首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 234 毫秒
1.
In a previous study, the efficacy of commercial and prototype impactors for sampling diesel particulate matter (DPM) in coal mines was investigated. Laboratory and field samples were collected on quartz-fiber filters and analyzed for organic and elemental carbon. Coal dust contributed a minimal amount of elemental carbon when commercial cascade impactors and prototype impactors, designed by the University of Minnesota (UMN) and the US Bureau of Mines (BOM), were used to collect submicrometer dust fractions. Other impactors were not as effective at excluding coal dust. The impactors evaluated in that study were either not commercially available or were multi-stage, expensive, and difficult to use for personal measurements. A commercial version of the BOM impactor, called the DPM Cassette, was recently introduced by SKC. Tests were conducted to evaluate the performance of the DPM Cassette for measuring diesel-source elemental carbon in the presence of coal dust. Bituminous coals from three mines in two different coal provinces were examined. The dust particle diameters were small and the coal dust contained a high percentage of carbon, thereby giving a worst-case condition for non-anthracite coal mines. Results for the DPM Cassette were essentially identical to those obtained by the BOM impactors in a previous study. At a respirable coal dust concentration of 5.46 mg m(-3), which is 3.8 times the regulatory limit, the DPM Cassette collected only 34 microg m(-3) of coal-source elemental carbon.  相似文献   

2.
It is commonly agreed that automobile exhaust has been the most important source of Pb pollution in urban areas, and that Cd may come from wear and tear of tyres. This study evaluates the fall in Pb concentrations in road dusts in Manchester as a consequence of the removal of Pb from petrol in January 2000. In the work presented here a slurry graphite furnace atomic absorption methodology for the determination of Pb and Cd in road dusts has been developed and is compared with an acid digestion method in terms of efficiency. The reproducibility and accuracy of the results obtained by acid digestion and the slurry method have been studied and a certified reference material CRM 038 was analysed to confirm the reliability of the proposed methods. Different factors were evaluated throughout this work including: (i) the effect of traffic density on Pb and Cd levels in road dust samples collected weekly during the period of May 1999 until September 2000; (ii) comparison between the Pb and Cd levels in a busy road and a residential street; (iii) the effect of distance from the source on Pb and Cd levels; The results of these experiments show a reduction in Pb levels over the sampling period. The relationship between road dust particle size and Pb and Cd concentration was also investigated in the 4-250 microns size range using the slurry method, showing that there is a relationship between metal concentration and particle size; the highest concentrations being for the smallest particle size.  相似文献   

3.
Epidemiological research has demonstrated the relationship between exposure to quartz dust and an elevated risk of pneumoconiosis and possible elevated risk of cancer. The current study was designed to evaluate the biological responses of workplace particles containing crystalline silica using an in vitro cell test. Respirable particle samples were sampled from four tin mines, where the standardized mortality ratio (SMR) for pneumoconiosis was 51.6 and SMR for lung cancer was 2.2 in dust-exposed miners. Alveolar macrophages (AM) are considered as the target cells for primary dust effects. The samples were then measured at 15, 30, 60 and 120 microg particle per 10(6) AM for cytoxicity with the release of glucuronidase, lactate dehydrogenase, for reactive oxygen damage with H(2)O(2) release, and for ability to induce fibrosis using the secretion of tumor necrosis factor-alpha (TNF-alpha). Pure quartz (DQ12) and corundum were used as controls. The results showed the samples from tin mines caused a higher cytoxicity when compared to corundum, yet lower when compared to quartz. However, reactive oxygen species release (148-177 nmol/3 x 10(5) AM in high concentration of 120 microg/10(6) AM) induced by the samples were significantly higher than that induced by quartz (57 nmol/3 x 10(5) AM) and corundum (62 nmol/3 x 10(5) AM). Furthermore, particle samples induced higher TNF-alpha secretion than corundum, the samples from Limu tin mine induced much higher TNF-alpha levels than that induced by DQ12 quartz. The results from the in vitro tests help elucidate the degree of hazard of dust particles in tin mines. The in vitro reaction patterns of AM also constitute a powerful tool to monitor biological and pathogenic responses of humans following dust particle exposure.  相似文献   

4.
A method has been described previously for determining particle size distributions in the inhalable size range collected by personal samplers for wood dust. In this method, the particles collected by a sampler are removed, suspended, and re-deposited on a mixed cellulose-ester filter, and examined by optical microscopy to determine particle aerodynamic diameters. This method is particularly appropriate to wood-dust particles which are generally large and close to rectangular prisms in shape. The method was used to investigate the differences in total mass found previously in studies of side-by-side sample collection with different sampler types. Over 200 wood-dust samples were collected in three different wood-products industries, using the traditional 37 mm closed-face polystyrene/acrylonitrile cassette (CFC), the Institute of Occupational Medicine (IOM) inhalable sampler, and the Button sampler developed by the University of Cincinnati. Total mass concentration results from the samplers were found to be in approximately the same ratio as those from traditional long-term gravimetric samples, but about an order of magnitude higher. Investigation of the size distributions revealed several differences between the samplers. The wood dust particulate mass appears to be concentrated in the range 10-70 aerodynamic equivalent diameter (AED), but with a substantial mass contribution from particles larger than 100 microm AED in a significant number of samples. These ultra-large particles were found in 65% of the IOM samples, 42% of the CFC samples and 32% of the Button samples. Where present, particles of this size range dominated the total mass collected, contributing an average 53% (range 10-95%). However, significant differences were still found after removal of the ultra-large particles. In general, the IOM and CFC samplers appeared to operate in accordance with previous laboratory studies, such that they both collected similar quantities of particles at the smaller diameters, up to about 30-40 [micro sign]m AED, after which the CFC collection efficiency was reduced dramatically compared to the IOM. The Button sampler collected significantly less than the IOM at particle sizes between 10.1 and 50 microm AED. The collection efficiency of the Button sampler was significantly different from that of the CFC for particle sizes between 10.1 and 40 microm AED, and the total mass concentration given by the Button sampler was significantly less than that given by the CFC, even in the absence of ultra-large particles. The results are consistent with some relevant laboratory studies.  相似文献   

5.
In the absence of methods for determining particle size distributions in the inhalable size range with good discrimination, the samples collected by personal air sampling devices can only be characterized by their total mass. This parameter gives no information regarding the size distribution of the aerosol or the size-selection characteristics of different samplers in field use conditions. A method is described where the particles collected by a sampler are removed, suspended, and re-deposited on a mixed cellulose-ester filter, and examined by optical microscopy to determine particle aerodynamic diameters. This method is particularly appropriate to wood dust particles which are generally large and close to rectangular prisms in shape. Over 200 wood dust samples have been collected in three different wood-products industries, using the traditional closed-face polystyrene/acrylonitrile cassette, the Institute of Occupational Medicine inhalable sampler, and the Button sampler developed by the University of Cincinnati. A portion of these samples has been analyzed to determine the limitations of this method. Extensive quality control measures are being developed to improve the robustness of the procedure, and preliminary results suggest the method has an accuracy similar to that required of National Institute for Occupational Safety and Health (NIOSH) methods. The results should provide valuable insights into the collection characteristics of the samplers and the impact of these characteristics on comparison of sampler results to present and potential future limit values. The NIOSH Deep South Education and Research Center has a focus on research into hazards of the forestry and associated wood-products industry, and it is hoped to expand this activity in the future.  相似文献   

6.
The aim of this study was to compare the personal exposure to particles and bioaerosols with that measured by stationary samplers in the main microenvironments, i.e., the home and the workplace. A random sample of 81 elementary school teachers was selected from the 823 teachers working for two councils in eastern Finland for the winter time measurement period. Bioaerosol and other particles were collected on filters by button samplers using personal sampling and microenvironmental measurements in homes and workplaces. The 24-hour sampling period was repeated twice for each teacher. Particle mass, absorption coefficient of the filter and the concentration of viable and total microorganisms were analyzed from each filter. In this paper, the study design, quality assurance principles and results of particle and bioaerosol exposure are described. The results show that particle mass concentrations, absorption coefficient and fungi were higher in personal exposure samples than in home and workplace samples. Furthermore, these concentrations were usually lower in the home than in the workplace. Bacterial concentrations were highest in heavily populated workplaces, while the viable fungi concentrations were lowest in workplaces. The fungi and bacteria results showed high variation, which emphasises the importance of quality assurance (duplicates and field blanks) in the microbial field measurements. Our results indicate that personal exposure measurements of bioaerosols in indoor environments are feasible and supplement the information obtained by stationary samplers.  相似文献   

7.
为了开展对我国沙暴传输规律的研究,了解我国北方干旱地区沙尘矿物特征有重要意义。本文对我国新疆塔克拉玛干沙漠区,内蒙腾格里沙漠区,贺兰山及银川等处的沙尘样品用X射线粉末衍射法进行矿物分析鉴定,并用原子吸收法作了特征元素的分析对比,根据矿物的X射线粉末衍射结果,结合元素分析,对沙漠源区及其以东地区沙尘矿物特征作了比较,判析了两个源区的矿物组成,讨论了它们的传输过程。  相似文献   

8.
The majority of particles that adhere to hands are <63 μm in diameter yet risk assessments for soil remediation are typically based on soil samples sieved to <250 μm. The objective of our study was to determine if there is a significant difference in metal concentration by particle size in both house dust and soil. We obtained indoor dust and yard soil samples from 10 houses in Tucson, Arizona. All samples were sieved to <63 μm and 63 to <150 μm and analyzed for 30 elements via ICP-MS following nitric acid digestion. We conducted t-tests of the log-transformed data to assess for significant differences that were adjusted with a Bonferroni correction to account for multiple comparisons. In house dust, significant differences in concentration were observed for Be, Al, and Mo between particles sizes, with a higher concentration observed in the smaller particle sizes. Significant differences were also determined for Mg, Ca, Cr, Co, Cu, Ge, Zr, Ag, Ba, and Pb concentration in yard soil samples, with the higher concentration observed in the smaller particles size for each element. The results of this exploratory study indicate that current risk assessment practices for soil remediation may under estimate non-dietary ingestion exposure. This is of particular concern for young children who are more vulnerable to this exposure route due to their high hand mouthing frequencies. Additional studies with a greater number of samples and wider geographic distribution with different climates and soil types should be completed to determine the most relevant sampling practices for risk assessment.  相似文献   

9.
A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.  相似文献   

10.
A new analytical technique based on DRIFTS spectroscopy has been developed for the specific and sensitive determination of size-fractionated wood dust from 37 mm glass fiber filter samples collected with the Respicon sampler. A translational diffuse reflectance apparatus was modified to accept filter samples by incorporating a special filter holder in the sample stage and a clockwork motor to drive the translational stage during infrared scanning, thus providing an average analysis across the filter face. Filter samples were pre-treated with ethyl acetate to uniformly redeposit dust onto the filter and extract potential chemical interferences. Two absorbance maxima (1251 and 1291 cm(-1)), corresponding to the cellulose content of the wood, were suitable for quantitation of wood dust. Analysis of seven species of wood at 1291 cm(-1) showed an equivalent quantitative response for all species except maple. The response at 1251 cm(-1) was more variable across species but more sensitive for the softwoods. There was a statistically significant effect of particle size on the analytical response, so that analytical standards should be matched to the samples in terms of particle size distribution. Analytical limit of detection was approximately 0.08 mg of wood dust per sample with overall precision of about 6%. Comparison of DRIFTS and gravimetric analyses of 51 pure wood dust samples ranging from about 0.2 to 2 mg yielded a slope of 1.08 and r2 equal to 0.9. Other particulate contaminants common in the industrial wood processing industry showed little or no interference with the determination of wood dust by this method.  相似文献   