首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
爆炸形成过程中火焰加速的试验研究   总被引:1,自引:1,他引:0  
为预防和控制工业爆炸事故,并为脉冲爆轰发动机的研究提供理论指导,分析火焰加速导致的燃烧转爆轰过程的影响因素。采用爆轰管探讨障碍物的阻塞比、混合物的组成、初始压力和点火能等4个因素对爆炸性气体火焰速度和爆轰压力的影响规律。试验结果表明:障碍物的存在能大大提高火焰速度和爆轰压力;爆轰压力随管内障碍物阻塞比的增大先变大后减小,并在阻塞比为0.498,燃料种类为天然气,化学当量比为1时达到最大;爆轰压力还随混合气体初始压力的增大和点火能的提高而增大。选择适宜的条件可大大提高火焰加速速率,促进燃烧向爆轰过程转变。  相似文献   

2.
为了研究管道内氢气的爆燃转爆轰及其抑制过程,对单个障碍物管道中氢气-空气混合物燃爆过程以及多级泄爆进行了二维数值模拟。基于氢气-空气19步详细化学反应动力学机理,以及k-ε湍流模型、概率密度函数输运方程和同位网格SIMPLE算法,采用计算流体软件Fluent进行模拟。结果表明:密闭管道无泄爆时,在距点火端1.5 m左右爆燃转为爆轰;泄爆口的位置对管道内氢气-空气预混气体的爆炸参数有重要影响,泄爆口位于管道中部时,能降低管道内爆轰超压,泄爆效果较好;位于管道中部单个泄爆口泄爆时,有效降低爆轰超压,管道中部设置2个泄爆口时,能通过压力和混合气体的泄放将管道中已经发生的爆轰衰减为爆燃;当有3个泄爆口泄爆时,管道中没有发生爆轰,达到良好的泄爆效果。  相似文献   

3.
A large vapour cloud explosion (VCE) followed by a fire is one of the most dangerous and high consequence events that can occur in petrochemical facilities. The current process of safety practice in the industry in VCE assessment is to assume that all VCEs are deflagration. This assumption has been considered for nearly three decades. In recent years, major fire and VCE incidents in fuel storage depots gained considerable attention in extreme high explosion overpressure due to the transition from Deflagration to Detonation (DDT). Though the possibility of DDTs is lower than deflagrations, they have been identified in some of the most recent large-scale VCE incidents, including Buncefield (UK), 2005, San Juan explosion (US), 2009, and IOCL Jaipur (India), 2009 event. Such an incident established the need to understand not only VCE but also the importance of avoiding the escalation of minor incidents into much more devastating consequences.Despite decades of research, understanding of the fundamental physical mechanisms and governing factors of deflagration-to detonation transition (DDT) transition remains mostly elusive. An extreme multi-scale, multi-physics nature of this process uncertainly makes DDT one of the “Grand Challenge” problems of typical physics, and any significant developments toward its assured insistence would require revolutionary step forward in experiments, theory, and numerical modelling. Under certain circumstances, nevertheless, it is possible for DDT to occur, and this can be followed by a propagating detonation that quickly consumes the remaining detonable cloud. In a detonable cloud, a detonation creates the worst accident that can happen. Because detonation overpressures are much higher than those in a deflagration and continue through the entire detonable cloud, the damage from a DDT event is more severe. The consideration of detonation in hazard and risk assessment would identify new escalation potentials and recognize critical buildings impacted. This knowledge will allow more effective management of this hazard.The main conclusion from this paper is that detonations did occur in Jaipur accident at least part of the VCE accidents. The vapour cloud explosion could not have been caused by a deflagration alone, given the widespread occurrence of high overpressures and directional indicators in open uncongested areas containing the cloud. Additionally, the major incident has left many safety issues behind, which must be repeatedly addressed. It reveals that adequate safety measures were either underestimated or not accounted for seriously. This article highlights the aftermath of the IOCL Jaipur incident and addresses challenges put forward by it.  相似文献   

4.
The explosion and deflagration-to-detonation transition (DDT) in epoxy propane (E.P.) vapor/air mixture clouds under weak ignition conditions has been studied in an experimental tube of diameter 199 mm and length 29.6 m. E.P. vapor clouds were formed by injecting liquid E.P. into the experimental tube and evaporating of the fine E.P. droplets. The dimension and the evaporating process of the E.P. droplet were measured and analyzed. The E.P. vapor/air mixture clouds were ignited by an electric spark with an ignition energy of 40 J. The characteristics and the stages of the DDT process in the E.P. vapor/air mixtures have been studied and analyzed. A self-sustained detonation wave formed, as was evident from the existence of a transverse wave and a cellular structure. Moreover, a retonation wave formed during the DDT process in the E.P. vapor/air mixture. The influence of the E.P. vapor concentration on the DDT process has been studied. The minimum E.P. vapor concentration for the occurrence of the DDT in the E.P. vapor/air mixture has been evaluated and the variation of DDT distance with E.P. vapor concentration has been analyzed.  相似文献   

5.
为了研究障碍物对油气泄压爆炸火焰传播特性的影响规律,进行了不同数量障碍物工况下的对比实验,并利用纹影仪和高速摄影仪记录了火焰传播过程,针对障碍物对火焰形态、火焰锋面位置及火焰传播速度的影响规律进行了研究,结果表明:圆柱体障碍物会导致油气泄压爆炸火焰形态产生褶皱和弯曲变形,诱导层流火焰向湍流火焰转变,加速火焰的传播,对油气泄压爆炸火焰的初始传播形态有显著影响;随着障碍物数量的增多,火焰锋面传播距离点火端的最大距离增大,但到达最远距离的时间减少;障碍物能够增强火焰的传播速度,尤其对障碍物下游火焰影响最为显著,随着障碍物数量的增多,火焰传播的最大速度也随之增大,但达到最大火焰传播速度的时间却随之减少;障碍物的存在增大了油气泄压爆炸过程外部爆炸压力,并且随着障碍物数量的增多,外部爆炸压力峰值增长幅度增大。  相似文献   

6.
Experiments with hydrogen–air and ethylene–air mixtures at atmospheric pressure were carried out in a 6.1 m long, 0.1 m diameter tube with different obstacle configurations and ignition types. Classical DDT experiments were performed with the first part of the tube filled with equally spaced 75 mm (44% area blockage ratio) orifice-plates. The DDT limits, defining the so-called quasi-detonation regime, where the wave propagates at a velocity above the speed of sound in the products, were found to be well correlated with d/λ = 1, where d is orifice-plate diameter and λ is the detonation cell size. The only exception was the rich ethylene limit where d/λ = 1.9 was found. In a second experiment detonation propagation limits were measured by transmitting a CJ detonation wave into an obstacle filled (same equally spaced 44% orifice plates) section of the tube. An oxy-acetylene driver promptly initiated a detonation wave at one end. In this experiment the quasi-detonation propagation limits were found to agree very well with the d/λ = 1 correlation. This indicates that the d/λ = 1 represents a propagation limit. In general, one can conclude that the classical DDT limits measured in an orifice-plate filled tube are governed by the wave propagation mechanism, independent of detonation initiation (DDT process) that can occur locally in the obstacles outside these limits. For rich mixtures, transmission of the quasi-detonation into the smooth tube resulted in CJ detonation wave. However, in a narrow range of mixtures on the lean side, the detonation failed to transmit in the smooth tube. This highlights the critical role that shock reflection plays in the propagation of quasi-detonation waves.  相似文献   

7.
Methane/coal dust/air explosions under strong ignition conditions have been studied in a 199 mm inner diameter and 30.8 m long horizontal tube. A fuel gas/air manifold assembly was used to introduce methane and air into the experimental tube, and an array of 44 equally spaced dust dispersion units was used to disperse coal dust particles into the tube. The methane/coal dust/air mixture was ignited by a 7 m long epoxypropane mist cloud explosion. A deflagration-to-detonation transition (DDT) was observed, and a self-sustained detonation wave characterized by the existence of a transverse wave was propagated in the methane/coal dust/air mixtures.The suppressing effects on methane/coal dust/air mixture explosions of three solid particle suppressing agents have been studied. Coal dust and the suppressing agent were injected into the experimental tube by the dust dispersion units. The length of the suppression was 14 m. The suppression agents examined in this study comprised ABC powder, SiO2 powder, and rock dust powder (CaCO3). Methane/coal dust/air explosions can be efficiently suppressed by the suppression agents characterized by the rapid decrease in overpressure and propagating velocity of the explosion waves.  相似文献   

8.
The future widespread use of hydrogen as an energy carrier brings in safety issues that have to be addressed before public acceptance can be achieved. The prediction of the consequences of a major accident release of hydrogen into the atmosphere or the contamination of high-pressure hydrogen storage facilities by air entrainment requires a good knowledge of the explosion parameters of hydrogen–air mixtures. The present paper reviews and comments on the current knowledge of dynamic parameters of hydrogen detonation for hazard assessment. The major problem that remains to be resolved involves the understanding of the effect of turbulence on the cellular detonation structure, the propagation of high-speed deflagrations and the transition from deflagration to detonations. It is recommended that future research should be aimed towards experiments that permit the quantitative understanding of the mechanisms of high-speed turbulent combustion rather towards large-scale tests in complex geometries where minimal quantitative information of fundamental significance could be extracted. In spite of its wide flammability and sensitivity to ignition and detonation initiation, it is felt that hydrogen can be produced, stored and handled safely with the appropriate considerations in the design of the hydrogen facilities.  相似文献   

9.
An experimental system including pressure transducer, data acquisition card, computer and electric spark ignition device was set up to research methane-coal dust hybrid explosions in closed tubes with different types of obstacles inside. Its dynamic response time was less than a millisecond and the test precision was 0.1%. The experimental results show that the obstacles had great effects on the explosion characteristics in the tube. Hollow obstacles linked with inner wall of the tube induced faster pressure rising than installed center blocked solid obstacles. Obstacles with more sharp corner induce more violent explosions. The most dangerous explosion occurred when spacing between obstacles almost equaled the inner diameter of the tube for the same size obstacle.  相似文献   

10.
To study the occurrence conditions and propagation characteristics of deflagration to detonation transition (DDT) in linked vessels, two typical linked vessels were investigated in this study. The DDT of the methane–air mixture under different pipe lengths and inner diameters was studied. Results showed that the CJ detonation pressure of the methane–air mixture was 1.86 MPa, and the CJ detonation velocity was 1987.4 m/s. Compared with a single pipe, the induced distance of DDT is relatively short in the linked vessels. With the increase in pipeline length, DDT is more likely to occur. Under the same pipe diameter, the DDT induction distance in the vessel–pipe–vessel structure is shorter than that in the vessel–pipe structure. With the increase in pipeline diameter, the length of the pipe required to form the DDT is reduced. For linked vessels in which detonation formed, four stages, namely, slow combustion, deflagration, deflagration to detonation, and stable detonation, occurred in the vessels. Moreover, for a pipe diameter of 60 mm and a length of 8 m, overdriven detonation occurred in the vessel–pipe–vessel structure.  相似文献   

11.
The method described in this paper enabled reliable and accurate positioning of an overdriven detonation by calculation of shock wave velocities (detonation and retonation) for hydrogen explosions in a closed 18 m long horizontal DN150 pipe. This enabled an empirical correlation between the ignition position and the run-up distance to DDT to be determined. It was shown that the initial ability of the flame to expand unobstructed and the piston-like effect of burnt gas expanding against the closed end of the tube contributed to initial flame acceleration and hence were able to affect the run-up distance to overdriven detonation. Flame speeds and rates of initial pressure rise were also used to explain how these two competing effects were able to produce a minimum in the run-up distance to DDT. The shortest run-up distance to DDT, relative to the ignition position, for this pipe and gas configuration was found when the ignition position was placed 5.6 pipe diameters (or 0.9 m) from the closed pipe end. The shortest run-up distance to DDT relative to the end of the pipe was recorded when the ignition source was placed 4.4 pipe diameters or 0.7 m from the pipe end.  相似文献   

12.
为了研究对称障碍物条件下瓦斯爆炸压力波与火焰传播的耦合作用,在150 mm×150 mm×1 700 mm的有机玻璃瓦斯爆炸管道中,距离点火端不同距离安装0.5阻塞率的对称障碍物,进行8.5%甲烷体积分数的爆炸试验,采集瓦斯爆炸的超压信号并同步拍摄火焰传播图像。结果表明:火焰穿越板式对称障碍物的过程经历了火焰加速、火焰降速到火焰再加速的过程,火焰降速的时间仅为5 ms。距离点火焰源不同长度的对称障碍物在火焰加速过程中的作用存在明显差异,近点火源的障碍物作用主要为诱导湍流,远离点火源的障碍物作用主要为湍流增强。  相似文献   

13.
The paper reviews large scale experiments with various fuels in air where successful deflagration to detonation transition (DDT) took place. This includes a recent experiment disclosed in the Buncefield R&D program, where DDT developed in the propane/air mixture. The DDT occurred in branches of deciduous trees in a premixed stagnant mixture. An internal R&D investigation programme was initiated to better understand the phenomena. A large scale experiment in an open space with ethane air mixture is presented in the paper. The premixed mixture was ignited at the edge of the congested three-dimensional rigs which consisted of vertical and horizontal pipes. After ignition, the flame accelerated in the congestion and transitioned to detonation at the end of congestion. Stable detonation propagated through the remaining open and uncongested space.The flame acceleration process leading to DDT is scale dependent. It also depends on many parameters leading to a large investigation array and, significant cost. However, such R&D efforts aimed toward a safer plant design, i.e. the prevention of occurrence of a major accident, are a small fraction of a real accident cost.  相似文献   

14.
Results of experiments on critical conditions for flame acceleration and the deflagration-to-detonation transition in tubes with transverse venting are presented. Tests were made with hydrogen mixtures in two tubes (inner diameter of 46 and 92 mm) with obstacles. Ratios of vent area to total tube area were 0.2 and 0.4. Venting was shown to influence flame acceleration significantly. The greater the vent ratio, the more reactive the mixture necessary for development of fast flames. Critical conditions for flame acceleration in tubes with venting, expressed through a critical mixture expansion ratio σcr, were found to be σcr01+2, where σ0 is the critical value for a closed tube. Critical conditions for detonation onset in a vented tube were found to be very close to those in a closed tube with similar configuration of obstacles.  相似文献   

15.
为了研究彩虹粉引燃危险性,应用固体燃烧速率试验仪初步甄别了彩虹粉传播燃烧能力,发现堆垛状彩虹粉固体火焰传播危险性较低;采用粉尘爆炸筛选装置,判定彩虹粉具有爆炸性;应用最小点火能测定装置测定彩虹粉粉尘云的最小点火能在24~60 mJ之间,最优爆炸浓度为1 167 g/m3;应用快速筛选量热仪测试,彩虹粉在227℃开始分解;固体自燃点测试仪显示彩虹粉在250℃附近会发生自燃。向彩虹粉内添加不同比例相近粒径分布的食用盐粉体进行抑爆研究,结果证明食用盐对彩虹粉具有明显的抑爆效果。  相似文献   

16.
Although industrial denotations in semi-open and congested geometries are often neglected by many practitioners during risk assessment, recent studies have shown that industrial detonations might be more common than previously believed. Therefore, from the explosion safety perspective, it becomes imperative to better assess industrial detonation hazards to improve robustness of explosion mitigation design, emergency response procedures, and building siting evaluation. Having that in mind, this study aims to review current empirical vapor cloud explosion models, understand their limitations, and assess their capability to indicate detonation onset for elongated vapor clouds. Six models were evaluated in total: TNO Multi-Energy, Baker-Strehlow-Tang (BST), Congestion Assessment Method (CAM), Quest Model for Estimation of Flame Speed (QMEFS), Primary Explosion Site (PES), and Confinement Specific Correlation (CSC). Model estimations were compared with large-scale test data available in the open literature. The CAM model demonstrated good performance in indicating deflagration-to-detonation transition (DDT) for test conditions experiencing detonation onset without any modification in the methodology. Some suggestions are provided to improve simulation results from PES, BST and QMEFS.  相似文献   

17.
Among the factors influencing dust explosion, the particle size distribution (PSD) is both one of the most important and complex to consider. For instance, it is commonly accepted that the explosion sensitivity increases when the particle size decreases. Such an assertion may be questionable for nano-objects which easily agglomerate. However, agglomerates can be broken during the dispersion process. Correlating the explosion parameters to the actual PSD of a dust cloud at the moment of the ignition becomes then essential. The effects of the moisture content and sieving were investigated on a nanocellulose powder and the impact of a mechanical agglomeration was evaluated using a silicon coated by carbon powder. Each sample was characterized before and after dispersion using in situ laser particle size measurement and a fast mobility particle sizer, and explosion and minimum ignition energy tests were conducted respectively in a 20 L sphere and in a modified Hartmann tube. It was observed that drying and/or sieving the nanocellulose mainly led to variations in terms of ignition sensitivity but only slightly modified the explosion severity. In contrast, the mechanical agglomeration of the silicon coated by carbon led to a great decrease in terms of ignition sensitivity, with a minimum ignition energy varying from 5 mJ for the raw powder to more than 1J for the agglomerated samples. The maximum rate of pressure rise also decreased due to modifications in the reaction kinetics, inducing a transition from St2 class to St1 class when agglomerating the dust.  相似文献   

18.
There is a general lack of information on the effects of full-bore obstacles on combustion in the literature, these obstacles are prevalent in many applications and knowledge of their effects on phenomena including burning rate, flame acceleration and DDT is important for the correct placing of explosion safety devices such as flame arresters and venting devices. In this work methane, propane, ethylene and hydrogen–air explosions were investigated in an 18 m long DN150 closed pipe with a 90 degree bend and various baffle obstacles placed at a short distance from the ignition source. After carrying out multiple experiments with the same configuration it was found that a relatively large variance existed in the measured flame speeds and overpressures, this was attributed to a stochastic element in how flames evolved and also how they caused and interacted with turbulence to produce flame acceleration. This led to several experiments being carried out for one configuration in order to obtain a meaningful average. It was shown that a 90 degree bend in a long tube had the ability to enhance flame speeds and overpressures, and shorten the run-up distance to DDT to a varying degree for a number of gases. In terms of the qualitative effects on these parameters they were comparable to baffle type obstacles with a blockage ratios of between 10 and 20%.  相似文献   

19.
A study on the obstacle-induced variation of the gas explosion characteristics   总被引:13,自引:0,他引:13  
A study on the variation of the gas explosion characteristics caused by the built-in obstacles was conducted in enclosed/vented gas explosion vessels. It has been well known that the obstacles in pipes and long ducts would accelerate the flame propagation, and cause the transition from deflagration to detonation. In this study, the explosion characteristics and the flame behavior of vented explosions and constant-volume explosions were investigated. Experiments were carried out in a 270-liter and 36-liter hexahedron vessels filled with LPG–air mixture. The explosion characteristics of the gas mixture were determined by using a strain-responding pressure transducer. The flame behavior was recorded by using a high-speed video camera. The shape and the size of the obstacle, and the gas concentration, were adjusted in the experiments.

It can be seen from the experimental results that, instead of being accelerated, the flame propagation inside the explosion vessel is decelerated by the plate obstacles fixed at the bottom of the vessel. Also, the characteristics of the enclosed explosion are not so affected by the built-in obstacles as those of the vented explosion are. It is believed that the eddy-induced turbulence behind the obstacle decelerates the flame propagation.  相似文献   


20.
The structure of the steady planar detonation wave is analyzed for three-step chain-branching kinetics consistent with hydrogen–air chemistry. The initiation and chain-branching steps are described by an Arrhenius rate. Both are thermally neutral, so that heat release is due to termination. The initiation rate is typically very low and very stiff. As a result, a small fraction of the reactant is consumed in the initiation region, which is very long but ends in an exponential chain-branching explosion. Next, the reactant is rapidly converted into chain-branching radicals, within a very thin zone, which ends when the concentration of the chain-branching radical reaches a peak, because of reactant depletion. Finally, the termination step consumes the chain-branching radicals and releases heat within a region thicker than the peak zone, but much thinner than the initiation region. The analysis is based upon two assumptions: that the chain-branching activation energy is high and that initiation is slow. The structure of the initiation and chain-branching zones is different for post-shock states within or outside the explosion region in the chain-branching diagram. In the former situation, chain-branching is already stronger than termination at the von Neumann point, and vice versa. In the no-explosion case, the initiation zone becomes very long, while the little chain-branching specie produced by initiation is directly converted into product by the termination step. Temperature increases slowly until reaching the explosion curve, when chain-branching becomes stronger than termination. The subsequent structure is similar to the explosion case.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏