首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Tetrachloroethylene, also known as perchloroethylene or PCE, is one of the most difficult to treat chlorinated solvents when present in groundwater. Unfortunately, this elusive and recalcitrant compound is also the most commonly used dry cleaning solvent. As a result, releases of PCE at dry cleaning sites are somewhat common. Regenesis Bioremediation Products, of San Clemente, California, has developed Hydrogen Release Compound (HRC), which has been successfully used to promote bioremediation of PCE in groundwater. This product is directly injected into contaminated groundwater to speed up the natural attenuation of PCE through an anaerobic, natural process known as reductive dechlorination. A key benefit of HRC is its ability to slowly release hydrogen over extended periods of time. Reductive dechlorination relies on a steady source and readily available supply of electron donors as part of the degradation process. Hydrogen is one of the best electron donors available, and thus, the application of HRC significantly enhances the rate of PCE degradation. For dry cleaners, this technology can substantially reduce major design, capital, and operating costs, allowing the implementation of a low‐impact application and remediation solution. This article discusses the use of the HRC to remediate PCE contamination and presents the results of two specific HRC‐treated dry cleaner sites. © 2002 Wiley Periodicals, Inc.  相似文献   

2.
Groundwater investigations conducted since 1988 at a Tennessee Department of Environment and Conservation (TDEC) Voluntary Oversight and Assistance Program (VOAP) site located in Millington, Tennessee, have defined the lateral and vertical extent of site chemicals of concern (COCs) consisting of tetrachloroethene (PCE), trichloroethene (TCE), and associated degradation products. Results of a groundwater remedial investigation determined that aquifer conditions were favorable for anaerobic degradation of COCs through reductive dechlorination. A subsequent groundwater feasibility study determined that monitored natural attenuation (MNA) coupled with long‐term groundwater monitoring was the most effective and suitable remedial option for the site. A Record of Decision was issued by the TDEC VOAP approving MNA and long‐term groundwater monitoring as the remedial option for the site, a first for such a site in Tennessee involving chlorinated organics. A groundwater fate and transport model (the 1998 model) developed during the RI was used as the basis for the MNA remedy. Analytical data from 1998 to 2008 indicate COCs in former high‐concentration areas continue to degrade at rates consistent with or ahead of the 1998 model predictions. Evidence of reductive dechlorination is also supported by the continued presence of breakdown products—specifically, vinyl chloride and ethene (terminal endpoint of PCE breakdown through reductive dechlorination). The continued detection of breakdown products along the flow‐path wells also confirms the effectiveness of the MNA remedy at the site. Current analytical data indicate that COC plumes beneath the site are not migrating and are actually retracting. © 2010 Wiley Periodicals, Inc.  相似文献   

3.
Contaminants from dry‐cleaning sites, primarily tetrachloroethene (PCE), trichloroethene (TCE), cis‐dichloroethene (cis‐DCE), and vinyl chloride (VC), have become a major concern because of the limited funds and regulatory programs to address them. Thus, natural attenuation and its effectiveness for these sites needs to be evaluated as it might provide a less costly alternative to other remediation methods. In this research, data from a site in Texas were analyzed and modeled using the Biochlor analytical model to evaluate remediation times using natural attenuation. It was determined that while biodegradation and source decay were occurring at the site, the resulting attenuation rates were not adequate to achieve cleanup in a reasonable time frame without additional source remediation or control strategies. Cleanup times exceeded 100 years for all constituents at the site boundary and 800 years at the source for PCE, assuming cleanup levels of 0.005 mg/L for PCE and TCE and 0.07 mg/L and 0.002 mg/L for cis‐DCE and VC, respectively. © 2005 Wiley Periodicals, Inc.  相似文献   

4.
This article defines and presents a systematic approach to groundwater plume‐stability assessment. Qualitative and quantitative methods that have been used to assess plume stability at National Priority List sites undergoing optimization are reviewed. Example case studies are included to illustrate the advantages of combining multiple analysis methods. Relevant statistical methods include identifying normal data distributions, detection frequencies, coefficients of variation, individual well trends, and rates of change at individual monitoring locations. Trend estimates for total plume mass and center of mass provide a broader picture of plumewide processes. Deterministic methods, such as quantitative mass‐balance approaches, may be useful for larger plumes. Qualitative assessments include evaluations of the conceptual site model, source strength, attenuation mechanisms, and hydrogeology. Because groundwater plumes are always dynamic, the determination of plume stability has to include qualitative steps relating the rate and magnitude of change to the goals and objectives of the program and the time frame over which critical management decisions are to be made. The assessment of plume stability is, therefore, presented as a process that should involve both qualitative and quantitative steps for determining the acceptability of variability in groundwater contaminant concentrations. © 2010 Wiley Periodicals, Inc.  相似文献   

5.
Contaminated groundwater and surface water have posed a great challenge in restoring wood preserving sites to beneficial use. Often contaminated groundwater plumes extend far beyond the legal property limits, adversely impacting drinking water supplies and crop lands. To contain, treat, and/or remediate these valuable resources is an important part of restoring these impacted sites. Various options are available for remediating the groundwater and other affected media at these sites. Frequently, pump and treat technologies have been used that can provide well‐head treatment at installed extraction wells. This approach has shown to be costly and excessively time consuming. Some of the technologies used for pump and treat are granular activated carbon (GAC), biotreatment, and chemical oxidation. Other approaches use in‐situ treatment applications that include enhanced bioremediation, monitored natural attenuation (biotic and abiotic), and chemical reduction/fixation. Ultimately, it may only be feasible, economically or practicably, to use hydraulic containment systems. Depending upon site‐specific conditions, these treatment approaches can be used in various combinations to offer the best remedial action. A comparison of water treatment system costs extrapolated from the treatability studies performed on contaminated groundwater from the McCormick/Baxter Superfund site in Stockton, California, yielded operation and maintenance costs of $1.19/1,000 gal. for carbon treatment and $7.53/1,000 gal. for ultraviolet (UV) peroxidation, respectively.  相似文献   

6.
The data mining/groundwater modeling methodology developed in McDade et al. (2013) was performed to determine if matrix diffusion is a plausible explanation for the lower‐concentration but persistent chlorinated solvent plumes in the groundwater‐bearing units at three different pump‐and‐treat systems. Capture‐zone maps were evaluated, and eight wells were identified that did not draw water from any of the historical source areas but captured water from the sides of the plume. Two groundwater models were applied to study the persistence of the plumes in the absence of contributions from the historical source zones. In the wells modeled, the observed mass discharge generally decreased by about one order of magnitude or less over 4 to 10 years of pumping, and 1.8 to 17 pore volumes were extracted. In five of the eight wells, the matrix diffusion model fit the data much better than the advection dispersion retardation model, indicating that matrix diffusion better explains the persistent plume. In the three other wells, confounding factors, such as a changing capture zone over time (caused by changes in pumping rates in adjacent extraction wells); potential interference from a high‐concentration unremediated source zone; and limited number of pore volumes removed made it difficult to confirm that matrix diffusion processes were active in these areas. Overall, the results from the five wells indicate that mass discharge rates from the pumping wells will continue to show a characteristic “long tail'' of mass removal from zones affected by active matrix diffusion processes. Future site management activities should include matrix diffusion processes in the conceptual site models for these three sites. © 2013 Wiley Periodicals, Inc.  相似文献   

7.
When used in combination with source management strategies, monitored natural attenuation (MNA) is likely to be a technically feasible remediation option if the contaminant persistence time along the flow path is less than (a) the transport time to the compliance point and (b) the time available for groundwater remediation objectives to be achieved. Biodegradation is often the most significant natural attenuation process for benzene, toluene, ethylbenzene, and xylenes (BTEX) in groundwater. While BTEX transport rates increase with groundwater velocity, examination of data obtained from the published literature for seven sites undergoing MNA revealed significant positive correlations between groundwater velocity and first‐order biodegradation rates for toluene (r = 0.83, P < 0.05), ethylbenzene (r = 0.93, P < 0.01), m‐ and p‐xylene (r = 0.96, P < 0.01), and o‐xylene (r = 0.78, P < 0.05). This is attributed to increased dispersion at higher velocities leading to more mixing of electron acceptors with the contaminant plume. There was no positive correlation between groundwater velocity and first‐order biodegradation rates for benzene due to noise in the relationship caused by variations in (a) the concentrations of electron acceptors in the uncontaminated groundwater and (b) the proportions of benzene in the total BTEX concentration in the source area. A regression model of the relationship between groundwater velocity and the first‐order biodegradation rate can be used to delineate operating windows for groundwater velocity within which the contaminant persistence time is less than the transport and remediation times for a given source concentration, target concentration, distance to compliance point, retardation factor, and remediation time. The operating windows can provide decision makers with a rapid indication of whether MNA is likely to be a technically feasible remediation option at a given site. © 2005 Wiley Periodicals, Inc.  相似文献   

8.
Natural biodegradation can contain groundwaters impacted by creosote and pentachlorophenol. Using natural biodegradation for such sites is attractive because groundwater restoration is often impracticable, but the dissolved plumes are biodegradable and exert relatively low oxygen demands. Three case studies of its successful use are presented, with emphasis on the types of evidence needed, the rates and extents of removal, and the strategies for incorporating natural biodegradation into a remediation approach. Natural biodegradation was proven at all three sites, using a combination of field geochemical measurements, laboratory simulations, and computer modeling. Contaminant plumes at these three sites were contained within 100 to 700 feet downgradient of the apparent sources, although the rates of biodegradation varied widely. Natural biodegradation should be considered as part of an overall remedial strategy for most sites contaminated by creosote and/or pentachlorophenol.  相似文献   

9.
This article presents field tests comparing two methods of treatment of chlorinated solvents undertaken at the same site. The site is an automobile factory where two chlorinated solvents (CS) plumes were identified. At the first source, in situ chemical reduction (ISCR) was applied, while at the second one, enhanced natural attenuation (ENA) was used. A set of specific multilevel sampling wells were installed approximately 20 m downgradient of the sources to estimate the efficiency of the treatments. The presence of a low‐permeability layer (source 1) or a thick oil lens (source 2) in the top part of the aquifer prevented the CS from reaching the bottom of the aquifer. These layers led to difficulties treating the contamination. At the ISCR and ENA treatment zones, the concentrations of tetrachloroethene (PCE) and trichloroethene (TCE) did not change significantly, while the concentration of metabolites (cis‐1,2‐DCE, vinyl chloride, and ethene) significantly increased 50 to 150 days after treatment. Due to high concentration of CS in the source zone, a mass balance calculation, including chlorine, was possible. It showed that around 1 to 2 percent of the injected products were used to reduce the CS. A detailed analysis and 1D analytical modeling of CS concentrations showed that the treatment led to a large (two to three times) increase in dissolution of the organic phase. This explains why, despite an efficient treatment, the PCE and TCE concentrations remained virtually unchanged. Degradation rates also increased due to the treatment. Due to some differences in the source‐zone chemistry, it was not possible to differentiate between the ISCR and ENA efficiencies. © 2013 Wiley Periodicals, Inc.  相似文献   

10.
Nanoscale zero valent iron (nZVI) was evaluated in a laboratory treatability study and subsequently injected as an interim measure to treat source area groundwater impacts beneath a former dry cleaner located in Chapel Hill, North Carolina (the site). Dry cleaning operations resulted in releases of tetrachloroethene (PCE) that impacted site soil at concentrations up to 2,700 mg/kg and shallow groundwater at concentrations up to 41 mg/L. To achieve a design loading rate of 0.001 kg of iron per kilogram of aquifer material, approximately 725 kg of NanoFe? (PARS Environmental) was injected over a two‐week period into a saprolite and partially weather rock aquifer. Strong reducing conditions were established with oxidation–reduction potential (ORP) values below –728 mV. pH levels remained greater than 8 standard units for a period of 12 months. Injections resulted in near elimination of PCE within one month. cis‐1,2‐Dichloroethene accumulated at high concentrations (greater than 65 mg/L) for 12 months. MAROS software (Version 2.2; AFCEE, 2006 ) was used to calculate mass reduction of PCE and total ethenes at 96 percent and 58 percent, respectively, compared to baseline conditions. Detections of acetylene confirmed the presence of the beta‐elimination pathway. Detections of ethene confirmed complete dechlorination of PCE. Based on hydrogen gas generation, iron reactivity lasted 15 months. © 2013 Wiley Periodicals, Inc.  相似文献   

11.
Established groundwater contaminants such as chlorinated solvents and hydrocarbons have impacted groundwater at hundreds of thousands of sites around the United States and have been responsible for multibillion dollar remediation expenditures. An important question is whether groundwater remediation for the emerging contaminant class comprised of per‐ and polyfluoroalkyl substances (PFAS) will be a smaller, similar, or a larger‐scale problem than the established groundwater contaminants. A two‐pronged approach was used to evaluate this question in this paper. First, nine quantitative scale‐of‐remediation metrics were used to compare PFAS to four established contaminants: chlorinated solvents, benzene, 1,4‐dioxane, and methyl tert‐butyl ether. These metrics reflected the prevalence of the contaminants in the U.S., attenuation potential, remediation difficulty, and research intensity. Second, several key challenges identified with PFAS remediation were evaluated to see similar situations (qualitative analogs) that have been addressed by the remediation field in the past. The results of the analysis show that four out of nine of the evaluated quantitative metrics (production, number of potential sites, detection frequency, required destruction/removal efficiency) indicate that the scale of PFAS groundwater remediation may be smaller compared to the current scale of remediation for conventional groundwater contaminants. One attenuation metric, median plume length, suggests that overall PFAS remediation could pose a greater challenge compared to hydrocarbon sites, but only slightly larger than chlorinated volatile organic compounds sites. The second attenuation metric, hydrophobic sorption, was not definitive regarding the potential scale of PFAS remediation. The final three metrics (regulatory criteria, in‐situ remediation capability, and research intensity) all indicate that PFAS remediation might end up being a larger scale problem than the established contaminants. An assessment of the evolution of groundwater remediation capabilities for established contaminants identified five qualitative analogs for key PFAS groundwater remediation issues: (a) low‐level detection analytical capabilities; (b) methods to assess the risk of complex chemical mixtures; (c) nonaqueous phase dissolution as an analog for partitioning, precursors, and back diffusion at PFAS sites; (d) predictions of long plume lengths for emerging contaminants; and (e) monitored natural attenuation protocols for other non‐degrading groundwater contaminants. Overall the evaluation of these five analogs provided some comfort that, while remediating the potential universe of PFAS sites will be extremely challenging, the groundwater community has relevant past experience that may prove useful. The quantitative metrics and the qualitative analogs suggest a different combination of remediation approaches may be needed to deal with PFAS sites and may include source control, natural attenuation, in‐situ sequestration, containment, and point‐of‐use treatment. However, as with many chlorinated solvent sites, while complete restoration of PFAS sites may be uncommon, it should be possible to prevent excessive exposure of PFAS to human and ecological receptors.  相似文献   

12.
This article presents site closure strategies of source material removal and dissolved‐phase groundwater natural attenuation that were applied at two manufactured gas plant (MGP) sites in Wisconsin. The source removal actions were implemented in 1999 and 2000 with groundwater monitoring activities preceding and following those actions. Both of these sites have unique geological and hydrogeological conditions. The article briefly presents site background information and source removal activities at both of these sites and focuses on groundwater analytical testing data that demonstrate remediation of dissolved‐phase MGP‐related groundwater impacts by natural attenuation. A statistical evaluation of the data supports a stable or declining MGP parameter concentration trend at each of the sites. A comparison of the site natural attenuation evaluation is made to compare with the requirements for site closure under the Wisconsin Department of Natural Resources regulations and guidance. © 2003 Wiley Periodicals, Inc.  相似文献   

13.
Tetrachloroethene (PCE) releases at a former dry cleaner resulted in impacts to soil and shallow groundwater beneath and adjacent to the building. Subsurface impacts led to vapor intrusion with PCE concentrations between 900 and 1,200 micrograms per cubic meter (μg/m3) in indoor air. The migration pathways of impacted soil vapor were evaluated through implementation of a helium tracer test and vapor sampling of an exterior concrete block wall. Results confirmed that the concrete block wall acted as a conduit for vapor intrusion into the building. A combination of remediation efforts focused on mass reduction in the source area as well as mitigation efforts to inhibit vapor migration into the building. Excavation of soils beneath the floor slab and installation of a spray‐applied vapor barrier resulted in PCE concentrations in indoor air decreasing by over 97.9 percent. Operation of an active ventilation system installed under the floor slab and groundwater remediation via injections of nano‐scale zero valent iron (nZVI) further reduced PCE concentrations in indoor air by over 99.8 percent compared to baseline conditions. While significant reductions of PCE concentrations in groundwater were observed within two months after injection, maximum reductions to PCE concentrations in indoor air were not observed for an additional 12 months. © 2014 Wiley Periodicals, Inc.  相似文献   

14.
This study evaluated the effect of heterogeneity in hydraulic conductivity on the tendency for contaminant plumes to attenuate via dilution, hydrodynamic dispersion, and molecular diffusion in simulated aquifers. Simulations included one homogeneous and four increasingly heterogeneous hydraulic conductivity fields. A numerical mass transport model generated an initial contaminant plume for each case; all initial plumes had the same mass. Next, the model simulated plume migrations through the simulated aquifers. Results suggest that highly heterogeneous settings are potentially effective at plume attenuation. Low‐velocity zones in heterogeneous settings delay plume travel, enabling more time for natural processes to lower contaminant concentrations in groundwater. © 2012 Wiley Periodicals, Inc.  相似文献   

15.
In situ chemical oxidation (ISCO) with permanganate has been widely used for soil and groundwater treatment in the saturated zone. Due to the challenges associated with achieving effective distribution and retention in the unsaturated zone, there is a great interest in developing alternative injection technologies that increase the success of vadose‐zone treatment. The subject site is an active dry cleaner located in Topeka, Kansas. A relatively small area of residual contamination adjacent to the active facility building has been identified as the source of a large sitewide groundwater contamination plume with off‐site receptors. The Kansas Department of Health and Environment (KDHE) currently manages site remedial efforts and chose to pilot‐test ISCO with permanganate for the reduction of perchloroethene (PCE) soil concentrations within the source area. KDHE subsequently contracted Burns & McDonnell to design and implement an ISCO pilot test. A treatability study was performed by Carus Corporation to determine permanganate‐soil‐oxidant‐demand (PSOD) and the required oxidant dosing for the site. The pilot‐test design included an ISCO injection approach that consisted of injecting aqueous sodium permanganate using direct‐push technology with a sealed borehole. During the pilot test, approximately 12,500 pounds of sodium permanganate were injected at a concentration of approximately 3 percent (by weight) using the methods described above. Confirmation soil sampling conducted after the injection event indicated PCE reductions ranging from approximately 79 to more than 99 percent. A follow‐up treatment, consisting of the injection of an additional 6,200 pounds of sodium permanganate, was implemented to address residual soil impacts remaining in the soil source zone. Confirmation soil sampling conducted after the treatment indicated a PCE reduction of greater than 90 percent at the most heavily impacted sample location and additional reductions in four of the six samples collected. © 2009 Wiley Periodicals, Inc.  相似文献   

16.
A survey of experts in the application of natural attenuation was conducted to better understand how monitored natural attenuation (MNA) is being applied at chlorinated solvent sites. Thirty‐four remediation professionals provided general information for 191 sites where MNA was evaluated, and site‐specific data for 45 chlorinated solvent plumes being remediated by MNA. Respondents indicated that MNA was precluded as a remedy at only 23 percent of all sites where evaluated as a remedial option. Leading factors excluding MNA as a remedial approach were the presence of an expanding plume and an unreasonably long estimated remediation time frame. MNA is being used as the sole remedy at about 30 percent of the sites, and 33 percent are implementing MNA in conjunction with source zone remediation. The remaining sites are implementing MNA with plume remediation (13 percent), source containment (9 percent), or some other strategy (16 percent). © 2004 Wiley Periodicals, Inc.  相似文献   

17.
Two adjacent automotive component manufacturers in Japan had concentrations of trichloroethene (TCE) and perchloroethene (PCE) in soils and groundwater beneath their plants. One of the manufacturers extensively used these solvents in its processes, while the adjacent manufacturer had no documentation of solvent use. The conceptual site model (CSM) initially involved a single source that migrated from one building to under the adjacent building. Further, because low concentrations of daughter products (e.g., cis‐1,2‐dichloroethene; 3.6 to 840 micrograms per liter [μg/L]) were detected in groundwater, the CSM did not consider intrinsic degradation to be a significant fate mechanism. With this interpretation, the initial remedial design involved both source treatment and perimeter groundwater control to prevent offsite migration of the solvents in groundwater. Identifying whether intrinsic degradation was occurring and could be quantified represented a means of eliminating this costly and potentially redundant component. Further, incorporating intrinsic degradation into the remediation design would also allow for a more focused source treatment, resulting in further cost savings. Three rounds of sampling and data interpretation applying compound specific isotope analysis (CSIA) were used to refine the CSM. The first sampling round involved three‐dimensional CSIA (13C, 37Cl, and 2H), while the second two rounds involved 13C only, focusing on degradation over time. For the May 2012 sampling, δ13C for PCE ranged from –31‰ to –29.6 ‰ and for TCE ranged from –30.4‰ to –28.3‰; showing similar values. δ2H for TCE ranged from 581‰ to 629‰, indicating a manufactured TCE rather than that resulting from dehalogenation processes from PCE. However, mixing of manufactured TCE with that resulting from degraded PCE cannot be ruled out. Because of the similar δ13C ratios for PCE and TCE, and 37Cl data for PCE and TCE, fractionation and enrichment factors could not be relied upon. Fractionation patterns were evaluated using graphical methods to trace TCE to the source location to better focus the locations for steam injection. Graphical methods were also used to define the degradation mechanism and from this, incorporate intrinsic degradation processes into the remedial design, eliminating the need for a costly perimeter pump and treat system. ©2015 Wiley Periodicals, Inc.  相似文献   

18.
The Naval Facilities Engineering Service Center (NFESC), Arizona State University, and Equilon Enterprises LLC are partners in an innovative Environmental Security Technology Certification Program cleanup technology demonstration designed to contain dissolved MTBE groundwater plumes. This full‐scale demonstration is being performed to test the use of an oxygenated biobarrier at Naval Base Ventura County, in Port Hueneme, California. Surprisingly, few cost‐effective in‐situ remedies are known for the cleanup of MTBE‐impacted aquifers, and remediation by engineered in‐situ biodegradation was thought to be an unlikely candidate just a few years ago. This project demonstrates that MTBE‐impacted groundwater can be remediated in‐situ through engineered aerobic biodegradation under natural‐flow conditions. With respect to economics, the installation and operation costs associated with this innovative biobarrier system are at least 50 percent lower than those of a conventional pump and treat system. Furthermore, although it has been suggested that aerobic MTBE biodegradation will not occur in mixed MTBE‐BTEX dissolved plumes, this project demonstrates otherwise. The biobarrier system discussed in this article is the largest of its kind ever implemented, spanning a dissolved MTBE plume that is over 500 feet wide. This biobarrier system has achieved an in‐situ treatment efficiency of greater than 99.9 percent for dissolved MTBE and BTEX concentrations. Perhaps of greater importance is the fact that extensive performance data has been collected, which is being used to generate best‐practice design and cost information for this biobarrier technology. © 2001 John Wiley & Sons, Inc.  相似文献   

19.
Chlorinated solvents such as tetrachloroethene (perchloroethene, PCE) and trichloroethene (TCE) have been extensively used in various industrial applications for many years. Because neither are typically consumed through their various uses, they are often released to the environment through industrial application or disposal. Once released, PCE and TCE tend to migrate downward into groundwater, where they persist. In the current case study, cheese whey was used as a groundwater amendment to facilitate the reductive dechlorination of a chlorinated solvent plume underlying an auto dealer/repair shop in Harris County, Texas. From September 2010 to January 2014, over 32,000 gallons of cheese whey were injected into the subsurface resulting in a marked reduction in oxidation–reduction potential (ORP) and nitrate concentrations, coupled with an increase in ferrous iron concentrations. Statistical trend analyses indicate the primary contaminants, PCE and TCE, as well as the daughter product cis‐1,2‐dichloroethene (cDCE), all exhibited a positive response, as evidenced by statistically decreasing trends, and/or reversal in concentration trends, subsequent to cheese whey injections. Maximum concentrations of PCE and TCE in key test wells decreased by as much as 98.97 percent and 99.17 percent, respectively. In addition, the bacterial genus Dehalococcoides, capable of complete reduction of PCE to non‐toxic ethene, was found to be more abundant in the treatment area, as compared to background concentrations. Because cheese whey is a by‐product of the cheese making process, the cost of the product is essentially limited to transport. This study demonstrates cheese whey to be an effective groundwater amendment at a cost which is orders of magnitude lower than popular industry alternatives.  相似文献   

20.
Isotope applications are gaining acceptance for use in surface water and groundwater investigations, complementing traditional geochemistry and physical hydrology techniques. Recent developments in analytical methodologies and in the understanding of isotope dynamics now allow the use of isotopes to investigate sources and fate of common groundwater contaminants such as chlorinated solvents and petroleum hydrocarbons. Contaminants with unique isotopic signatures may facilitate the determination of contaminant sources in complex plumes. Degradation of chlorinated solvents and some petroleum hydrocarbons impart unique isotopic signatures on both the original contaminant and the degradation product or products that provide verification of degradation. Use of a Rayleigh‐type model may allow determination of degradation extent. Coupled with models of contaminant fate and transport, degradation extent may be useful for determining degradation rates. © 2001 John Wiley & Sons, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号