首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
The overpressure generated in a 10 L cylindrical vented vessel with an L/D of 2.8 was investigated, with end ignition opposite the vent, as a function of the vent static burst pressure, Pstat, from 35 to 450 mb. Three different Kv (V2/3/Av) of 3.6, 7.2 and 21.7 were investigated for 10% methane–air and 7.5% ethylene–air. It was shown that the dynamic burst pressure, Pburst, was higher than Pstat with a proportionality constant of 1.37. For 10% methane–air Pburst was the controlling peak pressure for K <∼8. This was contrary to the assumption that Pred > Pburst in the literature and in EU and US standards. For higher Kv the overpressure due to flow through the vent, Pfv, was the dominant overpressure and the static burst pressure was not additive to the external overpressure. Literature on the influence of Pstat at low Kv was shown to support the present finding and it is recommended that the influence of Pstat in gas venting standards is revised.  相似文献   

2.
A study of vented explosions in a length over diameter (L/D) of 2 in cylindrical vessel connecting with a vent duct (L/D = 7) is reported. The influence of vent burst pressure and ignition locations on the maximum overpressure and flame speeds at constant vent coefficient, K of 16.4 were investigated to elucidate how these parameters affect the severity of a vented explosion. Propane and methane/air mixtures were studied with equivalence ratio, Φ ranges from 0.8 to 1.6. It is demonstrated that end ignition exhibited higher maximum overpressures and flame speeds in comparison to central ignition, contrary to what is reported in literature. There was a large acceleration of the flame toward the duct due to the development of cellular flames and end ignition demonstrated to have higher flame speeds prior to entry into the vent due to the larger flame distance. The higher vent flow velocities and subsequent flame speeds were responsible for the higher overpressures obtained. Rich mixtures for propane/air mixtures at Φ = 1.35 had the greatest flame acceleration and the highest overpressures. In addition, the results showed that Bartknecht's gas explosion venting correlation is grossly overestimated the overpressure for K = 16.4 and thus, misleading the impact of the vent burst pressure.  相似文献   

3.
Experiments were conducted in a 1 m3 vessel with a top vent to investigate the effect of methane concentration and ignition position on pressure buildup and flame behavior. Three pressure peaks (p1, p2, and Pext) and two types of pressure oscillations (Helmholtz and acoustic oscillations) were observed. The rupture of vent cover results in p1 that is insensitive to methane concentration and ignition position. Owing to the interaction between acoustic wave and the flame, p2 forms in the central and top ignition explosions when the methane–air mixture is near–stoichiometric. When the methane–air mixture is centrally ignited, p2 first increases and then decreases with an increase in the methane concentration. The external explosion-induced Pext is observed only in the bottom ignition explosions with an amplitude of several kilopascals. Under the current experimental conditions, flame–acoustic interaction leads to the most serious explosions in central ignition tests. Methane concentration and ignition position have little effect on the frequency of Helmholtz and acoustic oscillations; however, the Helmholtz oscillation lasts longer and first decreases and then increases as the methane concentration increases for top ignition cases. The ignition position significantly affects the Taylor instability of the flame front resulting from the Helmholtz oscillation.  相似文献   

4.
To further elucidate the influence mechanism of side vents on the dynamic characteristics of gas explosions in tubes is helpful to design more reasonable vent layouts. In this paper, 9.5% methane-air explosion experiments were conducted in a tube with two side-vented ducts, and the effects of vent layouts and vent areas on the dynamic characteristics of explosion overpressure and flame propagation speed were investigated. The results demonstrate that under the same condition with a single vent area of 100 mm × 100 mm, when only the end vent is open, the maximum explosion overpressure and the maximum flame propagation speed are the highest among the five vent layouts. When the side vents 1 and 2 and the end vent are open, the maximum explosion overpressure is the lowest, and an unusual discovery is that the flame front changes into a hemispherical shape, finger shape, quasi-plane shape, tulip shape and wrinkled structure. When only side vent 1 is open, a unique Helmholtz oscillation occurs, and a new discovery is that there is a consistent oscillation relationship among the overpressure, flame propagation speed and flame structure. Helmholtz oscillation occurs only when a single vent area is 100 mm × 100 mm–60 mm × 60 mm, and the oscillation degree decreases with decreasing vent area. During the vent failure stage, the maximum explosion overpressure is generated, the flame front begins to appear irregular shape, and the flame propagation speed shows a prominent characteristic peak. After the vent failure stage, the driving effect of the end vent on the flame is higher than that of the side vent on the flame. Furthermore, the correlation equations of the mathematical relationships among the maximum explosion overpressure Pred, the static activation pressure Pstat and the vent coefficient Kv under four vent layouts are established, respectively.  相似文献   

5.
A set of 34 experiments on vented hydrocarbon–air and hydrogen–air deflagrations in unobstructed enclosures of volume up to 4000 m3 was processed with use of the advanced lumped parameter approach. Reasonable compliance between calculated pressure–time curves and experimental pressure traces is demonstrated for different explosion conditions, including high, moderate, low and extremely low reduced overpressures in enclosures of different shape (Lmax:Lmin up to 6:1) with different type and position of the ignition source relative to the vent, for near-stoichiometric air mixtures of acetone, methane, natural gas and propane, as well as for lean and stoichiometric hydrogen–air mixtures. New data were obtained on flame stretch for vented deflagrations.The fundamental Le Chatelier–Brown principle analog for vented deflagrations has been considered in detail and its universality has been confirmed. The importance of this principle for explosion safety engineering has been emphasized and proved by examples.A correlation for prediction of the deflagration–outflow interaction number, χ/μ, on enclosure scale, Bradley number and vent release pressure is suggested for unobstructed enclosures and a wide range of explosion conditions. Fractal theory has been employed to verify the universality of the dependence revealed of the deflagration–outflow interaction number on enclosure scale.In spite of differences between the thermodynamic and kinetic parameters of hydrocarbon–air and hydrogen–air systems, they both obey the same general regularities for vented deflagrations, including the Le Chatelier–Brown principle analog and the correlation for deflagration–outflow interaction number.  相似文献   

6.
In order to investigate the effects of branch tunnels on explosion propagation, experiments were performed in five different configuration tunnels (straight configuration and configurations with 1 branch, 2 branches, 3 branches and 4 branches). Pressure and flame transducers were used to record the history of the pressure development and track the velocity of the flame front. It was shown that the branch tunnels had ability to enhance the maximum overpressure, rate of overpressure rise, and deflagration index (KG) of the gasoline–air mixture explosion due to the turbulence induced by the branch tunnels. The overpressure rise rate and KG of the explosion increased as a function of the number of branch tunnels. Experiments also showed that the maximum flame speed increased as the branch number increasing from 0 to 3 due to the enlargement of turbulence induced by the branch tunnels. However, an increase of branch number did not always lead to an enhancement of flame speed because the heat loss was intensified resulting from the increase of flame surface caused by the branch tunnels. When the number of branch tunnels exceeded 3, the maximum flame speed dropped.  相似文献   

7.
Experimental data from vented explosion tests using gasoline-air mixtures with concentrations from 0.88 to 2.41% vol. are presented. A 2L vessel was used for the tests with vent sizes of 25 cm2, 50 cm2 and 100 cm2. The tests were focused on the effect of gasoline vapor concentration and vent size on the pressure development and the flame behavior inside and outside the vessel. It was found that the inner flame propagation speed was mainly dependent on the initial concentration, while the maximum flame spreading distance was mainly influenced by the vent size. The external flame speed and duration could be influenced by the combination of the two properties. The internal pressure increases gradually with the flame propagated inside the vessel and decreased sharply when the vent failed. High-pressure durations containing pressure peaks were recorded by transducers in front of the vent and oscillations could be observed besides the vent. At any measure point, the maximum external pressures for A = 25 cm2 or 50 cm2 were significantly larger than those for A = 100 cm2.  相似文献   

8.
This paper presents a model and simulation results for the mitigation of a hydrogen–air deflagration by venting through a duct. A large eddy simulation (LES) model, applied previously to study both closed-vessel, and open atmosphere hydrogen–air deflagrations, was developed further to model a hydrogen–air explosion vented through a duct. Sub-grid scale (SGS) flame wrinkling factors were introduced to model major phenomena which contribute to the increase of flame surface area in vented deflagrations. Simulations were conducted to validate the model against 20% hydrogen–air mixture deflagrations (vent diameters 25 and 45 cm) and 10% hydrogen–air mixture deflagration (vent diameter 25 cm). There was reasonable correlation between the simulations and the experimental data. The comparative importance of different physical phenomena contributing to the flame wrinkling is discussed.  相似文献   

9.
A series of medium-scale experiments on vented hydrogen deflagration was carried out at the KIT test side in a chamber of 1 × 1 × 1 m3 size with different vent areas. The experimental program was divided in three series: (1) uniform hydrogen–air mixtures; (2) stratified hydrogen–air mixtures within the enclosure; (3) a layer deflagration of uniform mixture. Different uniform hydrogen–air mixtures from 7 to 18% hydrogen were tested with variable vent areas 0.01–1.0 m2. One test was done for rich mixture with 50% H2. To vary a gradient of concentration, all the experiments with a stratified hydrogen–air mixtures had about 4%H2 at the bottom and 10 to 25% H2 at the top of the enclosure. Measurement system consisted of a set of pressure sensors and thermocouples inside and outside the enclosure. Four cameras combined with a schlieren system (BOS) for visual observation of combustion process through transparent sidewalls were used. Four experiments were selected as benchmark experiments to compare them with four times larger scale FM Global tests (Bauwens et al., 2011) and to provide experimental data for further CFD modelling. The nature of external explosion leading to the multiple pressure peak structure was investigated in details. Current work addresses knowledge gaps regarding indoor hydrogen accumulations and vented deflagrations. The experiments carried out within this work attend to contribute the data for improved criteria for hydrogen–air mixture and enclosure parameters to avoid unacceptable explosion overpressure. Based on theoretical analysis and current experimental data a further vent sizing technology for hydrogen deflagrations in confined spaces should be developed, taking into account the peculiarities of hydrogen–air mixture deflagrations in presence of obstacles, concentration gradients of hydrogen–air mixtures, dimensions of a layer of flammable cloud, vent inertia, etc.  相似文献   

10.
This study investigated methane-air explosion in tunnel-shape space and developed an overpressure-time history model based on numerical results. The findings revealed that for the progressively vented gas explosion with movable steel obstacles in a 20 m long tunnel, the inner peak overpressure increased as the activation pressure of the tunnel top cover got higher but remained below 6 bar. However, as the activation pressure increased to 8 bar or higher, the peak inner overpressure remained unchanged. As the segment cover panel became wider, the peak pressure was almost unchanged, but the pressure duration and impulse declined significantly. The peak pressure and impulse increased as the tunnel length vary from 10 to 30 m. With fixed tunnel length, higher blast pressure but lower impulse was observed as the inner obstacles were closer or the activation pressure of obstacles was higher. It is also found that a local enlarged space in the tunnel enhanced the peak pressure significantly. An overpressure time history model for the tunnel with fixed top cover and enlarged end zone was established. The model considered activation pressure of vent cover, area and length of vent opening, methane concentration, number and blockage ratio of fixed obstacles was developed to calculate the overpressure and corresponding time at characteristic points of the pressure-history curve. The cubic Hermite interpolation algorithm and a specially tuned formula consisting of the power and exponential function were used to interpolate pressure values between characteristic points. The proposed model can predict both the peak pressure and the overpressure time history with acceptable accuracy.  相似文献   

11.
A vented chamber, with internal dimensions of 150 mm × 150 mm × 500 mm, is constructed in which the premixed methane–air deflagration flame, propagating away from the ignition source, interacts with obstacles along its path. Three obstacle configurations with different cross-wise positions are investigated. The cross-wise obstacle positions are found to have significant effects on deflagration characteristics, such as flame structure, flame front location, flame speed, and overpressure transients. The rate of flame acceleration, as the flame passes over the last obstacle, is the highest at the configuration with three centrally located obstacles, whereas the lowest is observed at the configuration with three obstacles mounted on one side of the chamber. Compared with the side configuration, the magnitude of overpressure generated increases by approximately 80% and 165% for the central and staggered configurations, respectively. Furthermore, flame propagation speeds and generated overpressures for both the central and staggered configurations are greater, which should to be avoided to reduce the risk associated with turbulent premixed deflagrations in practical processes.  相似文献   

12.
The effect of the vent burst pressure on explosion venting of a rich methane-air mixture was experimentally investigated in a small cylindrical vessel. The experimental results show that Helmholtz oscillation of the internal flame bubble of the methane-air mixture can occur in a vessel with a vent area much smaller than that reported by previous researchers, and the period of Helmholtz oscillation decreases slightly when the vent burst pressure increases. The maximum overpressure in the vessel increases approximately linearly with the increase in the vent burst pressure; however, the pressure peaks induced by Helmholtz oscillation always remain approximately several kilopascals. The external flame reaches its maximum length in a few milliseconds after vent failure and then oscillates in accordance with the pressure oscillation in the vessel. The maximum length of the external flame increases, but its duration time decreases with the increase in the vent burst pressure.  相似文献   

13.
In the present work, a series of experiments have been performed to analyze the explosion characteristics of ethanol-gasoline with various blended ratios (0%, 5%, 10%, 15%, 30%, 50%, 70%, 80%, and 100%). A vented rectangular vessel with a cross-section of 100 mm × 100 mm, 600 mm long and a 40 mm diameter vent on the top is used to carry out the experiments. The flame propagation is recorded by a phantom high-speed camera with 5000 fps, while the histories of the explosion overpressure are measured by two PCB pressure sensors and the explosion sound pressure level is obtained by a CRY sound sensor. The results indicate that the maximum overpressure and flame propagation speed increases linearly as the blended ratio increases when the initial volume of blended fuel is 1.0 mL; While the change of explosion overpressure and flame propagation speed shows a trend of decreasing at first and then increasing as the concentration increases to 1.8 mL. It is also found that the peak of the sound pressure level exceeds 100 dB under all tests, which would damage the human's hearing. What's more, relationships between explosion overpressure and sound pressure level are examined, and the change of the maximum overpressure can be reflected to some extent by the measurement of the maximum sound pressure level. The study is significant to reveal the essential characteristic of the explosion venting process of ethanol-gasoline under different initial blended ratios, and the results would help deepen the understanding of ethanol-gasoline blended fuels explosion and the assessment of the explosion hazardous.  相似文献   

14.
The nature of coherent deflagration phenomena in a vented enclosure-atmosphere system is analysed. The study is based on experimental observations of SOLVEX programme in the empty 547-m3 vented enclosure and consequent analysis of the same test by large eddy simulations (LES). A comparison between simulated and experimental pressure transients and dynamics of flame front propagation inside and outside the enclosure gave an insight into the nature of the complex simultaneous interactions between flow, turbulence and combustion inside the enclosure and in the atmosphere. It is revealed through LES processing of experimental data that the substantial intensification of premixed combustion occurs only outside the empty SOLVEX enclosure and this leads to steep coherent pressure rise in both internal and external deflagrations. The external explosion does not affect burning rate inside the enclosure. There is only one ad hoc parameter in the LES model, which is used to account for unresolved subgrid scale increase of flame surface density outside the enclosure. The model allows reaching an excellent match between theory and experiment for coherent deflagrations in the empty SOLVEX facility. The mechanism of combustion intensification in the atmosphere is discussed and the quantitative estimation of the model ad hoc parameter is given.  相似文献   

15.
A 20 L spherical explosive device with a venting diameter of 110 mm was used to study the vented pressure and flame propagation characteristics of corn dust explosion with an activation pressure of 0.78–2.1 bar and a dust concentration of 400∼900 g/m3. And the formation and prevention of secondary vented flame are analyzed and discussed. The results show that the maximum reduced explosion overpressure increases with the activation pressure, and the vented flame length and propagation speed increase first and then decrease with time. The pressure and flame venting process models are established, and the region where the secondary flame occurs is predicted. Whether there is pressure accompanying or not in the venting process, the flame venting process is divided into two stages: overpressure venting and normal pressure venting. In the overpressure venting stage, the flame shape gradually changes from under-expanded jet flame to turbulent jet flame. In the normal pressure venting stage, the flame form is a turbulent combustion flame, and a secondary flame occurs under certain conditions. The bleed flames within the test range are divided into three regions and four types according to the shape of the flame and whether there is a secondary flame. The analysis found that when the activation pressure is 0.78 bar and the dust concentration is less than 500 g/m3, there will be no secondary flame. Therefore, to prevent secondary flames, it is necessary to reduce the activation pressure and dust concentration. When the dust concentration is greater than 600 g/m3, the critical dust concentration of the secondary flame gradually increases with the increase of the activation pressure. Therefore, when the dust concentration is not controllable, a higher activation pressure can be selected based on comprehensive consideration of the activation pressure and destruction pressure of the device to prevent the occurrence of the secondary flame.  相似文献   

16.
This study investigates the effect of the ignition position on vented hydrogen-air deflagration in a 1 m3 vessel and evaluates the performance of the commercial computational fluid dynamics (CFD) code FLACS in simulating the vented explosion of hydrogen-air mixtures. First, the differences in the measured pressure-time histories for various ignition locations are presented, and the mechanisms responsible for the generation of different pressure peaks are explained, along with the flame behavior. Secondly, the CFD software FLACS is assessed against the experimental data. The characteristic phenomena of vented explosion are observed for hydrogen-air mixtures ignited at different ignition positions, such as Helmholtz oscillation for front ignition, the interaction between external explosion and combustion inside the vessel for central ignition, and the wall effect for back-wall ignition. Flame-acoustic interaction are observed in all cases, particularly in those of front ignition and very lean hydrogen-air mixtures. The predicted flame behavior agree well with the experimental data in general while the simulated maximum overpressures are larger than the experimental values by a factor of 1.5–2, which is conservative then would lead to a safe design of explosion panels for instance. Not only the flame development during the deflagration was well-simulated for the different ignition locations, but also the correspondence between the pressure transients and flame behavior was also accurately calculated. The comparison of the predicted results with the experimental data shows the performance of FLACS to model vented mixtures of hydrogen with air ignited in a lab scale vessel. However, the experimental scale is often smaller than that used in practical scenarios, such as hydrogen refueling installations. Thus, future large-scale experiments are necessary to assess the performance of FLACS in practical use.  相似文献   

17.
Combustible dust explosions continue to present a significant threat toward operating personnel and pneumatic conveyance equipment in a wide variety of processing industries. Following ignition of suspended fuel within a primary enclosure volume, propagation of flame and pressure fronts toward upstream or downstream interconnected enclosures can result in devastating secondary explosions if not impeded through an appropriate isolation mechanism. In such occurrences, an accelerated flame front may result in flame jet ignition within the secondary vessel, greatly increasing the overall explosion severity. Unlike an isolated deflagration event with quantifiable reduced pressures (vent sizing according to NFPA 68 guidance), oscillation of pressure between primary and secondary process vessels leads to uncertain overpressure effects. Dependent on details of the application such as relative enclosure volumes, relief area, fuel type, suspended concentration, duct size, and duct length, the maximum system pressure in both interconnected vessels can be unpredictable. This study proposes the use of FLame ACceleration Simulator (FLACS) computational fluid dynamics (CFD) modeling to provide reliable consequence predictions for specific case scenarios of dust deflagrations involving interconnected equipment. Required minimum supplement to the originally calculated relief area (Av) was determined through iterative simulation, allowing for reduced explosion pressures (Pred) to be maintained below theoretical enclosure design strengths (Pes).  相似文献   

18.
为探究狭长受限空间中油气爆炸失控时的发展状态,探索高效环保的油气爆炸抑制方法,利用长径比155的管道开展92号汽油-空气混合气爆炸发展规律和七氟丙烷主动抑爆技术研究。通过测量不同端部开口条件下油气爆炸超压、火焰传播速度、火焰强度等参数,对比研究空爆和抑爆工况下的油气爆炸变化规律,探讨长直管道中的油气爆炸特性,分析七氟丙烷抑爆效果。结果表明:大长径比管道中,端部开口泄爆对降低油气爆炸破坏能力的作用较小,开口与否对最大超压峰值的出现位置有影响;长直管道空爆时,油气爆炸由爆燃发展成爆轰,管道尾部的爆轰波速可达近2 000 m/s;密闭管道中,爆轰发生前火焰传播呈“已燃区-火焰锋面-待燃区-前驱激波-未燃区”的2波3区结构;主动抑爆方式下七氟丙烷抑爆效果良好,最大超压峰值降低幅度可达90%,火焰传播被及时阻断。  相似文献   

19.
In order to better assess the hazards of explosion accidents, propane-air mixture deflagrations were conducted in a large-scale straight rectangular chamber (with a cross-section of 1.5 m × 1.5 m, length of 10 m, and total volume of 22.5 m3). The effect of initial volume, ignition position, and initial restraints on the explosion characteristics of the propane-air mixtures was investigated. The explosion overpressure, flame propagation, and flame speed were obtained and the computational fluid dynamics (CFD) software was used to simulate the flame-propagation process and field flow for auxiliary analysis. The hazards of large-scale propagation explosion under weak and strong constraints were evaluated and the different phases of flame propagation under weak and strong constraints were discriminated. Results indicate that the hazards caused by propane deflagration under weak constraint are mainly caused by flame spread. And the maximum overpressure under strong constraint appeared at the front part of the chamber under the large-scale condition, which is consistent with the previous small-scale test. Moreover, the simulations of flame structures under weak and strong constraint are in good agreement with experimental results, which furthers the understanding of large-scale propane deflagration under different initial conditions in large-scale spaces and provides basic data for three-dimensional CFD model improvement.  相似文献   

20.
利用球型容器与管道组合,开展连通容器气体爆炸与泄爆实验,分析连通条件下,火焰在管道中的传播过程及其对起爆容器和传爆容器的压力影响。实验结果表明:连通容器气体爆炸中,火焰从起爆容器到传爆容器传播经历了一段不断加速,但加速度不断减小的过程;泄爆过程中,火焰传播过程与密闭爆炸时基本一致。管道中火焰加速传播,使得传爆容器的爆炸压力和强度相较于作为起爆容器时均明显增加,危险更大,采用与起爆容器相同的泄爆面积,无法满足对连通容器中传爆容器的泄爆。同时,泄爆是一个快速的能量泄放过程应选择合理的泄爆方式,防止二次危害。  相似文献   