首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The U.S. Department of Energy (US DOE) remediation responsibilities include its Idaho National Laboratory. In 1989, the U.S. Environmental Protection Agency placed the Idaho site on its National Priority List for environmental cleanup. The site's contamination legacy from operations included inactive reactors and other structures, spent nuclear fuel, high‐level liquid radioactive wastes, calcined radioactive wastes, and transuranic wastes. Documents governing cleanup include a 1995 Settlement Agreement between the US DOE and the US Navy as responsible parties, and the State of Idaho. The Subsurface Disposal Area contains buried transuranic wastes, lies above the East Snake River Plain Aquifer, and could be the “site's most nettlesome cleanup issue,” according to an outside observer. This article describes the technical and legal difficulties that have been encountered in remediating this area. © 2010 Wiley Periodicals, Inc.  相似文献   

2.
A former bulk fuel terminal in North Carolina is a groundwater phytoremediation demonstration site where 3,250 hybrid poplars, willows, and pine trees were planted from 2006 to 2008 over approximately 579,000 L of residual gasoline, diesel, and jet fuel. Since 2011, the groundwater altitude is lower in the area with trees than outside the planted area. Soil‐gas analyses showed a 95 percent mass loss for total petroleum hydrocarbons (TPH) and a 99 percent mass loss for benzene, toluene, ethylbenzene, and xylenes (BTEX). BTEX and methyl tert‐butyl ether concentrations have decreased in groundwater. Interpolations of free‐phase, fuel product gauging data show reduced thicknesses across the site and pooling of fuel product where poplar biomass is greatest. Isolated clusters of tree mortalities have persisted in areas with high TPH and BTEX mass. Toxicity assays showed impaired water use for willows and poplars exposed to the site's fuel product, but Populus survival was higher than the willows or pines on‐site, even in a noncontaminated control area. All four Populus clones survived well at the site. © 2014 Wiley Periodicals, Inc.*  相似文献   

3.
Conventional methods to estimate groundwater velocity that rely on Darcy's Law and average hydrogeologic parameter values are insensitive to local‐scale heterogeneities and anisotropy that control advective flow velocity and direction. Furthermore, at sites that are tidally influenced or have extraction wells with variable pumping schedules, infrequent water‐level measurements may not adequately characterize the range and significance of transient hydraulic conditions. The point velocity probe (PVP) is a recently developed instrument capable of directly measuring local‐scale groundwater flow velocity and direction. In particular, PVPs may offer distinct advantages for sites with complex groundwater–surface water interactions and/or with spatially and temporally variable groundwater flow conditions. The PVP utilizes a small volume of saline tracer and inexpensive sensors to directly measure groundwater flow direction and velocity in situ at the centimeter‐scale and discrete times. The probes are installed in conventional direct‐push borings, rather than in wells, thus minimizing the changes and biases in the local flow field caused by well installation and construction. Six PVPs were installed at a tidally influenced site in North Carolina to evaluate their implementability, performance, and potential value as a new site characterization tool. For this study, a new PVP prototype was developed using a rapid prototyping machine (i.e., a “three‐dimensional printer'') and included both horizontally and vertically oriented tracer detectors. A site‐specific testing protocol was developed to account for the spatially and temporally variable hydraulic conditions and groundwater salinity. The PVPs were tested multiple times, and the results were compared to the results of several different groundwater flux and velocity estimation tools and methods, including a heat‐pulse flowmeter, passive flux meters, single‐well tracer tests, and high‐resolution hydraulic gradient analysis. Overall, the results confirmed that the PVP concept is valid and demonstrated that reliable estimates of groundwater velocity and direction can be obtained in simple settings. Also, PVPs can be successfully installed by conventional methods at sites where the formation consists primarily of noncohesive soils and the water table is relatively shallow. Although some PVP tests yielded consistent and reliable results, several tests did not. This is likely due to the highly transient flow conditions and limitations associated with the PVP design and testing procedures. PVPs offer particular advantages over, and can effectively complement, other groundwater flow characterization techniques for certain conditions, and objectives may be useful for characterizing complex flow patterns under steady conditions; however, this study suggests that PVPs are best suited for conditions where the flow hydraulics are not highly transient. For sites where the hydraulic conditions are highly transient, the most reliable approach for understanding groundwater flow behavior and groundwater–surface water interactions would generally involve both a high‐resolution hydraulic gradient analysis and another local‐scale method, such as tracer testing. This study also highlighted some aspects of the current PVP design and testing protocol that can be improved upon, including a more robust connection between the PVP and injection line and further assessment of tracer solution density effects on vertical flow. © 2013 Wiley Periodicals, Inc.  相似文献   

4.
The U.S. Department of Energy's (US DOE's) environmental challenges include remediation of the Hanford Site in Washington State. The site's legacy from nuclear weapons “production” activities includes approximately 80 square miles of contaminated groundwater, containing radioactive and other hazardous substances at levels above drinking water standards. In 1998, the U.S. General Accounting Office (US GAO), the auditing arm of Congress, concluded that groundwater remediation at Hanford should be integrated with a comprehensive understanding of the “vadose zone,” the soil region between the ground surface and groundwater. The US DOE's Richland Operations Office adjusted its program in response, and groundwater/vadose‐zone efforts at Hanford have continued to develop since that time. Hanford provides an example of how a federal remediation program can be influenced by reviews from the US GAO and other organizations, including the US DOE itself. © 2008 Wiley Periodicals, Inc.  相似文献   

5.
This perspective article was prepared by members of the Sustainable Remediation Forum (SURF), a professional nonprofit organization seeking to advance the state of sustainable remediation within the broader context of sustainable site reuse. SURF recognizes that remediation and site reuse, including redevelopment activities, are intrinsically linked—even when remediation is subordinate to or sometimes a precursor of reuse. Although the end of the remediation life cycle has traditionally served as the beginning of the site's next life cycle, a disconnect between these two processes remains. SURF recommends a holistic approach that brings together remediation and reuse on a collaborative parallel path and seeks to achieve whole‐system sustainability benefits. This article explores the value of integrating remediation into the reuse process to fully exploit synergies and minimize the costs and environmental impacts associated with bringing land back into beneficial use. © 2013 Wiley Periodicals, Inc.  相似文献   

6.
The U.S. Navy Public Works Center (PWC) Environmental Department, San Diego, California, is home to the Navy West Coast Site Characterization and Analysis Penetrometer System (SCAPS). SCAPS has been extensively used at several Navy sites since 1995 to provide real‐time, high‐density data sets. The U.S. Environmental Protection Agency's Triad approach provided an ideal framework for optimizing the use of the Navy SCAPS during a volatile organic compound (VOC) source investigation at Installation Restoration Site 1114 at Marine Corps Base Camp Pendleton. All three elements of Triad—systematic planning, dynamic work strategy, and use of real‐time measurement tools—were implemented to manage decision uncertainty and expedite the site management process. The investigation was conducted using the Navy SCAPS, outfitted with a cone penetrometer, membrane interface probe, and a direct sampling ion trap mass spectrometry detector, which allowed for real‐ time collection of over 690 feet of continuous lithologic information and VOC concentration data. These data were used collaboratively with 24‐hour turnaround US EPA 8260B VOC groundwater results from temporary direct‐ push wells to support the conclusion of a limited source area. Implementation of the Triad approach for this investigation provided an expedited high‐density data set and a refined conceptual site model (CSM) in real time that resulted in cost savings estimated at $2.5M and reduction of the site characterization and cleanup schedule by approximately three years. This project demonstrates how the US EPA's Triad approach can be applied to streamline the site characterization and cleanup process while appropriately managing decision uncertainty in support of defensible site decisions. © 2004 Wiley Periodicals, Inc.  相似文献   

7.
Bioremediation of 1,1,1‐trichloroethane (TCA) is more challenging than bioremediation of other chlorinated solvents, such as tetrachloroethene (PCE) and trichloroethene (TCE). TCA transformation often occurs under methanogenic and sulfate‐reducing conditions and is mediated by Dehalobacter. The source area at the project site contains moderately permeable medium sand with a low hydraulic gradient and is approximately 0.5 acre. TCA contamination generally extended to 35 feet, with the highest concentrations at approximately 20 feet. The concentrations then decreased with depth; several wells contained 300 to 600 mg/L of TCA prior to bioremediation. The area of treatment also contained 2 to 30 mg/L of TCE from an upgradient source. Initial site groundwater conditions indicated minimal biotic dechlorination and the presence of up to 20 mg/L of nitrate and 90 mg/L of sulfate. Microcosm testing indicated that TCA dechlorination was inhibited by the site's relatively low pH (5 to 5.5) and high TCA concentration. After the pH was adjusted and TCA concentrations were reduced to less than 35 mg/L (by dilution with site water), dechlorination proceeded rapidly using whey (or slower with sodium lactate) as an electron donor. Throughout the remediation program, increased resistance to TCA inhibition (from 35 to 200 mg/L) was observed as the microbes adapted to the elevated TCA concentrations. The article presents the results of a full‐scale enhanced anaerobic dechlorination recirculation system and the successful efforts to eliminate TCA‐ and pH‐related inhibition. © 2012 Wiley Periodicals, Inc.  相似文献   

8.
US Department of Energy (US DOE) responsibilities for its former national atomic weapons complex include remediation of the Rocky Flats facility near Denver, Colorado. In 1993, the site's primary mission shifted from “production'' of plutonium components for atomic weapons to cleanup of extensive radioactive and chemical contamination representing the legacy of production activities. Remediation was governed by the agreements between the US DOE as the responsible party and the US Environmental Protection Agency and the state of Colorado as joint regulators. In 1995, the Rocky Flats Future Use Working Group issued its final report, recommending among other features that long‐term cleanup reduce contamination levels to background. This article describes the circumstances that led the US DOE to complete the Rocky Flats cleanup more quickly and makes comparisons to the situation at the US DOE's Hanford site. © 2011 Wiley Periodicals, Inc.  相似文献   

9.
Negative public perceptions can dramatically increase site remediation costs or even bring projects to a grinding halt. Public opposition and ensuing political pressure are two damaging, but often ignored, obstacles that confront remediation managers. This article discusses these and other public management issues, recommending tactics proven for maintaining positive working relationships with a site's human neighbors, the media (electronic and print), government officials, regulatory agencies, and other concerned groups to allow site cleanup to proceed without intervention, opposition, or unnecessary delay. It illustrates its warnings about public and political hostility with case histories from Superfund, RCRA, and other cleanup sites, recounting how corporate management won the public's confidence and kept their projects on time and within budget.  相似文献   

10.
As a remediation tool, nanotechnology holds promise for cleaning up hazardous waste sites cost‐effectively and addressing challenging site conditions, such as the presence of dense nonaqueous phase liquids (DNAPLs). Some nanoparticles, such as nanoscale zero‐valent iron (nZVI) are already in use in full‐scale projects with encouraging success. Ongoing research at the bench and pilot scale is investigating particles such as self‐assembled monolayers on mesoporous supports (SAMMS™), dendrimers, carbon nanotubes, and metalloporphyrinogens to determine how to apply their unique chemical and physical properties for full‐scale remediation. There are many unanswered questions regarding nanotechnology. Further research is needed to understand the fate and transport of free nanoparticles in the environment, whether they are persistent, and whether they have toxicological effects on biological systems. In October 2008, the U.S. Environmental Protection Agency's Office of Superfund Remediation and Technology Innovation (OSRTI) prepared a fact sheet entitled “Nanotechnology for Site Remediation,” and an accompanying list of contaminated sites where nanotechnology has been tested. The fact sheet contains information that may assist site project managers in understanding the potential applications of this group of technologies. This article provides a synopsis of the US EPA fact sheet, available at http://clu‐in.org/542F08009 , and includes background information on nanotechnology; its use in site remediation; issues related to fate, transport, and toxicity; and a discussion of performance and cost data for field tests. The site list is available at http://clu‐in.org/products/nanozvi . © 2008 Wiley Periodicals, Inc.  相似文献   

11.
The New York State Department of Environmental Conservation (NYSDEC) Division of Environmental Remediation (DER) issued a program policy focused on the overall sustainability of hazardous waste site cleanups on August 11, 2010. This DER‐31/Green Remediation program policy (DER‐31) was issued in accordance with 6 New York Codes, Rules and Regulations (NYCRR) Part 375 Environmental Remediation Programs. DER‐31 represents one of the first government‐issued green and sustainable remediation (GSR) policies in the United States. Consistent with other DER policies, DER‐31's provisions are broadly considered to be an expectation/requirement. GSR experts from within AECOM's Remediation Services (RS) Practice Area developed and implemented a GSR program designed to comply with DER‐31 provisions and have now broadly incorporated GSR into our New York remediation projects. Lessons learned from this experience in New York have influenced AECOM's global GSR program and implementation procedures and prompted the development of a new GSR tool (GSRxTM) for identifying and assessing GSR best management practices (BMPs), which has also been employed globally. © 2013 Wiley Periodicals, Inc.  相似文献   

12.
1,4‐Dioxane is a synthetic industrial chemical frequently found at contaminated sites where 1,1,1‐trichloroethane was used for degreasing. It is a probable human carcinogen and has been found in groundwater at sites throughout the United States. The physical and chemical properties and behavior of 1,4‐dioxane create challenges for its characterization and treatment. It is highly mobile and has not been shown to readily biodegrade in the environment. In December 2006, the U.S. Environmental Protection Agency's Office of Superfund Remediation and Technology Innovation (OSRTI) prepared a report titled “Treatment Technologies for 1,4‐Dioxane: Fundamentals and Field Applications.” The report provides information about the chemistry of dioxane, cleanup goals, analytical methods, available treatment technologies, and site‐specific treatment performance data. The information may be useful to project managers, technology providers, consulting engineers, and members of academia faced with addressing dioxane at cleanup sites or in drinking water supplies. This article provides a synopsis of the US EPA report, which is available at http://cluin.org/542R06009 . © 2007 Wiley Periodicals, Inc.  相似文献   

13.
Enhanced anaerobic dechlorination is being conducted to remediate a 50‐acre groundwater area impacted with chlorinated volatile organic compounds (CVOCs). The plume, which is over 3,000 feet (ft) long, initially contained tetrachloroethene and breakdown products at concentrations of 2 to 3 milligrams per liter. The site's high groundwater flow velocity (greater than 1,000 ft per year) was incorporated into the design to help with amendment distribution. Bioaugmentation was conducted using a mixed culture containing Dehalococcoides ethenogenes. There is evidence that it has migrated to distances exceeding 600 ft. The major benefit of the high groundwater flow velocity is greater areal coverage by the remediation system, but the downside is the difficulty in delivering sufficient donor to create the required anaerobic conditions. Overall performance has been excellent with total CVOC reductions and conversion to ethene of 98 percent within a 25‐acre area downgradient of the treatment transect that has operated the longest. © 2011 Wiley Periodicals, Inc.  相似文献   

14.
Recent improvements in field‐portable analytical equipment allow accurate on‐site measurement of VOCs present in air at concentrations of less than 0.1 parts per million volume (ppmv). The objective of this project is to determine if the use of these instruments for vapor‐phase measurements of headspace in a monitoring well can serve as a reliable and accurate method for monitoring volatile organic compound (VOC) concentrations in groundwater under equilibrium conditions. As part of a comprehensive research project investigating the utility of this proposed monitoring method, the authors have completed a laboratory validation study to identify instruments and sample‐collection methods that will provide accurate measurement of VOC concentrations in groundwater. This laboratory validation study identified two field‐portable instruments (a gas chromatograph and a photoionization detector) with sufficient sensitivity to measure VOCs in groundwater at concentrations below typical monitoring standards (i.e., 1 to 5 μg/L). The accuracy and precision of these field instruments was sufficient to satisfy typical data‐quality objectives for laboratory‐based analysis. In addition, two sample‐collection methods were identified that yield vapor‐phase samples in equilibrium with water: direct headspace sampling and passive diffusion samplers. These sample‐collection methods allow the field instruments (which measure VOC concentrations in vapor‐phase samples) to be used to measure VOC concentrations in water. After further validation of these sample‐collection methods in the field, this monitoring method will provide a simple way to obtain accurate real‐time measurements of VOC concentrations in groundwater using inexpensive field‐portable analytical instruments. © 2009 Wiley Periodicals, Inc.  相似文献   

15.
The U.S. Department of Energy's (US DOE's) responsibilities for its former national nuclear weapons complex include remediation of the Hanford Site in Washington State. In 1989, the site's primary mission shifted from nuclear weapons material production to cleanup of the extensive radioactive and chemical contamination that represented the production legacy. Cleanup is governed by the Tri‐Party Agreement (TPA), between the US DOE, as responsible party, and the U.S. Environmental Protection Agency and Washington State Department of Ecology, as joint regulators. Nearly 20 years have passed since the TPA was signed, but the Hanford remediation is expected to require decades longer. This article covers the cleanup progress to date and challenges that remain, particularly from millions of gallons of highly radioactive liquid wastes and proposals to bring new wastes to Hanford. © 2008 Wiley Periodicals, Inc.  相似文献   

16.
Permeable reactive barriers (PRBs) have traditionally been constructed via trenching backfilled with granular, long‐lasting materials. Over the last decade, direct push injection PRBs with fine‐grained injectable reagents have gained popularity as a more cost‐efficient and less‐invasive approach compared to trenching. A direct push injection PRB was installed in 2005 to intercept a 2,500 feet (760 meter) long carbon tetrachloride (CT) groundwater plume at a site in Kansas. The PRB was constructed by injecting EHC® in situ chemical reduction reagent slurry into a line of direct push injection points. EHC is composed of slow‐release plant‐derived organic carbon plus microscale zero‐valent iron (ZVI) particles, specifically formulated for injection applications. This project was the first full‐scale application of EHC into a flow‐through reactive zone and provided valuable information about substrate longevity and PRB performance over time. Groundwater velocity at the site is high (1.8 feet per day) and sulfate‐rich (~120 milligrams per liter), potentially affecting the rate of substrate consumption and the PRB reactive life. CT removal rates peaked 16 months after PRB installation with >99% removal observed. Two years post‐installation removal rates decreased to approximately 95% and have since stabilized at that level for the 12 years of monitoring data available after injection. Geochemical data indicate that the organic carbon component of EHC was mostly consumed after 2 years; however, reducing conditions and a high degree of chloromethane treatment were maintained for several years after total organic carbon concentrations returned to background. Redox conditions are slowly reverting and have returned close to background conditions after 12 years, indicating that the PRB may be nearing the end of its reactive life. Direct measurements of iron have not been performed, but stoichiometric demand calculations suggest that the ZVI component of EHC may, in theory, last for up to 33 years. However, the ZVI component by itself would not be expected to support the level of treatment observed after the organic carbon substrate had been depleted. A longevity of up to 5 years was originally estimated for the EHC PRB based on the maximum expected longevity of the organic carbon substrate. While the organic carbon was consumed faster than expected, the PRB has continued to support a high degree of chloromethane treatment for a significantly longer time period of over 12 years. Recycling of biomass and the contribution from a reduced iron sulfide mineral zone are discussed as possible explanations for the sustained reducing conditions and continued chloromethane treatment.  相似文献   

17.
In June and July 2001, the Massachusetts Department of Environmental Protection (MassDEP) installed a permeable reactive barrier (PRB) to treat a groundwater plume of chlorinated solvents migrating from an electronics manufacturer in Needham, Massachusetts, toward the Town of Wellesley's Rosemary Valley wellfield. The primary contaminant of concern at the site is trichloroethene (TCE), which at the time had a maximum average concentration of approximately 300 micrograms per liter directly upgradient of the PRB. The PRB is composed of a mix of granular zero‐valent iron (ZVI) filings and sand with a pure‐iron thickness design along its length between 0.5 and 1.7 feet. The PRB was designed to intercept the entire overburden plume; a previous study had indicated that the contaminant flux in the bedrock was negligible. Groundwater samples have been collected from monitoring wells upgradient and downgradient of the PRB on a quarterly basis since installation of the PRB. Inorganic parameters, such as oxidation/reduction potential, dissolved oxygen, and pH, are also measured to determine stabilization during the sampling process. Review of the analytical data indicates that the PRB is significantly reducing TCE concentrations along its length. However, in two discrete locations, TCE concentrations show little decrease in the downgradient monitoring wells, particularly in the deep overburden. Data available for review include the organic and inorganic analytical data, slug test results from nearby bedrock and overburden wells, and upgradient and downgradient groundwater‐level information. These data aid in refining the conceptual site model for the PRB, evaluating its performance, and provide clues as to the reasons for the PRB's underperformance in certain locations. © 2008 Wiley Periodicals, Inc.  相似文献   

18.
The evaluation of microbial responses to three in situ source removal remedial technologies—permanganate‐based in situ chemical oxidation (ISCO), six‐phase heating (SPH), and steam injection (SI)—was performed at Cape Canaveral Air Station in Florida. The investigation stemmed from concerns that treatment processes could have a variety of effects on the indigenous biological activity, including reduced biodegradation rates and a long‐term disruption of community structure with respect to the stimulation of TCE (trichloroethylene) degraders. The investigation focused on the quantity of phospholipid fatty acids (PLFAs) and its distribution to determine the immediate effect of each remedial technology on microbial abundance and community structure, and to establish how rapidly the microbial communities recovered. Comprehensive spatial and temporal PLFA screening data suggested that the technology applications did not significantly alter the site's microbial community structure. The ISCO was the only technology found to stimulate microbial abundance; however, the biomass returned to predemonstration values shortly after treatment ended. In general, no significant change in the microbial community composition was observed in the SPH or SI treatment areas, and even small changes returned to near initial conditions after the demonstrations. © 2004 Wiley Periodicals, Inc.  相似文献   

19.
In January 2005, a gasoline tanker carrying approximately 8,500 gallons of gasohol (gasoline containing 10 percent ethanol) overturned and caught fire in the front yard of a residence. Emergency response crews responded to the accident, extinguished the fire, and recovered residual gasoline on the ground surface. Soil impacted by the release was then removed and disposed of off‐site and free‐phase gasohol was recovered using a combination of vacuum recovery, pumping, and bailing to the extent practicable. Following free product recovery efforts, a feasibility evaluation was completed to select a technology to address the remaining dissolved‐phase contaminants that resulted in biosparging pilot testing and, ultimately, the installation of a full‐scale biosparging system. The full‐scale system has been operating for approximately 21 months, and contaminant concentrations within the heart of the plume have decreased dramatically over a short period of time—in most cases, to below applicable cleanup standards. Despite the complex hydrogeologic conditions and significant initial concentrations, biosparging has proven to be an effective technology to remediate this gasohol release, and it is anticipated that drinking‐water standards can be achieved following two to three years of biosparging (i.e., an additional 3 to 15 months of operations). © 2010 Wiley Periodicals, Inc.  相似文献   

20.
Chlorinated solvents were released to the surficial groundwater underneath a former dry cleaning building, resulting in a groundwater plume consisting of high concentrations of trichloroethene (TCE) and cis‐1,2‐dichloroethene (cis‐1,2‐DCE) and low concentrations of tetrachloroethene (PCE) and vinyl chloride. The initial remedial action included chemical oxidation via injection of 14,400 gallons of Fenton's Reagent in March 2002, and an additional 14,760 gallons in April 2002. A sharp reduction of contaminant concentrations in groundwater was observed the following month; however, rebound of contaminant concentrations was evident as early as October 2002. A source area of PCE‐impacted soils was excavated in June 2004. Following the excavation, Golder Associates Inc. (2007) implemented a biostimulation plan by injecting 55 gallons of potassium lactate (PURASAL® HiPure P) in September 2005, and again in February 2006. Comparing the preinjection and postinjection site conditions, the potassium lactate treatments were successful in accomplishing a 40 to 70 percent reduction in mass within four months following the second injection. Elevated vinyl chloride concentrations have persisted through both injection events; however, significant vinyl chloride reduction has been observed in one well with the highest total organic carbon (TOC) concentrations following each injection. © 2008 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号