1.
Many VOC represent hazards to human health through chronic exposure. Recent European and world-wide legislation proposes limit values for ambient concentrations of these compounds. However, very little experimental data exists for true population exposure. In 1996, the European MACBETH initiative set out to measure population exposure to benzene in six European cities. This study details the French contribution to this program. Six campaigns were carried out, each comprising measurements at 100 outdoor sites and the participation of 50 non-smoking volunteers who wore personal samplers and had passive monitors installed in their homes. Iso-concentration maps were drawn for each campaign and the results showed that outdoor concentrations were significantly lower than indoors. Almost 75% of the volunteers were exposed to mean concentrations higher than the limit value of 5µgm3. It is demonstrated that personal exposure levels cannot be deduced simply by combining indoor and outdoor background concentrations. It is also shown that there is need for better knowledge of the contributions to overall exposure of outdoor microenvironments and the authors hope that future European directives will take this into account.  相似文献   

2.
The aim of the present work is to compare the performance of the Radiello passive sampler versus UV-photometric ozone analyser to measure surface ozone in a Mediterranean Spanish coastal area. The comparison presented considers precision, bias, accuracy, selectivity, detection limit, cost and applicability. For assessing precision, co-located samplers were exposed in duplicate in two reference-sampling sites, beside UV-photometric ozone analyser. Bias was calculated comparing results of passive samplers exposed in three reference-sampling sites and two contrast-sampling sites with the measurements given by the reference analysers. Accuracy was calculated following the EN 482:1994 standard. The limit of detection was calculated as 3 times the standard deviation of the blanks in a batch of passive samplers. The compared Radiello passive samplers give a precision of 5.2%, a bias of 13.8%, an accuracy of 20.5% and a limit of detection of 12.6 microg m(-3). The selectivity and applicability of this methodology is in both aspects successful. Surface ozone levels measured with passive samplers were comparable with the averaged values measured with the reference analyser both in the reference-sampling sites and in the contrast-sampling sites.  相似文献   

3.
A biennial integrated survey, based on the use of vascular plants for the bioindication of the effects of tropospheric ozone, was performed in the area of Pisa (Tuscany, Central Italy). It also investigated the distribution of selected trace elements in plants and the data were compared with those obtained from the use of passive samplers, automatic analysers of ozone and lichen biodiversity. Photochemically produced ozone proved to be present during the warm season, with maximum hourly means surpassing 100 ppb: the use of supersensitive tobacco Bel-W3 confirmed the value of detailed, cost-effective, monitoring surveys. Trials with clover clones demonstrate that sensitive plants undergo severe biomass reduction in the current ozone regime. The mean NC-S (clover clone sensitive to ozone):NC-R (resistant) biomass ratio ranged from 0.7 (in 1999) to 0.5 (in 2000). The economic impact of these reductions deserves attention. The data obtained using passive ozone samplers exceeded those obtained using an automatic analyser. The mapping of epiphytic lichen biodiversity was not related to the geographical ozone distribution as can be seen from the tobacco's response. Lettuce plants grown under standardized conditions were used positively as bioaccumulators of trace elements: Pb was abundantly recovered, but a large portion of this element was removed by washing.  相似文献   

4.
Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for monitoring organic contaminants in groundwater was evaluated in a pilot field application in an area severely contaminated by chemical waste, especially by chlorinated hydrocarbons. The spatial distribution of hydrophobic groundwater contaminants was assessed using a combination of passive sampling with SPMDs and non-target semiquantitative GC-MS analysis. More than 100 contaminants were identified and semiquantitatively determined in SPMD samples. Along the 6 field sites under investigation, a large concentration gradient was observed, which confirms a very limited mobility of hydrophobic substances in dissolved form in the aquifer. The in situ extraction potential of the SPMD is limited by groundwater flow, when the exchange volume of well water during an exposure is lower than the SPMD clearance volume for the analytes. This study demonstrates that SPMDs present a useful tool for sampling and analyzing of groundwater polluted with complex mixtures of hydrophobic chemicals and provides guidance for further development of passive sampling technology for groundwater.  相似文献   

5.
Passive sampling devices have been used since the 1970s to measure time-weighted average (TWA) or equilibrium concentrations of pollutants in various environmental matrices (e.g. air, soils and sediments and water). In recent years the popularity of using such samplers has increased and the technology in now well established for the measurement of atmospheric pollutants. This sector has a long experience of using passive samplers in the short- and long-term assessment of air quality in the local environment and on a global scale (e.g. within the United Nations Stockholm Convention on the trans-boundary movement of persistent organic pollutants (POPs) where large networks of samplers on a continental scale have been established). In comparison, the use of passive samplers for monitoring the aquatic environment has been slower to take off. There has, however, been a recent research drive to develop devices for measuring the wide range of pollutants that can be found in environmental waters (e.g. ground, surface, and marine). It is now being recognised that passive samplers can play a valuable role in monitoring water quality within a legislative framework such as the European Union's Water Framework Directive (WFD). The data from these devices can be used alongside the results obtained from conventional spot or bottle sampling to improve risk assessments and to inform decisions on undertaking potentially expensive remedial actions. Such monitoring techniques may have uses within the European Registration, Evaluation, Authorisation & restriction of CHemicals (REACH) Directive and the forthcoming European Marine Strategy Directive. It is expected that the aquatic monitoring sector will follow a transition similar to that which occurred in air monitoring where data obtained from passive samplers can use used within a legal framework. There has also been increased interest in extending the role of passive samplers to both the measurement of equilibrium concentrations and investigating the movement and release of the dissolved fraction of various pollutants in the pore water of sediments and soils.  相似文献   

6.
The objectives of this study are to investigate the volatile organic compound (VOC) distribution using passive samplers and to assess the resulting health risks in a high-tech science industrial park. With the advantages of passive sampling techniques, long-term and wide-area samples are collected. The results show TVOC concentrations in summer, fall, winter, and spring are 7.14?±?5.66 ppb, 18.17?±?5.81 ppb, 10.30?±?3.54 ppb, and 14.56?±?4.53 ppb, respectively; those on weekdays and weekends are 14.36?±?6.80 ppb and 9.87?±?4.86 ppb, respectively; and those in industrial and residential zones are 12.97?±?0.39 ppb and 11.13?±?0.68 ppb, respectively. Based on concentration variations, and benzene, toluene, ethylbenzene, and xylene ratios, we can resolve the source origins. Health risks are assessed based on the resulting concentrations. In the case of non-cancer chronic effects, long-term exposure to these concentrations does not support there is a risk of adverse health effects. However, potential cancer risks of exposure to these concentrations may occur, especially to carbon tetrachloride and benzene. By applying this study’s procedures, information on VOC concentration distribution, source identification, and health assessment can be obtained and they are applicable to similar studies.  相似文献   

7.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

8.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

9.
Diffusive samplers for monitoring of air quality are user-friendly devices that can normally be operated by the user himself. Hence these samplers are suitable for self-assessment. Practical and work organisational aspects of self-assessment of chemical exposure were studied in different occupational settings. It was found that the diffusive sampler used in these studies, the Perkin-Elmer tube in combination with thermal desorption, worked well for the purpose and could be correctly handled by the individuals using it. The results from self-assessments agreed well with expert measurements carried out by an occupational hygienist. However, in order to obtain a sustainable system of self-assessment strong organizational support is needed.  相似文献   

10.
Passive samplers are often employed to measure ozone concentrations in remote areas such as mountain forests. The potential ozone risk for vegetation is then assessed by calculating the AOT40 exposure index (accumulated hourly ozone concentration exceedances above 40 ppb, i.e. AOT40 = Σ([O(3)] - 40)Δt for any hourly ozone concentration [O(3)] > 40 ppb). AOT40 is customary calculated on the basis of ozone concentrations expressed as a volumetric mixing ratio, while lab sheets normally report ozone concentrations from passive samplers in mass units per cubic metre. Concentrations are usually converted from mass units to ppb using a standard conversion factor taking SATP (Standard Ambient Temperature and Pressure) conditions into account. These conditions, however, can vary considerably with elevation. As a consequence, the blanket application of a standard conversion factor may lead to substantial errors in reporting and mapping ozone concentrations and therefore in assessing potential ozone risk in mountain regions. In this paper we carry out a sensitivity analysis of the effects of uncertainties in estimations of air temperature (T) and atmospheric pressure (P) on the concentration conversion factor, and present two examples from two monitoring and mapping exercises carried out in the Italian Alps. We derived P and T at each site from adiabatic lapse rates for temperature and pressure and analysed the magnitude of error in concentration estimations. Results show that the concentration conversion is much more sensitive to uncertainties in P gradient estimation than to air temperature errors. The concentration conversion factor (cf) deviates 5% from the standard transformation at an elevation of 500 m asl. As a consequence, the standard estimated AOT40 at this elevation is about 13% less than the actual value. AOT40 was found to be underestimated by an average between 25% and 34% at typical elevations of mountain forest stands in the Italian Alps when a correct conversion factor for transforming ozone concentrations from μg m(-3) to ppb is not applied.  相似文献   