首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
本文建立了用便携式气相色谱-质谱仪快速测定土壤中VOCs的方法。该方法能够快速对土壤样品中VOCs进行定性分析和定量测定。当采样量达到5 g时,方法检出限0.02~2.11μg/L,相对标准偏差2.0%~13.5%;加标20μg/L时,回收率63%~123%。采用该方法测定北京地区5个土壤样品,总体质量浓度为0~873μg/kg。  相似文献   

2.
建立QuEChERS-气相色谱法同时检测土壤中8种有机氯农药的方法,优化分散固相萃取剂用量。土壤样品通过分散固相萃取净化技术,氮吹浓缩后用正己烷定容,最后通过气相色谱测定。结果表明,在2.0~100μg/L质量浓度范围内呈线性,相关系数r为0.9895~0.9991。空白样品在0.5,5和20μg/kg加标浓度下的回收率为75.3%~92.3%,相对标准偏差为3.2%~5.6%(n=5),方法检出限为0.053~0.064μg/kg,测定下限为0.21~0.26μg/kg。该方法操作简单、结果准确、有机试剂用量少、分析成本低,适用于土壤中有机氯农药的残留检测与分析。  相似文献   

3.
采用顶空气相色谱质谱法(HS/GC-MS)对土壤中挥发性卤代烃进行了测定,优化了分析的顶空条件、气相色谱质谱分离条件。在优化条件下成功实现了24种挥发性卤代烃的分离,确定了分析方法的检出限、测定下限、精密度及回收率等质量控制参数。方法的检出限为0.8~4.4μg/kg,测定下限为3.2~17.6μg/kg。当加标量为100μg/kg和250μg/kg时,相对标准偏差分别为1.3%~12.6%和2.6%~8.7%,加标回收率分别为71.4%~126%和63.1%~121%。  相似文献   

4.
建立了用微波萃取(MAE)、固相萃取(SPE)净化、气相色谱,串联四极杆质谱(GC-QqQ-MS/MS)多反应监测同时测定土壤中16种多环芳烃和18种邻苯二甲酸酯的方法.通过优化前处理与分析条件,样品加标浓度在5μg/kg时的平均回收率在66.59%~122.07%之间,相对标准偏差均小于20%,邻苯二甲酸酯的检出限在0.04.0.84.ttg/kg之间.定量限在0.13~2.81μg/kg之间;多环芳烃的检出限在0.01~0.54μg/ks之间,定量限在0.02~1.81μS/kg之间,能够满足大量样品快速准确分析的需要.  相似文献   

5.
水中的乙醛、丙烯醛、丙烯腈和吡啶经吹扫捕集、解吸后,用HP-VOC毛细管色谱柱进行GC分离,用GC-MS法选择离子模式(SIM)下进行检测,外标法定量。结果表明,选择取样量25 m L,吹扫流量为40 m L/min,吹扫温度为40℃,吹扫时间为15 min,解吸时间为2 min,解吸温度为200℃,烘焙时间20 min,乙醛和吡啶质量浓度在0.025~0.60 mg/L之间,丙烯醛和丙烯腈质量浓度在0.002 5~0.10 mg/L之间时,校准曲线呈线性关系,相关系数r0.995,乙醛、丙烯醛、丙烯腈和吡啶的方法检出限分别为0.001 6,0.001 3,0.000 5和0.002 1 mg/L。对3个不同浓度样品进行空白加标实验,测量的回收率为87.8%~114.3%,相对标准偏差(n=6)为2.51%~10.4%。对3批实际水样进行分析,其中一个废水水样加标回收率为79.2%~103.8%,相对标准偏差(n=6)为3.04%~6.39%。  相似文献   

6.
建立了液液萃取-气相色谱法测定水中15种硝基氯苯类化合物的方法。中性条件下,在水样中加入氯化钠,用环己烷进行萃取,得到方法检出限为0.019~0.044μg/L,在10.0μg/L~1.0 mg/L范围内线性良好,相关系数均0.999。加标水平为2.5μg/L时,空白水样加标回收率为74.8%~104%,相对标准偏差为4.79%~11.5%;实际水样加标回收率为69.1%~111%,相对标准偏差为5.83%~17.6%。方法适用于成分不复杂的实际水样中硝基氯苯类化合物的检测。  相似文献   

7.
建立了分散液液微萃取与超高效液相色谱-串联质谱联用技术测定土壤和沉积物中三丁基锡的方法。考察了影响分散液液微萃取的因素(包括有机萃取溶剂、萃取剂体积、分散剂、分散剂体积、萃取时间和盐效应)。在最佳实验条件下,方法在0.5~50μg/kg范围内线性关系良好,相关性系数为0.999 0,方法检出限(3倍信噪比)为0.1μg/kg,加标回收率为83.1%~104%,相对标准偏差小于8.5%(n=6),适用于土壤和沉积物中三丁基锡的检测。  相似文献   

8.
建立了用加速溶剂萃取仪(ASE)萃取、凝胶渗透色谱(GPC)净化、气相色谱/串联四极杆质谱多反应监测、同时测定土壤中17种有机氯农药和19种多氯联苯的方法.加标浓度在3.3μg/kg时的平均回收率在79.6%~93.2%之间,相对标准偏差在2.9%~13.0%之间,定量限在0.01~0.51μg/kg之间.在检测土壤样品中的有机氯农药和多氯联苯残留方面,Gc-QqQ-MS/MS相对于气相色谱/电子捕获检测器(GC-ECD)和GC-MS的选择离子检测(SIM)模式具有非常明显的优势,尤其是在低浓度水平的定性和定量方面.  相似文献   

9.
采用水平震荡和超声浸取2种方法进行预处理,离子选择电极法测定土壤中水溶性氟化物。结果显示:土壤中水溶性氟化物的最佳预处理条件为纯水与土壤按10∶1混合,常温35 k Hz超声浸取30 min。超声浸取-离子选择电极法测定土壤中水溶性氟化物具有较好的精密度和准确性,此法在5.00~500μg范围内线性良好,检出限为0.5 mg/kg。对实际样品进行分析,氟的加标回收率为82.0%~110%,相对标准偏差为2.8%~6.4%(n=6)。对土壤有证标准物质进行分析,相对标准偏差为2.9%~4.6%(n=6),相对误差为-3.9%~2.7%。  相似文献   

10.
采用固相萃取-气相色谱/质谱法测定水中15种酞酸酯类化合物,确定方法的最优条件为:依次用10 m L正己烷和丙酮混合溶剂(V/V=5∶1)、甲醇和空白试剂水活化C18固相萃取柱后,水样以5 m L/min过柱萃取,再以8 m L正己烷:丙酮(V/V=5∶1)混合溶剂洗脱后,浓缩至1 m L,进气相色谱/质谱测定。该法的检出限为0.18~0.38μg/L,在0.50~20.0 mg/L范围内线性良好,相关系数均0.996。空白水样的加标回收率为71.8%~120%,相对标准偏差为1.73%~12.7%;实际废水水样的加标回收率为64.8%~135%,相对标准偏差为2.75%~18.0%。  相似文献   

11.
A molecularly imprinted polymer (MIP) was prepared using chlorsulfuron (CS), a herbicide as a template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate (EDMA) as a cross-linker, methanol and toluene as a porogen, and 2,2-azobisisobutyronitrile as an initiator. The binding behaviors of the template chlorsulfuron and its analog on MIP were evaluated by equilibrium adsorption experiments, which showed that the MIP particles had specific affinity for the template CS. Solid-phase extraction (SPE) with the chlorsulfuron molecularly imprinted polymer as an adsorbent was investigated. The optimum loading, washing, and eluting conditions for chlorsulfuron molecularly imprinted polymer solid-phase extraction (CS-MISPE) were established. The optimized CS-MISPE procedure was developed to enrich and clean up the chlorsulfuron residue in water, soils, and wheat plants. Concentrations of chlorsulfuron in the samples were analyzed by HPLC-UVD. The average recoveries of CS spiked standard at 0.05~0.2 mg L(-1) in water were 90.2~93.3%, with the relative standard deviation (RSD) being 2.0~3.9% (n=3). The average recoveries of 1.0 mL CS spiked standard at 0.1~0.5 mg L(-1) in 10 g soil were 91.1~94.7%, with the RSD being 3.1~5.6% (n=3). The average recoveries of 1.0 mL CS spiked standard at 0.1~0.5 mg L(-1) in 5 g wheat plant were 82.3~94.3%, with the RSD being 2.9~6.8% (n=3). Overall, our study provides a sensitive and cost-effective method for accurate determination of CS residues in water, soils, and plants.  相似文献   

12.
石墨炉原子吸收光谱法测定水中四乙基铅   总被引:6,自引:0,他引:6       下载免费PDF全文
采用三氯甲烷萃取-石墨炉原子吸收光谱法测定水中四乙基铅,优化了试验条件。方法在2.00μg/L~50.0μg/L范围内线性良好,检出限为1.3×10^-5mg/L,标准溶液测定的RSD≤8.6%,实际水样加标回收率为90.4%~108%。  相似文献   

13.
通过对加速溶剂萃取、平行蒸发及净化方法等环节的优化实验,建立了加速溶剂萃取-凝胶净化色谱-气相色谱质谱法测定农用地土壤中23种有机氯农药的检测方法。结果表明,方法检出限为0.0034~0.0052 mg/kg;对化合物质量分数为0.25 mg/kg的土壤加标样品进行平行实验,回收率为82.0%~93.7%;测定结果的相对标准偏差(RSD)≤8.7%。对土壤有证标准质控样品进行分析,测定结果均在验收范围之内。该方法准确可靠,灵敏度较高,样品净化效果较好,能够满足农用地土壤中有机氯农药残留痕量分析的要求。  相似文献   

14.
固相萃取-高效液相色谱法测定饮用水中酚类化合物   总被引:2,自引:0,他引:2  
采用固相萃取-高效液相色谱法测定饮用水中酚类化合物,优化了试验条件。方法在0 mg/L~40.0 mg/L范围内线性良好,14种酚类化合物的检出限为0.6μg/L~2.6μg/L,水样平行测定的RSD为0.2%~2.7%,加标回收率为96.3%~99.9%。  相似文献   

15.
建立了一种液-液小体积萃取GC-MS快速测定地表水中氯苯类化合物的分析方法。该方法具有操作简单快速、适用性广和试剂用量很少等特点。当萃取试剂用量为2ml时(约为一般常规液-液萃取用量的数十分之一),萃取富集效率可达300~500倍,回收率为93%~98%,相对标准偏差为4%~8%,检出限为0.1~0.3μg/L。  相似文献   

16.
以正己烷/丙酮混合溶剂(体积比为1∶1)为提取剂,采用Florisil柱净化、气相色谱电子捕获检测器测定土壤中菊酯类农药残留,优化了提取条件。4种菊酯类农药在0.010 mg/L~1.00 mg/L范围内线性良好,方法检出限为0.005 mg/L~0.010 mg/L,甲氰菊酯回收率为85.2%~103%,RSD为2.3%~5.4%;氯氰菊酯回收率为80.5%~103%,RSD为2.8%~6.7%;氰戊菊酯回收率为80.2%~103%,RSD为2.3%~6.0%;溴氰菊酯回收率为80.8%~103%,RSD为2.4%~6.2%。  相似文献   

17.
制备类沸石咪唑酯骨架ZIF-L材料,将其用作微固相萃取吸附剂,处理水中萘、苊、苊烯、芴、菲、蒽、荧蒽、芘等8种痕量典型多环芳烃,再用HPLC测定。试验表明,ZIF-L对上述多环芳烃的萃取效率明显高于商品化萃取材料C 18和多壁碳纳米管。方法在0.100μg/L^200μg/L范围内线性良好,方法检出限为0.02μg/L^0.03μg/L,标准溶液5次测定结果的RSD为4.7%~9.5%,实际水样加标回收率为84.5%~115%。将该方法用于北太湖5个点位水样的测定,测定值为未检出~3.40μg/L。  相似文献   

18.
采用C 18柱固相萃取(SPE)-三重四级杆气相色谱-质谱法同时测定水中18种含有机氯的环境内分泌干扰物,方法在0.500μg/L^100μg/L范围内线性良好,方法检出限为0.04 ng/L^0.8 ng/L,空白水样的加标回收率为61.3%~108%,6次测定结果的RSD为3.8%~18.0%。将该方法用于饮用水源水监测,18种目标化合物的测定值为未检出~1.5 ng/L,平均加标回收率为71.9%~109%,平行测定结果的RSD<15%。  相似文献   

19.
采用固相萃取-高效液相色谱(SPE - HPLC)二极管阵列检测器同时测定水中呋喃丹、甲萘威和阿特拉津,以甲醇-水为流动相,采用梯度洗脱方式,选择220 nm为检测波长,二氯甲烷为洗脱剂.呋喃丹在0.200 mg/L ~5.00 mg/L、甲萘威和阿特拉津在0.020 mg/L~5.00 mg/L范围内线性良好,检出限...  相似文献   

20.
使用Oasis HLB固相萃取柱,以正己烷/丙酮混合溶剂(体积比为3∶1)为洗脱溶剂,采用毛细管柱气相色谱电子捕获检测器同时测定水中15种硝基苯类化合物,以保留时间定性,外标标准曲线法定量。硝基苯和硝基甲苯在50.0μg/L~1 000μg/L、其他硝基苯类化合物在5.00μg/L~100μg/L范围内线性良好,检出限硝基苯和硝基甲苯为0.035μg/L~0.052μg/L,其他硝基苯类化合物为0.003 5μg/L~0.005 6μg/L,加标水样平行测定的RSD为1.4%~4.0%,平均回收率为92%~100%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏