首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
采用高分辨电感耦合等离子体质谱法测定地下水中14种稀土元素,并选择Rh作内标,可消除测定中的质谱干扰和非质谱干扰,使方法在0μg/L~100μg/L范围内线性良好。方法检出限为0.002μg/L~0.005μg/L,实际水样的加标回收率为80.0%~117%,RSD为2.1%~3.8%。  相似文献   

2.
选用配备了2种不同检测器(电导检测器和直流安培检测器)的离子色谱仪对稀释后过0.22μm滤膜的水样进行分析。配备有直流安培检测器的离子色谱仪测定水中碘化物的方法在0.100~20.0μg/L范围内线性关系良好,相关系数(r)=0.9999,方法检出限为0.030μg/L,测定下限为0.120μg/L,样品加标回收率为95.0%~104%,相对标准偏差为1.06%~1.64%;配备有电导检测器的离子色谱仪测定水中碘化物的方法在20.0~2.00×105μg/L范围内线性关系良好,相关系数(r)=0.9995,方法检出限为2.00μg/L,测定下限为8.00μg/L,样品加标回收率为99.0%~110%,相对标准偏差为0.71%~3.12%。离子色谱-直流安培检测器法测定水中碘化物的方法准确度高、灵敏度高、精密度好,检出限相对较低,适用于测定ρ(碘化物)≤20.0μg/L的清洁水样;离子色谱-电导检测器法主要适用于测定ρ(碘化物)≥20.0μg/L的水样。  相似文献   

3.
采用吹扫捕集-气相色谱/质谱联用法测定水中的丙烯醛和丙烯腈,方法在5.00μg/L~200μg/L范围内线性良好,方法检出限分别为4.9μg/L和0.3μg/L。用该方法测定3个质量浓度水平的空白加标样,7次测定结果的RSD为2.8%~6.7%,加标回收率为90.4%~98.3%。用该方法测定某水库和某河流的地表水,丙烯醛和丙烯腈均未检出。  相似文献   

4.
为方便地表水中总微囊藻毒素(TMCs)的预警监测,探究提取MC-LR、MC-RR、MC-YR的不同快速前处理方法,建立同时测定3种TMCs的煮沸-过滤-UPLC-MS/MS法。该方法在0.006μg/L~50.0μg/L范围内线性良好,方法检出限为0.006μg/L~0.010μg/L,实际水样3个质量浓度水平的加标回收率为88.6%~108%,6次测定结果的RSD为2.6%~9.4%。  相似文献   

5.
采用液液萃取处理水样,用气相色谱-串联质谱法测定样品中五氯酚及其钠盐,通过优化测定条件,使方法在1.00μg/L~500μg/L范围内线性良好。检出限和定量限分别为1.00μg/L和5.00μg/L,空白水样五氯酚钠3个质量浓度水平的加标回收率为89.8%~98.4%,5次平行试验测定结果的RSD为5.5%~10.7%。  相似文献   

6.
采用顶空气相色谱质谱法(HS/GC-MS)对土壤中挥发性卤代烃进行了测定,优化了分析的顶空条件、气相色谱质谱分离条件。在优化条件下成功实现了24种挥发性卤代烃的分离,确定了分析方法的检出限、测定下限、精密度及回收率等质量控制参数。方法的检出限为0.8~4.4μg/kg,测定下限为3.2~17.6μg/kg。当加标量为100μg/kg和250μg/kg时,相对标准偏差分别为1.3%~12.6%和2.6%~8.7%,加标回收率分别为71.4%~126%和63.1%~121%。  相似文献   

7.
石墨炉原子吸收分光光度法测定地表水中的锑   总被引:1,自引:0,他引:1  
采用石墨炉原子吸收分光光度法测定地表水中的锑,优化了仪器测量参数,讨论了干扰离子的干扰。方法在0μg/L~100μg/L范围内线性良好,检出限为0.9μg/L,平行测定的RSD为1.3%~9.8%,加标回收率为97.9%~104%,标准样品的测定结果符合要求。  相似文献   

8.
采用固相萃取-氢火焰离子化检测器气相色谱法测定水中15种酞酸酯类化合物,通过试验优化前处理条件,使方法在0.500 mg/L~20.0 mg/L范围内线性良好,方法检出限为0.20μg/L~0.39μg/L。空白水样的加标回收率为66.6%~120%,试验6次结果的RSD为5.7%~12.5%。用该方法测定实际水样,加标回收率为66.8%~119%,6次测定结果的RSD为5.4%~11.8%。  相似文献   

9.
采用高效液相色谱法(HPLC)和高效液相色谱-三重四级杆质谱联用法(HPLC-MS/MS)测定地表水及饮用水中11种酚类化合物,通过优化测定条件,使HPLC法在0.020 mg/L~50.0 mg/L范围内,HPLC-MS/MS法在0.500μg/L~250μg/L范围内线性良好,方法检出限分别为0.005μg/L~0.031μg/L和0.005μg/L~1.56μg/L。未检出的实际样品加标回收率分别为57.2%~96.7%和81.3%~113%,RSD分别为1.5%~5.3%和3.9%~17.7%。  相似文献   

10.
用氢氧化钠处理水样,将水样中的三氯乙醛转化为三氯甲烷,用顶空-气相色谱/质谱联用法间接测定水中三氯乙醛,通过优化试验条件,使该方法在1.00μg/L~20.0μg/L之间线性良好,方法检出限为0.12μg/L。用该方法测定3个质量浓度水平的空白加标样,RSD为2.6%~4.4%,回收率为99.4%~101%。3批实际水样只有废水样检出三氯乙醛,实际水样加标回收率为76.2%~104%。  相似文献   

11.
萃取技术在环境样品预处理中的应用及发展   总被引:8,自引:0,他引:8  
对萃取技术包括传统技术以及新近发展起来的如固相萃取、固相微萃取、膜萃取、超临界流体萃取、微波萃取等技术在环境样品预处理方面的运用进行综述,分析各自的优缺点以及发展前景.  相似文献   

12.
The leaching tests, including the Toxicity Characteristic Leaching Procedure (TCLP), EDTA extraction and BCR sequential extractions before and after EDTA treatments, were performed on two specific soils to elucidate heavy metal-associated mineral fractions and general leachability. The TCLP illustrated the low leachability of heavy metals in soils from two sites. EDTA is a strong chelator and therefore had higher extraction efficiency compared to that of TCLP. The lower extraction percentages by EDTA for As and Sb were found compared to the other heavy metals derived from anthropogenic sources. Sequential extractions showed that the importance of acid-extractable, organically-bound and Fe–Mn oxide fractions was identified for anthropogenic heavy metals with the exception of As and Ni while the importance of residual fraction was identified for endogenous metals. Changes in sequential fractions of heavy metals after leaching with EDTA are very complex and it is difficult to generalize on which fraction was more mobile than the others. These combined results are helpful in elucidating the association of heavy metals to soil fractions and the mobility characteristics of heavy metals under certain environmental conditions.  相似文献   

13.
ASE萃取-SPE净化- HPLC法测定土壤中多环芳烃   总被引:5,自引:0,他引:5       下载免费PDF全文
建立了加速溶剂萃取-固相萃取净化-高效液相色谱测定土壤中16种多环芳烃的方法,优化了试验条件.方法线性关系良好,16种多环芳烃的检出限在0.412 ng/g~3.974 ng/g之间,空白加标试验的相对标准偏差在1.2%~12.7%之间,基质加标回收率在60.4%~126%之间.实际样品的测定结果表明该方法分离效果好,能够满足土壤分析的要求.  相似文献   

14.
研究了用超声波萃取城市污水处理厂污泥中动植物油和矿物油的方法,并与索氏提取法进行比较.结果表明,超声波萃取法对污泥中矿物油和动植物油测定操作简单快速,标样回收率高,精密度好.  相似文献   

15.
快速溶剂萃取红外分光光度法测定土壤中石油类   总被引:2,自引:1,他引:1  
研究快速溶剂萃取红外分光法对土壤中石油类的提取效果,并与超声波萃取红外分光法比较.结果表明,快速溶剂萃取对土壤中的石油类的回收率高,精密度好,方法快速简便.  相似文献   

16.
探讨了利用液相色谱分离,荧光检测器测定地表水中联苯胺的可行性。前处理方法对比验证了液液萃取法和固相萃取法。水样在碱性条件下(pH=11~12)进行提取,当提取体积为1.0 L时,液液萃取液相色谱荧光法检测,方法检出限为1.4 ng/L,定量下限为5.5 ng/L;固相萃取液相色谱荧光法检测,方法检出限为0.9 ng/L,定量下限为3.6 ng/L。分别对地表水、生活废水、工业废水3种不同水体进行基体加标试验,加标浓度为10.0、40.0、80.0 ng/L。结果显示,对于3种不同基体和不同加标浓度的水样,两种方法均有较好的准确性和重现性,方法回收率为80%~120%,相对标准偏差均小于20%,满足《地表水环境质量标准》(GB 3838—2002)中对联苯胺的监测需求。  相似文献   

17.
研究了加速溶剂萃取(ASE)、固相萃取柱净化(SPE)、高效液相色谱仪(HPLC)联合测定土壤中16种多环芳烃(PAHs)的分析方法,选择以正己烷/丙酮(1+1,V/V)作为ASE提取溶剂,提取液经SPE硅胶小柱净化,正己烷/二氯甲烷(1+1,V/V)进行洗脱,洗脱体积为10 m L,洗脱液经旋转蒸发浓缩至近干,过0.22μm有机滤膜,用乙腈定容至1 m L,最后用HPLC-紫外检测器对提取液中16种PAHs进行定量分析。土壤中16种PAHs的方法检出限为2.8~4.9μg/kg,加标回收率为81.9%~102%,相对标准偏差为2.5%~6.2%,完全满足土壤中PAHs分析的质量控制要求,该法稳定性好、准确度高、可操作性强,适合于土壤样品中16种PAHs的准确测定。  相似文献   

18.
区域土壤中氯苯类化合物测定及分布研究   总被引:1,自引:0,他引:1  
以区域内16个土壤样品为研究对象,采用超声波萃取法对样品中的氯苯类污染物进行提取,并用气相色谱仪分类和测定,以保留时间定性,外标法定量。结果表明,利用超声波提取土壤中氯苯类是可行的,并能够进行分类检出;预处理中提取的最佳、合理的溶剂为正己烷;实验还得出了11种氯苯类化合物在18min内全部流出的最佳色谱条件。检测数据显示区域土壤内主要氯苯类污染物为二氯苯、四氯苯和六氯苯。  相似文献   

19.
水中多种酚类化合物同步提取方法研究   总被引:1,自引:1,他引:0  
对水中14种酚类化合物的液液萃取过程进行研究,选取不同萃取溶剂体系、水样pH和盐析条件等多个对萃取效率有决定性影响的参数进行优化。通过上述条件的优化选择,实现了同步对包括低沸点的苯酚、一氯代酚及较难提取的甲基酚和硝基酚等14种不同类型酚类化合物最优的萃取,提取效率达到75.2%~110.3%。  相似文献   

20.
用氯仿多次萃取高浓度挥发酚,可提高试样中待测组分的萃取率,其测定结果准确度令人满意。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号