 30–35 °C, pH?2.0 and 350–450 mg/L. The bacterial strains effectively removed 79.0–90.5 % Cr (VI) ions from solution. Furthermore, 85.3–93.0 % of Cr (VI) ions were regenerated from the biomasses, and 83.4–91.7 % of the metal was adsorbed when the biomasses was reused. Langmuir isotherm performed better than Freundlich isotherm, depicting that Cr (VI) affinity was in the sequence Rhodococcus sp. AL03Ni?>?Burkholderia cepacia AL96Co?>?Corynebacterium kutscheri FL108Hg?>?Pseudomonas aeruginosa CA207Ni. Biosorption isotherms confirmed that Rhodococcus sp. AL03Ni was a better biosorbent with a maximum uptake of 107.46 mg of Cr (VI) per g (dry weight) of biomass. The results highlight the high potential of the organisms for bacteria-based detoxification of Cr (VI) via biosorption.  相似文献   

11.
Drainage water diverted from a farm pasture, which was heavily loaded with manure, was monitored during a rain event. Concurrent anion and cation determinations at intervals of 10 min could be achieved with a new capillary electrophoresis system employing dual injection at opposite ends of the separation capillary. The flow injection approach enabled automation of the sampling process. Interruption of the separation voltage was not necessary. Contactless conductivity detection with an electrolyte solution optimized for the purpose allowed the facile simultaneous detection of the inorganic ions Cl(-), NO(3)(-), SO(4)(2-), HPO(4)(2-), NO(2)(-), NH(4)(+), K(+), Ca(2+), Na(+) and Mg(2+) and the acquisition of temporal concentration profiles of these species. The detection limits achieved were between 20 and 200 [micro sign]g l(-1) for all ions and the repeatability of peak areas and peak heights was better than 1%. The quantitative results were verified by analysing individual samples later in the laboratory with photometry and ion chromatography and the average deviations were found to be between 4 and 12%. This contribution presents a further step in the development of capillary electrophoresis towards a fully automated, low maintenance field method.  相似文献   

12.
A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)–diethyldithiocarbamate–(Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1–2.2 μg L?1 while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.  相似文献   

13.
Chromium species (Cr(III), Cr(VI), and Cr(III)-organic) in groundwater of a tannery contaminated area were monitored during pre- and post-monsoon seasons for a period of 3 years (May 2004 to January 2007). The objectives of the study were (1) to investigate the temporal variation of chromium species and other matrix constituents and (2) to study the redox processes associated with the temporal variation of chromium species. Samples were collected from 15 dug wells and analyzed for chromium species and other constituents. The results showed that the groundwater was relatively more oxidizing during post-monsoon periods than the pre-monsoon periods. Except one sample, the concentration of chromium species were found in the order of Cr(VI)>Cr(III)>Cr(III)-organic complexes during all the pre- and post-monsoon periods. In most of the wells, the concentrations of Cr(III), Cr(VI), and Cr(III)-organic decreased during post-monsoon periods compared to their pre-monsoon concentrations. However, the Cr(VI)/CrTotal ratio still increased and the Cr(III)/CrTotal ratio decreased during post-monsoon periods in most of the samples. The possible mechanisms for the temporal variation of chromium species were (1) Fe(II) reduction of Cr(VI) vs oxidation of Fe(II) by dissolved oxygen and (2) oxidation of Cr(III) by Mn(IV).  相似文献   

14.
The ability of Quercus crassipes acorn shells (QCS) to remove Cr(VI) and total chromium from aqueous solutions was investigated as a function of the solution pH, ionic strength, and background electrolytes. It was found that Cr(VI) and total chromium removal by QCS depended strongly on the pH of the solution. Cr(VI) removal rate increased as the solution pH decreased. The optimum pH for total chromium removal varied depending on contact time. NaCl ionic strengths lower than 200 mM did not affect chromium removal. The presence of 20 mM monovalent cations and anions, and of divalent cations, slightly decreased the removal of Cr(VI) and total chromium by QCS; in contrast, divalent anions (SO4 2?, PO4 2?, CO3 2?) significantly affected the removal of Cr(VI) and total chromium. The biosorption kinetics of chromium ions followed the pseudo-second-order model at all solution pH levels, NaCl ionic strengths and background electrolytes tested. Results suggest that QCS may be a potential low-cost biosorbent for the removal of Cr(VI) and total chromium from aqueous solutions containing various impurities.  相似文献   

15.
A simply structured, cheap hexachromium monitor was developed. The monitor is based on UV/VIS absorption technique. A 2-m long water core optical fiber was employed as a long path length sample cell and a UV light emitting diode (LED) was used as a light source. The emission profile of the UV LED fits very well with the absorption spectrum of chromate ions in water. Therefore, the light-dispersing element, which is usually used in an optical spectrometer, is not necessary in this monitor design. The water core fiber as a long path length makes the monitor highly sensitive for hexachromium detection. This monitor is specific for hexachromium detection without interference from tri-valence chromium ions. A detection limit of 0.1 ng Cr(VI) ml(-1) was obtained with this simple monitor.  相似文献   

16.
根据南通市2016和2017年冬季大气多参数站自动监测PM2.5数据和在线离子色谱分析仪Marga监测的PM2.5中水溶性离子数据,分析了南通市冬季PM2.5中水溶性离子污染特征。结果表明,南通市2016和2017年冬季,ρ(PM2.5)分别为58和54μg/m 3,均高出其年均值(14μg/m^3);ρ(水溶性离子)总占ρ(PM2.5)百分比分别为74.5%和74.3%;二次离子ρ(NO3^-、SO4^2-和NH4^+)占ρ(PM2.5)百分比分别为66.8%和66.6%;各水溶性离子占比大小依次为:NO3^-、SO4^2-、NH4^+、Cl^-、K^+、Na^+、Ca^2+、Mg^2+。对ρ(NO3^-)/ρ(SO 4^2-)分析表明,移动源已经成为南通市冬季的主要污染源,且呈逐年增强趋势。对氯氧化率和硫氧化率的分析表明,南通市冬季存在较明显的二次污染,SO2的转化程度大于NO2。除Na^+和Mg^2+外,其他离子与PM2.5均呈显著相关性,NO3^-、SO4^2-与NH4^+之间的相关系数最高,Cl^-与除Na^+外的所有阳离子均呈显著相关性。  相似文献   

17.
This paper considers the spatial and temporal variability in concentrations of the potentially acidifying ions in precipitation in Lithuania during the 1981-2004 period. Chemical analysis of precipitation included measurements of pH, conductivity, sulfate (SO4(2-)), nitrate (NO3-), chloride (Cl-), ammonium (NH4+), sodium (Na+), potassium (K+), and calcium (Ca2+). Temporal trends in the potentially acidifying ion concentrations in precipitation and wet deposition were evaluated using the non-parametric Mann-Kendall test and Sen's slope estimator. A statistically significant decline was observed in non-sea salt sulfate (nssSO4(2-)) and hydrogen (H+) ions concentrations (82% and 79%, respectively) and wet depositions (88% and 74%, respectively). Temporal trends both in concentration and wet deposition of nitrate and ammonium were not as pronounced as trends in sulfate concentration. Analysis of air mass backward trajectories was applied to reveal the influence of air mass originating in different regions on wet deposition of acidifying species in Lithuania. Sector analysis clearly showed that wet deposition of sulfur and nitrogen in Lithuania is to a large extent anthropogenic and the main source regions of acidifying species contributing to wet deposition in Lithuania are in South and Central Europe.  相似文献   

18.
Several samples of airborne particulate matter (PM), collected from 6th November to 6th December 2003 at a coastal site in the south-east of Italy, have been analyzed by different techniques to characterize elemental composition and morphological properties of the inorganic PM fraction and obtain preliminary results on anthropogenic contributions. Al, Cr, Cu, Fe, Mn, V, Pb, Ti, Ca and Zn mass concentrations, evaluated by an inductively coupled plasma atomic emission spectrometer, account for up to l% of the bulk PM mass in the investigated samples. According to geochemical calculations, Ca, Al, Fe and Mn are predominantly of crustal origin, while Cr, Cu, Pb, V, Ti and Zn heavy metals are of anthropogenic origin. Ion chromatography analyses have identified sulfate (SO(4)(2-)) nitrate (NO(3)(-)), sodium (Na(+)), and ammonium (NH(4)(+)) as the main ionic components accounting for up to 38% of the total PM mass and up to 90% of the total ionic mass. Besides ion chromatography, X-ray energy dispersive (EDX) microanalyses have revealed the high variability of Cl: its weight concentration varies from about 24% to below the detection limit (>or=0.5%) in the investigated samples. The marked anti-correlation between the excess of S and the Cl/Na ratio has allowed inferring that reactions between sea salt particles and acidic sulfates, which liberate HCl gas to the atmosphere leaving particles enriched in non-sea-salt sulfates, have significantly contributed to chloride depletion. Morphological analyses by scanning electron microscopy have shown that about 90% of the total sampled particles have a diameter 相似文献   

19.
Al, Cd, Cr, Cu, Fe, Mn, Pb, Zn, NH4+, Mg2+, Ca2+, Na+, K+, Cl-, NO3- and SO4(2-), along with pH were determined in wet and dry deposition samples collected at Al-Hashimya, Jordan. Mean trace metal concentrations were similar or less than those reported for other urban regions worldwide, while concentrations of Ca2+ and SO4(2-) were the highest. The high Ca2+ concentrations were attributed to the calcareous nature of the local soil and to the influence of the Saharan dust, while the high concentrations of SO4(2-) were attributed to the influence of anthropogenic sources and Saharan dust soil. Except for SO4(2-), NO3-, and Ca2+, dry deposition fluxes of measured metals and ions were higher than their corresponding wet deposition fluxes. The high annual average pH values recorded for wet and dry deposition samples were attributed to the neutralization of acidity by alkaline species. Cd, Cr, Cu, Pb, Zn, NO3- and SO4(2-) were enriched in wet and dry deposition samples relative to crustal material, and a significant anthropogenic contribution to these elements and ions is tentatively suggested. Finally, the possible sources and the main factors affecting the concentrations of the measured species are discussed.  相似文献   

20.
Hexahydrophthalic anhydride (HHPA) and methylhexahydrophthalic anhydride (MHHPA) are two highly allergenic compounds used in the chemical industry. A method was developed for quantification of protein adducts of HHPA and MHHPA in human plasma. The plasma was dialysed and the anhydrides were hydrolysed from the proteins at mild acidic conditions. The released hexahydrophthalic acid (HHP acid) and methylhexahydrophthalic acid (MHHP acid) were purified by reversed solid phase extraction followed by derivatisation with pentafluorobenzyl bromide. The derivatives were analysed using GC-MS in negative ion chemical ionisation mode with ammonia as moderating gas. As internal standards, deuterium labelled HHP and MHHP acids were used. The detection limits were 0.06 pmol mL(-1) plasma for HHP acid and 0.03 pmol mL(-1) plasma for MHHP acid. The between-day precisions for HHP acid were 18% at 0.3 pmol mL(-1) and 8% at 4 pmol mL(-1). For MHHP acid, the precisions were 13% at 0.3 pmol mL(-1) and 9% at 4 pmol mL(-1). There were strong correlations (r=0.94 for HHPA and 0.99 for MHHPA) between total plasma protein adduct concentrations and serum albumin adduct levels. Workers exposed to time-weighted average air levels of HHPA between < 1 and 340 microg m(-3) and between 2 and 160 microg m(-3) for MHHPA had plasma adduct levels between the detection limits of the methods and 8.40 and 19.0 pmol mL(-1), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号