首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 275 毫秒
1.
建立了用活性炭作吸附剂、脱芳烃石油醚萃取、紫外分光光度法测定油烟挥发组分的方法。取家用抽油烟杯内的油烟气冷凝液加热到200C的样品萃取液作标准油品,在225nm处测紫外吸光值,绘制校准曲线,相关系数在0.986~0.999之间。实验样品分析结果表明,脱芳烃石油醚对样品中油烟挥发组分萃取率可达90%以上,样品测定重现率达76.7%。红外光谱分析标准油品挥发组分初步认定为烃类、卤代烃类、醇酚醚类、醛酮类、羧酸及其衍生物类、稠环杂环类和胺类等。  相似文献   

2.
随着城市餐饮行业的快速发展,餐饮源已逐渐成为大气挥发性有机物(VOCs)的主要来源之一。为深入了解广州市餐饮油烟的排放特征,科学制定广州市餐饮源的减排对策,在实验室搭建烹饪平台模拟烹饪过程,探讨不同油温、食用油种类和菜系类型对烹饪油烟排放VOCs组分的影响,并采集广州市典型商圈川菜馆、湘菜馆、粤菜馆、越南菜馆4家餐馆排放的餐饮油烟废气,利用气相色谱质谱仪分析研究4家餐馆油烟废气VOCs组分特征。结果表明:不同食用油、不同油温和不同菜系下所产生的VOCs浓度及组分特征存在较大差异。烹饪油烟VOCs的排放质量浓度与温度呈正相关。东南亚和川菜烹饪方式产生的油烟VOCs均以羰基化合物为主,而油炸类烹饪方式(炸薯条)则以羰基化合物和烷烃类同为主导。炸薯条、东南亚菜和川菜烹饪油烟VOCs的羰基化合物中,乙醛占比突出。乙醛在猪油油烟中占比最高(60.4%),其次是花生油(53%)。对比环境空气样品,部分醛类物质(丁烯醛、甲基丙烯醛、苯甲醛、戊醛和己醛)在餐饮油烟VOCs中均有检出。结合实验模拟和外场监测结果表明,静电式的油烟净化器可以有效去除乙醛。苯系物在餐饮油烟废气中检出浓度的最小值均高于周边环境样品。4家餐馆中仅湘菜馆的油烟废气中苯的致癌风险>10-4,有显著致致癌风险。建议应依据餐饮油烟VOCs关键组分和污染类型,对餐饮行业进行规范科学的管理。  相似文献   

3.
饮食业油烟监测方法比较   总被引:1,自引:0,他引:1  
饮食业的快速发展,对繁荣经济,方便、丰富人民群众的物质文化生活起到了较大的作用。但因该行业网点量遍布城区大街小巷,营业中带来的油烟污染问题也日益突出,已成为环保投诉的热点之一。饮食业油烟排放属间断地不连续排放,浓度往往时高时低,而现今的饮食业油烟监测方法对现场测试条件要求较高——样品需带回实验室分析,监测周期较长。因此,寻求一种适合于饮食业油烟监督检查监测和现场执法监测的方法,尤为重要。  相似文献   

4.
定型机废气中油烟监测方法探讨   总被引:1,自引:0,他引:1  
印染行业中定型机废气的主要污染物之一是其中的工业油烟,由于当前我国没有工业油烟排放监测分析的国家标准,在实际监测过程中主要参照饮食业油烟的监测方法,但是工业油烟和饮食业油烟之间存在性质等方面的较大差异,导致两者在监测过程中也存在区别。通过对定型机排放废气中油烟多次监测分析,探讨在当前条件下,符合定型机废气中油烟监测的方法。  相似文献   

5.
饮食业油烟排放及处理技术探讨   总被引:1,自引:0,他引:1  
通过对饮食业油烟污染现状分析,提议建立相关法律制度,并对其处理技术的发展趋势进行了探讨。  相似文献   

6.
介绍工业油烟测定原理、采样步骤、样品测定、计算等。  相似文献   

7.
定型机废气污染是当前环境投诉的热点之一,油烟污染是定型机废气的主要问题,我国尚无定型机废气监测分析的标准方法。本文参照《餐饮业油烟排放标准》(试行)(GB 18483-2001)中的方法,比较了餐饮业油烟废气和定型机油烟废气在成分、排放方式等方面的相同点和不同点,从采样方法、采样时间等对定型机油烟废气的监测分析进行了初探,确定了定型机油烟废气竣工验收参考的采样方法和时间等要素。  相似文献   

8.
餐饮业油烟排放具有排放浓度不稳定、波动较大、排放时间短等特性,存在瞬时排放高值现象,油烟"看得见"和"闻得着"的问题依然存在,因此对油烟实现快速、及时、直读监测尤为必要。基于一种浓度可控且稳定的油烟产生技术,对直读激光散射法与经典手工称重法测定油烟颗粒物浓度值的数据线性关系进行了分析,发现2种方法数值的相关系数达0.99,通过直读修正激光散射法可以有效地测定油烟颗粒物浓度,并测定了不同水汽含量下油烟颗粒物排放情况,发现当相对湿度超过70%时,油烟颗粒物浓度测定值会发生突变。使用便携式氢火焰离子化检测器法(FID)和光离子化检测器法(PID)测定了不同油温下油烟中非甲烷总烃(NMHC)浓度,发现FID对油烟中NMHC的变化反应及时,能够较好地测定油烟中挥发性有机物的排放量。  相似文献   

9.
乌鲁木齐市餐饮业油烟污染的调查及防治初探   总被引:1,自引:0,他引:1  
通过对乌鲁木齐市20家餐饮业油烟污染的调查分析,结果表明,乌鲁木齐市餐饮业油烟污染严重,并提出了防治措施。  相似文献   

10.
以3种常见食用油的蒸馏抽提冷凝物为标准品,用紫外分光光度法研究食用油烟气浓度的分析方法。结果表明油烟标准品和样品的最大吸收波长均为264nm;标准管油烟含量为0 ̄100μg围时,吸光度与油烟量间呈良好的线性关系(相关系数r为0.994 ̄0.999);该法测油烟含量的准确度即变异系数(CV%)为1.3% ̄8.5%(X=3.9%),回收率为90.83% ̄106.69%(99.4%),检测下限0.1μg  相似文献   

11.
In this study, we conducted polychlorinated biphenyls (PCBs) analysis using fast gas chromatography (GC)/high-resolution mass spectrometry (HRMS). Mass spectrometry (MS) was performed with a miniature multi-turn time-of-flight (TOF) analyzer called "MULTUM-S II". MULTUM-S II is truly a portable high resolution mass spectrometer. The mass spectrometer's high resolution capability is due to its theoretical infinite flight path utilizing perfect space and time focusing within a closed flight orbit. Mass resolution above 10?000 was easily achievable employing this portable system. This mass resolution is comparable to magnetic sector mass spectrometers, which have traditionally performed PCB analyses in the past. At a resolution of 10?000, a limit-of-detection of 1 ppb was determined using a heptachlorinated biphenyl standard sample. Using this fast GC/HRMS, 66 PCB congeners were analyzed within 5 min. In addition experiments aimed at confirming interference of PCB signal peaks and matrix peaks in diluted dielectric coolant fluids were performed. We found that the PCB signal peaks were detected without matrix interference via high mass resolution.  相似文献   

12.
Analysis of endosulfan, chlorpyrifos, and their nonpolar metabolites in extracts from environmental aqueous and soil samples was performed using a gas chromatography-tandem mass spectrometry (GC–MS/MS) technique. Full-scan GC–MS analysis showed poor sensitivity for some of the metabolites (endodiol and endosulfan ether). A multisegment MS/MS method was developed and MS/MS parameter isolation time, excitation time, excitation voltage, and maximum excitation energy were optimized for chosen precursor ions to enhance selectivity and sensitivity of the analysis. The use of MS/MS with optimized parameters quantified analytes with significantly higher accuracy, and detection limits were lowered to ~1/6th compared with the full-scan method. Co-eluting compounds, chlorpyrifos and chlorpyrifos oxon, were also analyzed successfully in the MS/MS mode by choosing exclusive precursor ions. Analysis of soil and water phase samples from contaminated soil slurry bioreactors showed that the MS/MS method could provide more reliable estimates of these pesticide and metabolites (especially those present in low concentrations) by annulling interferences from soil organic matter.  相似文献   

13.
Atmospheric fine and coarse particles were collected in Teflon filters in three cities of the region of the Lower Sinos River Basin of Rio Grande do Sul in the year 2010. The filters were Soxhlet extracted, and 14 priority PAHs were analyzed using a gas chromatograph coupled to a mass spectrometer (GC/MS). The principal emission sources of these compounds were assessed by using diagnostic ratios and receptor model: positive matrix factorization (PMF 3.0) of the US Environmental Protection Agency. The results of PAHs concentration for the studied year showed significant levels of high molecular weight (HMW) PAH, Ind, and BghiP, in PM2.5 in the winter season, showing the influence of mobile sources. The application of receptor model PMF 3.0 revealed that the main sources of PAHs were vehicle fleet (both diesel and gasoline), followed by coal combustion, wood combustion, and resuspension of dust. The results of the receptor modeling are in agreement with the data obtained by the ratio diagnostic.  相似文献   

14.
建立了地表水中痕量丙烯酰胺的柱前衍生-EI源串联四极杆气质联用测定方法。丙烯酰胺的双键经溴化衍生成2,3-二溴丙酰胺,加入硫酸钠盐析,乙酸乙酯萃取,浓缩取1μl进样,由串联四极杆气相色谱质谱联用仪测定。通过MRM(150→70.0/107.0)多反应监测实现定性和外标法定量分析。与其他方法相比,该方法具有定性准确、灵敏度高的特点。方法检出限为0.03μg/L,线性范围在0.030~40μg/L;相关系数r=0.9998;六次测定值RSD在14.3%;回收率在89%~196%之间,结果满意。  相似文献   

15.
非分散红外分光光度法测定饮食业油烟   总被引:1,自引:0,他引:1  
提出了非分散红外分光光度法测定饮食业油烟的方法.采用红外光谱仪,于2930cm^-1波数处进行测量。对滤简的空白值作了明确规定,只有其含油量在0.5mg/L以下才能用于测定。该方法操作简便,相对标准偏差为0.4%.精密度好。加标回收率在97%~105%之间。  相似文献   

16.
电线电缆行业漆包线生产工艺废气中有机物的GC/MS测定   总被引:1,自引:0,他引:1  
本文以活性炭、TenaxGC、聚氨酯泡沫为吸附材料,用二硫化碳洗脱、二氯甲烷提取、加热解吸三种脱附方式,并以色谱/质谱(GC/MS)联用仪为测试手段,对漆包线生产工艺废气中的有机物进行了测定,共检出72种有机化合物。本文进行了不同采集方式间的比较,提出了电线电缆行业工艺废气中有机化合物的系统分析方法。  相似文献   

17.
研究了采用含油污水中油类作为分析受其污染的地下水系统中油类的标准油可行性 ,紫外吸收光谱图和色质联机分析表明 ,污水、地下水、土壤中油类不仅主要成分相似 ,其相对含量也相同 ,证明了标准油选定的正确性。试验同时表明地下水系统中油类的污染正是目前仍在排放的含油污水引起的。  相似文献   

18.
使用PAMS和T0—15混合标准气体,采用钢罐采样-气相色谱/质谱法监测上海市某越江隧道空气中挥发性有机物,介绍了采样和测定方法,试验共检出78种化合物,查明了隧道空气中挥发性有机物的种类和组成。  相似文献   

19.
采用全二维气相色谱-飞行时间质谱法(GC×GC TOF-MS)分析了混标样品Aroclor 1260、Aroclor 1254、Aroclor 1242中的多氯联苯(PCBs)单体,考察了在复杂体系下对7种PCBs指示剂的分离能力。结果表明,与优化柱系统的分离效果相比,136种单体的混标样品中共分离出121种单体,7种指示剂经一维和二维的保留时间及质谱定性,在121种单体的2D斑点图中清晰可辨。全二维对于复杂体系的PCBs和指示剂的分离表明其强大的分离能力和对于检测复杂体系中指示剂的分辨能力,对该类物质的定性和定量检测具有重要意义。  相似文献   

20.
Elemental analysis and isotopic composition evaluated the impact of human activity at the surface sediments in the largest island of Todos os Santos Bay, northeastern Brazil. Saturated hydrocarbons (n-alkanes and isoprenoids) by gas chromatography coupled with a flame ionization detector and 13C by mass spectrometer were determined from 30 surface sediment samples in mangroves at the Itaparica Island (Bahia-Brazil) in the rainy and dry season. These data, distribution, and ratio of carbon/nitrogen showed a mixture of sources: continental, marine, and anthropogenic ones. From the chromatographic profiles, light oil contamination was observed in the dry regions of Baiacu, Campinas, and Ponta Grossa, while in Jiribatuba it was observed during the rainy season. However, δ13C results during dry and rainy season in the presence of oil also showed in Misericordia and Cacha Prego districts for both periods and Ponta Grossa during the rainy season. Principal component analysis, using a correlation matrix, revealed the latent relationships among all the surface sediment stations investigated and confirmed our analytical results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号