首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 79 毫秒
1.
于2015年对苏州市太湖东岸饮用水主要异味物质进行了调查。结果表明,主要异味物质为土臭素、2-甲基异莰醇、β-环柠檬醛、β-紫罗兰酮等,检出率分别50.0%,66.7%,70.8%和66.7%,其中2-甲基异莰醇年均值是其嗅觉阈值的2.31倍,其他异味物质年均值未超过其阈值,水体主要表现为土霉味。异味问题爆发时间为夏季(5—9月),土臭素、2-甲基异莰醇、β-环柠檬醛、β-紫罗兰酮检出最高值分别为13.8,170,170和29.6 ng/L。分析了异味物质与环境因子的相关性,初步推断太湖主要异味物质为水中蓝藻的某些种类所致。  相似文献   

2.
通过对萃取和解吸条件进行优化,实现搅拌棒吸收萃取(SBSE)-热脱附-气相色谱/质谱联用以同时测定饮用水源水中16种多溴联苯单体。此法在2~50 ng/L范围内线性良好,取10 m L水样,搅拌棒吸收萃取1 h后,16种多溴联苯单体的检出限为0.5~1.1 ng/L。对实际水样进行2个质量浓度的加标回收,平均回收率为89.2%~102%。  相似文献   

3.
建立了测定水中痕量2-甲基异莰醇(2-MIB)和土臭素(GSM)的顶空固相微萃取-气相色谱/二级质谱联用法(HS/SPME-GC/MS/MS),并对HS/SPME条件进行优化。优化后的方法 2-MIB和GSM在1.00~50.0 ng/L范围内,线性良好(r≥0.999 4),RSD分别为7.36%和7.75%,方法检出限分别为0.226和0.239 ng/L,加标回收率分别为87.0%~97.0%和85.2%~112%。结果表明,所建立的方法操作简便、准确度高、重现性好、灵敏度高,无需有机溶剂,适用于水中痕量2-MIB和GSM的测定。  相似文献   

4.
采用顶空固相微萃取-气相色谱/质谱联用测定技术,以太湖某饮用水源地水体中甲基异莰醇-2和土臭素为主要研究对象,通过环境因子相关性分析,对异味物质的变化规律和来源作初步分析。研究结果表明,该水源地2013年的主要异味物质为甲基异莰醇-2,超标时段主要集中在夏秋高温季节(5—9月);水体中的硅藻可能是异味物质的重要产生者,底泥中的藻类和微生物次生代谢活动可能是水体产生异味的主要原因。  相似文献   

5.
采用固相微萃取法富集,气相色谱-质谱联用法定性和定量测定饮用水中致嗅物质土嗅素和2-甲基异茨醇。研究并讨论优化了纤维头的类型、盐的种类和浓度、温度、萃取时间等因素对异味化合物萃取量的影响。土嗅素和2-甲基异茨醇的检出限分别为1.02、2.13 ng/L,相对标准偏差分别为4.96%、7.74%。2种异味化合物在5~1 000 ng/L的范围内线性关系良好,相关系数均大于0.985。因此,用该方法能够很好地分析水中痕量的异味化合物。  相似文献   

6.
采用C18固相膜萃取对地下水中15种多环芳烃进行富集净化,以二氯甲烷作洗脱溶剂,高效液相色谱法,荧光检测器测定。对萃取、浓缩和色谱条件进行优化,在1.ooixg/L~40.0μg/L范围内测定标准系列溶液并绘制标准曲线,相关系数R2〉0.999;15种多环芳烃的仪器检出限为0.4ng/L~3.0ng/L;对地下水样品加标,平均回收率在75.7%~96.7%之间;标准溶液平行测定7次的RSD为3.1%~11.9%。  相似文献   

7.
研究了顶空固相微萃取-气相色谱质谱联用测定饮用水中二甲基异冰片和土味素的方法。结果表明,当选用聚二甲基硅氧烷(PDMS)萃取纤维萃取头,萃取温度为60℃,萃取时间为40min时,得到二甲基异冰片标准曲线方程为y=122.59+157.76x,相关系数(R)0.9998;土味素的标准曲线方程为y=14.847+180.99x,相关系数(R)0.9999;检出限为0.1ng/L,相对标准偏差在0.99%~4.05%之间,加标回收率86.4%~109.5%。  相似文献   

8.
SBSE-GC/MS法测定饮用水源水中7种多氯联苯单体   总被引:2,自引:0,他引:2  
采用搅拌棒吸收萃取(SBSE)-溶剂解吸-气相色谱/质谱联用法测定饮用水源水中7种多氯联苯单体,优化了萃取和解吸条件。方法在5 ng/L~100 ng/L范围内线性良好(r≥0.979),7种多氯联苯单体的检出限为0.8 ng/L~3.4 ng/L(100 mL水样SBSE萃取2 h),加标10 ng/L时实际水样回收率为93.0%~116%。  相似文献   

9.
采用固相萃取法处理水样,气相色谱-高分辨双聚焦磁质谱法测定水中超痕量多氯萘,同位素内标法定量,并对样品前处理条件和仪器条件进行优化。试验表明:方法在0.500 ng/L~500 ng/L范围内线性良好;当取样体积为1 L时,方法检出限为0.005 ng/L~0.01 ng/L;对实际水样进行2个质量浓度水平的加标回收试验,平行测定6次的 RSD为2.7%~8.7%,回收率为70.2%~110%。方法适用性试验表明,水样中复杂的基质对测定无影响。  相似文献   

10.
采用二氯甲烷提取地表水,浓缩后经超高效液相色谱紫外-三重四级杆质谱检测器联用测定甲萘威。试验表明:紫外检测器测定甲萘威,在2.00μg/L~500μg/L范围内线性良好,相关系数为0.9992,检出限为0.500μg/L;三重四级杆质谱检测器测定甲萘威,在0.100μg/L~200μg/L范围内线性良好,相关系数为0.9990,检出限为0.009μg/L;实际水样3个浓度水平的加标回收率为92.4%~98.4%,RSD为2.5%~6.5%。该方法中双检测器联用测定地表水加标样品,使得定性定量更加准确。  相似文献   

11.
Two common drinking water earthy/musty odorants, 2-methyl-isoborneol (2-MIB) and trans-1,10-dimethyl-trans-9-decalol (geosmin), were monitored and analyzed for their correlation with environmental conditions in Feng-Shen Reservoir (FSR), Taiwan. Long-term monitoring results, from December 2000 to July 2003, indicated that 2-MIB was present in the reservoir at concentrations between 10 and 200 ng L(-1), and those of geosmin were always smaller than 10 ng L(-1). The 2-MIB concentrations followed a trend of higher concentrations during the warm seasons. After being analyzed with 10 water quality and three meteorological parameters, 2-MIB concentration was found to correlate with corresponding air and water temperatures. An analysis of air temperature history versus 2-MIB concentration in FSR suggested that 2-MIB concentration was best correlated with the mean of average daily temperature from 1 to 9 days before sampling, with R (2) = 0.90. This correlation was further employed to predict the 2-MIB concentration observed during another sampling period in FSR. A similar degree of fit was observed between predictions and experimental data, suggesting the potential applicability of the approach. In addition to the effect of temperature, heavy rainfalls that occurred before the sampling time may also reduce the 2-MIB concentration in the reservoir. A short-term continuous monitoring of the odorants for 32 h showed that both geosmin and 2-MIB concentrations in the reservoir remained almost constant, with only about a 10% difference during the sampling period. This may suggest that the odorants were uniformly distributed in the water near the sampling location in the reservoir.  相似文献   

12.
三重四极杆质谱技术测定固体废弃物中多氯联苯   总被引:1,自引:0,他引:1  
以二氯甲烷为萃取剂,采用快速溶剂萃取、凝胶渗透色谱净化、三重四极杆质谱技术测定固体废弃物中7种多氯联苯单体,选择十氯联苯为内标物,2,4,5,6-四氯间二甲苯为替代物。质谱采用MRM扫描,优化了目标物质保留时间、母离子和子离子质量数及碰撞能量等参数。方法在0.050 mg/L~2.00 mg/L范围内线性良好,7种多氯联苯单体的检出限为0.194 ng/g~0.355 ng/g(以称取30 g样品、定容至2.0 mL计),标准样品回收率多在60%~105%之间,空白加标样品测定值的相对标准偏差在8.6%~13.0%之间。  相似文献   

13.
采用毛细管柱气相色谱氢火焰离子化检测器测定环境空气中的樟脑,选择硅胶为吸附剂,甲醇/丙酮混合溶剂(体积比90∶10)为解析剂.方法在0.544 mg/L~109 mg/L范围内线性良好,检出限为0.06 mg/L,当采样体积为20 L时,最低检出质量浓度为0.003 mg/m3,标准溶液平行测定的RSD≤3.8%,空白...  相似文献   

14.
采用固相萃取-高效液相色谱-电喷雾电离质谱法测定饮用水源地地表水中痕量微囊藻毒素MC-LR,优化了色谱和质谱条件,以甲醇/水(含0.1%甲酸)混合溶液(体积比60:40)为流动相,选择定量离子质荷比(m/z)996.3.方法在0.100 mg/L-2.00 mg/L范围内线性良好,检出限为0.02 μg/L,空白水样加...  相似文献   

15.
采用顶空固相微萃取(HS -SPME)技术萃取水中6种氯苯类化合物,全面分析对目标物萃取效率的影响因素,并确定萃取试验的最佳条件。用顶空固相微萃取联合气相色谱法(HS -SPME -GC)测定水中6种氯苯类化合物,方法在0.500 ng/L~2.00×10^5 ng/L范围内线性良好,检出限为0.05 ng/L ~2000 ng/L,空白样品加标回收率为69.8%~121%, RSD为4.8%~18.3%。用该方法测定实际水样,平行双样的相对偏差低于20%。  相似文献   

16.
固相萃取-GC/MS法测定水中16种有机氯农药   总被引:1,自引:0,他引:1  
采用HLB固相萃取柱富集水样,乙酸乙酯溶剂洗脱,加入氘代菲作为内标,利用气相色谱/质谱联用法选择离子模式测定水中16种有机氯农药,优化了固相萃取条件。16种有机氯农药在5.00μg/L~250μg/L范围内线性良好,按1 L水样计算,方法最低检出限为1.4 ng/L~19.4 ng/L,相对标准偏差为3.5%~20.0%,平均加标回收率为44.7%~119%。  相似文献   

17.
采用超高效液相色谱-串联质谱法测定水中痕量双酚A,水样经预处理后,以BEH C18超高效液相色谱柱分离,在质谱电喷雾离子源负离子多反应监测模式下测定.方法在0.200μg/L~10.0μg/L范围内线性良好,相关系数r为0.9992,方法检出限为0.06μg/L,空白及实际样品加标回收率为87.4% ~114%,RSD为3.6% ~7.4%.  相似文献   