1.
Dechlorination of a nonachloro biphenyl congener with zero-valent iron in water under high temperature and pressure was investigated over time. Temperature has the main influence on the speed of dechlorination. Determination of polychlorinated biphenyls (PCBs) according to the grade of chlorination was performed by gas chromatography with mass selective detection in single ion monitoring mode. Dechlorination results in a variety of lower chlorinated biphenyls. The level of chlorination decreases with time. The amount of PCB molecules decreases to one-third within 90 min at 250 degrees C and 100 atm. However, no increase of biphenyl could be detected over time. A first-order kinetic model fitted the data obtained.  相似文献   

2.
Electrical conductivity (EC) is widely used for monitoring the mixing of fresh water and saline water, separating stream hydrographs, and geophysical mapping of contaminated groundwater. The measured EC values at various temperatures need to be reported as corresponding to a standard temperature because EC is dependent on temperature. An arbitrary constant is commonly used for temperature compensation assuming that EC-temperature relation is linear (for example 2% increase of EC per 1 degrees C). This paper examines the EC-temperature relation of natural waters having vastly different compositions and salinities. EC-temperature relation was slightly nonlinear in a temperature range 0-30 degrees C, but the linear equation approximated the relation reasonably well. The temperature compensation factor corresponding to 25 degrees C ranged between 0.0175 and 0.0198. When the mean value 0.0187 was used, the error of estimating EC at 25 degrees C from EC at 10 degrees C was less than about 2% for all samples tested. Temperature compensation factors vary substantially depending on the choice of standard temperature. Therefore, a care must be taken when standard temperatures different from 25 degrees C are used.  相似文献   

3.
Corrosion deposits formed within drinking water distribution systems deteriorate drinking water quality and resultantly cause public health consequences. In the present study, an attempt was made to investigate the concurrent conditions of corrosion scales and the drinking water quality in selected water supply schemes (WSS) in districts Chitral, Peshawar, and Abbottabad, northern Pakistan. Characterization analyses of the corrosion by-products revealed the presence of α-FeOOH, γ-FeOOH, Fe3O4, and SiO2 as major constituents with different proportions. The constituents of all the representative XRD peaks of Peshawar WSS were found insignificant as compared to other WSS, and the reason could be the variation of source water quality. Well-crystallized particles in SEM images indicated the formation of dense oxide layer on corrosion by-products. A wider asymmetric vibration peak of SiO2 appeared only in Chitral and Abbottabad WSS, which demonstrated higher siltation in the water source. One-way ANOVA analysis showed significant variations in pH, turbidity, TDS, K, Mg, PO4, Cl, and SO4 values, which revealed that these parameters differently contributed to the source water quality. Findings from this study suggested the implementation of proper corrosion prevention measures and the establishment of international collaboration for best corrosion practices, expertise, and developing standards.  相似文献   

4.
太湖微囊藻毒素与湖泊物理因素之间的关系   总被引:7,自引:0,他引:7  
应用酶联免疫吸附法(ELISA)监测了太湖2001年的微囊藻毒素的周年变化,探讨了微囊藻毒素浓度(Microcystin-LR,MCLR)和水温、光照、悬浮质、溶解氧、风浪等湖泊物理因素之间的关系,显示微囊藻毒素在夏秋季节较高,但各采样点微囊藻毒素浓度的最高值及其变化趋势与各采样点所处地理位置,水动力学变化及样点周围水域藻类生长情况等有密切关系,从湖泊物理因素来看,微囊藻毒素浓度受风浪和水温的影响较大。  相似文献   

5.
松花江哈尔滨段流域是哈尔滨市重要的水源地,也是松花江重要的组成部分,其生态环境问题一直受到国内外学者密切关注,且近年来松花江哈尔滨段水体改善程度较为明显,流域内水体变化程度越来越受到相关学者和民众的重视,研究松花江哈尔滨段水体变化趋势意义明显。该研究的创新性在于运用典范对应分析(CCA)探究藻类植物与环境因子变化的关系,并运用欧洲硅藻数据库(EDDI)验证主要环境因子的准确性。国内现行的一些常规理化指标单独评价水体质量较为单一,不能更好地满足现行的水环境管理要求,并且对于水环境的变化反应效果及准确度较低。该研究运用相关理化指标数据和藻类植物的种类及丰度等的年际变化,实现从单一理化指标评价改善为理化和生物指标双重评价,从而更加具体地反映出松花江哈尔滨段水体状况的变化趋势。  相似文献   

6.
以辽宁棕壤等10种土壤为样品,探讨了水和p H值=9.00~14.00的氢氧化钠(Na OH)作为提取液对草甘膦分析的影响。结果表明,以水为提取液,仅石灰性紫色土和灰钙土能获得较高的回收率,其他所测土壤尤其是p H值<8.00的土壤其回收率较低,提取效果受土壤理化性质影响明显。以p H值=9.00~14.00的Na OH为提取液,随着提取液p H值的提高,所测土壤的回收率均随之提高,达到一定的p H值后,回收率随之提高不明显,但干扰会增多。当已知土壤相关理化性质时,可以参考回收率相关性分析选择合适的提取液。  相似文献   

7.
A suite of twelve assays has been used to 'fingerprint' dissolved organic matter (DOM). The assays were applied directly to filtered natural water samples. Temperature, pH and conductivity accounted for the environmental conditions on-site. Bulk carbon characteristics were assayed by measuring UV absorbance at 200 and 240 nm, colour in grade Hazen, DOC (dissolved organic carbon), fluorescence (excitation 370 nm, emission 450 nm) and the complexation of phenol itself. Measuring hydroxybenzenes ('monophenolics'), polyhydroxybenzenes ('polyphenolics') and total phenolics with the Gibbs, Prussian Blue and Folin-Ciocalteau assays, respectively, determined the phenolics pool. The methodology was tested on six freshwater sites in North Wales chosen to provide differences in vegetation, land-use and water chemistry and sampled once during each season. A novel approach for the presentation of the data has been developed that combines all range normalised assay results for each site and each season within one polar plot, hence the term 'fingerprint'. The data was also analysed using principal component factor analysis. Assays characterised as determining the chemical properties of DOM contributed to Factor 1 and explained 59% of the variation in the data. Assays apparently determined by the water matrix, contributed to Factor 2 and explained 20% of the variation within the data. The factor scores obtained for each site showed more variation for assays relating to the chemical properties of DOM than to the surrounding water matrix. The methodology was found to detect chemical changes within DOM for each site throughout the year and different responses for different sites.  相似文献   

8.
以污水厂长序列运行数据为基础,反推脱氮实际影响因素,开展反硝化脱氮试验。结果表明,在2019年4月前后TN出水平均浓度降低58%;受季节和污水厂升级改造影响,温度由15℃升高至25℃,混合液悬浮固体质量浓度(MLSS)由4300 mg/L增至8000 mg/L,活性污泥成分增加,脱氮效果提升;BOD 5/TN和pH值等变化相对稳定,温度、MLSS是影响该污水处理厂反硝化脱氮的主要因素;当反应温度为(25±5)℃,pH值为7.5±0.2,MLSS为4800 mg/L时,反硝化脱氮效果最佳,硝酸盐氮去除率达91%。  相似文献   

9.
Assessing the behaviour of organic chemicals in soil is a complex task as it is governed by the physical chemical properties of the chemicals, the characteristics of the soil as well as the ambient conditions of the environment. The chemical partitioning space, defined by the air-water partition coefficient (K(AW)) and the soil organic carbon-water partition coefficient (K(OC)), was employed to visualize the equilibrium distribution of organic contaminants between the air-filled pores, the pore water and the solid phases of the bulk soil and the relative importance of the three transport processes removing contaminants from soil (evaporation, leaching and particle erosion). The partitioning properties of twenty neutral organic chemicals (i.e. herbicides, pharmaceuticals, polychlorinated biphenyls and volatile chemicals) were estimated using poly-parameter linear free energy relationships and superimposed onto these maps. This allows instantaneous estimation of the equilibrium phase distribution and mobility of neutral organic chemicals in soil. Although there is a link between the major phase and the dominant transport process, such that chemicals found in air-filled pore space are subject to evaporation, those in water-filled pore space undergo leaching and those in the sorbed phase are associated with particle erosion, the partitioning coefficient thresholds for distribution and mobility can often deviate by many orders of magnitude. In particular, even a small fraction of chemical in pore water or pore air allows for evaporation and leaching to dominate over solid phase transport. Multiple maps that represent soils that differ in the amount and type of soil organic matter, water saturation, temperature, depth of surface soil horizon, and mineral matters were evaluated.  相似文献   

10.
采用统计学方法对新疆某污水处理厂A2/O工艺进行进水水质数据分析,发现数据存在严重自相关现象,运用主成分消除法和岭回归消除法以消除自相关性。结果表明:TN和TP是污水厂提标改造的关键;碳源匮乏和缺氧区存在溶解氧(DO)是TN去除不佳的主要原因;适当提高污泥浓度(MLSS)和水力停留时间(HRT)是强化TP去除的措施;温度是影响脱氮除磷的主要因素。将温度模型与自相关磷模型相结合,可提高磷模型精度,有利于出水TP的预测。降低DO、增加外碳源,控制MLSS为3 500 mg/L~4 500 mg/L、HRT为5.4 h~8.0 h、厌氧区和好氧区DO为0.3 mg/L和2 mg/L、污泥龄(SRT)为11 d~12 d,可提升工艺脱氮除磷效果。  相似文献   

11.
张世军 《干旱环境监测》2010,24(1):31-33,38
通过监测和田地区生态修复项目实施后所取得生态效益的结果表明,生态修复项目实施后,由于项目区风速降低,温度和相对湿度的变化减少,提高了植被盖度,降低了风蚀量,促进了成土作用的进行,从而逐渐改善了土壤的理化性质。  相似文献   

12.
Big Melen stream is one of the major water resources providing 268 km3 year???1 of drinking and municipal water for Istanbul. Monthly time series data between 1991 and 2004 for 25 chemical, biological, and physical water properties of Big Melen stream were separated into linear trend, seasonality, and error components using additive decomposition models. Water quality index (WQI) derived from 17 water quality variables were used to compare Aksu upstream and Big Melen downstream water quality. Twenty-six additive decomposition models of water quality time series data including WQI had R 2 values ranging from 88% for log(water temperature) (P?≤?0.001) to 3% for log(total dissolved solids) (P?≤?0.026). Linear trend models revealed that total hardness, calcium concentration, and log(nitrite concentration) had the highest rate of increase over time. Tukey’s multiple comparison pointed to significant decreases in 17 water quality variables including WQI of Big Melen downstream relative to those of Aksu upstream (P?≤?0.001). Monitoring changes in water quality on the basis of watersheds through WQI and decomposition analysis of time series data paves the way for an adaptive management process of water resources that can be tailored in response to effectiveness and dynamics of management practices.  相似文献   

13.
Temperature measurements were taken at three pilot-scale facultative ponds located at Esholt wastewater treatment works in West Yorkshire, UK over two one-year periods. The measurements were taken at different depths using a technology called Thermochron iButton. The iButton readings were compared with temperature measurements taken by a YSI sonde probe and maximum/minimum thermometers: they were found to be within 1 .C. In the temperature range 3.18 .C the mean weekly and monthly air temperatures were found to be good predictors for the mean weekly and monthly pond water-column temperatures. The level of stratification in the ponds under UK climatic conditions was assessed; the data revealed that the ponds remained thermally stratified for significant periods during the year despite their shallow depth.  相似文献   

14.
Under a low temperature condition of 12°C, accumulation of copper by the ragworm, Hediste (Nereis) diversicolor, increased at low salinity of 7.6 but was reduced at intermediate and high salinities of 15.25 and 30.5, respectively. Copper contents of the worms at low salinity and temperature ranged from 68 to 185 µg/g. Under increasing temperature of 17 and 22°C, bioavailability of copper to the worms increased irrespective of salinity gradient. The copper contents of the worm ranged from 59 to 784 µg/g dry weight. ANOVA analysis of data showed that salinity did not significantly affect accumulation of copper by the worm. Temperature significantly affected accumulation. The interaction of salinity and temperature was significant and complex, and days of exposure did not influence accumulation. Depuration of copper by the worm was independent of salinity which ranged from 510 to 15.6 µg/g. Temperature significantly affected depuration. The interaction of salinity and temperature was significant. However, individual worms neither accumulated nor depurated at the same rate.  相似文献   

15.
Potable water samples (N?=?74) from 19 zip code locations in a region of Greece were profiled for 13 trace elements composition using inductively coupled plasma mass spectrometry. The primary objective was to monitor the drinking water quality, while the primary focus was to find novel associations in trace elements occurrence that may further shed light on common links in their occurrence and fate in the pipe scales and corrosion products observed in urban drinking water distribution systems. Except for arsenic at two locations and in six samples, rest of the analyzed elements was below maximum contaminant levels, for which regulatory values are available. Further, we attempted to hierarchically cluster trace elements based on their covariances resulting in two groups; one with arsenic, antimony, zinc, cadmium, and copper and the second with the rest of the elements. The grouping trends were partially explained by elements’ similar chemical activities in water, underscoring their potential for co-accumulation and co-mobilization phenomena from pipe scales into finished water. Profiling patterns of trace elements in finished water could be indicative of their load on pipe scales and corrosion products, with a corresponding risk of episodic contaminant release. Speculation was made on the role of disinfectants and disinfection byproducts in mobilizing chemically similar trace elements of human health interest from pipe scales to tap water. It is warranted that further studies may eventually prove useful to water regulators from incorporating the acquired knowledge in the drinking water safety plans.  相似文献   

16.
Water corrosivity in Gdansk Bay, Poland, the southern part of the Baltic Sea, was investigated. The analysed region is heavily industrialized, and the coastline is very diverse. Twenty-seven test points along the coastline were selected. Water parameters such as salinity, total dissolved solids content, resistivity, conductivity, oxygenation, pH and corrosion rate were determined. The results of the investigation are presented. Water samples were collected, and structural steel specimens were exposed in the water for 2 months. The corrosion rate for each test point was determined and plotted on a map. The spatial distribution of water parameters was calculated using the ‘inverse distance to a power’ method and presented on the maps. Salinity did not exceed 0.7 %, and average corrosion rate equalled 0.0585 mm/year.  相似文献   

17.
Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.  相似文献   

18.
The large demand for drinking, irrigation and industrial water in the region of Torbali (Izmir, Turkey) is supplied from groundwater sources. Almost every factory and farm has private wells that are drilled without permission. These cause the depletion of groundwater and limiting the usage of groundwater. This study investigates spatial and temporal change in groundwater quality, relationships between quality parameters, and sources of contamination in Torbali region. For this purpose, samples were collected from 10 different sampling points chosen according to their geological and hydrogeological properties and location relative to factories, between October 2001 and July 2002. Various physical (pH, temperature, EC), chemical (calcium, magnesium, potassium, sodium, chloride, alkalinity, copper, chromium, cadmium, lead, zinc) and organic (nitrate, nitrite, ammonia, COD and cyanide) parameters were monitored. It was observed that the groundwater has bicarbonate alkalinity. Agricultural contamination was determined in the region, especially during the summer. Nitrite and ammonia concentrations were found to be above drinking water standard. Organic matter contamination was also investigated in the study area. COD concentrations were higher than the permissible limits during the summer months of the monitoring period.  相似文献   

19.
细菌在近海污染监测及评价中的应用研究   总被引:1,自引:0,他引:1  
通过对天津渤海湾的三个河流入海口(青静黄排水河、独流减河和海河),不同季节实地采集的水样中微生物数量及理化因子如温度、盐度、溶解氧(DO)、化学需氧量(COD)、无机氮等的研究,发现细菌指标与理化指标对污染指示结果有一定的相似性,都指示青静黄排水河河口污染较严重.利用SPSS软件的相关性分析方法对实验结果进行分析,发现水环境中细菌指标与理化因子具有一定的相关性.其中异养菌数与COD呈显著正相关性(P<0.05),与DO呈负相关性(P=0.051);大肠菌群数与理化因子DO呈极显著负相关关系(P<0.01),与COD呈正相关关系(P=0.061),与NO3-N,盐度呈负相关性(P>0.05).其他细菌指标与各理化因子也存在一定的相关性,但不明显.  相似文献   

20.
Water Quality Changes in Chini Lake, Pahang, West Malaysia   总被引:1,自引:0,他引:1  
A study of the water quality changes of Chini Lake was conducted for 12 months, which began in May 2004 and ended in April 2005. Fifteen sampling stations were selected representing the open water body in the lake. A total of 14 water quality parameters were measured and Malaysian Department of Environment Water Quality Index (DOE-WQI) was calculated and classified according to the Interim National Water Quality Standard, Malaysia (INWQS). The physical and chemical variables were temperature, dissolved oxygen (DO), conductivity, pH, total dissolved solid (TDS), turbidity, chlorophyll-a, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solid (TSS), ammonia-N, nitrate, phosphate and sulphate. Results show that base on Malaysian WQI, the water in Chini Lake is classified as class II, which is suitable for recreational activities and allows body contact. With respect to the Interim National Water Quality Standard (INWQS), temperature was within the normal range, conductivity, TSS, nitrate, sulphate and TDS are categorized under class I. Parameters for DO, pH, turbidity, BOD, COD and ammonia-N are categorized under class II. Comparison with eutrophic status indicates that chlorophyll-a concentration in the lake was in mesotrophic condition. In general water quality in Chini Lake varied temporally and spatially, and the most affected water quality parameters were TSS, turbidity, chlorophyll-a, sulphate, DO, ammonia-N, pH and conductivity.  相似文献   