首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
提出了沸水浴混合酸法消解,以异丙醇为增感剂,电感耦合等离子体质谱直接测定土壤和沉积物中硒的方法。实验表明2mol/L硝酸-4mol/L盐酸混酸能有效溶出土壤和沉积物中各种形态的硒。相对于1%硝酸基体,4%(V/V)异丙醇基体中硒的ICP-MS响应值提高了12.1倍;而且4%(V/V)异丙醇基体可有效抑制硒的质谱干扰。ICP发射功率和雾化气流速是影响异丙醇在ICP-MS测定过程增敏效应的主要因素。以78硒为测定同位素,方法检出限为0.005mg/kg,实际样品测定精密度均小于5%。用于测定土壤和沉积物国家标准样品并对其消解液进行加标回收实验,结果令人满意。  相似文献   

2.
采用自动净化-高分辨气相色谱/高分辨质谱(HRGC/HRMS)测定废气中的17种2,3,7,8位取代的多氯代二噁英和呋喃(PCDD/Fs)。废气样品经索氏提取,DEXTech系统全自动净化,浓缩和定容后,以HRGC/HRMS对废气样品中的PCDD/Fs进行了定性和定量分析。结果表明,17种二噁英和呋喃采样内标平均回收率为93%~99%,提取内标平均回收率为80%~97%;17种二噁英和呋喃自动净化实测结果与手工净化测试结果基本一致。该方法不但满足相关国家标准要求,还极大提高了样品的净化速度,减少人体对有机试剂的暴露。  相似文献   

3.
便携式GC-MS在应急监测中的应用   总被引:2,自引:1,他引:1  
建立了便携式GC-MS测定空气和水体中挥发性有机物(VOCs)的方法,能快速、有效地对空气中37种和水体中54种挥发性有机物进行现场定性和定量。具有相关性好、检出限低、精密度好、准确度高的特点,适用于空气和水体中挥发性有机物的应急监测工作。  相似文献   

4.
The distribution and concentrations of polychlorinated biphenyls (PCBs) were determined in fish species (European perch Perca fluviatilis, northern pike Esox lucius, pike perch Sander lucioperca, wels catfish Silirus glanus, common carp Cyprinus carpio, European eel Anguilla anguilla, freshwater bream Abramis brama, goldfish Carassius auratus, and roach Rutilus rutilus) in a heavily polluted water reservoir Zemplínska ?írava (Slovakia). The study performed at two different time points 5?years apart (2004 and 2009) revealed serious PCB contamination of fish muscle tissue and significant interspecies as well as tissue-specific differences in PCB uptake by fish. Total PCBs broadly correlated with the trophic position of individual fish species within a food chain (P??0.05). The study has shown that the kind of fish, its feeding habit, and specific conditions of the habitat are mutually interrelated factors that are responsible for significant variations in fish body burdens. A tendency to PCB biomagnification was also proved in some fish species of this water reservoir.  相似文献   

5.
The objective of this study was to determine the size and composition of atmospheric aerosols in the downtown area of the city of S?o Paulo, Brazil, for a polluted and an unpolluted period. Aerosols were sampled with a portable air sampler (PAS), Micro-Orifice Uniform Deposit Impactor (MOUDI), and Scanning Mobility Particle Sizer. At the study site, air quality is poor, especially during the winter, high concentrations of pollutants being emitted primarily by the light- and heavy-duty vehicle fleet. We analyzed mass, black carbon (BC), Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sn, Zr, and Pb. During the polluted period, diurnal PM10 was higher than nocturnal PM10, whereas the inverse was true during the unpolluted period. The FPM was rich in BC, S, and Pb, whereas CPM was rich in Al, Si, Ca, Ti, and Fe. Mass balance was performed by category: ammonium sulfate, sodium chloride, crustal material, BC, and other. The PAS-determined FPM was mainly BC. The MOUDI-determined FPM crustal material explained more mass than did ammonium sulfate and BC during the polluted period, whereas ammonium sulfate had the largest mass during the unpolluted period. Crustal material was the major CPM component, followed by ammonium sulfate and BC. During the unpolluted period, FPM concentrations were lower, whereas those of ammonium sulfate were relatively higher, especially at night, and particle number was inversely proportional to particle size. Aerosol growth was more intense during the polluted period.  相似文献   

6.
A comprehensive clean-up method for quantitative analysis of polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples was developed. Since the chemical nature and toxicity of planar PCBs are similar to those of PCDD/Fs, dioxin-like PCBs and PCDD/Fs are often surveyed together in their exposure assessments. The development of a method for the simultaneous analysis of PCBs and PCDD/Fs in environmental samples is invaluable. The automated clean-up system evaluated in this work consists of three additional steps after traditional extraction: the chromatography on gel permeation (GPC), the concentration of the solvent through the use of an in-line evaporation module and the further purification and separation of PCDDs/Fs and dl-PCBs on an alumina cartridge in the 'SPE module'. In this work, three fly ash samples from an interlaboratory study with different PCDD/F and PCB levels were Soxhlet-extracted and then cleaned up using an automated system. PCDD/Fs and PCBs were determined using isotope dilution and high resolution gas chromatography/high resolution mass spectrometry. The determined values of 17 PCDD/Fs were consistent with the certified values and the relative standard deviations (RSDs) of the determined values were less than 20%. The recoveries of (13)C labeled PCDD/Fs and planar PCBs, and their RSDs were within the ranges specified in EPA1613 and 1668a methods, respectively. An accurate and reliable method was successfully developed and can be used in the simultaneous analysis of PCDD/Fs and planar PCBs in environmental samples.  相似文献   

7.
Gas chromatography-mass spectrometry (GC-MS) has played a pivotal role in the discovery of disinfection by-products (DBPs) in drinking water. DBPs are formed when disinfectants, such as chlorine, ozone, chlorine dioxide or chloramine, react with natural organic matter in the water. The first DBP known--chloroform--was identified by Rook in 1974 using GC-MS. Soon thereafter, chloroform and other trihalomethanes were found to be ubiquitous in chlorinated drinking water. In 1976, the National Cancer Institute published results linking chloroform to cancer in laboratory animals, and an important public health issue was born. Mass spectrometry and, specifically, GC-MS became the key tool used for measuring these DBPs in water and for discovering other DBPs that were formed. Over the last 25 years, hundreds of DBPs have been identified, mostly through the use of GC-MS, which has spawned additional health effects studies and regulations. Early on, GC with low resolution electron ionization (EI)-MS was used, together with confirmation with chemical standards, for identification work. Later, researchers utilized chemical ionization (CI)-MS to provide molecular weight information and high resolution El-MS to aid in the determination of empirical formulae for the molecular ions and fragments. More recently, liquid chromatography-mass spectrometry (LC-MS) with either electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) has been used to try to uncover highly polar DBPs that most experts believe have been missed by earlier GC-MS studies. Despite 25 years of research in the identification of new DBPs, new ones are being discovered every year, even for chlorine which has been the most extensively studied.  相似文献   

8.
简述了液相色谱串联高分辨质谱(LC-HRMS)的优势和其在水环境监测领域中的实际工作流程。分析了LCHRMS在水环境监测应用中面临的数据库储备相对匮乏和优先锁定定性目标相对滞后的问题,提出,通过建立目标化合物数据库,从厂家或供应商处购买与仪器匹配的数据库,建立高通量靶向监测和高通量非靶向筛查的体制机制,以及建立具有地方特色的特征污染物数据库等几种方式,以期进一步提高鉴别工作效率,更好地满足水环境监测的筛查需求。  相似文献   

9.
Near real-time measurements of light non-methane hydrocarbons (NMHCs) and peroxyacetyl nitrate (PAN) have been performed in the free troposphere using two fast gas chromatography (GC) instruments designed for use on aircraft. A GC-helium ionisation detector (HID) system measured 15 C(2)-C(5) hydrocarbons with 5 min time resolution and a dual channel GC-Electron Capture Detector (ECD) measured PAN with 90 s resolution. Both instruments had low parts per trillion by volume (pptV) detection limits and ran continuously at the remote Jungfraujoch (JFJ) research station in the Swiss Alps (46.55[degree]N, 7.98[degree]E), 3580 m above mean sea level (AMSL), during February/March 2003. Carbon monoxide, ozone, nitrogen oxide and nitrogen dioxide and all odd nitrogen species (NO(y)) were also measured continuously. Hydrocarbons and CO were strongly correlated in all air-masses whilst PAN exhibited both positive and negative correlations with respect to O(3), dependent on age and origin of the air-mass sampled. PAN was found to contribute [similar]20% to the NO(y) sampled on average. The experiment, as well as providing interesting datasets from this remote location, also demonstrated that when optimised, GC techniques have the potential to measure at a time resolution significantly greater than is traditionally considered, with high sensitivity and low uncertainty.  相似文献   

10.
A laboratory experiment was performed to examine the remobilization of indicator polychlorinated biphenyls (iPCBs) from sediments and its results were applied to the real-world data for explaining the transport of PCBs in river. Seven PCB concentrations were determined in three series of model water–sediment systems (3 g of river sediment, three different volumes of distilled water (0.5, 0.25, and 0.15 ml), and 5 mg of biocide) after 11 days of incubation. Solid-phase extraction was used for separation of analytes from the aqueous phase and solvent extraction for isolation of analytes from the sediments, respectively. The extracts were analyzed for individual iPCB congeners using gas chromatography–mass spectrometry method. For each series of the experiment, the concentrations of PCBs in aqueous phase were similar. The average sediment/water partition coefficient value was 104?l/kg. The solubility of individual PCB congeners in water did not influence the desorption of PCBs from the sediment. Although the dominant form of PCBs in a water–sediment system occurs as suspended and colloidal fractions, these compounds are transported mostly in a dissolved form. Suspended and colloidal matter is a major sink for PCBs in low-energy aquatic environments. In contrast, the dissolved PCBs are readily transported in running waters. The mobilization of PCBs from sediments to aqueous phase, with respect to their solubility in water, seems to be limited, thus reducing the risk of secondary pollution.  相似文献   

11.
A simple and fast solid phase extraction procedure was developed to pre-concentrate traces of Cu and Zn prior to their determination in honey samples by flame atomic absorption spectrometry. The sample preparation included dissolution of honey samples and the passage (at 20 ml/min) of resulting 10 % m/v solutions (100 ml) through Dowex 50W?×?8-400 resin beds in order to quantitatively retain Cu and Zn and separate them from the glucose and fructose matrix. Enriched Cu and Zn traces were recovered with 5.0 ml of a 3.0 mol/l HCl solution and quantified by flame atomic absorption spectrometry. The procedure proposed was used to analyze sixty nine commercially available and freshly ripened honey samples coming from the Lower Silesia region (Poland). It enabled to measure Cu and Zn within the range of 0.01–1.42 and 0.03–15.38 μg/g, respectively, with precision better than 4 %. Accuracy, assessed on the basis of the recovery test and the comparison of results with those obtained using wet digestion and inductively coupled plasma optical emission spectrometry, was ranged from ?4 % to +6 %. Detection limits of Cu and Zn achieved with this method were 5 and 7 ng/g, respectively.  相似文献   

12.
The application of different injectors in capillary gas chromatography (GC) analysis of semi-volatile organic contaminants in environmental samples prepared in organic solvents is reviewed. The injectors examined include a split/splitless injector in splitless mode (SS), cold on-column (COC), and programmable temperature vaporizer (PTV) and adaptations of these injector designs. Key issues when selecting an injector include properties of the analyte, such as potential for thermal degradation or discrimination of high boiling point compounds within the injector, and the ability of the GC systems to handle large volume injections (LVI) primarily to lower detection limits and allow direct coupling with sample preparation techniques such as at-line or on-line solid phase extraction (SPE). LVI also require consideration of matrix interference issues. This review examines only injector chamber modifications that are feasible with a standard GC configuration, however some modifications to the chromatographic system to extend the range of applicability of gas chromatography analysis for environmental samples are also noted.  相似文献   

13.
Benzotriazole UV stabilizers (BUVSs), such as UV-328 and UV-327, were identified in the blubbers of finless porpoises (Neophocaena phocaenoides) collected from the Ariake Sea, western Japan, by gas chromatography-high resolution mass spectrometry (GC-HRMS). The mean concentrations and standard deviations of UV-328 and UV-327 in five blubber samples were 38 ± 28 ng g(-1) (lipid wt) and 19 ± 19 ng g(-1), respectively. The bioconcentration factor (BCF) of UV-327 between water and finless porpoises was estimated to be 33?300, which is approximately one order of magnitude higher than that found for small fish inhabiting the same regions. The BCF of UV-327 in finless porpoises was similar to that of persistent organochlorine pesticide, hexachlorocyclohexane (HCH: 37?000) in marine mammals from the western North Pacific Ocean. These results suggest that BUVSs appear to be persistent and bioaccumulative in the aquatic food chain. Further investigations on temporal trends, and regional and global monitoring of BUVSs are needed to understand their environmental profiles and potential risks to wildlife and human.  相似文献   

14.
The main goal of this study was to evaluate the impacts of a middle-sized Finnish urban area on the quality of sediments in an adjacent boreal lake. We investigated the sources and distribution of organic pollutants (polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs)) in the sediments from urban stormwater traps and from Lake Vesijärvi. Grab surface sediment samples were taken from Lake Vesijärvi at various distances (25–2,000 m) from four major stormwater drainage outlets and at 15 urban stormwater traps in areas with different degrees of urbanization. These samples were analysed for 16 PAHs and 28 PCBs with gas chromatography–mass spectrometry. The concentrations of pollutants in the lake sediments were elevated in the vicinity of the urban shore (∑PAH 3–16, ∑PCB up to 0.02–0.3 mg/kg dw) and decreased as a function of distance (∑PAH 0.1–2.5, ∑PCB 0.01–0.3 mg/kg dw at a distance of more than 500 m from the shore), whereas contamination levels in suburban areas were notably lower (∑PAH 0.1–3, ∑PCB?<?LOQ–0.03 mg/kg dw; did not decline with distance). Possible sources and pathways of contamination were also investigated. The majority of stormwater trap sediments contained predominantly asphalt-derived PAHs due to pulverized pavement. PAHs in lake sediments were of pyrogenic origin, including the combustion of gasoline, diesel and coal. Suggested pathways of lake contamination are urban runoff discharge, boat traffic and atmospheric deposition.  相似文献   

15.
建立了在线固相萃取-超高效液相色谱-三重四极杆质谱联用技术测定地表水中痕量磺胺类抗生素的方法。样品经滤膜过滤,HLB在线固相萃取小柱富集纯化,以Acquity BEH 130为分析柱,三重四极杆质谱进行检测,外标法定量。通过在线固相萃取,并对色谱和质谱等条件进行优化,该方法检出限为0.2~1.1 ng/L,回收率为80.6%~113%,相对标准偏差<10.6%,浓度范围内线性良好(r>0.9972),满足了磺胺类抗生素痕量分析测试的要求,且分析时间仅需17min。该方法灵敏度高、分析速度快,对于保障水环境安全,及时提供污染信息,有效应对环境应急突发事件具有十分重要的意义。  相似文献   

16.
Mass Concentration of ambient particulate matter with an aerodynamic diameter less than 10µm (PM10) are reported for the first time for a range of sites in Dublin City over a 6 month period from January 1st 1996 to June 30th 1996. PM10 gravimetric mass concentration measurements are made with low flow Partisol 2000 air samplers using an impaction type PM10 inlet and 47mm diameter glass fibre filters. In addition, much finer time resolution measurements (minimum sampling frequency of 30 minutes) are made using a tapered element oscillating microbalance (TEOM) PM10 mass monitor. These PM10 mass concentrations methods are also compared with mass concentration inferred using the standard black smoke method. Analysis of the ambient mass concentration data with reference to traffic density and meteorological influences are presented. Results for the first six months of 1996 show that the average PM10 values range from a high of 49 µg m-3 at the Dublin city centre site to 14 µg m-3 at one of the suburban sites. Intercomparison between PM10 and black smoke mass concentrations show that the relationship is site specific. Statistical analysis between PM10 levels and car traffic number show a positive correlation while a weak negative correlation is found between PM10 levels and rainfall amount, wind speed and air temperature.  相似文献   

17.
A trace analytical method is presented for the analysis of hydroxylated polychlorinated biphenyl metabolites (HO-PCBs) and pentachlorophenol (PCP) in human plasma. The described methodology is a modification of a previously validated method used for PCB and organochlorine pesticide analysis. The modified method enables the combined analysis of phenolic and neutral halogenated compounds. A tandem Florisil column is used for separating the HO-PCBs and PCP from the neutral fraction, instead of the more common chemical partitioning. In the same step the neutral fraction is purified for GC analysis. The extraction of the HO-PCBs and PCP was found to be highly dependent on sufficient acidification of the sample and the polarity of the extracting solvent. Analysis of plasma samples gave recovery rates for (13)C(6)-PCP and (13)C(12)-4-HO-CB 187 of 64 and 72%, respectively. The limit of detection ranged between 2-20 pg g(-1) plasma for the HO-PCBs and 5 pg g(-1) plasma for PCP. No matrix interferences were observed in the chromatograms. In plasma samples (n = 15) from the native Chukchi people in Uelen (Russian Arctic), a population with high PCB exposure, the median ratio of sum HO-PCBs to sum PCBs was as high as 0.4 and the sum HO-PCBs and PCBs were significantly correlated (r(2) > 0.7, p < 0.01). The median sum HO-PCBs (10 congeners) was 5920 pg g(-1) plasma with 4-HO-CB 107 as the dominating congener (median: 1670 pg g(-1) plasma). The median PCP level was measured at 642 pg g(-1) plasma.  相似文献   

18.
Dechlorination of a nonachloro biphenyl congener with zero-valent iron in water under high temperature and pressure was investigated over time. Temperature has the main influence on the speed of dechlorination. Determination of polychlorinated biphenyls (PCBs) according to the grade of chlorination was performed by gas chromatography with mass selective detection in single ion monitoring mode. Dechlorination results in a variety of lower chlorinated biphenyls. The level of chlorination decreases with time. The amount of PCB molecules decreases to one-third within 90 min at 250 degrees C and 100 atm. However, no increase of biphenyl could be detected over time. A first-order kinetic model fitted the data obtained.  相似文献   

19.
Comprehensive two dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-TOF-MS) was used for screening and semiquantitation of semivolatile organic compounds in aerosol particles. As the volatility was a prerequisite parameter for the analysis, some compounds were transformed via derivatization such as silylation into more volatile ones. The identification of the analytes was made by comparing the GC retention indices and the TOF mass spectra with the NIST and the Golm metabolome database reference libraries. The data treatment was simplified by exploiting an additional classification of the identified compounds, namely the main functional group or specific element present in the molecule leading to different groups of compounds. This methodology was applied to identify compounds in 30 ± 4 nm, 50 ± 5 nm and total suspended particles (TSP) collected during spring and autumn of 2009 and summer of 2010 at the Station for Measuring Forest Ecosystem Atmosphere Relations (SMEAR II) at Hyyti?l? (Finland). The number of identified compounds was higher than 400, which were the most relevant compounds present in the samples, in terms of concentrations. The analysis of aerosol particles of different sizes, collected simultaneously, revealed that the number of compounds increased with the particle size whereas the normalized response factor decreased in most of the cases, aldehydes being an exception. This decrease could be associated with the formation or aggregation of new compounds onto the particles when they grow in the atmosphere.  相似文献   

20.
Previously it was demonstrated that the levels of large particles (>2 micron) and associated bacterial cell envelope markers increase greatly on occupation in schools; it was hypothesized that the source of both was shed human skin. In the current work to test this hypothesis, room air cleaners were used to collect airborne dust (>50-100 mg) from occupied and unoccupied school rooms which was then subjected to proteomic analysis. Proteins were extracted from the dust and separated using two dimensional gel electrophoresis (2D GE). In situ digestion of protein spots with trypsin released peptides, which were subsequently analyzed by matrix assisted laser desorption/deionization, time-of-flight mass spectrometry (MALDI-TOF-MS) and tandem mass spectrometry (MALDI-TOF-MS-MS). In Coomassie blue stained gels, a single spot generally dominated the 2D gels; this protein was identified by tandem mass spectrometry as K10 epithelial keratin. The results experimentally confirm previous anecdotal reports that human skin is readily shed into air and suggest that increased levels of microbial markers and large particles observed in occupied rooms are also derived from skin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号