首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Selection of appropriate sampling stations in a lake through mapping   总被引:1,自引:0,他引:1  
Much valuable information is obtained from water quality measurements and monitoring of lakes around the world. A powerful tool is the use of mapping techniques, as it offers potential use in water quality research. Both remote sensing techniques and traditional water quality monitoring are required to collect data at sampling stations. This study suggests another approach to determine the most appropriate distribution of sampling stations in water reservoirs that will be mapped for water quality parameters. Tests were conducted for the proposed approach for Secchi disc depth (SDD), chlorophyll-a, turbidity and suspended solids parameters in Lake Beysehir, Turkey. Results of analysis are available for a total of 30 sampling stations in August 2006. Ten sampling stations were used to model Lake Beysehir while the others were used for validation of the model. Sampling stations that offered the best representation of the lake for each parameter were determined. Then, the best representative sampling stations for all parameters in the study were determined. Moreover, in order to confirm the accuracy of these re-determined sampling stations, modelling was performed on the results of the analysis of June 2006, and it was found that the values obtained from the re-determined sampling stations were acceptable.  相似文献   

2.
This paper describes the effects of drilling disturbance on the seafloor of the upper continental slope of the Campos Basin, Brazil, as a result of the project Environmental Monitoring of Offshore Drilling for Petroleum Exploration – MAPEM. Field sampling was carried out surrounding wells, operated by the company PETROBRAS, to compare sediment properties of the seafloor, including grain-size distribution, total organic carbon, and clay mineral composition, prior to drilling with samples obtained 3 and 22 months after drilling. The sampling grid used had 74 stations, 68 of which were located along 7 radials from the well up to a distance of 500 m. The other 6 stations were used as reference, and were located 2,500 m from the well. The results show no significant sedimentological variation in the area affected by drilling activity. The observed sedimentological changes include a fining of grain size, increase in total organic carbon, an increase in gibbsite, illite, and smectite, and a decrease in kaolinite after drilling took place.  相似文献   

3.
Effluent from sewage treatment plants has been associated with a range of pollutant effects. Depending on the influent composition and treatment processes the effluent may contain a myriad of different chemicals which makes monitoring very complex. In this study we aimed to monitor relatively polar organic pollutant mixtures using a combination of passive sampling techniques and a set of biochemistry based assays covering acute bacterial toxicity (Microtox), phytotoxicity (Max-I-PAM assay) and genotoxicity (umuC assay). The study showed that all of the assays were able to detect effects in the samples and allowed a comparison of the two plants as well as a comparison between the two sampling periods. Distinct improvements in water quality were observed in one of the plants as result of an upgrade to a UV disinfection system, which improved from 24x sample enrichment required to induce a 50% response in the Microtox assay to 84x, from 30x sample enrichment to induce a 50% reduction in photosynthetic yield to 125x, and the genotoxicity observed in the first sampling period was eliminated. Thus we propose that biochemical assay techniques in combination with time integrated passive sampling can substantially contribute to the monitoring of polar organic toxicants in STP effluents.  相似文献   

4.
The aim of this research is to determine the effects of Izmir Big Channel Waste Water Treatment Project on the sediment quality of Izmir Bay. Wastewater treatment improves the water quality. However, sediment does not respond to this treatment as fast as water column. Monitoring of bottom water and sediment quality is necessary for identification of the recovery of the whole ecosystem. For this purpose, bottom water and sediment samples were collected from three stations which are located in the middle and inner parts of the Izmir Bay on a monthly basis between January 2003 and December 2003. Values measured at stations ranged between; 0.54-12.82 microg/L for chlorophyll-a, 0.09-9.32 microg/L for phaeopigment, 0.05-1.91 mg/L for particulate organic carbon in bottom waters, 11.88-100.29 microg/g for chlorophyll degradation products and 1.12-5.39% for organic carbon in sediment samples. In conclusion, it was found that grazing activity explained carbon variations in sediment at station 2, but at station 1 and station 3 carbon variations in sediment were not related to autochthonous biological processes.  相似文献   

5.
Progress made in analytical techniques allows the formulation of new concepts in the biogeochemistry of organic carbon. The second part of our review summarizes the latest evolution and introduces new ideas in the biogeochemistry of marine dissolved organic carbon (DOC). Via classification of different fractions and sources of DOC, characterization of its composition, age and availability for bacterial utilization, and fate of DOC, we show the role of DOC in the global carbon cycle and the significance of bulk DOC in the oceans. Special emphasis is placed on the microbial loop in the cycling of DOC and its relation with higher trophic levels (phytoplankton and zooplankton). Significant progress has also been made in the study of the roles of colloidal organic material in metal complexation, ultraviolet radiation in dissolved organic matter photochemical oxidation, and chromophore-containing constituents of DOC as the signature of DOC for satellite observations. The importance of bulk DOC in the global carbon cycle requires the inclusion of this fraction in the regional and global carbon models. We predict that future DOC study in the ocean will focus on the development of sophisticated, almost continuously recording, moored DOC instrument arrays for the monitoring of small-scale DOC horizontal and vertical patchiness; widespread time series stations including estuarine, coastal and open environments; more detailed chemical characterization of different fractions of organic carbon from diverse marine habitats; parameterization of predictive models of DOC cycling on regional and global scales, incorporating the microbial loop; and finally, monitoring of DOC dynamics from satellites on regional and global scales.  相似文献   

6.
The concentration of Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, and Zn metals in water and sediments of Yamuna river were determined by atomic absorption spectrophotometry in the year 1981. The data showed that there was considerable variation in the concentration of elements from one sampling station to the other which may be due to the variation in the quality of industrial and sewage wasters being added to the river at different sampling stations. The sediment samples collected from different sampling stations were also analysed for calcium carbonate, organic matter, potassium, and phosphorus.  相似文献   

7.
Gradients in nutrient distributions and the effects of eutrophication are common features in most coastal marine areas. These structures occur in aquatic systems due to spatial differences in hydrography, nutrient loading and key biogeochemical processes. Two statistical methods, cluster analysis and probability mapping, have been used in the present study to determine characteristics and patterns in water quality variables. Combined, these two methods provide a useful tool to statistically determine spatial homogeneity and representativity of areas and stations. A case study is presented here in which water quality variables (salinity, dissolved inorganic nitrogen, dissolved inorganic phosphorus and chlorophyll) in surface waters of the Kattegat are analysed for the time period 1993-1997. It was found that morphology, the proximity to sources of nutrient loading from land, nutrient uptake and the infrequent water exchange between the Baltic Sea in the south and the Skagerrak in the north all contribute to create distinct regions of water quality. Regions with concentrations significantly different from the overall mean are identified. In addition to identification of regions with similar characteristics, representative stations (as well as not representative stations) for the respective regions were made. This type of information can be used to design new or revise old monitoring programs.  相似文献   

8.
Ongoing marine monitoring programs are seldom designed to detect changes in the environment between different years, mainly due to the high number of samples required for a sufficient statistical precision. We here show that pooling over time (time integration) of seasonal measurements provides an efficient method of reducing variability, thereby improving the precision and power in detecting inter-annual differences. Such data from weekly environmental sensor profiles at 21 stations in the northern Bothnian Sea was used in a cost-precision spatio-temporal allocation model. Time-integrated averages for six different variables over 6 months from a rather heterogeneous area showed low variability between stations (coefficient of variation, CV, range of 0.6–12.4%) compared to variability between stations in a single day (CV range 2.4–88.6%), or variability over time for a single station (CV range 0.4–110.7%). Reduced sampling frequency from weekly to approximately monthly sampling did not change the results markedly, whereas lower frequency differed more from results with weekly sampling. With monthly sampling, high precision and power of estimates could therefore be achieved with a low number of stations. With input of cost factors like ship time, labor, and analyses, the model can predict the cost for a given required precision in the time-integrated average of each variable by optimizing sampling allocation. A following power analysis can provide information on minimum sample size to detect differences between years with a required power. Alternatively, the model can predict the precision of annual means for the included variables when the program has a pre-defined budget. Use of time-integrated results from sampling stations with different areal coverage and environmental heterogeneity can thus be an efficient strategy to detect environmental differences between single years, as well as a long-term temporal trend. Use of the presented allocation model will then help to minimize the cost and effort of a monitoring program.  相似文献   

9.
A new sampling system has been developed for the measurement of time-averaged concentrations of organic micropollutants in aquatic environments. The system is based on the diffusion of targeted organic compounds through a rate-limiting membrane and the subsequent accumulation of these species in a bound, hydrophobic, solid-phase material. It provides a novel and robust solution to the problem of monitoring in situations where large temporal fluctuations in pollutant levels may occur. Accumulation rates are regulated by choice of diffusion-limiting membrane and bound solid-phase material and have been found to be dependent on the physico-chemical properties of individual target analytes. Two separate prototype systems are described: one suitable for the sampling of non-polar organic species with log octanol/water partition coefficient (log P) values greater than 4, the other for more polar species with log P values between 2 and 4. Both systems use the same solid-phase material (47 mm C18 Empore disk) as a receiving phase but are fitted with different rate-limiting membrane materials (polysulfone for the polar and polyethylene for the non-polar analytes). The two systems complement each other and together can be used for sampling a wider range of organic analytes than generally possible using current passive sampling techniques. Calibration data are presented for both devices. In each case, linear uptake kinetics were sustained, under constant conditions, for deployment periods of between 1 and 9 days. The effects of water temperature and turbulence on sampling rates have been quantitatively assessed. The performance of the system was further investigated by means of field exposures for one and two weeks in marine environments where calibrated samplers were used to determine the time-averaged concentrations of the polar biocides diuron and irgarol 1051. The quantitative results obtained using the passive sampler were compared with those obtained using spot sampling.  相似文献   

10.
Two carbon analysis methods are currently being applied to the occupational monitoring of diesel particulate matter. Both methods are based on thermal techniques for the determination of organic and elemental carbon. In Germany, method ZH 1/120.44 has been published. This method, or a variation of it, is being used for compliance measurements in several European countries, and a Comité Européen de Normalization Working Group was formed recently to address the establishment of a European measurement standard. In the USA, a 'thermal-optical' method has been published as Method 5040 by the National Institute for Occupational Safety and Health. As with ZH 1/120.44, organic and elemental carbon are determined through temperature and atmosphere control, but different instrumentation and analysis conditions are used. Although the two methods are similar in principle, they gave statistically different results in a previous interlaboratory comparison. Because different instruments and operating conditions are used, between-method differences can be expected in some cases. Reasonable agreement is expected when the sample contains no other (i.e., non-diesel) sources of carbonaceous particulate and the organic fraction is essentially removed below about 500 degrees C. Airborne particulate samples from some mines may meet these criteria. Comparison data on samples from mines are important because the methods are being applied in this workplace for occupational monitoring and epidemiological studies. In this paper, results of a recent comparison on samples collected in a Canadian mine are reported. As seen in a previous comparison, there was good agreement between the total carbon results found by the two methods, with ZH 1/120.44 giving about 6% less carbon than Method 5040. Differences in the organic and elemental carbon results were again seen, but they were much smaller than those obtained in the previous comparison. The relatively small differences in the split between organic and elemental carbon are attributed to the different thermal programs used.  相似文献   

11.
红枫湖水体中碳的时空分布特征分析   总被引:1,自引:0,他引:1  
基于2013年8月、10月、11月及2014年3月在红枫湖5个表层水样采集点、3个分层水样采集点测定的总碳、无机碳、总有机碳及二氧化碳数据,结合当时的气象数据对碳的时空分布特征讨论分析。结果表明,虽然调查期间同时间相同水层各个水样采集点的上述4个指标差异并不明显,但同一时间不同分层水体及各水样采集点不同季节在碳分布上存在一定差异。温度越高,光照越长,生物活性越强,湖体碳被生物利用的比例越大,总碳、无机碳、总有机碳含量就越低,较强的生物活性也伴随更多的二氧化碳产生。上、下层水体因光与温度差异所导致的碳分布差异会因季节性翻湖而消失。  相似文献   

12.
The effectiveness of different monitoring methods in detecting temporal changes in water quality depends on the achievable sampling intervals, and how these relate to the extent of temporal variation. However, water quality sampling frequencies are rarely adjusted to the actual variation of the monitoring area. Manual sampling, for example, is often limited by the level of funding and not by the optimal timing to take samples. Restrictions in monitoring methods therefore often determine their ability to estimate the true mean and variance values for a certain time period or season. Consequently, we estimated how different sampling intervals determine the mean and standard deviation in a specific monitoring area by using high frequency data from in situ automated monitoring stations. Raw fluorescence measurements of chlorophyll a for three automated monitoring stations were calibrated by using phycocyanin fluorescence measurements and chlorophyll a analyzed from manual water samples in a laboratory. A moving block bootstrap simulation was then used to estimate the standard errors of the mean and standard deviations for different sample sizes. Our results showed that in a temperate, meso-eutrophic lake, relatively high errors in seasonal statistics can be expected from monthly sampling. Moreover, weekly sampling yielded relatively small accuracy benefits compared to a fortnightly sampling. The presented method for temporal representation analysis can be used as a tool in sampling design by adjusting the sampling interval to suit the actual temporal variation in the monitoring area, in addition to being used for estimating the usefulness of previously collected data.  相似文献   

13.
This paper aims at evaluating and revising the spatial and temporal sampling frequencies of the water quality monitoring system of the Jajrood River in the Northern part of Tehran, Iran. This important river system supplies 23% of domestic water demand of the Tehran metropolitan area with population of more than 10 million people. In the proposed methodology, by developing a model for calculating a discrete version of pair-wise spatial information transfer indices (SITIs) for each pair of potential monitoring stations, the pair-wise SITI matrices for all water quality variables are formed. Also, using a similar model, the discrete temporal information transfer indices (TITIs) using the data of the existing monitoring stations are calculated. Then, the curves of the pair-wise SITI versus distance between monitoring stations and TITI versus time lags for all water quality variables are derived. Then, using a group pair-wise comparison matrix, the relative weights of the water quality variables are calculated. In this paper, a micro-genetic-algorithm-based optimization model with the objective of minimizing a weighted average spatial and temporal ITI is developed and for a pre-defined total number of stations, the best combination of monitoring stations is selected. The results show that the existing monitoring system of the Jajrood River should be partially strengthened and in some cases the sampling frequencies should be increased. Based on the results, the proposed approach can be used as an effective tool for evaluating, revising, or redesigning the existing river water quality monitoring systems.  相似文献   

14.
环境空气中VOC s 的监测技术新进展   总被引:15,自引:0,他引:15  
大气中的挥发性有机物(VOCs)严重威胁着人类的健康,目前对它的监测技术的研究越来越多.文章综述了近年来国内外在VOCs的采样及测试技术上的进展,重点介绍了固相微萃取、罐取样、吸附法等采样技术以及以气相色谱法为主的分析方法,并对一些非色谱法的分析技术进行了简单介绍.  相似文献   

15.
选择分布在不同流域的15个与自动监测站位置一致性较好的断面,对其进行为期1年的“同时同点位”对比监测。分析数据发现:由于采样时间和位置的偏差,自动监测月均值与常规手工监测数据的可比性并不理想。采用以下4种方法评价水质:自动5项、手动5项、手动21项、自动5项+手动16项。比较第1和第2种方法,水质评价类别相同与变化一类(发生一个水质类别变化)的占比之和在85%左右;比较第1和第3种方法,类别相同与变化一类的占比之和在80%左右;比较第3和第4种方法,类别相同与变化一类的占比之和接近90%,因此该组合是更合理的地表水水质评价方法。  相似文献   

16.
The TOC in surface waters and wastewater is an important analytical parameter describing the total content of all organic substances containing carbon. In practice, the TOC originated from natural and anthropogenic sources, and even if it is not directly responsible for dangers on human health, its determination is important for any kind of water that is used by public. The aim of this study was to determine variation of total organic carbon (TOC) and total carbon (TC) content in the stream Harsit, which courses in Eastern Black Sea Region, Turkey. Sampling was fortnightly conducted in each of the four seasons between March 2009 and February 2010. A total of 230 water samples were collected from ten sampling stations along the main branch of the stream Harsit with 143 km of length. Obtained TOC values were evaluated and used to classify the water quality of stream Harsit, according to the Turkish Water Pollution Control Regulation (TWPCR). The annual average TOC content values for the stations were found between 2.33 and 6.97 mg/L. It was seen that the TOC content have increased along the streamcourse of Harsit until the fourth station, where reaches its maximum value. The TOC content, then, has decreased and the minimum value was observed in the eighth station. The results showed that, except in winter season, maximum TOC content observed in many of the water samples were above Class I water standard indicated in TWPCR, which classifies the water resources according to the different area of uses. It was also found that TOC has a small contribution to TC and the highest TOC content in stream waters were measured in Gumushane station where direct discharge of city wastewaters and solid waste dumping to the stream were observed.  相似文献   

17.
Compared with sporadic conventional water sampling, continuous water-quality monitoring with optical sensors has improved our understanding of freshwater dynamics. The basic principle in photometric measurements is the incident light at a given wavelength that is either reflected, scattered, or transmitted in the body of water. Here, we discuss the transmittance measurements. The amount of transmittance is inversely proportional to the concentration of the substance measured. However, the transmittance is subject to interference, because it can be affected by factors other than the substance targeted in the water. In this study, interference with the UV/Vis sensor nitrate plus nitrite measurements caused by organic carbon was evaluated. Total or dissolved organic carbon as well as nitrate plus nitrite concentrations were measured in various boreal waters with two UV/Vis sensors (5-mm and 35-mm pathlengths), using conventional laboratory analysis results as references. Organic carbon increased the sensor nitrate plus nitrite results, not only in waters with high organic carbon concentrations, but also at the lower concentrations (< 10 mg C L?1) typical of boreal stream, river, and lake waters. Our results demonstrated that local calibration with multiple linear regression, including both nitrate plus nitrite and dissolved organic carbon, can correct the error caused by organic carbon. However, high-frequency optical sensors continue to be excellent tools for environmental monitoring when they are properly calibrated for the local water matrix.  相似文献   

18.
River water quality sampling frequency is an important aspect of the river water quality monitoring network. A suitable sampling frequency for each station as well as for the whole network will provide a measure of the real water quality status for the water quality managers as well as the decision makers. The analytic hierarchy process (AHP) is an effective method for decision analysis and calculation of weighting factors based on multiple criteria to solve complicated problems. This study introduces a new procedure to design river water quality sampling frequency by applying the AHP. We introduce and combine weighting factors of variables with the relative weights of stations to select the sampling frequency for each station, monthly and yearly. The new procedure was applied for Jingmei and Xindian rivers, Taipei, Taiwan. The results showed that sampling frequency should be increased at high weighted stations while decreased at low weighted stations. In addition, a detailed monitoring plan for each station and each month could be scheduled from the output results. Finally, the study showed that the AHP is a suitable method to design a system for sampling frequency as it could combine multiple weights and multiple levels for stations and variables to calculate a final weight for stations, variables, and months.  相似文献   

19.
The Tamsui River basin is located in Northern Taiwan and encompasses the most metropolitan city in Taiwan, Taipei City. The Taiwan Environmental Protection Administration (EPA) has established 38 water quality monitoring stations in the Tamsui River basin and performed regular river water quality monitoring for the past two decades. Because of the limited budget of the Taiwan EPA, adjusting the monitoring program while maintaining water quality data is critical. Multivariate analysis methods, such as cluster analysis (CA), factor analysis (FA), and discriminate analysis (DA), are useful tools for the statistically spatial assessment of surface water quality. This study integrated CA, FA, and DA to evaluate the spatial variance of water quality in the metropolitan city of Taipei. Performing CA involved categorizing monitoring stations into three groups: high-, moderate-, and low-pollution areas. In addition, this categorization of monitoring stations was in agreement with that of the assessment that involved using the simple river pollution index. Four latent factors that predominantly influence the river water quality of the Tamsui River basin are assessed using FA: anthropogenic pollution, the nitrification process, seawater intrusion, and geological and weathering processes. We plotted a spatial pattern using the four latent factor scores and identified ten redundant monitoring stations near each upstream station with the same score pattern. We extracted five significant parameters by using DA: total organic carbon, total phosphorus, As, Cu, and nitrate, with spatial variance to differentiate them from the polluted condition of the group obtained by using CA. Finally, this study suggests that the Taiwan EPA can adjust the surface water-monitoring program of the Tamsui River by reducing the monitoring stations to 28 and the measured chemical parameters to five to lower monitoring costs.  相似文献   

20.
Passive air sampling for nitrogen dioxide (NO(2)) and select volatile organic compounds (VOCs) was conducted at 24 fire stations and a compliance monitoring site in Dallas, Texas, USA during summer 2006 and winter 2008. This ambient air monitoring network was established to assess intra-urban gradients of air pollutants to evaluate the impact of traffic and urban emissions on air quality. Ambient air monitoring and GIS data from spatially representative fire station sites were collected to assess spatial variability. Pairwise comparisons were conducted on the ambient data from the selected sites based on city section. These weeklong samples yielded NO(2) and benzene levels that were generally higher during the winter than the summer. With respect to the location within the city, the central section of Dallas was generally higher for NO(2) and benzene than north and south. Land use regression (LUR) results revealed spatial gradients in NO(2) and selected VOCs in the central and some northern areas. The process used to select spatially representative sites for air sampling and the results of analyses of coarse- and fine-scale spatial variability of air pollutants on a seasonal basis provide insights to guide future ambient air exposure studies in assessing intra-urban gradients and traffic impacts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号